Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Rapid imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The Portable Dynamic Fundus Instrument: Uses in telemedicine and research

For years ophthalmic photographs have been used to track the progression of many ocular diseases such as macular degeneration and glaucoma as well as the ocular manifestations of diabetes, hypertension, and hypoxia. In 1987 a project was initiated at the Johnson Space Center (JSC) to develop a means of monitoring retinal vascular caliber and intracranial pressure during space flight. To conduct telemedicine during space flight operations, retinal images would require real-time transmissions from space. Film-based images would not be useful during in-flight operations. Video technology is beneficial in flight because the images may be acquired, recorded, and transmitted to the ground for rapid computer digital image processing and analysis. The computer analysis techniques developed for this project detected vessel caliber changes as small as 3 percent. In the field of telemedicine, the Portable Dynamic Fundus Instrument demonstrates the concept and utility of a small, self-contained video funduscope. It was used to record retinal images during the Gulf War and to transmit retinal images from the Space Shuttle Columbia during STS-50. There are plans to utilize this device to provide a mobile ophthalmic screening service in rural Texas. In the fall of 1993 a medical team in Boulder, Colorado, will transmit real-time images of the retina during remote consultation and diagnosis. The research applications of this device include the capability of operating in remote locations or small, confined test areas. There has been interest shown utilizing retinal imaging during high-G centrifuge tests, high-altitude chamber tests, and aircraft flight tests. A new design plan has been developed to incorporate the video instrumentation into face-mounted goggle. This design would eliminate head restraint devices, thus allowing full maneuverability to the subjects. Further development of software programs will broaden the application of the Portable Dynamic Fundus Instrument in telemedicine and medical research.

Hunter, Norwood↗

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

47 OTHER INSTRUMENTATION↗

Revealing room temperature ferromagnetism in exfoliated Fe 5 GeTe 2 flakes with quantum magnetic imaging

Van der Waals (vdW) material Fe 5 GeTe 2 , with its long-range ferromagnetic ordering near room temperature, has significant potential to become an enabling platform for implementing novel spintronic and quantum devices. To pave the way for applications, it is crucial to determine the magnetic properties when the thickness of Fe 5 GeTe 2 reaches the few-layers regime. However, this is highly challenging due to the need for a characterization technique that is local, highly sensitive, artifact-free, and operational with minimal fabrication. Prior studies have indicated that Curie temperature T C can reach up to close to room temperature for exfoliated Fe 5 GeTe 2 flakes, as measured via electrical transport; there is a need to validate these results with a measurement that reveals magnetism more directly. Here, we investigate the magnetic properties of exfoliated thin flakes of vdW magnet Fe 5 GeTe 2 via quantum magnetic imaging technique based on nitrogen vacancy centers in diamond. Through imaging the stray fields, we confirm room-temperature magnetic order in Fe 5 GeTe 2 thin flakes with thickness down to 7 units cell. The stray field patterns and their response to magnetizing fields with different polarities is consistent with previously reported perpendicular easy-axis anisotropy. Furthermore, we perform imaging at different temperatures and determine the Curie temperature of the flakes at ≈300 K. These results provide the basis for realizing a room-temperature monolayer ferromagnet with Fe 5 GeTe 2 . This work also demonstrates that the imaging technique enables rapid screening of multiple flakes simultaneously as well as time-resolved imaging for monitoring time-dependent magnetic behaviors, thereby paving the way towards high throughput characterization of potential two-dimensional (2D) magnets near room temperature and providing critical insights into the evolution of domain behaviors in 2D magnets due to degradation.

2D magnet↗

Sketch on the structural geology and vulcanism in the Central High Plateau of the Bolivian Andes

The author has identified the following significant results. The Earth Resources Technology Satellite Program has as an objective the development of tectonic maps for Bolivia. Maps were prepared using the images of ERTS-1 in a preliminary study of alignments observed and rapidly interpreted in images 1010-14033-3-4-5-6-7 on a scale of 1:1,000,000, and later verified on the ground with corresponding fault zones. This information was not shown on existing geologial maps. The ERTS-1 imagery was used in volcanology research for drawing the regional limits of volcanic formations as soon as the alignment and the extent of the volcanoes could be determined. The extensive coverage of ERTS-1 images provides an excellent opportunity for developing studies of regional structures.

Brockmann, C. E.↗

Rapid enumeration of viable bacteria by image analysis

A direct viable counting method for enumerating viable bacteria was modified and made compatible with image analysis. A comparison was made between viable cell counts determined by the spread plate method and direct viable counts obtained using epifluorescence microscopy either manually or by automatic image analysis. Cultures of Escherichia coli, Salmonella typhimurium, Vibrio cholerae, Yersinia enterocolitica and Pseudomonas aeruginosa were incubated at 35 degrees C in a dilute nutrient medium containing nalidixic acid. Filtered samples were stained for epifluorescence microscopy and analysed manually as well as by image analysis. Cells enlarged after incubation were considered viable. The viable cell counts determined using image analysis were higher than those obtained by either the direct manual count of viable cells or spread plate methods. The volume of sample filtered or the number of cells in the original sample did not influence the efficiency of the method. However, the optimal concentration of nalidixic acid (2.5-20 micrograms ml-1) and length of incubation (4-8 h) varied with the culture tested. The results of this study showed that under optimal conditions, the modification of the direct viable count method in combination with image analysis microscopy provided an efficient and quantitative technique for counting viable bacteria in a short time.

Non-NASA Center↗

yourSky: rapid desktop access to custom astronomical image mosaics

The yourSky custom astronomical image mosaicking software has a web portal architecture that allows access via ordinary desktop computers with low bandwidth network connections to high performance and highly customizable mosaicking software deployed in a high performance computing and communications environment.

astronomical↗

Industrial X-Ray Imaging

In 1990, Lewis Research Center jointly sponsored a conference with the U.S. Air Force Wright Laboratory focused on high speed imaging. This conference, and early funding by Lewis Research Center, helped to spur work by Silicon Mountain Design, Inc. to break the performance barriers of imaging speed, resolution, and sensitivity through innovative technology. Later, under a Small Business Innovation Research contract with the Jet Propulsion Laboratory, the company designed a real-time image enhancing camera that yields superb, high quality images in 1/30th of a second while limiting distortion. The result is a rapidly available, enhanced image showing significantly greater detail compared to image processing executed on digital computers. Current applications include radiographic and pathology-based medicine, industrial imaging, x-ray inspection devices, and automated semiconductor inspection equipment.

Source record↗

Magnetospheric Radio Tomography: Observables, Algorithms, and Experimental Analysis

This grant supported research towards developing magnetospheric electron density and magnetic field remote sensing techniques via multistatic radio propagation and tomographic image reconstruction. This work was motivated by the need to better develop the basic technique of magnetospheric radio tomography, which holds substantial promise as a technology uniquely capable of imaging magnetic field and electron density in the magnetosphere on large scales with rapid cadence. Such images would provide an unprecedented and needed view into magnetospheric processes. By highlighting the systems-level interconnectedness of different regions, our understanding of space weather processes and ability to predict them would be dramatically enhanced. Three peer-reviewed publications and 5 conference presentations have resulted from this work, which supported 1 PhD student and 1 postdoctoral researcher. One more paper is in progress and will be submitted shortly. Because the main results of this research have been published or are soon to be published in refereed journal articles listed in the reference section of this document, we provide here an overview of the research and accomplishments without describing all of the details that are contained in the articles.

Cummer, Steven↗

Quantifying particle-scale 3D granular dynamics during rapid compaction from time-resolved in situ 2D x-ray images

Understanding the particle-scale dynamics of granular materials during rapid compaction and flow is of fundamental importance for manufacturing, planetary science, geology, and defense applications. Time-resolved 2D radiography and static 3D x-ray tomography are powerful in situ tools for studying particle-scale dynamics but provide detail only in 2D or with significant time-scale limitations, respectively. Here, we introduce a new method that uses 2D in situ x-ray imaging for determining time-resolved 3D particle-scale dynamics in rapidly compressed granular materials. The method employs initial particle packing structures obtained from x-ray tomography, a 2D x-ray image generation algorithm, and an optimization algorithm. We first describe and validate the method using finite element simulations. Furthermore, we then apply the technique to x-ray phase-contrast images obtained during rapid compaction of granular materials with varying particle morphology and sample thickness. The depth-resolved particle-scale dynamics reveal complex velocity and porosity fields evolving heterogeneously along and perpendicular to the compaction direction. We characterize these features, their fluctuations near the compaction front, and the compaction front thickness. Our technique can be applied to understanding granular dynamics during rapid compaction events, and rearrangements during slower, but non-quasi-static, flows.

36 MATERIALS SCIENCE↗

Transonic applications of the Wake Imaging System

The extension of a rapid flow field survey method (wake imaging system) originally developed for low speed wind tunnel operation, to transonic wind tunnel applications is discussed. The advantage of the system, beside the simplicity and low cost of the data acquisition system, is that the probe position data are recorded as an optical image of the actual sensor and thus are unaffected by the inevitable deflections of the probe support. This permits traversing systems which are deliberately flexible and have unusual motions. Two transverse drive systems are described and several typical data images are given.

Crowder, J. P.↗

Rapid simulations of hyperspectral near-field images of three-dimensional heterogeneous surfaces – part II

The modeling of the near-field interaction in the scattering-type scanning near-field optical microscope (s-SNOM) is rapidly advancing, although an accurate yet versatile modeling framework that can be easily adapted to various complex situations is still lacking. In this work, we propose a time-efficient numerical scheme in the quasi-electrostatic limit to capture the tip-sample interaction in the near field. This method considers an extended tip geometry, which is a significant advantage compared to the previously reported method based on the point-dipole approximation. Using this formalism, we investigate, among others, nontrivial questions such as uniaxial and biaxial anisotropy in the near-field interaction, the relationship between various experimental parameters (e.g. tip radius, tapping amplitude, etc.), and the tip-dependent spatial resolution. The demonstrated method further sheds light on the understanding of the contrast mechanism in s-SNOM imaging and spectroscopy, while also representing a valuable platform for future quantitative analysis of the experimental observations.

Chen, Xinzhong (ORCID:0000000261033848)↗

Autonomous convergence of STM control parameters using Bayesian optimization

Scanning tunneling microscopy (STM) is a widely used tool for atomic imaging of novel materials and their surface energetics. However, the optimization of the imaging conditions is a tedious process due to the extremely sensitive tip–surface interaction, thus limiting the throughput efficiency. In this paper, we deploy a machine learning (ML)-based framework to achieve optimal atomically resolved imaging conditions in real time. The experimental workflow leverages the Bayesian optimization (BO) method to rapidly improve the image quality, defined by the peak intensity in the Fourier space. The outcome of the BO prediction is incorporated into the microscope controls, i.e., the current setpoint and the tip bias, to dynamically improve the STM scan conditions. We present strategies to either selectively explore or exploit across the parameter space. As a result, suitable policies are developed for autonomous convergence of the control parameters. The ML-based framework serves as a general workflow methodology across a wide range of materials.

97 MATHEMATICS AND COMPUTING↗

AXEAP (ARGONNE X-RAY EMISSION PACKAGE)

Argonne X-ray Emission Package (AXEAP), a singular purpose software package for processing X-ray emission (XES) images collected with a 2-dimensional position sensitive pixel array detector, has been developed. AXEAP can rapidly convert XES image files into a spectral form by applying parallel computation and unsupervised machine learning to compute vast amount of image data. Special focus has been placed on designing user-friendly-interface for processing multiple edges, non-resonant and resonant x-ray emission image analysis, in order to make data processing quick and easy. AXEAP is free software and is written in MATLAB, armed with powerful libraries and toolboxes. The software runs on all common operating systems such as Linux, Window, and Mac.

SUN, CHENGJUN↗

Automatic detection of cataclysmic variables from SDSS images

Abstract Investigating rare and new objects have always been an important direction in astronomy. Cataclysmic variables (CVs) are ideal and natural celestial bodies for studying the accretion process of semi-detached binaries with accretion processes. However, the sample size of CVs must increase because a lager gap exists between the observational and the theoretical expanding CVs. Astronomy has entered the big data era and can provide massive images containing CV candidates. CVs as a type of faint celestial objects, are highly challenging to be identified directly from images using automatic manners. Deep learning has rapidly developed in intelligent image processing and has been widely applied in some astronomical fields with excellent detection results. YOLOX, as the latest YOLO framework, is advantageous in detecting small and dark targets. This work proposes an improved YOLOX-based framework according to the characteristics of CVs and Sloan Digital Sky Survey (SDSS) photometric images to train and verify the model to realise CV detection. We use the Convolutional Block Attention Module to increase the number of output features with the feature extraction network and adjust the feature fusion network to obtain fused features. Accordingly, the loss function is modified. Experimental results demonstrate that the improved model produces satisfactory results, with average accuracy (mean average Precision at 0.5) of 92.0%, Precision of 92.9%, Recall of 94.3%, and $F1-score$ of 93.6% on the test set. The proposed method can efficiently achieve the identification of CVs in test samples and search for CV candidates in unlabeled images. The image data vastly outnumber the spectra in the SDSS-released data. With supplementary follow-up observations or spectra, the proposed model can help astronomers in seeking and detecting CVs in a new manner to ensure that a more extensive CV catalog can be built. The proposed model may also be applied to the detection of other kinds of celestial objects.

Astronomy & Astrophysics↗

Methane Quantification Performance of the Quantitative Optical Gas Imaging (QOGI) System Using Single-Blind Controlled Release Assessment

Quantitative optical gas imaging (QOGI) system can rapidly quantify leaks detected by optical gas imaging (OGI) cameras across the oil and gas supply chain. A comprehensive evaluation of the QOGI system’s quantification capability is needed for the successful adoption of the technology. This study conducted single-blind experiments to examine the quantification performance of the FLIR QL320 QOGI system under near-field conditions at a pseudo-realistic, outdoor, controlled testing facility that mimics upstream and midstream natural gas operations. The study completed 357 individual measurements across 26 controlled releases and 71 camera positions for release rates between 0.1 kg Ch 4 /h and 2.9 kg Ch 4 /h of compressed natural gas (which accounts for more than 90% of typical component-level leaks in several production facilities). The majority (75%) of measurements were within a quantification factor of 3 (quantification error of –67% to 200%) with individual errors between –90% and 831%, which reduced to –79% to +297% when the mean of estimates of the same controlled release from multiple camera positions was considered. Performance improved with increasing release rate, using clear sky as plume background, and at wind speeds ≤1 mph relative to other measurement conditions.

42 ENGINEERING↗

Applying Deep Learning for Wildfire Identification: Economical and Accessible Solutions Leveraging Small Datasets

Wildfires significantly impact human health, air quality, visibility, weather, and climate change and cause substantial economic losses. While state and county-operated air quality monitors provide critical insights during wildfires, they are not available in all regions. This highlights the need for affordable, accessible tools that allow the general public to assess air quality impacts. In this study, we apply machine learning with deep neural networks to diagnose air quality rapidly from sky images taken at the Pacific Northwest National Laboratory in Richland, WA, USA. Using a convolutional neural network (CNN) framework, we trained a deep learning model to classify air quality indices based on sky images. By leveraging transfer learning, our approach fine-tunes a pre-trained model on a small dataset of sky images, significantly reducing training time while maintaining high accuracy. Our results demonstrate the potential of deep learning to provide rapid air quality diagnostics during wildfire episodes, offering early warnings to the public and enabling timely mitigation strategies, particularly for vulnerable populations. Additionally, we show that lower respiratory infections pose the highest health risk during acute smoke exposures. Reactive oxygen species (ROS) from wildfire particles further exacerbate health risks by triggering inflammation and other adverse effects.

54 ENVIRONMENTAL SCIENCES↗

Deep Learning Analysis of Polaritonic Wave Images

Deep learning (DL) is an emerging analysis tool across the sciences and engineering. Encouraged by the successes of DL in revealing quantitative trends in massive imaging data, we applied this approach to nanoscale deeply subdiffractional images of propagating polaritonic waves in complex materials. Utilizing the convolutional neural network (CNN), we developed a practical protocol for the rapid regression of images that quantifies the wavelength and the quality factor of polaritonic waves. Using simulated near-field images as training data, the CNN can be made to simultaneously extract polaritonic characteristics and material parameters in a time scale that is at least 3 orders of magnitude faster than common fitting/processing procedures. The CNN-based analysis was validated by examining the experimental near-field images of charge-transfer plasmon polaritons at graphene/α-RuCl3 interfaces. Our work provides a general framework for extracting quantitative information from images generated with a variety of scanning probe methods.

97 MATHEMATICS AND COMPUTING↗

An edge preserving differential image coding scheme

Differential encoding techniques are fast and easy to implement. However, a major problem with the use of differential encoding for images is the rapid edge degradation encountered when using such systems. This makes differential encoding techniques of limited utility especially when coding medical or scientific images, where edge preservation is of utmost importance. We present a simple, easy to implement differential image coding system with excellent edge preservation properties. The coding system can be used over variable rate channels which makes it especially attractive for use in the packet network environment.

Rost, Martin C.↗