Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

Resonance Raman and surface- and tip-enhanced Raman spectroscopy methods to study solid catalysts and heterogeneous catalytic reactions.

Resonance Raman (RR) spectroscopy has several advantages over the normal Raman spectroscopy (RS) widely used for in situ characterization of solid catalysts and catalytic reactions. Compared with RS, RR can provide much higher sensitivity and selectivity in detecting catalytically-significant surface metal oxides. RR can potentially give useful information on the nature of excited states relevant to photocatalysis and on the anharmonic potential of the ground state. In this critical review a detailed discussion is presented on several types of RR experimental systems, three distinct sources of so-called Raman (fluorescence) background, detection limits for RR compared to other techniques (EXAFS, PM-IRAS, SFG), and three well-known methods to assign UV-vis absorption bands and a band-specific unified method that is derived mainly from RR results. In addition, the virtues and challenges of surface-enhanced Raman spectroscopy (SERS) are discussed for detecting molecular adsorbates at catalytically relevant interfaces. Tip-enhanced Raman spectroscopy (TERS), which is a combination of SERS and near-field scanning probe microscopy and has the capability of probing molecular adsorbates at specific catalytic sites with an enormous surface sensitivity and nanometre spatial resolution, is also reviewed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon Raman Spectroscopy of 36 Inter-Planetary Dust Particles

Carbon Raman spectroscopy is a useful tool to determine the degree of order of organic material (OM) in extra-terrestrial matter. As shown for meteoritic OM [e.g., 2], peak parameters of D and G bands are a measure of thermal alteration, causing graphitization (order), and amorphization, e.g. during protoplanetary irradiation, causing disorder. Th e most pristine interplanetary dust particles (IDPs) may come from comets. However, their exact provenance is unknown. IDP collection during Earth?s passage through comet Grigg-Skjellerup?s dust stream ("GSC" collectors) may increase the probability of collecting fresh IDPs from a known, cometary source. We used Raman spectroscopy to compare 21 GSC-IDPs with 15 IDPs collected at different periods, and found that the variation among GSC-IDPs is larger than among non-GSC IDPs, with the most primitive IDPs being mostly GSC-IDPs.

Busemann, H.↗

Raman spectroscopy of zirconium hydride

The characterization of zirconium hydride is important in the nuclear industry because of the hydrogen-induced embrittlement of Zircaloy cladding and its use as a neutron moderator. This paper introduces the use of Raman spectroscopy for the characterization of zirconium hydride. First-principles density functional theory (DFT) calculations were used to predict the Raman spectra of ζ-ZrH 0.5 , γ-ZrH, δ-ZrH 1.5 , δ-ZrH 1.66 , and ε-ZrH 2 with all their predicted symmetries; ζ-ZrH 0.5 (P3m1, R$\overline{3}$m, C2/m, Cm, Cmmm, and Pn$\overline{3}$m); γ-ZrH (P222, Ccce, and P4 2 /mmc); δ-ZrH 1.5 (P$\overline{4}$m2, P4 2 /mcm, Fmmm, Pn$\overline{3}$m, Ibam, P2/c, PI, and P4 2 /nnm); δ-ZrH 1.66 (Fm$\overline{3}$m); and ε-ZrH 2 (Fm$\overline{3}$m, R$\overline{3}$m, and I 4 /mmm). Two samples of Zircaloy-4 containing 133 wt ppm and 360 wt ppm hydrogen were characterized by Raman spectroscopy, showing two signal lines at 215 cm -1 and 1,187 cm -1 , which were assigned to the presence of δ-ZrH 1.66 . These signals had a good spatial correlation with visible hydride precipitates in Raman spectroscopy images. In conclusion, this work provides the basis for the characterization of all possible zirconium hydride compositions and structures using Raman spectroscopy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Spiers Memorial Lecture : Surface-enhanced Raman spectroscopy: from single particle/molecule spectroscopy to ångstrom-scale spatial resolution and femtosecond time resolution

Four decades on, surface-enhanced Raman spectroscopy (SERS) continues to be a vibrant field of research that is growing (approximately) exponentially in scope and applicability while pushing at the ultimate limits of sensitivity, spatial resolution, and time resolution. This introductory paper discusses some aspects related to all four of the themes for this Faraday Discussion. First, the wavelength-scanned SERS excitation spectroscopy (WS-SERES) of single nanosphere oligomers ( viz. , dimers, trimers, etc. ), the distance dependence of SERS, the magnitude of the chemical enhancement mechanism, and the progress toward developing surface-enhanced femtosecond stimulated Raman spectroscopy (SE-FSRS) are discussed. Second, our efforts to develop a continuous, minimally invasive, in vivo glucose sensor based on SERS are highlighted. Third, some aspects of our recent work in single molecule SERS and the translation of that effort to ångstrom-scale spatial resolution in ultrahigh vacuum tip-enhanced Raman spectroscopy (UHV-TERS) and single molecule electrochemistry using electrochemical (EC)-TERS will be presented. Finally, we provide an overview of analytical SERS with our viewpoints on SERS substrates, approaches to address the analyte generality problem ( i.e. target molecules that do not spontaneously adsorb and/or have Raman cross sections <10 -29 cm 2 sr -1 ), SERS for catalysis, and deep UV-SERS.

Chemistry↗

Simultaneous Conoscopic Holography and Raman Spectroscopy

A new instrument was developed for chemical characterization of surfaces that combines the analytical power of Raman spectroscopy with the three-dimensional topographic information provided by conoscopic holography. The figure schematically depicts the proposed hybrid instrument. The output of the conoscopic holographic portion of the instrument is a topographical map of the surface; the output of the Raman portion of the instrument is hyperspectral Raman data, from which the chemical and/or biological composition of the surface would be deduced. By virtue of the basic principles of design and operation of the instrument, the hyperspectral image data would be inherently spatially registered with the topographical data. In conoscopic holography, the object and reference beams of classical holography are replaced by the ordinary and extraordinary components generated by a single beam traveling through a birefringent, uniaxial crystal. In the basic conoscopic configuration, a laser light is projected onto a specimen and the resulting illuminated spot becomes a point source of diffuse light that propagates in every direction. The laser beam is rasterscanned in two dimensions (x and y) perpendicular to the beam axis (z), and at each x,y location, the pattern of interference between the ordinary and extraordinary rays is recorded. The recorded interferogram constitutes the conoscopic hologram. Of particular significance for the proposed instrument is that the conoscopic hologram contains information on the z coordinate (height) of the illuminated surface spot. Hence, a topographical map of the specimen is constructed point-by-point by rastering the laser beam in the x and y directions and correlating the x and y coordinates with the z information obtained from the interferograms. Conoscopic imaging is an established method, and conoscopic laboratory instruments for surface metrology are commercially available. In Raman spectroscopy of a surface, one measures the spectrum of laser light scattered inelastically from a laser-illuminated spot on the surface. The wavelengths of the inelastically scattered light differ from that of the incident laser beam by amounts that correspond to the energies of molecular vibrations. The resulting vibrational spectrum can be used to identify the molecules. Raman spectroscopy is a standard laboratory technique for identifying mineralogical, biological, and other specific chemical compositions.

Schramm, Harry F.↗

Raman spectroscopy of uranium nitride kernels

Uranium nitride is an advanced fuel candidate for a wide variety of advanced nuclear reactors. This work summarizes the first characterization of UN kernels by Raman spectroscopy. First-principles density functional theory calculations were performed to predict the Raman spectra of uranium sesquinitride (U 2 N 3 ), uranium dinitride (UN 2 ), uranium mononitride (UN), uranium monocarbide (UC), as well as U-N-C (UN 1-x C x ) and a U-N-C-O mixture. Further, a core–shell structure was identified by scanning electron microscopy and Raman spectroscopy imaging. A signal at ~500 cm -1 was identified on the periphery of the core-shell structure, possibly corresponding to U 2 N 3 and/or UN 2 . This signal broadens and shifts to 470 cm -1 because of the formation of UNC, UNCO or U 2 N 3+x structures. The culmination of this work demonstrates the feasibility of using Raman spectroscopy to identify variations in composition and phases in UN kernels.

36 MATERIALS SCIENCE↗

Phase transitions of cesium azide at pressures up to 30 GPa studied using in situ Raman spectroscopy

Cesium azide has been studied by Raman spectroscopy at pressures up to ≈30 GPa at room temperature. The sequence of phase transitions to Phase III (at 0.5 GPa), Phase IV (at 4.3 GPa), and Phase V (at ≈19 GPa) has been observed in agreement with recent X-ray diffraction studies. Phase III has been found to adopt a monoclinic C2/m structure with two azide anions in nonequivalent positions, where one set of azide anions appears to be orientationally disordered according to the observed Raman spectra. The transition to Phase IV has been associated with orientational ordering of azide anions, while the transition to Phase V has been shown to proceed with a lowering of crystal symmetry. Moreover, spectroscopic features indicate a possible change of bonding in CsN{sub 3} toward formation of covalent bonds at high pressures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scanning angle Raman spectroscopy: A nondestructive method for simultaneously determining mixed polymer fractional composition and film thickness

A scanning angle (SA) Raman spectroscopy method was developed to simultaneously measure the chemical composition and thickness of waveguide mixed polymer films with varying fractional compositions. In order to test the method, six films of polystyrene-block-poly(methyl methacrylate), some mixed with poly(methyl methacrylate) homopolymer (PS-b-PMMA:PMMA), and two films of poly(2-vinylnapthalene)-block-poly(methyl methacrylate) (P2VN-b-PMMA) were prepared. The film thickness ranged from 495 to 971 nm. The chemical composition and thickness of PS-b-PMMA:PMMA films was varied by the addition of the PMMA homopolymer and annealing the films in toluene. SA Raman peak amplitude ratios (1001 cm -1 for PS, 812 cm -1 for PMMA, and 1388 cm -1 for P2VN) were used to calculate the refractive index of the polymer film, an input parameter in calculations of the sum square electric field (SSEF). The film thickness was determined by SSEF models of the experimental Raman amplitudes versus the incident angle of light. The average film thickness determined by the developed SA Raman spectroscopy method was within 5% of the value determined by optical profilometry. In conclusion, SA Raman spectroscopy will be useful for in situ label-free analyses of mixed polymer waveguide films.

36 MATERIALS SCIENCE↗

Deciphering decomposition pathways of high explosives with cryogenic X-ray Raman spectroscopy

We employed cryogenic X-ray Raman spectroscopy to investigate the early-stage decomposition of the high explosive molecule hexanitrohexaazaisowurtzitane (CL-20). By systematically varying the radiation dose under cryogenic conditions, we induced the decomposition of the molecule using ionizing radiation and observed the evolution of spectral features at the carbon, nitrogen, and oxygen K edges. Through extensive first-principles calculations, we identified key intermediates in the early stages of the decomposition process, resulting from C–C and C–N bond cleavage which leads to the opening of the internal cage structure. A detailed analysis of spectral trends and fingerprints provided evidence supporting N–NO 2 homolytic cleavage as the primary initial decomposition pathway. The combination of advanced core-level spectroscopy methods and state-of-the-art theoretical calculations enabled a comprehensive characterization of the molecular changes induced by controlled radiation dose exposures. In conclusion, our findings establish a benchmark for understanding the decomposition chemistry of high-explosive materials, offering important insights into their stability and reactivity under extreme conditions.

X-ray Raman spectroscopy↗

Raman spectroscopy coupled with ambient ionization mass spectrometry: A forensic laboratory investigation into rapid and simple dual instrumental analysis techniques

We present a laboratory experiment, developed around a pair of instrumental analysis techniques, Raman spectroscopy and ambient ionization mass spectrometry (MS), conducted by senior chemistry undergraduate students for bulk analysis of over-the-counter drugs using benchtop versions of the two instruments, as well as trace analysis of illicit drugs utilizing the corresponding portable instruments. The identification and confirmation of seized drugs is a routine operation in forensic laboratories that can be simplified using these two instrumental techniques in tandem. Bulk samples are readily analyzed using conventional Raman spectroscopy followed by paper cone spray ionization (PCSI) MS, while trace analysis is allowed by a simple single-substrate dual-analyzer method using surface enhanced Raman spectroscopy (SERS) from paper followed by paper spray ionization (PSI) MS. The introduction of these novel strategies to the students exposed them to potential career paths in forensic science by means of a hands-on experience that provided fundamental knowledge about this set of analytical methods, including intercomparisons of their performance, as well as practical issues like costs, regulations and databases. The use of portable instrumentation represents an additional learning experience for the students, considering that it is cutting-edge technology that is just now being transferred from academic to industrial labs and that it allows a valuable discussion of the advantages and disadvantages of bringing the laboratory to the field.

47 OTHER INSTRUMENTATION↗

Microstructure and defects probed by Raman spectroscopy in lithium niobate crystals and devices

Raman microprobe applied on LiNbO{sub 3} (LN) crystals and derived materials or devices is shown to be a tool to detect either local variations or changes of the whole structure. Position, width, or intensity of one Raman line can be used as markers of a structural change. Indeed, each Raman line can be assigned to a peculiar ionic motion and is differently sensitive to application of strain, temperature change, and electric field. Some vibrational modes are especially associated to the site of Li ion, or Nb ion, or still oxygen octahedron, so that they can be affected by the introduction of dopant ion on one or another site. Therefore, Raman Spectroscopy (RS) can be used as a site spectroscopy to describe the mechanism of doping incorporation in the LN lattice, allowing the optimization of some linear and non-linear optical properties according to the dopant concentration and substitution site. The composition or the content of non-stoichiometry related defects could be derived from the width of some lines. Any damage or local disorder can be detected by a line broadening. The quality or preservation of the structure after chemical treatment, or laser pulses, can be thus checked. The structure of ion-implanted or proton-exchanged wave-guides and periodically poled lithium niobate as well can be imaged from frequency shift or intensity change of some lines. RS is thus a useful way to control the structure of LN and/or to optimize the preparation parameters and its properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of Raman Spectroscopy to Determine Uranium Content in ADUN Solution

The work presented in this report is part of the ongoing efforts to address the nuclear material control and accounting needs for advanced reactor fuel fabrication facilities. This work was supported by the Materials Protection, Accounting, and Control Technologies (MPACT) program under the US Department of Energy Office of Nuclear Energy‘s Nuclear Fuel Cycle and Supply Chain program. The activities and engagements under the MPACT program are designed to support a robust US civilian nuclear energy enterprise. In the work described in this report, we supported MPACT objectives by developing measurement techniques that could be used for material accounting and process monitoring and by working with industry partners to identify existing gaps and areas for improvement. Oak Ridge National Laboratory has been working with commercial tristructural isotropic (TRISO) fuel fabricators such as Standard Nuclear to develop technology for rapid and cost-effective uranium content assessment. This work has focused on demonstrating advanced measurement techniques (e.g., Raman spectroscopy) that can be used for rapid, reliable, and cost-effective routine measurements of uranium content in feed solutions and liquid waste streams as well as for monitoring in-line process measurements and product streams. Specifically, this report explores techniques for accurately determining uranium content in acid-deficient uranyl nitrate (ADUN) solutions and detecting low uranium concentrations in ammonia solutions. Developing such measurement techniques will benefit TRISO fuel fabrication facilities, facilities involved in other parts of the fuel cycle that require online monitoring of aqueous solutions, and potentially molten salt fuel reactors. This work supports developing Raman spectroscopy procedures to determine uranium concentrations in ADUN solutions, which are used as feedstock in the sol–gel process for creating TRISO fuel. Some additional benefits of using Raman spectroscopy for uranium quantification in fabrication facilities include enabling online monitoring of the chemical process, which would provide near real-time feedback; eliminating the need for sample transfers, preparation, or dilution; providing nondestructive measurements; and user friendliness. In this fiscal year, FY25, we determined the identity of the unknown Raman band at approximately 853 cm−1 that was discovered in ADUN Raman spectra in FY24, created calibration curves and determined uranium concentrations of two ADUN solutions, and compared the Raman results to results obtained from inductively coupled plasma mass spectrometry and Davies–Gray titration. Furthermore, we have identified focus areas for experimentation in future fiscal years. A key result is that the accuracy of using Raman can provide accuracy comparable to destructive analysist techniques, With a well-developed calibration curve, using standards and a large number of samples (more than five samples), uncertainty on the order of 1%–3% is achievable. Given that the uncertainties achieved by Raman spectroscopy were on the order of the uncertainties achieved using ICP-MS, we conclude that with a well-developed procedure Raman spectroscopy can be used to determine uranium concentrations in ADUN solutions for NMC&A applications. The benefits of such an approach are that the time and effort will be less than that of comparable destructive analysis techniques, with approximately the same level of technical expertise. This will be attractive to operators of fuel fabrication facilities as it will lower costs and improve efficiencies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

5f covalency from x-ray resonant Raman spectroscopy

Here, X-ray resonant Raman spectroscopy (XRRS), a variant of resonant inelastic x-ray scattering, has been used to investigate the two prototype systems, UF 4 and UO 2 . Both are U5f 2 and each is an example of 5f localized, ionic behavior and 5f localized, covalent behavior, respectively. From the M 5 XRRS measurements, the 5f band gap in each can be directly determined and, moreover, a clear and powerful sensitivity to 5f covalency emerges.

36 MATERIALS SCIENCE↗

Reduction of Raman Spectroscopy Data for H2-CO2-Air Tubular Flame Measurements

An approach of reducing spontaneous Raman spectroscopy data, based on the matrix inversion method which logically removes undesired sources of the Raman scattering signals including cross-talk due to the signals from other species, is discussed. The approach contains extensive calibration of temperature-dependent system response. The Raman spectra of several cold and hot calibration flames and their resulting calibration matrix are elaborated. The structure of H2-CO2-air tubular flames, in terms of major species (CO2, O2, N2, H2O, and H2) concentrations and temperature, was successfully measured with the optical technique. The Raman spectra data used in this study are taken from a uniquely designed experimental apparatus – a tubular burner and Raman spectroscopy system at Vanderbilt University. The characteristic uncertainties for chemical species are approximately ±2% by mole fraction for hot products and ±0.5% for room temperature reactants. The approach described here for hydrogen/air tubular flames may be adapted to hydrocarbon/air tubular flames when other necessary major species, for example, CH4 and CO for methane/air tubular flame, are considered in the whole process.

Raman Spectroscopy↗

Orientation-resolved domain mapping in tetragonal SrTiO 3 using polarized Raman spectroscopy

Here, we present microscopically resolved, polarized spectroscopy of Raman scattering collected from tetragonal SrTiO 3 . The anisotropic response of first-order Raman peaks within a single tetragonal domain has been measured. From these data, we assign symmetries to the phonons seen in the first-order Raman spectrum which is normally complicated by uncontrolled domain structure. Using a translation stage, we map the local domain orientation of a 3–μm 3 crystal volume near the laser focus and compare it to wide-field polarized images. This technique can be performed with readily available instruments and is relevant to the study of a wide range of related materials, interfaces, and devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasmonic Hybrid Biocomposite as an Effective Substrate for Detection of Biomolecules by Surface-Enhanced Raman Spectroscopy

The enhancement of the Raman light scattering signal from the surface of the porous hybrid biocomposites based on polyhydroxybutyrate (PHB), calcium carbonate (CaCO{sub 3}), and nanoplasmonic Ag particles is investigated. Based on PHB, fibrous scaffolds are obtained by the electrospinning technique. The fibrous scaffolds have been covered by CaCO{sub 3} and Ag nanoparticles by means of mineralization in salt solutions and Ag reduction reaction. Successful formation of the CaCO{sub 3} and Ag nanoparticles on the scaffold surface has been confirmed by the data of scanning electron microscopy, x-ray diffraction analysis, and infrared spectroscopy. Surface-enhanced Raman spectroscopy (SERS) of the obtained sample surface has demonstrated a significant enhancement of the Rhodamine 6G signal (E{sub f} > 10{sup 5}) in comparison with the reference sample where the analyte concentration and the laser power were 100 times higher. Thus, the present research has confirmed prospects for the application of biocomposites based on polyhydroxybutyrate for detection and investigation of biomolecules by the SERS method.

36 MATERIALS SCIENCE↗