Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Development of low-cost welding procedures for thick sections of HY-150 steel

Low cost welding procedures were developed for welding 6-inch thick HY-150 steel to be used in the manufacture of large diameter motor case Y rings and nozzle attachment flanges. An extensive investigation was made of the mechanical and metallurgical properties and fracture toughness of HY-150 base plate and welds made with manual shielded metal arc process and semi-automatic gas metal arc process in the flat position. Transverse tensiles, all-weld metal tensiles, Charpy V-notch specimens and edge notched bend specimens were tested in the course of the program. In addition metallographic studies and hardness tests were performed on the weld, weld HAZ and base metal. The results of the work performed indicate that both the shielded metal arc and gas metal arc processes are capable of producing consistently sound welds as determined by radiographic and ultrasonic inspection. In addition, the weld metal, deposited by each process was found to exhibit a good combination of strength and toughness such that the selection of a rolled and welded procedure for fabricating rocket motor case components would appear to be technically feasible.

Schmidt, P. M.↗

Measurements of Irradiated Low Enriched Fuel with a Gamma-Ray Scanning System (ANIMMA 2023 Conference Presentation)

A gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. A Monte Carlo N-Particle code simulation of the system and the fuel were created with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector as well as all available fuel specifications. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing eight pellets of 0.74% enriched UO2 in zirconium alloy. This fuel rodlet was part of the Environment Rodlet Transient Test Apparatus (SERTTA) testing campaign in the Transient Reactor Test Facility (TREAT). These results were compared to simulated spectra to help characterize the detector model and establish fidelity. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel. This article documents the modeling, benchmarking measurements, and the calculated number of fissions per gram in the SERTTA-A rodlet which was previously irradiated at TREAT.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Irradiated Low-Enriched Uranium Fuel Measurements with a Gamma-Ray Scanning System

A gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. A Monte Carlo N-Particle code simulation of the system and the fuel were created with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector as well as all available fuel specifications. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing eight pellets of 0.74% enriched UO2 in zirconium alloy. This fuel rodlet was part of the Static Environment Rodlet Transient Test Apparatus (SERTTA) testing campaign in the Transient Reactor Test Facility (TREAT). These results were compared to simulated spectra to help characterize the detector model and establish fidelity. A goal of the system is to determine the number of fissions per gram of UO2 in the fuel. This paper documents the modeling of the system and the calculation of the number of fissions per gram along the axial length of the SERTTA-C rodlet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of Thermal NDT of Space Shuttle Materials at NASA

Since the Space Shuttle Columbia accident, NASA has focused on improving advanced NDE techniques for the Reinforced Carbon-Carbon (RCC) panels that comprise the orbiter's wing leading edge and nose cap. Various nondestructive inspection techniques have been used in the examination of the RCC, but thermography has emerged as an effective inspection alternative to more traditional methods. Thermography is a non-contact inspection method as compared to ultrasonic techniques which typically require the use of a coupling medium between the transducer and material. Like radiographic techniques, thermography can inspect large areas, but has the advantage of minimal safety concerns and the ability for single-sided measurements. Details of the analysis technique that has been developed to allow insitu inspection of a majority of shuttle RCC components is discussed. Additionally, validation testing, performed to quantify the performance of the system, will be discussed. Finally, the results of applying this technology to the Space Shuttle Discovery after its return from the STS-114 mission in July 2005 are discussed.

Cramer, K. Elliott↗

Status of Thermal NDT of Space Shuttle Materials at NASA

Since the Space Shuttle Columbia accident, NASA has focused on improving advanced NDE techniques for the Reinforced Carbon-Carbon (RCC) panels that comprise the orbiter s wing leading edge and nose cap. Various nondestructive inspection techniques have been used in the examination of the RCC, but thermography has emerged as an effective inspection alternative to more traditional methods. Thermography is a non-contact inspection method as compared to ultrasonic techniques which typically require the use of a coupling medium between the transducer and material. Like radiographic techniques, thermography can inspect large areas, but has the advantage of minimal safety concerns and the ability for single-sided measurements. Details of the analysis technique that has been developed to allow insitu inspection of a majority of shuttle RCC components is discussed. Additionally, validation testing, performed to quantify the performance of the system, will be discussed. Finally, the results of applying this technology to the Space Shuttle Discovery after its return from the STS-114 mission in July 2005 are discussed.

Cramer, K. Elliott↗

Status of Thermal NDT of Space Shuttle Materials at NASA

Since the Space Shuttle Columbia accident, NASA has focused on improving advanced nondestructive evaluation (NDE) techniques for the Reinforced Carbon-Carbon (RCC) panels that comprise the orbiter's wing leading edge and nose cap. Various nondestructive inspection techniques have been used in the examination of the RCC, but thermography has emerged as an effective inspection alternative to more traditional methods. Thermography is a non-contact inspection method as compared to ultrasonic techniques which typically require the use of a coupling medium between the transducer and material. Like radiographic techniques, thermography can inspect large areas, but has the advantage of minimal safety concerns and the ability for single-sided measurements. Details of the analysis technique that has been developed to allow insitu inspection of a majority of shuttle RCC components is discussed. Additionally, validation testing, performed to quantify the performance of the system, will be discussed. Finally, the results of applying this technology to the Space Shuttle Discovery after its return from the STS-114 mission in July 2005 are discussed.

Cramer, K. Elliott↗

First Results from Diamagnetic Loop Measurements of the DARHT-I Electron Beam [Slides]

Diamagnetic-loop (DML) measurements can inform efforts to improve radiographic resolution. DML is non-invasive, so time-resolved data is available on every shot while tuning or executing a hydrotest. The time-resolved beam size can be deduced from the DML data. LIA beam-transport dynamics affecting beam size can be monitored while testing mitigation measures (e.g., beam halo suppression). Time-resolved beam size at final focus provides immediate information about spot size enlargement due to blur, and effectiveness of mitigation efforts. DML measures magnetic flux produced by a rotating beam, so it also enables monitoring of Larmor emittance that can enlarge the spot size. Beam rotation adds in quadrature with emittance, hence “Larmor emittance." Observing zero bias-field DML flux monitors beam rotation resulting from imperfect nulling of flux linking the cathode, and/or broken LIA transport symmetry (e.g., steering, quads, etc.).

43 PARTICLE ACCELERATORS↗

The 6-minute walk test predicts mortality in a pulmonary nontuberculous mycobacteria-predominant bronchiectasis cohort

Background: Bronchiectasis is a chronic lung condition frequently associated with nontuberculous mycobacteria pulmonary (NTM) disease. Persons with these conditions are at increased risk of mortality. Patient reported outcome (PRO) instruments and the 6-minute walk test (6MWT) have been shown to predict mortality for several lung conditions, but these measures have not been fully evaluated for bronchiectasis and NTM. Methods: We conducted a retrospective cohort study among adult patients enrolled in a natural history study of bronchiectasis at the National Heart, Lung, and Blood Institute. Electronic medical records were queried for demographic, clinical, microbiologic, radiographic, and PRO instrument data: St. George’s Respiratory Questionnaire (SGRQ), Medical Research Council Dyspnea Scale, and the Pulmonary Symptom Severity Score (PSSS). The study baseline date was defined as the patient’s first visit after January 1st, 2015 with a SGRQ or 6MWT completed. Follow-up was defined as the interval between the study baseline visit and date of death or December 31st, 2019. Sex-stratified Cox proportional-hazards regression was conducted to identify predictors of mortality. Separate models were run for each PRO and 6MWT measure, controlling for age, body mass index (BMI), fibrocavitary disease status, and M. abscessus infection. Results: In multivariable Cox proportional-hazards regression models, the PSSS-severity (aHR 1.29, 95% CI 1.04–1.59), the 6MWT total distance walked (aHR 0.938, 95% CI 0.896–0.981) and distance saturation product (aHR 0.930, 95% CI 0.887–0.974) independently predicted mortality. In addition, BMI was significantly predictive of mortality in all models. Conclusions: The 6MWT and a PRO instrument capturing symptom severity are independently predictive of mortality in our cohort of bronchiectasis patients.

6-minute walk test↗

Experimental study of void formation during aluminum solidification in reduced gravity

Void formation due to volumetric shrinkage and liquid/vapor reorientation during aluminum solidification was observed in real time by using a radiographic viewing system in normal and reduced gravity. An end-chill directional solidification furnace with water quench was designed and constructed to solidify aluminum samples during the approximately 16 sec of reduced gravity (+/-0.02g) achieved by flying an aircraft through a parabolic trajectory. In the first series of tests the aluminum was contained in a vacuum sealed, pyrolytic boron nitride crucible. An ullage space was present during each test. Void formation was recorded for two cases: a nonwetting system, and a wetting system where wetting occurred between the aluminum and the crucible lid. The void formation in the nonwetting case was similar in normal and reduced gravity, with a single vapor cavity forming at the top of the crucible. In the wetting case during reduced gravity surface tension caused two voids to form in the top corners of the crucible, but during normal gravity only one large void formed across the top. In the second series of tests the aluminum was contained in a pyrolytic boron nitride crucible that was placed in a stainless steel container and sealed in an environment of argon plus 4 percent hydrogen. An ullage space was present during each test. Void formation was recorded for two cases: a nonwetting system, and a wetting system where wetting occurred between the aluminum and one side wall and the lid. The void for nation in the nonwetting case was similar in normal and reduced gravity, with a single vapor cavity forming at the top of the crucible, although the meniscus became more convex in reduced gravity. In the wetting case the aluminum did not climb up the corners in 1g, and one large symmetric void resulted at the top when the aluminum had solidified. In the wetting case during reduced gravity the molten aluminum was drawn up the wetted wall and partially across the lid by a capillary underpressure; however, on the nonwetting wall the aluminum moved down. One void resulted along the nonwetting side of the container continuing to the top on the same side.

Chiaramonte, Francis Paul, III↗

Industrial Inspection System

ACTIS+ is a smaller, personal computer version of ACTIS, a computed tomography system which finds its origins in the Apollo lunar landing research. It is used to identify imperfections in aerospace structures and components. Designed to be added to an existing real time radiography system, its components include a high precision rotation/elevation manipulator, color image monitor, graphical user interface monitor, and PC compatible workstation. Cross-sectional CT images are more detailed than radiographic images and the high speed scanning feature offers the capability for 100 percent inspection in a production environment. Bio-Imaging Research, Inc. (BIR) originally developed ACTIS for Marshall Space Flight Center (MSFC), and commercial units were sold to aerospace manufacturers. The technology was refined for ACTIS+, which is principally used in non-destructive testing.

Source record↗

Debonding characteristics of adhesively bonded woven Kevlar composites

The fatigue damage mechanism of an adhesively bonded joint between fabric reinforced composite adherends was investigated with cracked-lap-shear specimens. Two bonded systems were studied: fabric Kevlar 49/5208 epoxy adherends bonded together with either EC 3445 or FM-300 adhesive. For each bonded system, two specimen geometries were tested. In all specimens tested, fatigue damage occurred in the form of cyclic debonding; however, the woven Kevlar specimens gave significantly slower debond growth rates and higher fracture toughness than previously found in the nonwoven adherend specimens. The surfaces for the woven adherends were not smooth; rather, they had regular crests (high spots) and troughs (low spots) due to the weave pattern. Radiographs of the specimens and examination of their failure surfaces revealed that fiber bridging occurred between the crests of the two adherends in the debonded region. The observed improvements in debond growth resistance and static fracture toughness are attributed to this bridging.

Mall, S.↗

Radiographic Imaging and Tomography

Radiographic imaging and tomography (RadIT) come in many flavors such as X-ray imaging and tomography (IT), proton IT, neutron IT, muon IT, neutrino IT, etc. We identify five RadIT themes: Physics, Sources, Detectors, Methods, and Data Science, which are integral parts of image interpretation and three-dimensional (3D) tomographic reconstruction. Traditionally, RadIT have been driven by medicine, non-destructive testing, material sciences, and security applications. The latest thrusts of growth come from automation, machine vision, additive manufacturing and virtual reality (‘metaverse’). The five RadIT themes parallel their counterparts in optical IT. Synergies among different forms of RadIT and with optical IT motivate further advances towards multi-modal IT and quantum IT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Radiographic Linear Indications and Subsequent Microstructural Features in Gas Tungsten Arc Welds of Inconel 718

This study presents examples and considerations for differentiating linear radiographic indications produced by gas tungsten arc welds in a 0.05-in-thick sheet of Inconel 718. A series of welds with different structural features, including the enigma indications and other defect indications such as lack of fusion and penetration, were produced, radiographed, and examined metallographically. The enigma indications were produced by a large columnar grain running along the center of the weld nugget occurring when the weld speed was reduced sufficiently below nominal. Examples of respective indications, including the effect of changing the x-ray source location, are presented as an aid to differentiation. Enigma, nominal, and hot-weld specimens were tensile tested to demonstrate the harmlessness of the enigma indication. Statistical analysis showed that there is no difference between the strengths of these three weld conditions.

Walley, J. L.↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

A Prototype Thick-Target Bremsstrahlung Model with Angularly-Dependent Emission in the MCNP6 ® Code

This document summarizes the current thick-target bremsstrahlung (TTB) model in MCNP and provides test results for an alternative implementation to improve the accuracy with reduced cost compared to full electron transport. It has been observed that the current TTB model produces inaccurate results in problems where the medium is thick with respect to electrons, but the photon distribution in the problem has a strong directionality. An example of such a simulation is detectors surrounding a metal target irradiated with a radiographic beam of high energy photons. The primary cause of this discrepancy is the current TTB method emits all bremsstrahlung photons in the same direction as the primary electron produced from each (γ, e ± ) interaction, leading to artificially forward peaked photon distributions for intermediate to high-energy incident photons. To improve the TTB model, we have implemented an angularly-dependent TTB model in a developer version of the MCNP6 ® code; for developers, this was done on the branch prototype/angular_ttb in the mcnp6 repo on bitbucket. The angularly-dependent TTB model accounts for the energy and scattering of electrons as they slow down in the current material, but does not sample the computationally expensive energy straggling, secondary electron events, and tracking electrons; this approach is significantly less computationally expensive than full electron transport and can be comparable to the original TTB method for problems with sufficiently complex materials and geometry. To evaluate the method, we have modeled a simple problem of a beam of 5 MeV photons incident on a sphere of plutonium surrounded by detectors at different deflection angles. For this problem, the angularly-dependent TTB produces a photon flux within 8.0% for a 90 degree deflection angle and 0.8% along the beam axis, as compared to the electron transport solution. This is an improvement compared to a 43% and 81% discrepancy with the original TTB method, respectively. The rest of this work includes the following: the first section details the current TTB treatment in MCNP, which has not been well documented elsewhere. Then, the modified TTB algorithm is detailed and the approximations compared to the condensed history algorithm are compared. Results are given comparing the two TTB methods to the condensed history transport algorithm. The appendix includes details for code developers on relevant electron transport implementation details and potential code improvements for future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Probe 23A Pre-Shot report

The Multi-Probe Radiography campaign will field a full day of experiments at the Omega EP laser facility. The experiments will consist of shots that alternate between Omega EP’s two short-pulse laser beams to generate proton and deuteron beams from a variety of film and foam targets. The proton beam is intended to be used as a radiographic source, while the deuteron beam will be used as the pitcher in a pitcher-catcher neutron-generation concept. For the proton beam, our goal is to characterize the angular distribution and energy spectra of unwanted x-rays that are generated during proton acceleration and were found to be problematic for simultaneous radiography in MP-22A. As part of this primary goal, we will test whether an x-ray shield, XBLK, can be used to prevent these x-rays from impacting other x-ray diagnostics. For the deuteron beam, our primary goal is to characterize the energy spectra and beam profile of deuterons accelerated from CD foils and foams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Engine materials characterization and damage monitoring by using x ray technologies

X ray attenuation measurement systems that are capable of characterizing density variations in monolithic ceramics and damage due to processing and/or mechanical testing in ceramic and intermetallic matrix composites are developed and applied. Noninvasive monitoring of damage accumulation and failure sequences in ceramic matrix composites is used during room-temperature tensile testing. This work resulted in the development of a point-scan digital radiography system and an in situ x ray material testing system. The former is used to characterize silicon carbide and silicon nitride specimens, and the latter is used to image the failure behavior of silicon-carbide-fiber-reinforced, reaction-bonded silicon nitride matrix composites. State-of-the-art x ray computed tomography is investigated to determine its capabilities and limitations in characterizing density variations of subscale engine components (e.g., a silicon carbide rotor, a silicon nitride blade, and a silicon-carbide-fiber-reinforced beta titanium matrix rod, rotor, and ring). Microfocus radiography, conventional radiography, scanning acoustic microscopy, and metallography are used to substantiate the x ray computed tomography findings. Point-scan digital radiography is a viable technique for characterizing density variations in monolithic ceramic specimens. But it is very limited and time consuming in characterizing ceramic matrix composites. Precise x ray attenuation measurements, reflecting minute density variations, are achieved by photon counting and by using microcollimators at the source and the detector. X ray computed tomography is found to be a unique x ray attenuation measurement technique capable of providing cross-sectional spatial density information in monolithic ceramics and metal matrix composites. X ray computed tomography is proven to accelerate generic composite component development. Radiographic evaluation before, during, and after loading shows the effect of preexisting volume flaws on the fracture behavior of composites. Results from one-, three-, five-, and eight-ply ceramic composite specimens show that x ray film radiography can monitor damage accumulation during tensile loading. Matrix cracking, fiber-matrix debonding, fiber bridging, and fiber pullout are imaged throughout the tensile loading of the specimens. In situ film radiography is found to be a practical technique for estimating interfacial shear strength between the silicon carbide fibers and the reaction-bonded silicon nitride matrix. It is concluded that pretest, in situ, and post-test x ray imaging can provide greater understanding of ceramic matrix composite mechanical behavior.

Baaklini, George Y.↗