Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Role of a Chemist in Modern Industries: Design and Development of Nanoengineered Multifunctional Materials

During the past fifteen years significant investment has been made for the applications of nanotechnology in almost every aspect of life. Almost every area of research has projected improvements including biotechnology, bioinspired electronic, optical and radiological sensors, or a promise for the emergence of some novel device technologies. For such applications major focus has been placed on research nanoparticles, nanotubes nanorods and two-dimensional structures similar to that of graphene. Some near- term applications of nano- particles and nanowires have produced very promising results for better synthesis of energy storage materials, design of biologically active composites like apatites, laser host crystals, photodetectors and sensor materials for radiation detection. To achieve desired morphologies, nanomaterials can be utilized some organic melt and orient the grains by the directional solidification method. The organic treated materials produce different characteristics than coarsened oxide materials. The focus is also understanding the morphology and performance function in human organs that occur because of aging or disease, and responses to interventions. We annealed to determine the changes in morphologies and hence effect of aging. In this presentation, we will discuss correlation between the designed composition, micromorphology and the performance parameters of nanomaterials. To understand the mechanism of formation of nanoparticles, nanoboloids, fibers experimental details and observations on the of multinary compounds will be presented. These observations on the transition of nanomorphology can highlight the mechanism of the phase transition in some oxides and selenides.

Singh, N. B.↗

Vapor Growth of Indium Monoiodide

Indium (I) iodide, InI, is part of a group of heavy metal iodides that can be used as room temperature radiation detectors. Other examples are HgI2, PbI2, BiI3, or TlPbI3. InI has several advantages, such as low toxicity, no solid phase transition (such as in HgI2), and no tendency to form polytypes (PbI2, BiI3 ). All binary iodides have layered structures and are quite soft, but InI is also the mechanically most stable compound of the binary compounds. Table 1 shows the main properties of InI in comparison with the other iodides and the most common room temperature radiation detector material, (Cd, Zn)Te. InI is typically grown by the unseeded Bridgman method using a nucleation tip, but Czochralski (CZ) growth has also been demonstrated. The resulting crystals have been used successfully for radiation detection, but both resistivity and mobility are usually well below theoretically predicted values. Physical vapor transport (PVT), although much slower than melt growth, is an alternative method and has been used to grow e.g. HgI2, PbI2, BiI3, CdTe. PVT growth should eliminate or reduce inclusions and impurities since it is based on sublimation, reduce intrinsic defects due to the lower growth temperature, and reduce dislocation densities due to reduced thermal and mechanical stress. As an example, PVT-grown CdTe showed a much improved structural quality compared to Bridgman- or THM-grown material.

Cröll, Arne↗

Technology for Space Optical Interferometry

The Micro-Precision Control/Structure Interaction (CSI) program at JPL is chartered to develop the structures and control technology needed for sub-micron level stabilization of future optical space systems. The extreme dimensional stability required for such systems derives from the need to maintain the alignment and figure of critical optical elements to a small fraction (typically 1/20th to 1/50th) of the wavelength of detected radiation (about 0.5 micron for visible light, 0.1 micron for ultraviolet light). This requirement is common to a broad class of optical sysetms. The challenge for CSI arises when such systems become large, with spatially distributed optical elements mounted on lightweight, flexible structure. This paper will present an overview of the approach that is being taken by JPL's CSI program to address this challenge. In particular, the paper will discuss the application of CSI technology to a specific example of a future large optical space mission. Experimental demonstration of the technology on ground-based testbeds will also be presented.

structures↗

Remote detection of CAT by infrared radiation

The remote detection of clear air turbulence (CAT) was investigated using an airborne scanning infrared spectrometer. Results of the flight tests indicated a high correlation between turbulence and temperature changes, and remote detection was obtained at distances up to 10 miles. Since CAT can extend horizontally over 50 miles, but is usually limited vertically to a few thousand feet, it is concluded that the best avoidance maneuver is a change in altitude.

Astheimer, R. W.↗

Simultaneous SMM flat crystal spectrometer and Very Large Array observations of solar active regions

High-resolution images of the quiescent emission from two solar active regions at 20 cm (VLA) and soft X-ray (SMM FCS) wavelengths are compared. There are regions where the X-ray coronal loops have been completely imaged at 20 cm wavelength. In other regions, the X-ray radiation was detected without detectable 20 cm radiation, and vice versa. The X-ray data were used to infer average electron temperatures of about 3-million K and average electron densities of about 2.5 x 10 to the 9th/cu cm for the X-ray emitting plasma in the two active regions. The thermal bremsstrahlung of the X-ray emitting plasma is optically thin at 20 cm wavelength. The 20 cm brightness temperatures were always less than T(e), which is consistent with optically thin bremsstrahlung. The low T(B) can be explained if a higher, cooler plasma covers the hotter X-ray emitting plasma. Thermal gyroresonance radiation must account for the intense 20 cm radiation near and above sunspots where no X-ray radiation is detected.

Lang, Kenneth R.↗

Considering Cell Proliferation to Optimize Detection of Radiation-induced 53BP1+ Foci in 15 Mouse Strains ex vivo

Due to high metabolic activity, proliferating cells continuously generate free radicals, which induce DNA double strand breaks (DSB). Fluorescently tagged nuclear foci of DNA repair protein 53 binding protein-1(53BP1) are used as a standard metric for measuring DSB formation at baseline and in response to environmental insults such as radiation. Here we demonstrate that the background level of spontaneous 53BP1+ foci formation can be modeled mathematically as a function of cell confluence, which is a metric of proliferation rate. This model was validated using spontaneous 53BP1+ foci data from 68 cultures of primary skin fibroblasts derived from 15 different strains of mice, showing a ~10 fold decrease from low to full confluence that is independent of mouse strain. We developed an online open access tool to correct for the impact of cell confluence on the detection of radiation-induced 53BP1+ foci (RIF). This tool provides guidelines for the number of cells required to reach statistical significance for the detection of excess foci induced by low doses of ionizing radiation as a function of confluence and time post-irradiation. We hope that this quantification tool will help the radiation biology community in the design of future experiments that utilize 53BP1+ foci-based quantification of radiation responses in vitro. Our “tool for enhanced results of RIF in cells” (terRIFic) can be found at: https://radbiolab.shinyapps.io/terrific/

Radiation, DNA damage, confluence↗

Radiation Tolerance and Mitigation for Neuromorphic Processors

Neuromorphic processors are designed to execute Deep Neural Networks (DNNs) at very high speed using only a fraction of the electrical power needed to run a DNN on a traditional CPU or GPU. This unique capability makes Neuromorphic processors a prime candidate for space systems, where advanced computational tasks like image analysis, depth map reconstruction, or rover control need to be executed in a power-starved environment. In contrast to the growing number of applications of Neuromorphic processors in smart phones, the automotive and robotics domain, the space environment is unforgiving because of extreme temperatures and high levels of radiation. Any space system, operating beyond LEO requires computing hardware that is resilient against radiation effects. However, Neuromorphic processors have not yet been designed or tested for their radiation tolerance. In this report, we consider traditional methods of detection of radiation events and mitigation via redundancy and gauge their effectiveness on DNNs. In contrast to traditional flight software, however, neural networks represent a statistical algorithm, which might affect its resilience against radiation events. We will focus on the analysis of the tolerance of DNNs with respect to radiation events and discuss techniques to detect radiation hits using on-chip triple modular redundancy (TMR) on an Intel Loihi neuromorphic processor and to mitigate radiation damage. We describe an architecture for on-chip TMR for the Intel Loihi and present results of initial experiments.

Neural Networks↗

Prospects for detection of gravitational radiation by simultaneous Doppler tracking of several spacecraft

This paper reports a calculation of the effect of gravitational radiation on the observed Doppler shift of a sinusoidal electromagnetic signal transmitted to, and coherently transponded from, distant spacecraft. It is found that the effect of plane gravitational waves on such observations is not intuitively immediate, and in fact depends sensitively on the spacecraft direction, which suggests the possibility of detecting such plane waves by simultaneous Doppler tracking of several spacecraft. The need for broad band gravitational wave observations, the required stabilities of time keeping standards, and astrophysical sources expected in the Very Low Frequency band are briefly discussed.

Estabrook, F. B.↗

A Method Based on Radiative Cooling for Detecting Structural Changes in Undercooled Metallic Liquids

We introduce a structure-sensitive parameter for undercooled melts which can be measured in containerless processing experiments. We have established that the ratio, R(T), of hemispherical total emissivity epsilon(sub T)(T) to constant-pressure specific heat c(sub p)(T) can serve as an indicator which is sensitive to any changes in short range atomic order in undercooled metallic melts. R(T) (triple bonds) epsilon(sub T)(T)/c(sub p)(T) values for nickel, zirconium, and silicon have been obtained using the high temperature electrostatic levitator while the levitated melts were undergoing purely radiative cooling into the deeply undercooled region. R(T) plots for undercooled liquid nickel and zirconium indicate no significant change in short-range structure from their melting temperatures to 15% undercooling. In contrast, liquid silicon shows marked short-range structural changes beginning above its melting temperature and extending throughout the undercooled region. The short-range structure of liquid silicon is related to the highly-directional covalent bonding which characterizes its solid form. The nickel and zirconium data show that epsilon(sub T) varies linearly with T, in support of metal emissivity theories.

Rulison, Aaron J.↗

Broadband optical radiation detector

A method and apparatus for detecting optical radiation by optically monitoring temperature changes in a microvolume caused by absorption of the optical radiation to be detected is described. More specifically, a thermal lens forming material is provided which has first and second opposite, substantially parallel surfaces. A reflective coating is formed on the first surface, and a radiation absorbing coating is formed on the reflective coating. Chopped, incoming optical radiation to be detected is directed to irradiate a small portion of the radiation absorbing coating. Heat generated in this small area is conducted to the lens forming material through the reflective coating, thereby raising the temperature of a small portion of the lens forming material and causing a thermal lens to be formed therein.

Gupta, A.↗

Detection of gravitational radiation and oscillations of the sun via Doppler tracking of spacecraft

The magnitude of Doppler signals produced by gravitational wave burst, continuous gravitational waves, and oscillations of the sun interacting with a spacecraft are considered. Expressions are worked out for the appropriate noise entering each measurement. The noise sources considered are the Doppler extractor, fluctuations in the solar wind and the troposphere, and fluctuations in the reference oscillator.

Douglas, D. H.↗

Direct detection of XUV radiation with a CCD

A thinned CCD illuminated from the back has been used for direct imaging in the 584 and 304 A resonance lines of helium and in the 736 A line of neon. During operation, the CCD was cooled to minus 10 C and output was displayed on a CRT screen or in numerical printout. The results demonstrate that the back-illuminated CCD can be used as a position-sensitive flux detector with good imaging properties over a wide range of photon energies, including the extreme ultraviolet.

Burstein, P.↗

Non-Invasive, Quantitative, and Remote Detection of Early Radiation Cataracts for Applications in Bio-Astronautics and Bio-Informatics

Human exploration of Mars may be a possibility in the next twenty years. Maintaining good vision is an essential aspect of achieving a successful mission. Continuous radiation exposure is a risk factor for radiation-induced cataracts in astronauts. A compact device based on the technique of dynamic light scattering (DLS) is designed for monitoring an astronaut's ocular health during long-duration space travel. Preliminary data on the simulated effects of ionizing radiation exposure to the ocular tissues of nonhuman animals and results on the sensitivity of DLS over established clinical procedures in investigating cataracts are presented. This capability of early diagnosis, unmatched by any other clinical technique in use today, may enable prompt initiation of preventive/curative therapy. An internet web based system integrating photon correlation data and controlling the hardware to monitor cataract development in vivo at a remote site in real time (teleophthalmology) is currently being developed. Cataract studies on-board the International Space Station (ISS) will be helpful in designing better protective radiation shields for future space vehicles and space suits.

Ansari, Rafat R.↗

X ray sensitive area detection device

A radiation sensitive area detection device is disclosed which comprises a phosphor-containing film capable of receiving and storing an image formed by a pattern of incoming x rays, UV, or other radiation falling on the film. The device is capable of fluorescing in response to stimulation by a light source in a manner directly proportional to the stored radiation pattern. The device includes: (1) a light source capable of projecting light or other appropriate electromagnetic wave on the film so as to cause it to fluoresce; (2) a means to focus the fluoresced light coming from the phosphor-containing film after light stimulation; and (3) at least one charged coupled detector or other detecting element capable of receiving and digitizing the pattern of fluoresced light coming from the phosphor-containing film. The device will be able to generate superior x ray images of high resolution from a crystal or other sample and will be particularly advantageous in that instantaneous near-real-time images of rapidly deteriorating samples can be obtained. Furthermore, the device can be made compact and sturdy, thus capable of carrying out x ray or other radiation imaging under a variety of conditions, including those experienced in space.

Carter, Daniel C.↗