Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Real-time Object Bounding in LiDAR Data With Computer Vision

The Multimodal Measurement System is a roadside radiation measurement testbed used to detect radiation sources in passing vehicles. It works by combining sensor signals from various modalities to produce a thorough scan of the source. A LiDAR sensor is used to measure the dimensions of the vehicle and provide a velocity estimate. However, the current LiDAR setup uses propriety software for which the source code is unavailable and cannot be updated to improve performance. Therefore, it is imperative to the accuracy of the analysis to create a custom vehicle detection that can return the dimensions and velocity of passing vehicles in real time. This new custom detection is written in C++ using the PointCloud Library, which keeps it lightweight. It also utilizes Docker and the Robot Operating System, which allows the versatility of running both on a small computer or the Lawrence Livermore National Laboratory cluster while utilizing different models of LiDAR sensors. The custom detection outperforms the current detection model, which increases the accuracy of radiation source detection.

97 MATHEMATICS AND COMPUTING↗

Data processing improvements for the Skylab S-191 EREP spectrometer

The characteristics of the S-191 spectrometer (filter wheel infrared spectrometer) are discussed. Inherent deficiencies in previous spectrometers are described and the techniques for correcting the deficiencies are explained. The radiance errors caused by error in wavelength are identified and the effects on the accuracy of the spectrometer are described. It is stated that the most important source of error in the S-191 spectrometer is off-band radiation in which the detected radiation is far from the wavelength which is expected to be detected by the sensor at that particular time. A numerical analysis of the effects of off-band radiation is developed.

Campbell, C. E.↗

Mixed Material Scintillator Systems for Neutron Detection

Scintillators are a fundamental technology that enables radiation detection. Their use has historically enabled the detection of incoming gamma radiation, with recent advances in plastic scintillator development enabling detection and discrimination of neutron and gamma radiation through pulse shape discrimination. However, scintillators have so far consisted of a single material, typically one primary dye and one secondary dye embedded in a plastic matrix. Based on the simulation studies described previously, mixed material scintillator systems with multiple secondary dyes arranged in alternating, periodic micro-sized regions opens the door for scintillators with a wide variety of different capability, such as directional sensing, positional reconstruction, particle identification, and pulse shape discrimination. However, fabrication of a mixed material scintillator system by conventional manufacturing methods is difficult to manufacture and scale, creating a barrier to their wide spread implementation. On the other hand, additive manufacturing additive manufacturing presents itself as the optimal method for fabricating mixed material scintillator systems based on its flexibility, ability to fabricate fine features, and potential for multimaterial fabrication.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Growth of High-Purity CsPbBr 3 Crystals for Enhanced Gamma-Ray Detection

High-quality CsPbBr 3 crystals hold significant potential for gamma-ray detection due to their remarkable optoelectronic properties. This study details an optimized production process using the Bridgman method to achieve highly pure CsPbBr 3 crystals. By implementing rigorous synthesis and purification techniques, we successfully reduced the total impurity levels to 9 ppm, as confirmed by glow discharge mass spectroscopy (GDMS). The resulting CsPbBr 3 crystals demonstrate exceptional performance, including high transparency, intense photoemission, and prolonged photoluminescence decay times. These properties facilitate superior gamma-ray detection with an energy resolution of 1.4% for the 137 Cs 662 keV gamma-rays, comparable to commercial Cd 1-x Zn x Te (CZT) detectors. Our findings underscore the critical relationship between material purity and detector performance, highlighting the potential of CsPbBr 3 as a cost-effective alternative in radiation detection applications. Further studies on defect origins and electronic states are necessary to fully leverage the capabilities of CsPbBr 3 crystals in practical high-energy radiation detection systems.

Bridgman↗

Confirming the absence of nuclear warheads via passive gamma-ray measurements

Arms-control agreements between the United States and Russia negotiated after the end of the Cold War have imposed limits on the number of deployed strategic nuclear weapons. Verification of these agreements has relied on onsite inspections, sometimes supported by radiation detection techniques to confirm the absence of a nuclear warhead when ambiguities arise. So far, these measurements have sought to detect neutron emissions associated with the presence of plutonium, but they would be inadequate for uranium devices. In an effort to offer instruments that could be used to confirm the absence of both plutonium and uranium weapons, here we propose an inspection system that uses only passive gamma radiation detection techniques. Such a system would be particularly valuable for next-generation arms-control agreements that limit total numbers of weapons and would involve containerized items in storage. We conducted extensive Monte Carlo simulations to support the development of a verification protocol and detection algorithm. Here, we demonstrate the viability of the technique using standard laboratory check sources and MCNP simulations for simplified configurations of special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Radiation sensitive area detection device and method

A radiation sensitive area detection device for use in conjunction with an X ray, ultraviolet or other radiation source is provided which comprises a phosphor containing film which releases a stored diffraction pattern image in response to incoming light or other electromagnetic wave. A light source such as a helium-neon laser, an optical fiber capable of directing light from the laser source onto the phosphor film and also capable of channelling the fluoresced light from the phosphor film to an integrating sphere which directs the light to a signal processing means including a light receiving means such as a photomultiplier tube. The signal processing means allows translation of the fluoresced light in order to detect the original pattern caused by the diffraction of the radiation by the original sample. The optical fiber is retained directly in front of the phosphor screen by a thin metal holder which moves up and down across the phosphor screen and which features a replaceable pinhole which allows easy adjustment of the resolution of the light projected onto the phosphor film. The device produces near real time images with high spatial resolution and without the distortion that accompanies prior art devices employing photomultiplier tubes. A method is also provided for carrying out radiation area detection using the device of the invention.

Carter, Daniel C.↗

Bright and durable scintillation from colloidal quantum shells

Abstract Efficient, fast, and robust scintillators for ionizing radiation detection are crucial in various fields, including medical diagnostics, defense, and particle physics. However, traditional scintillator technologies face challenges in simultaneously achieving optimal performance and high-speed operation. Herein we introduce colloidal quantum shell heterostructures as X-ray and electron scintillators, combining efficiency, speed, and durability. Quantum shells exhibit light yields up to 70,000 photons MeV −1 at room temperature, enabled by their high multiexciton radiative efficiency thanks to long Auger-Meitner lifetimes (>10 ns). Radioluminescence is fast, with lifetimes of 2.5 ns and sub-100 ps rise times. Additionally, quantum shells do not exhibit afterglow and maintain stable scintillation even under high X-ray doses (>10 9 Gy). Furthermore, we showcase quantum shells for X-ray imaging achieving a spatial resolution as high as 28 line pairs per millimeter. Overall, efficient, fast, and durable scintillation make quantum shells appealing in applications ranging from ultrafast radiation detection to high-resolution imaging.

47 OTHER INSTRUMENTATION↗

MRDIS Case Study

The Mobile Radiation Detection and Identification System (MRDIS) is a large mobile scanner that inspects containers in transit from cargo ships for radiological materials. The MRDIS platform operates as a two-part system with one MRDIS using a plastic Polyvinyl Toleune (synthetic polymer) for primary detection and another MRDIS that uses spectroscopic detectors for secondary isotopic identification. MRDIS can operate either independently or as part of a team, depending on the needs of the port. MRDIS is controlled by a human operator, who searches the computer monitor for any traces of radiological materials when the containers pass through the center of the system. Each MRDIS can also feed data into a central system or collect data on its own for additional material analysis. The system integrates radiation detection, radioisotope identification, an optical character recognition system, occupancy/speed sensors, wireless communications, and data processing capabilities to discern what specific radiological materials are of particular interest. In addition, Sandia engineers created a detailed set of requirements for subsequent models, allowing for faster implementation of additional detection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient Prompt Scintillation and Fast Neutron-Gamma Ray Discrimination Using Amorphous Blends of Difluorenylsilane Organic Glass and in-situ Polymerized Vinyltoluene

High performance radiation detection materials are an integral part of national security, medical imaging, and nuclear physics applications. Those that offer compositional and manufacturing versatility are of particular interest. In this work, we report a new family of radiological particle-discriminating scintillators containing bis(9,9-dimethyl-9H-fluoren-2- yl)diphenylsilane (compound “P2”) and in-situ polymerized vinyltoluene (PVT) that is phase stable and mechanically robust at any blend ratio. The gamma-ray light yield increases nearly linearly across the composition range, to ~16,400 photons/MeV at 75 % wt. P2. These materials are also capable of γ/n pulse shape discrimination (PSD) and between 20-50 % P2 loading are competitive with the PSD quality of commercially-available plastic scintillators. The 137 Cs scintillation rise and decay times are sensitive to P2 loading and approach the values for “pure” P2. Additionally, the radiation detection performance of P2-PVT blends can be made stable in 60°C air for at least 1.5 months with the application of a thin film of poly(vinylalcohol) to the scintillator surfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation-Generating Device Safety Self-Study [Slides]

Self-study slides are included for the following modules: RGD Safety Course Presentation, Radiation Detection, Biological Effects, RGDs, Radiation Protection Principles, Production of X-Rays, Protective Measures, and Responsibilities for X-Ray Safety.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Advancements in medicine from aerospace research

A program designed to find second applications for space technology in the medical field is described. Illustrative examples and clinical test results are included for prosthetic urethral devices, ear oximeter for monitoring leukemia patients, devices for measuring low level CO effects on automobile drivers, radiation dosimeter probe for detecting radiation levels in cancerous areas, and electromyographic muscle trainer.

Wooten, F. T.↗

The challenge of detecting gravitational radiation is creating a new chapter in quantum electronics: Quantum nondemolition measurements

Future gravitational wave antennas will be approximately 100 kilogram cylinders, whose end-to-end vibrations must be measured so accurately (10 to the -19th power centimeters) that they behave quantum mechanically. Moreover, the vibration amplitude must be measured over and over again without perturbing it (quantum nondemolition measurement). This contrasts with quantum chemistry, quantum optics, or atomic, nuclear, and elementary particle physics where measurements are usually made on an ensemble of identical objects, and care is not given to whether any single object is perturbed or destroyed by the measurement. Electronic techniques required for quantum nondemolition measurements are described as well as the theory underlying them.

Braginsky, V. B.↗

Earth's magnetic field as a radiator to detect cosmic ray electrons of energy greater than 10 to the 12th power eV

The synchrotron emission by electrons of energy greater than a few TeV in Earth's magnetic field was examined. An omnidirectional detector, it is shown, can be satisfactorily used to estimate the energy. The collecting power of the detector, it is also shown, is a sensitive function of the area of the detector, the energy of electron, and the number of photons required to identify an electron. The event rate expected was calculated using an ideal balloon-borne detector.

Stephens, S. A.↗

Earth's magnetic field as a radiator to detect cosmic ray electrons of energy greater than 10 to the 12th eV

Synchrotron emission by a high-energy electron in the geomagnetic field and its dependence upon different arrival directions over Palestine, Texas, where major balloon-borne experiments are being conducted, is studied. The dependence of detector response on the arrival direction of electron, the different criteria which are adopted to identify an electron event, the area of the detector, and the energy of the electron are discussed. An omnidirectional circular detector is used to examine whether it is possible to determine the energy of an electron without knowing its arrival direction. The collecting power of a detector is estimated as a function of the energy of electrons for different detector areas with different selection criteria, and this information is used to calculate the event rates expected by folding in the energy spectrum of cosmic ray electrons to show the viability of detecting cosmic ray electrons at energies greater than a few TeV.

Balasubrahmanyan, V. K.↗