Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RPC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SU-E-CAMPUS-T-03: Development and Implementation of An Anthropomorphic Pediatric Spine Phantom for the Assessment of Craniospinal Irradiation Procedures in Proton Therapy

Purpose: To design an anthropomorphic pediatric spine phantom for use in the evaluation of proton therapy facilities for clinical trial participation by the Imaging and Radiation Oncology Core (IROC) Houston QA Center (formerly RPC). Methods: This phantom was designed to perform an end-to-end audit of the proton spine treatment process, including simulation, dose calculation by the treatment planning system (TPS), and proton treatment delivery. The design incorporated materials simulating the thoracic spinal column of a pediatric patient, along with two thermoluminescent dosimeter (TLD)-100 capsules and radiochromic film embedded in the phantom for dose evaluation. Fourteen potential materials were tested to determine relative proton stopping power (RSP) and Hounsfield unit (HU) values. Each material was CT scanned at 120kVp, and the RSP was obtained from depth ionization scans using the Zebra multilayer ion chamber (MLIC) at two energies: 160 MeV and 250 MeV. To determine tissue equivalency, the measured RSP for each material was compared to the RSP calculated by the Eclipse TPS for a given HU. Results: The materials selected as bone, tissue, and cartilage substitutes were Techron HPV Bearing Grade (Boedeker Plastics, Inc.), solid water, and blue water, respectively. The RSP values did not differ by more than 1.8% between the two energies. The measured RSP for each selected material agreed with the RSP calculated by the Eclipse TPS within 1.2%. Conclusion: An anthropomorphic pediatric proton spine phantom was designed to evaluate proton therapy delivery. The inclusion of multiple tissue substitutes increases heterogeneity and the level of difficulty for institutions to successfully treat the phantom. The following attributes will be evaluated: absolute dose agreement, distal range, field width, junction match and right/left dose profile alignment. The phantom will be tested at several institutions using a 5% dose agreement criterion, and a 5%/3mm gamma analysis criterion for the film planes. Work supported by grants CA10953, CA059267, and CA81647 (NCI, DHHS)

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-BRE-06: Evaluation of Patient CT Dose Reconstruction From 3D Diode Array Measurements Using Anthropomorphic Phantoms

Purpose: To compare 3D reconstructed dose of IMRT plans from 3D diode array measurements with measurements in anthropomorphic phantoms. Methods: Six IMRT plans were created for the IROC Houston (RPC) head and neck (H and N) and lung phantoms following IROC Houston planning protocols. The plans included flattened and unflattened beam energies ranging from 6 MV to 15 MV and both static and dynamic MLC tecH and Niques. Each plan was delivered three times to the respective anthropomorphic phantom, each of which contained thermoluminescent dosimeters (TLDs) and radiochromic films (RCFs). The plans were also delivered to a Delta4 diode array (Scandidos, Uppsala, Sweden). Irradiations were done using a TrueBeam STx (Varian Medical Systems, Palo Alto, CA). The dose in the patient was calculated by the Delta4 software, which used the diode measurements to estimate incident energy fluence and a kernel-based pencil beam algorithm to calculate dose. The 3D dose results were compared with the TLD and RCF measurements. Results: In the lung, the average difference between TLDs and Delta4 calculations was 5% (range 2%–7%). For the H and N, the average differences were 2.4% (range 0%–4.5%) and 1.1% (range 0%–2%) for the high- and low-dose targets, respectively, and 12% (range 10%-13%) for the organ-at-risk simulating the spinal cord. For the RCF and criteria of 7%/4mm, 5%/3mm, and 3%/3mm, the average gamma-index pass rates were 95.4%, 85.7%, and 76.1%, respectively for the H and N and 76.2%, 57.8%, and 49.5% for the lung. The pass-rate in the lung decreased with increasing beam energy, as expected for a pencil beam algorithm. Conclusion: The H and N phantom dose reconstruction met the IROC Houston acceptance criteria for clinical trials; however, the lung phantom dose did not, most likely due to the inaccuracy of the pencil beam algorithm in the presence of low-density inhomogeneities. Work supported by PHS grant CA10953 and CA81647 (NCI, DHHS)

60 APPLIED LIFE SCIENCES↗

MO-E-18C-01: Open Access Web-Based Peer-To-Peer Training and Education in Radiotherapy

Purpose: Current training and education delivery models have limitations which result in gaps in clinical proficiency with equipment, procedures, and techniques. Educational and training opportunities offered by vendors and professional societies are by their nature not available at point of need or for the life of clinical systems. The objective of this work is to leverage modern communications technology to provide peer-to-peer training and education for radiotherapy professionals, in the clinic and on demand, as they undertake their clinical duties. Methods: We have developed a free of charge web site ( https://i.treatsafely.org ) using the Google App Engine and datastore (NDB, GQL), Python with AJAX-RPC, and Javascript. The site is a radiotherapy-specific hosting service to which user-created videos illustrating clinical or physics processes and other relevant educational material can be uploaded. Efficient navigation to the material of interest is provided through several RT specific search tools and videos can be scored by users, thus providing comprehensive peer review of the site content. The site also supports multilingual narration\translation of videos, a quiz function for competence assessment and a library function allowing groups or institutions to define their standard operating procedures based on the video content. Results: The website went live in August 2013 and currently has over 680 registered users from 55 countries; 27.2% from the United States, 9.8% from India, 8.3% from the United Kingdom, 7.3% from Brazil, and 47.5% from other countries. The users include physicists (57.4%), Oncologists (12.5%), therapists (8.2%) and dosimetrists (4.8%). There are 75 videos to date including English, Portuguese, Mandarin, and Thai. Conclusion: Based on the initial acceptance of the site, we conclude that this open access web-based peer-to-peer tool is fulfilling an important need in radiotherapy training and education. Site functionality should expand in the future to include document sharing and continuing education credits.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-G-BRE-02: A Survey of IMRT QA Practices for More Than 800 Institutions

Purpose: A wide range of techniques and measurement devices are employed for IMRT QA, causing a large variation of accepted action limits and potential follow up for failing plans. Such procedures are not well established or accepted in the medical physics community. To achieve the goal of proving insight into current IMRT QA practices, we created an electronic IMRT QA survey. The survey was open to a variety of the most common QA devices and assessed the type of comparison to measurement, action limits, delivery methods, and clinical action for failing QA plans. Methods: We conducted an online survey through the Radiological Physics Center's (RPC) annual survey with the goal of ascertaining elements of routine patient-specific IMRT QA. A total of 874 institutions responded to the survey. The questions ranged from asking for action limits, dosimeter type(s) used, delivery techniques, and actions taken when a plan fails IMRT QA. Results: The most common (52%) planar gamma criteria was 3%/3 mm with a 95% of pixels passing criteria. The most common QA device were diode arrays (48%). The most common first response to a plan failing QA was to re-measure at the same point the point dose (89%), second was to re-measure at a new point (13%), and third was to analyze the plan in relative instead of absolute mode (10%) (Does not add to 100% as not all institutions placed a response for each QA follow-up option). Some institutions, however, claimed that they had never observed a plan failure. Conclusion: The survey provided insights into the way the community currently performs IMRT QA. This information will help in the push to standardize action limits among dosimeters.

60 APPLIED LIFE SCIENCES↗

TU-C-9A-01: IROC Organization and Clinical Trial Credentialing

As a response to recommendations from a report from the Institute of Medicine, NCI is reorganizing it clinical trial groups into a National Clinical Trial Network (NCTN) that consists of four adult groups (Alliance, ECOGACRIN, NRG, and SWOG) and one children’s group (COG). NRG will house CIRO, a center to promote innovative radiation therapy research and intergroup collaboration in radiation. The quality assurance groups that support clinical trials have also been restructured. ITC, OSU Imaging corelab, Philadelphia Imaging core-lab, QARC, RPC, and RTOGQA have joined together to create the Imaging and Radiation Oncology Core (IROC) Group. IROC’s mission is to provide integrated radiation oncology and diagnostic imaging quality control programs in support of the NCI’s NCTN thereby assuring high quality data for clinical trials designed to improve the clinical outcomes for cancer patients worldwide. This will be accomplished through five core services: site qualification, trial design support, credentialing, data management, case review.These changes are important for physicist participating in NCI clinical trials to understand. We will describe in detail the IROC’s activities and five core services so that as a user, the medical physicist can learn how to efficiently utilize this group. We will describe common pitfalls encountered in credentialing for current protocols and present methods to avoid them. These may include the which benchmarks are required for NSABP B-51/RTOG 1304 and how to plan them as well as tips for phantom planning. We will explain how to submit patient and phantom cases in the TRIAD system used by IROC. Learning Objectives: To understand the basic organization of IROC, its mission and five core services To learn how to use TRIAD for patient and phantom data submission To learn how to avoid common pitfalls in credentialing for current trials.

60 APPLIED LIFE SCIENCES↗

SU-E-J-208: Feasibility Study On Using Small Plastic Phantoms for Auditing Radiation Output of MR-Linac Systems

Purpose: To study feasibility of using small plastic phantoms designed for conventional linac output auditing to measure the output of MR-Linac systems. Methods: For simulations, the CT scan of an IROC(formerly RPC) acrylic block phantom designed for 8 MV beams was imported in a research version of the treatment planning system (Monaco). Dose delivered to three TLDs in the block was calculated with a Monte Carlo algorithm and a beam model based on an MR-linac prototype with and without a magnetic field (B=1.5T). In a large mathematical water phantom, the same beam was used to calculate dose in full scatter conditions. The block factor (F) was calculated as the ratio of the average dose to the block TLDs to the dose at the reference point in the mathematical phantom. For experimental measurement, four IROC blocks were irradiated with the MR-linac prototype, and data were analyzed by IROC. Results: The F factor without a B field was 1.053. When a B field was applied, it changed the dose distribution in the block, especially on the edges. With a B field parallel to the long axes of the TLD, F was 1.038. However, with a perpendicular B field, F factor increased slightly to 1.075. In the IROC report, the output determined with two blocks parallel to the B field was 2.3% higher than the output by the two blocks perpendicular to the B field. The average of all four blocks was within 2% of machine output measured with an ion chamber. Conclusion: It may be feasible to expand the utility of the acrylic block phantoms for radiation output auditing from conventional linacs to MR-linacs. However, the scatter correction factor can change due to the B field and its orientation to the block. More symmetric phantom designs may be less prone to mistakes. We acknowledge research support from Elekta.

60 APPLIED LIFE SCIENCES↗

TU-G-BRD-06: The Imaging and Radiation Oncology Core Houston (IROC Houston) QA Center International Activities Outside North America

Purpose: To describe the extent of IROC Houston’s (formerly the RPC) QA activities and audit results for radiotherapy institutions outside of North America (NA). Methods: The IROC Houston’s QA program components were designed to audit the radiation dose calculation chain from the NIST traceable reference beam calibration, to inclusion of dosimetry parameters used to calculate tumor doses, to the delivery of the radiation dose. The QA program provided to international institutions includes: 1) remote TLD/OSLD audit of machine output, 2) credentialing for advanced technologies, and 3) review of patient treatment records. IROC Houston uses the same standards and acceptance criteria for all of its audits whether for North American or international sites. Results: IROC Houston’s QA program has reached out to radiotherapy sites in 43 different countries since 2013 through their participation in clinical trials. In the past two years, 2,778 international megavoltage beam outputs were audited with OSLD/TLD. While the average IROC/Inst ratio is near unity for all sites monitored, there are international regions whose results are significantly different from the NA region. In the past 2 years, 477 and 87 IMRT H&N phantoms were irradiated at NA and international sites, respectively. Regardless of the OSLD beam audit results, the overall pass rate (87 percent) for all international sites (no region separation) is equal to the NA sites. Of the 182 international patient charts reviewed, 10.7 percent of the dose calculation points did not meet our acceptance criterion as compared to 13.6 percent for NA sites. The lower pass rate for NA sites results from a much larger brachytherapy component which has been shown to be more error prone. Conclusion: IROC Houston has expanded its QA services worldwide and continues a long history of improving radiotherapy dose delivery in many countries. Funding received for QA audit services from the Korean GOG, DAHANCA, EORTC, ICON and CMIC Group.

60 APPLIED LIFE SCIENCES↗

SU-F-T-632: On the Use of Intensity Modulated Arc Therapy for Thoracic Vertebral Metastases SBRT Treatment

Purpose: To retrospectively evaluate quality, efficiency and delivery accuracy of intensity modulated arc therapy (IMAT) plans for thoracic-vertebral metastases using stereotactic body radiotherapy (SBRT). Methods: After obtaining approval of RPC-benchmark plan, seven previously treated thoracic-vertebral metastases patients with non-coplanar hybrid arcs(NC-HA)using 1–2 3D-dynamic conformal partial-arcs plus 7–9 IMRT-beams were re-optimized with IMAT using 3 full co-planar arcs. Tumors were located between T2–T7. T1/T2-weighted MRI images were co-registered with planning-CT. PTVs were between 24.3–240.1cc(median=48.1cc). Prescription was 30Gy in 5 fractions with 6-MV beams at Novalis-TX consisting of HD-MLC.Plans were compared for target coverage:conformality index(CI),homogeneity index(HI),PTVD90. Organs-at-risks(OARs)was evaluated for spinal cord(Dmax, D0.35cc, and D1.2cc), esophagus(Dmax and D5cc),heart(Dmax, D15cc)and lung(V5 and V10). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance(QA) plan. Beam-on time was recorded and a gamma index was used to compare agreement between planned and measured doses. Results: SBRT IMAT plans resulted in superior CI(1.02 vs. 1.36, p=0.05) and HI (0.14 vs. 0.27, p=0.01). PTVD90 was improved but statistically insignificant (31.0 vs. 30.4Gy, p=0.38). IMAT resulted in statistically significant improvements in OARs sparing: esophagus max(22.5 vs. 27.0Gy, p=0.03), esophagus 5cc (17.6 vs. 21.5Gy, p=0.02) and heart max(13.1 vs. 15.8Gy, p=0.03). Spinal cord,lung V5 and V10 were lower but statistically insignificant. Average total MU and beam-on time were 2598±354 vs. 3542±495 and 4.7±0.6 min vs. 7.1±1.0min for IMAT vs. NC-HA (without accounting for couch kicks time for NC-HA). IMAT plans demonstrated an accurate dose delivery of 95.5±1.0% for clinical gamma passing-rate of 2%/2mm criteria on MapCHECK, that was comparable to NC-HA plans. Conclusion: IMAT plans provided highly conformal and homogeneous dose distributions to target and reduced OARs doses compared to NC-HA. Total MU was reduced by a factor of 1.4 and subsequently decreased treatment times significantly - potentially minimizing intra-fraction motion error and owing to patient comfort. SBRT using IMAT planning for single fraction thoracic-vertebrae metastases will be investigated.

60 APPLIED LIFE SCIENCES↗

The UPC++ PGAS library for exascale computing. Extended Abstract

We describe UPC++ V1.0, a C++11 library that supports APGAS programming. UPC++ targets distributed data structures where communication is irregular or fine-grained. The key abstractions are global pointers, asynchronous programming via RPC, and futures. Global pointers incorporate ownership information useful in optimizing for locality. Futures capture data readiness state, are useful for scheduling and also enable the programmer to chain operations to execute asynchronously as high-latency dependencies become satisfied, via continuations. The interfaces for moving non-contiguous data and handling memories with different optimal access methods are composable and closely resemble those used in modern C++. Communication in UPC++ runs at close to hardware speeds by utilizing the low-overhead GASNet-EX communication library.

97 MATHEMATICS AND COMPUTING↗

DoCeph: DPU-Offloaded Messaging in Ceph for Reduced Host CPU Utilization

Ceph is a widely used distributed object store, but its messenger layer imposes substantial CPU overhead on the host. To address this limitation, we propose DoCeph, a DPU-offloaded storage architecture for Ceph that disaggregates the system by offloading the communication-intensive messaging component to the DPU while retaining the storage backend on the host. The DPU efficiently manages communication, using lightweight RPC for metadata operations and DMA for data transfer. Moreover, DoCeph introduces a pipelining technique that overlaps data transmission with buffer preparation, mitigating hardware-imposed transfer size limitations. We implemented DoCeph on a Ceph cluster with NVIDIA BlueField-3 DPUs. Evaluation results indicate that DoCeph cuts host CPU usage by up to 92% while sustaining stable throughput and providing larger performance benefits for object writes over 1 MB.

Park, Kuri [Sogang University]↗

UPC++ V1.0

UPC++ is a C++11 library providing classes and functions that support Partitioned Global Address Space (PGAS) programming. We are revising the library under the auspices of the DOE's Exascale Computing Project, to meet the needs of applications requiring PGAS support. UPC++ is intended for implementing elaborate distributed data structures where communication is irregular or fine-grained. The UPC++ interfaces for moving non-contiguous data and handling memories with different optimal access methods are composable and similar to those used in conventional C++. The UPC++ programmer can expect communication to run at close to hardware speeds. The key facilities in UPC++ are global pointers, that enable the programmer to express ownership information for improving locality, one-sided communication, both put/get and RPC, futures and continuations. Futures capture data readiness state, which is useful in making scheduling decisions, and continuations provide for completion handling via callbacks. Together, these enable the programmer to chain together a DAG of operations to execute asynchronously as high-latency dependencies become satisfied.

ECP↗

SSG (Scalable Service Groups)

SSG is a group membership microservice based on the Mercury RPC system. It provides mechanisms for bootstrapping sets of Mercury processes into logical groups and for managing the membership of these process groups over time. At a high-level, each group collectively maintains a group view, which is just a mapping from group member identifiers to Mercury address information. The initial group membership view is specified completely when the group is bootstrapped (created).

Carns, Phil↗

PvaPy: Python API for EPICS PV Access

As the number of sites deploying and adopting EPICS Version 4 grows, so does the need to support PV Access from multiple languages. Especially important are the widely used scripting languages that tend to reduce both software development time and the learning curve for new users. In this paper we describe PvaPy, a Python API for the EPICS PV Access protocol and its accompanying structured data API. Rather than implementing the protocol itself in Python, PvaPy wraps the existing EPICS Version 4 C++ libraries using the Boost.Python framework. This approach allows us to benefit from the existing code base and functionality, and to significantly reduce the Python API development effort. PvaPy objects are based on Python dictionaries and provide users with the ability to access even the most complex of PV Data structures in a relatively straightforward way. Its interfaces are easy to use, and include support for advanced EPICS Version 4 features such as implementation of client and server Remote Procedure Calls (RPC).

Veseli, S.↗

A Compute Capable SSD Architecture for Next-Generation Non-volatile Memories

Existing storage technologies (e.g., disks and ash) are failing to cope with the processor and main memory speed and are limiting the overall perfor- mance of many large scale I/O or data-intensive applications. Emerging fast byte-addressable non-volatile memory (NVM) technologies, such as phase-change memory (PCM), spin-transfer torque memory (STTM) and memristor are very promising and are approaching DRAM-like performance with lower power con- sumption and higher density as process technology scales. These new memories are narrowing down the performance gap between the storage and the main mem- ory and are putting forward challenging problems on existing SSD architecture, I/O interface (e.g, SATA, PCIe) and software. This dissertation addresses those challenges and presents a novel SSD architecture called XSSD. XSSD o oads com- putation in storage to exploit fast NVMs and reduce the redundant data tra c across the I/O bus. XSSD o ers a exible RPC-based programming framework that developers can use for application development on SSD without dealing with the complication of the underlying architecture and communication management. We have built a prototype of XSSD on the BEE3 FPGA prototyping system. We implement various data-intensive applications and achieve speedup and energy ef- ciency of 1.5-8.9 and 1.7-10.27 respectively. This dissertation also compares XSSD with previous work on intelligent storage and intelligent memory. The existing ecosystem and these new enabling technologies make this system more viable than earlier ones.

97 MATHEMATICS AND COMPUTING↗

Development of Large Area Gas Electron Multiplier Detector and Its Application to a Digital Hadron Calorimeter for Future Collider Experiments

The UTA High Energy Physics Group conducted generic detector development based on large area, very thin and high sensitivity gas detector using gas electron multiplier (GEM) technology. This is in preparation for a use as a sensitive medium for sampling calorimeters in future collider experiments at the Energy Frontier as well as part of the tracking detector in Intensity Frontier experiments. We also have been monitoring the long term behavior of one of the prototype detectors (30cmx30cm) read out by the SLAC-developed 13-bit KPiX analog chip over three years and have made presentations of results at various APS meetings. While the important next step was the development of large area (1m x 1m) GEM planes, we also have looked into opportunities of applying this technology to precision tracking detectors to significantly improve the performance of the Range Stack detector for CP violation experiments and to provide an amplification layer for the liquid Argon Time Projection Chamber in the LBNE experiment. We have jointly developed 33cmx100cm large GEM foils with the CERN gas detector development group to construct 33cm x100cm unit chambers. Three of these unit chambers will be put together to form a 1m x 1m detector plane. Following characterization of one 33cmx100cm unit chamber prototype, a total of five 1m x 1m planes will be constructed and inserted into an existing 1m3 RPC DHCAL stack to test the performance of the new GEM DHCAL in particle beams. The large area GEM detector we planned to develop in this proposal not only gives an important option to DHCAL for future collider experiments but also the potential to expand its use to Intensity Frontier and Cosmic Frontier experiments as high efficiency, high amplification anode planes for liquid Argon time projection chambers. Finally, thanks to its sensitivity to X-rays and other neutral radiations and its light-weight characteristics, the large area GEM has a great potential for the use in medical imaging and homeland security, as well as satellite based astronomy experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

UPC++ Specification v1.0, Draft 4

UPC++ is a C++11 library providing classes and functions that support Asynchronous Partitioned Global Address Space (APGAS) programming. We are revising the library under the auspices of the DOE’s Exascale Computing Project, to meet the needs of applications requiring PGAS support. UPC++ is intended for implementing elaborate distributed data structures where communication is irregular or fine-grained. The UPC++ interfaces for moving non-contiguous data and handling memories with different optimal access methods are composable and similar to those used in conventional C++. The UPC++ programmer can expect communication to run at close to hardware speeds. The key facilities in UPC++ are global pointers, that enable the programmer to express ownership information for improving locality, one-sided communication, both put/get and RPC, futures and continuations. Futures capture data readiness state, which is useful in making scheduling decisions, and continuations provide for completion handling via callbacks. Together, these enable the programmer to chain together a DAG of operations to execute asynchronously as high-latency dependencies become satisfied.

97 MATHEMATICS AND COMPUTING↗

UPC++ Specification v1.0, Draft 6

UPC++ is a C++11 library providing classes and functions that support Partitioned Global Address Space (PGAS) programming. We are revising the library under the auspices of the DOE’s Exascale Computing Project, to meet the needs of applications requiring PGAS support. UPC++ is intended for implementing elaborate distributed data structures where communication is irregular or fine-grained. The UPC++ interfaces for moving non-contiguous data and handling memories with different optimal access methods are composable and similar to those used in conventional C++. The UPC++ programmer can expect communication to run at close to hardware speeds. The key facilities in UPC++ are global pointers, that enable the programmer to express ownership information for improving locality, one-sided communication, both put/get and RPC, futures and continuations. Futures capture data readiness state, which is useful in making scheduling decisions, and continuations provide for completion handling via callbacks. Together, these enable the programmer to chain together a DAG of operations to execute asynchronously as high-latency dependencies become satisfied.

97 MATHEMATICS AND COMPUTING↗

UPC++ Specification v1.0, Draft 10

UPC++ is a C++11 library providing classes and functions that support Partitioned Global Address Space (PGAS) programming. We are revising the library under the auspices of the DOE’s Exascale Computing Project, to meet the needs of applications requiring PGAS support. UPC++ is intended for implementing elaborate distributed data structures where communication is irregular or fine-grained. The UPC++ interfaces for moving non-contiguous data and handling memories with different optimal access methods are composable and similar to those used in conventional C++. The UPC++ programmer can expect communication to run at close to hardware speeds. The key facilities in UPC++ are global pointers, that enable the programmer to express ownership information for improving locality, one-sided communication, both put/get and RPC, futures and continuations. Futures capture data readiness state, which is useful in making scheduling decisions, and continuations provide for completion handling via callbacks. Together, these enable the programmer to chain together a DAG of operations to execute asynchronously as high-latency dependencies become satisfied.

97 MATHEMATICS AND COMPUTING↗