Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROOFS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

De-pollution efficacy of photocatalytic roofing granules

Photocatalytic building surfaces can harness sunlight to reduce urban air pollution. The NO x abatement capacity of TiO 2 -coated granules used in roofing products was evaluated for commercial product development. A laboratory test chamber and ancillary setup were built following conditions prescribed by ISO Standard 22197-1. It was validated by exposing reference P25-coated aluminum plates to a 3 L min -1 air flow enriched in 1 ppm NO under UVA irradiation (360 nm, 11.5 W m -2 ). We characterized prototype granule-surfaced asphalt shingles and loose granules prepared with different TiO 2 loadings and post-treatment formulations. Tests performed at surface temperatures of 25 and 60 °C showed that NO x abatement was more effective at the higher temperature. Preliminary tests explored the use of 1 ppm NO 2 and of 1 ppm and 0.3 ppm NO/NO 2 mixtures. Specimens were aged in a laboratory accelerated weathering apparatus, and by exposure to the outdoor environment over periods that included dry and rainy seasons. Laboratory aging led to higher NO removal and NO 2 formation rates, and the same catalyst activation was observed after field exposure with frequent precipitation. However, exposure during the dry season reduced the performance. This inactivation was mitigated by cleaning the surface of field-exposed specimens. Doubling the TiO 2 loading led to a 50–150% increase in NO removal and NO x deposition rates. Finally, application of different post-treatment coatings decreased NO removal rates (21–35%) and NO x deposition rates (26–74%) with respect to untreated granules. The mass balance of nitrogenated species was assessed by extracting granules after UV exposure in a 1 ppm NO-enriched atmosphere.

54 ENVIRONMENTAL SCIENCES↗

Simulation of effects of direction and air flow speed on temperature distribution in the room covered by various roof materials

The objective of this research is to get a comparison of the distribution of the room temperature by using three materials, namely plastic-rubber composite, clay, and asbestos. The simulation used Ansys Fluent to get the temperature distribution. There were two conditions in this simulations, first the air passing beside the room and second the air passing in front of the room. Each condition will be varied with the air speed of 1 m/s, 2 m/s, 3 m/s, 4 m/s, 5 m/s for each material used. There are three heat transfers in this simulation, namely radiation, convection, and conduction. Based on the ANSI/ ASHRAE Standard 55-2004, the results of the simulation showed that the best temperature distribution was the roof of plastic-rubber composites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Attic or Roof? An Evaluation of Two Advanced Weatherization Packages

This project examines implementation of advanced retrofit measures in the context of a large-scale weatherization program and the archetypal Chicago brick bungalow. One strategy applies best practice air sealing methods and a standard insulation method to the attic floor. The other strategy creates an unvented roof assembly using materials and methods typically available to weatherizationcontractors. Through implementations of the retrofit strategies in a total of eight (8) test homes, the research found that the two different strategies achieve similar reductions in air leakage measurement (55%) and predicted energy performance (18%) relative to the pre-retrofit conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Efficiency Solar Integrated Roof Membrane Product

This project was designed to address the Solar Energy Technology Program objective, to develop new methods to integrate photovoltaic (PV) cells or modules within a building-integrated photovoltaic (BIPV) application that will result in lower installed cost as well as higher efficiencies of the encapsulated/embedded PV module. The technology assessment and development focused on the evaluation and identification of manufacturing technologies and equipment capable of producing such low-cost, high-efficiency, flexible BIPV solar cells on single-ply roofing membranes.

14 SOLAR ENERGY↗

Attic or Roof? An Evaluation of Two Advanced Weatherization Packages

This project examines implementation of advanced retrofit measures in the context of a large-scale weatherization program and the archetypal Chicago brick bungalow. One strategy applies best practice air sealing methods and a standard insulation method to the attic floor. The other strategy creates an unvented roof assembly using materials and methods typically available to weatherization contractors. Through implementations of the retrofit strategies in a total of eight (8) test homes, the research found that the two different strategies achieve similar reductions in air leakage measurement (55%) and predicted energy performance (18%) relative to the pre-retrofit conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Analysis of Roof-Only Air Sealing and Insulation Strategies on 1 ½-Story Homes in Cold Climates

The External Thermal and Moisture Management System (ETMMS), typically seen in deep energy retrofits, is a valuable approach for the roof-only portions of existing homes, particularly the 1 ½-story home. It is effective in reducing energy loss through the building envelope, improving building durability, reducing ice dams, and providing opportunities to improve occupant comfort and health.

1 ½-Story House↗

Thermal Performance Evaluation of Innovative Metal Building Roof Assemblies

In order to meet the coming energy codes, multiple layers of various insulation types will be required. The demand for greater efficiency has pushed insulation levels beyond the cavity depth. These experiments show the potential for improving metal building roof thermal performance. Additional work is currently being done by several stakeholders, so the data is expanding. These experiments are for research and development purposes, and may not be viable for immediate use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

White Roofs

Secretary Steven Chu discusses the benefits of switching to white roofs and light colored pavements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technology Solutions Case Study: Cost Analysis of Roof-Only Air Sealing and Insulation Strategies on 1-1/2 Story Homes in Cold Climates, Minneapolis, MN

This case study describes the External Thermal and Moisture Management System developed by the NorthernSTAR Building America Partnership. This system is typically used in deep energy retrofits and is a valuable approach for the roof-only portions of existing homes, particularly the 1 1/2-story home. It is effective in reducing energy loss through the building envelope, improving building durability, reducing ice dams, and providing opportunities to improve occupant comfort and health.

1 1/2-STORY HOUSE↗

Roof bolting improvements

Suppliers partner with mine operators to offer safer, more productive tools for roof bolting. 4 figs.

01 COAL, LIGNITE, AND PEAT↗

Numerical evaluation of convex-roof entanglement measures with applications to spin rings

We present two ready-to-use numerical algorithms to evaluate convex-roof extensions of arbitrary pure-state entanglement monotones. Their implementation leaves the user merely with the task of calculating derivatives of the respective pure-state measure. We provide numerical tests of the algorithms and demonstrate their good convergence properties. We further employ them in order to investigate the entanglement in particular few-spins systems at finite temperature. Namely, we consider ferromagnetic Heisenberg exchange-coupled spin-(1/2) rings subject to an inhomogeneous in-plane field geometry obeying full rotational symmetry around the axis perpendicular to the ring through its center. We demonstrate that highly entangled states can be obtained in these systems at sufficiently low temperatures and by tuning the strength of a magnetic field configuration to an optimal value which is identified numerically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calculation of the convex roof for an open entangled harmonic oscillator system

We explicitly calculate the time dependence of entanglement via the convex roof extension for a system of noninteracting harmonic oscillators. These oscillators interact only indirectly with each other by way of a zero-temperature bath. The initial state of the oscillators is taken to be that of an entangled Schroedinger-cat state. This type of initial condition leads to superexponential decay of the entanglement when the initial state has the same symmetry as the interaction Hamiltonian.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates

This project evaluates the cooling energy savings and cost effectiveness of radiation control retrofit strategies for residential attics in U.S. cooling-dominated climates. Usually, in residential applications, radiation control retrofit strategies are applied below the roof deck or on top of the attic floor insulation. They offer an alternative option to the addition of conventional bulk insulation such as fiberglass or cellulose insulation. Radiation control is a potentially low-cost energy efficiency retrofit strategy that does not require significant changes to existing homes. In this project, two groups of low-cost radiation control strategies were evaluated for southern U.S. applications. One uses a radiant barrier composed of two aluminum foils combined with an enclosed reflective air space and the second uses spray-applied interior radiation control coatings (IRCC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates

This project evaluates the cooling energy savings and cost effectiveness of radiation control retrofit strategies for residential attics in U.S. cooling-dominated climates. Usually, in residential applications, radiation control retrofit strategies are applied below the roof deck or on top of the attic floor insulation. They offer an alternative option to the addition of conventional bulkinsulation such as fiberglass or cellulose insulation. Radiation control is a potentially low-cost energy efficiency retrofit strategy that does not require significant changes to existing homes. In this project, two groups of low-cost radiation control strategies were evaluated for southern U.S. applications. One uses a radiant barrier composed of two aluminum foils combined with an enclosedreflective air space and the second uses spray-applied interior radiation control coatings (IRCC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar Economies of Scope through the Intersection of Four Industries: PV Installation, Electrical, Construction, and Roofing

The U.S. solar photovoltaic (PV) installation industry largely grew from pre-existing industries that provide related services such as electrical contracting, construction, and roofing. In this report, we use a new data set based on data from the California Contractors State License Board (CSLB) to explore the ties between PV installation and these related-service industries. Based on a study period of 2010 to 2016, the CSLB data show that most PV installers hold some license other than the license designed specifically for PV installation, primarily electrical and construction licenses. Indeed, only about 9% of PV installers hold only the solar contractor license. The fact that most PV installers hold electrician and construction licenses illustrates the important ties between PV installation and these industries. The CSLB data, combined with residential PV price data, also show that installers with multiple non-solar licenses are associated with lower-priced systems. These findings suggest that installers with multiple skillsets may be able to reduce PV installation costs. Further, the data show that PV systems are lower-priced when installed during new construction, especially when new-construction systems are installed by licensed roofers.

14 SOLAR ENERGY↗