Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RODENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Sample preparation with sucrose cryoprotection dramatically alters Zn distribution in the rodent hippocampus, as revealed by elemental mapping

Transition metal ions (Fe, Mn, Cu, Zn) are essential for healthy brain function, but altered concentration, distribution, or chemical form of the metal ions has been implicated in numerous brain pathologies. Currently, it is not possible to image the cellular or sub-cellular distribution of metal ions in vivo and therefore, studying brain-metal homeostasis largely relies on ex vivo in situ elemental mapping. Sample preparation methods that accurately preserve the in vivo elemental distribution are essential if one wishes to translate the knowledge of elemental distributions measured ex vivo toward increased understanding of chemical and physiological pathways of brain disease. Furthermore, the choice of sample preparation is particularly important for metal ions that exist in a labile or mobile form, for which the in vivo distribution could be easily distorted by inappropriate sample preparation. One of the most widely studied brain structures, the hippocampus, contains a large pool of labile and mobile Zn. Herein, we describe how sucrose cryoprotection, the gold standard method of preparing tissues for immuno-histochemistry or immuno-fluorescence, which is also often used as a sample preparation method for elemental mapping studies, drastically alters hippocampal Zn distribution. Based on the results of this study, in combination with a comparison against the strong body of published literature that has used either rapid plunge freezing of brain tissue, or sucrose cryo-protection, we strongly urge investigators in the future to cease using sucrose cryoprotection as a method of sample preparation for elemental mapping, especially if Zn is an analyte of interest.

59 BASIC BIOLOGICAL SCIENCES↗

Interspecific synchrony of seed rain shapes rodent‐mediated indirect seed–seed interactions of sympatric tree species in a subtropical forest

Abstract Animal‐mediated indirect interactions play a significant role in maintaining the biodiversity of plant communities. Less known is whether interspecific synchrony of seed rain can alter the indirect interactions of sympatric tree species. We assessed the seed dispersal success by tracking the fates of 21 600 tagged seeds from six paired sympatric tree species in both monospecific and mixed plots across 4 successive years in a subtropical forest. We found that apparent mutualism was associated with the interspecific synchrony of seed rain both seasonally and yearly, whereas apparent competition or apparent predation was associated with interspecific asynchrony of seed rain either seasonally or yearly. We did not find consistent associations of indirect interactions with seed traits. Our study suggests that the interspecific synchrony of seed rain plays a key role in the formation of animal‐mediated indirect interactions, which, in turn, may alter the seasonal or yearly seed rain schedules of sympatric tree species.

Yang, Xifu↗

Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the best performance. At 50 mGy, the deviation from the reference obtained at 500 mGy were less than 4%. Also the LDPC algorithm provides reasonable results with deviation less than 10% at 50 mGy while PCF and MKB reconstruction show larger deviations even at higher dose levels. Conclusions: LDPC and HDTV increase CNR and allow for quantitative evaluations even at dose levels as low as 50 mGy. The left ventricular volumes exemplarily illustrate that cardiac parameters can be accurately estimated at lowest dose levels if sophisticated algorithms are used. This allows to reduce dose by a factor of 10 compared to today's gold standard and opens new options for longitudinal studies of the heart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-EF-BRA-11: Precision Partial-Tumor Irradiation of Dorsal Rodent Mammary Tumors

Purpose: To introduce a pre-clinical treatment technique on a micro-irradiator to treat specific volumes of dorsal mammary tumors in BALB/c mice while sparing lungs and spine. This technique facilitates pre-clinical investigation of tumor response to sub-optimal radiation treatments in which a portion of the tumor is unirradiated, known as a “marginal miss”. In-vitro data suggests that partial tumor radiations trigger a more aggressive phenotype in non-irradiated, regional tumor cells via bystander effects. As the lung tissue is spared, the impact of marginal miss on the development of pulmonary metastasis may be assessed. Methods: End to end test was performed on three BALB/c mice as proof of concept for larger studies. 1Gy was delivered on the micro-irradiator employing previously unexplored lateral parallel-opposed diamond and/or triangle-shaped beams. The margins of the treatment beam were defined using a combination of tumor palpation, barium fiducial markers, and real-time fluoroscopic images. The dose distribution was independently verified with kilovoltage beam Monte Carlo dose calculations with 7% statistical uncertainty and double exposure images. As a final step, the technique was used in a larger pre-clinical study (15Gy, 36 BALB/c mice) and lung metastasis in response to tumor irradiation of 100%, 50% and 0% was quantified. Results: For the Monte-Carlo dose calculations, the dose volume histograms established a maximum dose within the un-irradiated and radiated portions of the mammary tumor of 0.3Gy and 1.5Gy respectively, with a sharp gradient at the boundary. 100% of the lung volume received less than 0.5Gy. This technique proved suitable for a pre-clinical marginal miss study with 50% more lung metastases in partially-radiated mouse models compared to completely. Conclusion: We have developed a novel treatment technique for partial or full irradiation of dorsal mammary tumors incorporating lung sparing.The technique will be useful for exploring the phenomena of aggressive tumor phenotype that may arise from miss-irradiation.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP3-12: Retrospective Assessment of R2star Using Ultra-High Field MRI in a Rodent Model of Radiation Necrosis

Purpose: To establish a quantitative MRI method that would be capable of predicting radiation necrosis without using a contrast agent. Methods: Healthy male Fischer 344 rats were irradiated using an animal irradiator capable of delivering 2.3 Gy/min with a kVp of 225 V. A dose of 40 Gy was given to half the brain in a single session. Rats were scanned using a 9.4 T animal MRI before irradiation and every two weeks following radiation until either necrosis developed or they were sacrificed for health reasons. A multi-echo gradient-echo sequence was acquired at every time point and the apparent transverse relaxation rate R{sub 2}* was calculated based on the measured signal decay. At the last time point, an ROI mask with an R{sub 2}* value of greater than 45 s{sup −1} was applied in the area of the external and internal capsule where radiation necrosis was confirmed. A retrospective analysis was performed to determine whether R{sub 2}* values would be able to predict where radiation necrosis would occur. Results: Radiation necrosis was morphologically visible between weeks 22–24 following treatment. Gadolinium MRI and histology confirmed radiation necrosis in the area of MRI enhancement. Our data suggests that there is a trend towards significance in the lesion as early as 12 weeks prior to morphological changes on MRI with significance occurring 6 weeks prior (p≤0.05, p≤0.01 at week 24). Measurements of the R{sub 2}* in the hippocampus did not show any significant difference; however, there are areas of visible R{sub 2}* change within sub-hippocampal regions. Conclusion: R{sub 2}* is a promising method that could be able to predict an underlying disease process that occurs prior to radiation necrosis. The constant increase in R{sub 2}* values suggests a possible neuroinflammatory mechanism rather than an acute vascular event where R{sub 2}* would tend to decrease in the area.

60 APPLIED LIFE SCIENCES↗

X-ray CT Scans - Rodents - Set 2

A collection of x-ray computed tomography scans of specimens from the Museum of Southwestern Biology.

59 BASIC BIOLOGICAL SCIENCES↗

X-ray CT Scans - Rodents - Set 1

A collection of x-ray computed tomography scans of specimens from the Museum of Southwestern Biology.

59 BASIC BIOLOGICAL SCIENCES↗

X-ray CT Scans - Rodents - Set 3

A collection of x-ray computed tomography scans of specimens from the Museum of Southwestern Biology.

59 BASIC BIOLOGICAL SCIENCES↗

X-ray CT Scans - Rodents - Set 4

A collection of x-ray computed tomography scans of specimens from the Museum of Southwestern Biology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray CT Scans - Rodents Set 5

A collection of x-ray computed tomography scans of specimens from the Museum of Southwestern Biology.

59 BASIC BIOLOGICAL SCIENCES↗

The Combined Effects of Pulsed Magnetic Radiation (Diapulse) and Chemotherapy on Tumor Bearing Mice. The Measurement of Rodent Palatal Explants as a Device for Measurement of the Biologic Effects of Nonionic Radiation (EMR)

Simultaneous treatment utilizing pulsed radiowave and cancer chemotherapy significantly extended the life span of mice with Lewis lung transplanted carcinoma. In comparison with nontreated controls, the combination of hydroxyurea and whole body nonionizing EM radiation (at 27.12 MHz) produced differential enhancement of longevity depending on hydroxyurea combined with highest power output achieved by pulsing the radiation 600 times per second; at a 3.9% duty cycle, peak watts = 975 produced the mean extension of life 67% greater than that of the group treated with hydroxyurea alone.

Regelson, W.↗