Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RF ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Characterization of Boron Contamination in Fluorine Implantation using Boron Trifluoride as a Source Material

Fluorine implantation process purity was considered on different types of high current implanters. It was found that implanters equipped with an indirectly heated cathode ion source show an enhanced deep boron contamination compared to a high current implanter using a cold RF-driven multicusp ion source when boron trifluoride is used for fluorine implantations. This contamination is directly related to the source technology and thus, should be considered potentially for any implanter design using hot cathode/hot filament ion source, independently of the manufacturer.The boron contamination results from the generation of double charged boron ions in the arc chamber and the subsequent charge exchange reaction to single charged boron ions taking place between the arc chamber and the extraction electrode. The generation of the double charged boron ions depends mostly on the source parameters, whereas the pressure in the region between the arc chamber and the extraction electrode is mostly responsible for the charge exchange from double charged to single charged ions. The apparent mass covers a wide range, starting at mass 11. A portion of boron ions with energies of (19/11) times higher than fluorine energy has the same magnetic rigidity as fluorine beam and cannot be separated by the analyzer magnet. The earlier described charge exchange effects between the extraction electrode and the entrance to the analyzer magnet, however, generates boron beam with a higher magnetic rigidity compared to fluorine beam and cannot cause boron contamination after mass-separation.The energetic boron contamination was studied as a function of the ion source parameters, such as gas flow, arc voltage, and source magnet settings, as well as analyzing magnet aperture resolution. This allows process optimization reducing boron contamination to the level acceptable for device performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tests on the extracted current density of negative hydrogen ions from a single element of the matrix source

Concepts for the extraction of volume-produced negative hydrogen ions from a rf matrix source (a matrix of small-radius discharges with a planar-coil inductive driving) are presented and discussed based on experimental results for the current densities of the extracted ions and the co-extracted electrons. The experiment has been carried out in a single discharge of the source: a rf discharge with a radius of 2.25 cm inductively driven by a 3.5-turn planar coil. The length of the discharge tube, the area of the reference electrode inserted in the discharge volume, the discharge modes, the magnetic filter and its position along the discharge length, the position of the permanent magnets for the separation of the co-extracted electrons from the extracted ions in the extraction device and the bias applied to its first electrode are considered as factors influencing the extracted currents of negative ions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wave frequency dependence of H{sup -} ion production and extraction in a transformer coupled plasma H{sup -} ion source at SNU

The effect of rf wave frequencies on the production of H{sup -} ion is investigated in a transformer coupled plasma H{sup -} ion source at Seoul National University. A Langmuir probe is installed to measure the plasma density and temperature, and these plasma parameters are correlated to the extracted H{sup -} beam currents at various frequencies. The Langmuir probe is also used to measure the density of H{sup -} ions at the ion source by generating photodetachment with an Nd:YAG laser. The extracted H{sup -} currents decrease to a minimum value until 13 MHz and then, increase as the driving frequency increases from 13 MHz while the relative H{sup -} population measured by photodetachment monotonically decreases as the driving rf frequency increases from 11 MHz to 15 MHz. A potential well formed at the extraction region at high frequencies of more than 13 MHz is considered responsible for the increased H{sup -} beam extraction even with a lower photodetachment signal. The variation in the driving rf frequency not only affects the density and temperature of the plasma but also modifies the plasma potential with the existence of a filtering magnetic field and consequently, influences the extracted H{sup -} current through the extraction as well as formation of H{sup -} ions.

43 PARTICLE ACCELERATORS↗

Computer simulations for rf design of a Spallation Neutron Source external antenna H{sup -} ion source

Electromagnetic modeling of the multicusp external antenna H{sup -} ion source for the Spallation Neutron Source (SNS) has been performed in order to optimize high-power performance. During development of the SNS external antenna ion source, antenna failures due to high voltage and multicusp magnet holder rf heating concerns under stressful operating conditions led to rf characteristics analysis. In rf simulations, the plasma was modeled as an equivalent lossy metal by defining conductivity as {sigma}. Insulation designs along with material selections such as ferrite and Teflon could be included in the computer simulations to compare antenna gap potentials, surface power dissipations, and input impedance at the operating frequencies, 2 and 13.56 MHz. Further modeling and design improvements are outlined in the conclusion.

42 ENGINEERING↗

RF Heating in Electron Cyclotron Resonance Ion Sources

ECRIS-Electron Cyclotron Resonance Ion Sources are able to feed accelerators with intense currents of highly charged ions. In ECRIS a high density-high temperature plasma is generated by means of the Electron Cyclotron Resonance Heating inside a B-min, MHD stable trap. The state of the art about the principal heating mechanisms will be given. The paper will specially discuss the most critical and still open issues concerning the influence of the magnetic field and of the RF frequency on the plasma heating, as well as the impact of possible non-linear pumping wave-to-plasma interactions. The contribution of INFN-LNS will be specifically underlined. A short review on the future perspectives for the design of new generation ion sources will be given in conclusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Metal negative ion beam extraction from a radio frequency ion source

A metal ion source of magnetron magnetic field geometry has been designed and operated with a Cu hollow target. Radio frequency power at 13.56 MHz is directly supplied to the hollow target to maintain plasma discharge and induce self-bias to the target for sputtering. The extraction of positive and negative Cu ion beams have been tested. The ion beam current ratio of Cu{sup +} to Ar{sup +} has reached up to 140% when Ar was used as the discharge support gas. Cu{sup −} ion beam was observed at 50 W RF discharge power and at a higher Ar gas pressure in the ion source. Improvement of poor RF power matching and suppression of electron current is indispensable for a stable Cu{sup −} ion beam production from the source.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion source for tests of ion behavior in the Karlsruhe tritium neutrino experiment beam line

An electron-impact ion source based on photoelectron emission was developed for ionization of gases at pressures below 10{sup -4} mbar in an axial magnetic field in the order of 5 T. The ion source applies only dc fields, which makes it suitable for use in the presence of equipment sensitive to radio-frequency (RF) fields. The ion source was successfully tested under varying conditions regarding pressure, magnetic field, and magnetic-field gradient, and the results were studied with the help of simulations. The processes in the ion source are well understood, and possibilities for further optimization of generated ion currents are clarified.

43 PARTICLE ACCELERATORS↗

Effect of plasma grid bias on extracted currents in the RF driven surface-plasma negative ion source

Extraction of negative ions from the large inductively driven surface-plasma negative ion source was studied. The dependencies of the extracted currents vs plasma grid (PG) bias potential were measured for two modifications of radio-frequency driver with and without Faraday screen, for different hydrogen feeds and for different levels of cesium conditioning. The maximal PG current was independent of driver modification and it was lower in the case of inhibited cesium. The maximal extracted negative ion current depends on the potential difference between the near-PG plasma and the PG bias potentials, while the absolute value of plasma potential in the driver and in the PG area is less important for the negative ion production. The last conclusion confirms the main mechanism of negative ion production through the surface conversion of fast atoms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation and development status of the J-PARC ion source

A cesium-free H{sup −} ion source driven with a LaB{sub 6} filament is being operated at the Japan Proton Accelerator Research Complex (J-PARC) without any serious trouble since the restoration from the March 2011 earthquake. The H{sup −} ion current from the ion source is routinely restricted approximately 19 mA for the lifetime of the filament. In order to increase the beam power at the linac beam operation (January to February 2013), the beam current from the ion source was increased to 22 mA. At this operation, the lifetime of the filament was estimated by the reduction in the filament current. According to the steep reduction in the filament current, the break of the filament was predicted. Although the filament has broken after approximately 10 h from the steep current reduction, the beam operation was restarted approximately 8 h later by the preparation for the exchange of new filament. At the study time for the 3 GeV rapid cycling synchrotron (April 2013), the ion source was operated at approximately 30 mA for 8 days. As a part of the beam current upgrade plan for the J-PARC, the front end test stand consisting of the ion source and the radio frequency quadrupole is under preparation. The RF-driven H{sup −} ion source developed for the J-PARC 2nd stage requirements will be tested at this test stand.

43 PARTICLE ACCELERATORS↗

High-intensity ion sources for accelerators with emphasis on H{sup -} beam formation and transport (invited)

This paper lays out the fundamental working principles of a variety of high-current ion sources for accelerators in a tutorial manner, and gives examples of specific source types such as dc discharge-driven and rf-driven multicusp sources, Penning-type, and electron cyclotron resonance-based sources while discussing those principles, pointing out general performance limits as well as the performance parameters of specific sources. Laser-based, two-chamber, and surface-ionization sources are briefly mentioned. Main aspects of this review are particle feed, ionization mechanism, beam formation, and beam transport. Issues seen with beam formation and low-energy transport of negative hydrogen-ion beams are treated in detail.

43 PARTICLE ACCELERATORS↗

Characterization of the CW starter plasma RF matching network for operating the SNS H{sup −} ion source with lower H{sub 2} flows

The Spallation Neutron Source H{sup −} ion source is operated with a pulsed 2-MHz RF (50-60 kW) to produce the 1-ms long, ∼50 mA H{sup −} beams at 60 Hz. A continuous low power (∼300 W) 13.56-MHz RF plasma, which is initially ignited with a H{sub 2} pressure bump, serves as starter plasma for the pulsed high power 2-MHz RF discharges. To reduce the risk of plasma outages at lower H{sub 2} flow rates which is desired for improved performance of the following radio frequency quadrupole, the 13.56-MHz RF matching network was characterized over a broad range of its two tuning capacitors. The H-α line intensity of the 13.56-MHz RF plasma and the reflected power of the 13.56-MHz RF were mapped against the capacitor settings. Optimal tunes for the maximum H-α intensity are consistent with the optimal tunes for minimum reflected power. Low limits of the H{sub 2} flow rate not causing plasma outages were explored within the range of the map. A tune region that allows lower H{sub 2} flow rate has been identified, which differs from the optimal tune for global minimum reflected power that was mostly used in the past.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concepts for the magnetic design of the MITICA neutral beam test facility ion accelerator

The megavolt ITER injector concept advancement neutral injector test facility will be constituted by a RF-driven negative ion source and by an electrostatic Accelerator, designed to produce a negative Ion with a specific energy up to 1 MeV. The beam is then neutralized in order to obtain a focused 17 MW neutral beam. The magnetic configuration inside the accelerator is of crucial importance for the achievement of a good beam efficiency, with the early deflection of the co-extracted and stripped electrons, and also of the required beam optic quality, with the correction of undesired ion beamlet deflections. Several alternative magnetic design concepts have been considered, comparing in detail the magnetic and beam optics simulation results, evidencing the advantages and drawbacks of each solution both from the physics and engineering point of view.

43 PARTICLE ACCELERATORS↗

Development of an Accelerator Mass Spectrometer based on a Cyclotron

An accelerator mass spectrometer based on a cyclotron has been developed, and a prototype of the injection beam line has been constructed. Mass resolution of the cyclotron is designed to be over 4000. A sawtooth RF buncher in the beam line and a flat-topping RF system for the cyclotron were utilized to enhance beam transmission efficiency, which is a primary factor for improvement compared to previous cyclotron mass spectrometers. The injection beam line comprises an ion source, Einzel lens, RF buncher, 90 deg. dipole magnet and a slit box containing beam diagnostic devices. A carbon beam was measured at the location of the slit box, and beam phase spaces will be measured. The design of a cyclotron magnet was done, and orbit tracking was carried out using cyclotron optics codes. A scheme of radial injection was chosen to place a beam on the equilibrium orbit of the cyclotron. The injection scheme will be optimized after the beam measurements are completed.

43 PARTICLE ACCELERATORS↗

An experimental study of waveguide coupled microwave heating with conventional multicusp negative ion sources

Negative ion production with conventional multicusp plasma chambers utilizing 2.45 GHz microwave heating is demonstrated. The experimental results were obtained with the multicusp plasma chambers and extraction systems of the RF-driven RADIS ion source and the filament driven arc discharge ion source LIISA. A waveguide microwave coupling system, which is almost similar to the one used with the SILHI ion source, was used. The results demonstrate that at least one third of negative ion beam obtained with inductive RF-coupling (RADIS) or arc discharge (LIISA) can be achieved with 1 kW of 2.45 GHz microwave power in CW mode without any modification of the plasma chamber. The co-extracted electron to H{sup −} ratio and the optimum pressure range were observed to be similar for both heating methods. The behaviour of the plasma implies that the energy transfer from the microwaves to the plasma electrons is mainly an off-resonance process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computer simulations for rf design of a Spallation Neutron Source external antenna H ion source

Electromagnetic modeling of the multicusp external antenna H ion source for the Spallation Neutron Source SNS has been performed in order to optimize high-power performance. During development of the SNS external antenna ion source, antenna failures due to high voltage and multicusp magnet holder rf heating concerns under stressful operating conditions led to rf characteristics analysis. In rf simulations, the plasma was modeled as an equivalent lossy metal by defining conductivity as . Insulation designs along with material selections such as ferrite and Teflon could be included in the computer simulations to compare antenna gap potentials, surface power dissipations, and input impedance at the operating frequencies, 2 and 13.56 MHz. Further modeling and design improvements are outlined in the conclusion.

99 GENERAL AND MISCELLANEOUS↗

The SNS External Antenna H- Ion Source

The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure that we will meet our operational commitments as well as provide for future facility upgrades with high reliability, we have developed an RF-driven, H- ion source based on a ceramic aluminum nitride (AlN) plasma chamber [1]. This source is expected to be utilized by the SNS for neutron production starting in 2009. This report details the design of the production source which features an AlN plasma chamber, 2-layer external antenna, cooled-multicusp magnet array, Cs2CrO4 cesium system and a Molybdenum plasma ignition gun. Performance of the production source both on the SNS accelerator and SNS test stand is reported. The source has also been designed to accommodate an elemental Cs system with an external reservoir which has demonstrated unanalyzed beam currents up to ~100mA (60Hz, 1ms) on the SNS ion source test stand.

43 PARTICLE ACCELERATORS↗

THE CONTINUED DEVELOPMENT OF THE SNS EXTERNAL ANTENNA H- ION SOURCE

The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure that the SNS will meet operational commitments as well as provide for future facility upgrades with high reliability, we are developing an RF-driven, H- ion source based on a water-cooled, ceramic aluminum nitride (AlN) plasma chamber. To date, early versions of this source has delivered up to 42 mA to the SNS Front End (FE) and unanalyzed beam currents up to ~ 100mA (60Hz, 1ms) to the ion source test stand. This source was operated on the SNS accelerator from February to April 2009 and produced ~35mA (beam current required by the ramp up plan) with availability of ~97%. During this run several ion source failures identified reliability issues which must be addressed before the source re-enters routine operation: plasma ignition, antenna lifetime, magnet cooling and cooling jacket integrity. This report discusses these issues, details proposed engineering solutions and notes progress to date.

43 PARTICLE ACCELERATORS↗

Thermal and electrostatic simulations of the diagnostic calorimeter for the Source for Production of Ion of Deuterium Extracted from RF plasma beam

To study and optimise negative ion production for the ITER neutral beam injectors, a test facility is under construction in Padova with the aim of testing beam characteristics and to verify the source proper operation. The instrumented calorimeter STRIKE (short-time retractable instrumented kalorimeter experiment) is being developed to characterise the SPIDER (Source for Production of Ion of Deuterium Extracted from RF plasma) beam during short operations. The paper presents an investigation of the response of STRIKE measurement systems. It results that biasing is necessary to cope with the influence of secondary electrons on current measurements; moreover, despite the discretisation of the recorded thermal patterns introduced by the pixels of thermal cameras, a sufficient spatial resolution is expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗