Sources of Emittance in RF Photocathode Injectors

Advances in electron beam technology have been central to creating the current generation of x-ray free electron lasers and ultra-fast electron microscopes. These once exotic devices have become essential tools for basic research and applied science. One important beam technology for both is the electron source which, for many of these instruments, is the photocathode RF gun. The invention of the photocathode gun and the concepts of emittance compensation and beam matching in the presence of space charge and RF forces have made these high-quality beams possible. Achieving even brighter beams requires a taking a finer resolution view of the electron dynamics near the cathode during photoemission and the initial acceleration of the beam. In addition, the high brightness beam is more sensitive to degradation by the optical aberrations of the gun’s RF and magnetic lenses. This paper discusses these topics including the beam properties due to fundamental photoemission physics, space charge effects close to the cathode, and optical distortions introduced by the RF and solenoid fields. Analytic relations for these phenomena are derived and compared with numerical simulations.

43 PARTICLE ACCELERATORS↗

Observation of transverse space charge effects in a multi-beamlet electron bunch produced in a photo-emission electron source

A 'multiple beamlet' experiment aimed at investigating the transverse space charge effect was recently conducted at the Argonne Wakefield Accelerator. The experiment generated a symmetric pattern of 5 beamlets on the photocathode of the RF gun with the drive laser. We explored the evolution of the thereby produced 5 MeV, space-charge dominated electron beamlets in the 2m drift following the RF photocathode gun for various external focusing. Two important effects were observed and benchmarked using the particle-in-cell beam dynamics code IMPACT-T. In this paper, we present our experimental observation and their benchmarking with Impact-T.

43 PARTICLE ACCELERATORS↗

Observation of transverse space charge effects in a mutli-beamlet electron bunch produced in a photo-emission electron source

A 'multiple beamlet' experiment aimed at investigating the transverse space charge effect was recently conducted at the Argonne Wakefield Accelerator. The experiment generated a symmetric pattern of 5 beamlets on the photocathode of the RF gun with the drive laser. We explored the evolution of the thereby produced 5 MeV, space-charge dominated electron beamlets in the 2 m drift following the RF photocathode gun for various external focusing. Two important effects were observed and benchmarked using the particle-in-cell beam dynamics code Impact-T. In this paper, we present our experimental observation and their benchmarking with Impact-T.

43 PARTICLE ACCELERATORS↗

Observation of transverse space charge effects in a multi-beamlet electron bunch produced in a photo-emission electron source.

A 'multiple beamlet' experiment aimed at investigating the transverse space charge effect was recently conducted at the Argonne Wakefield Accelerator. The experiment generated a symmetric pattern of 5 beamlets on the photocathode of the RF gun with the drive laser. We explored the evolution of the thereby produced 5 MeV, space-charge dominated electron beamlets in the 2 m drift following the RF photocathode gun for various external focusing. Two important effects were observed and benchmarked using the particle-in-cell beam dynamics code Impact-T. In this paper, we present our experimental observation and their benchmarking with Impact-T.

43 PARTICLE ACCELERATORS↗

Results of the SLAC LCLS Gun High-Power RF Tests

The beam quality and operational requirements for the Linac Coherent Light Source (LCLS) currently being constructed at SLAC are exceptional, requiring the design of a new RF photocathode gun for the electron source. Based on operational experience at SLAC's GTF and SDL and ATF at BNL as well as other laboratories, the 1.6cell s-band (2856MHz) gun was chosen to be the best electron source for the LCLS, however a significant redesign was necessary to achieve the challenging parameters. Detailed 3-D analysis and design was used to produce near-perfect rotationally symmetric rf fields to achieve the emittance requirement. In addition, the thermo-mechanical design allows the gun to operate at 120Hz and a 140MV/m cathode field, or to an average power dissipation of 4kW. Both average and pulsed heating issues are addressed in the LCLS gun design. The first LCLS gun is now fabricated and has been operated with high-power RF. The results of these high-power tests are presented and discussed.

43 PARTICLE ACCELERATORS↗

Design, development and commissioning of a multi-alkali semiconductor photocathode deposition system for the IUAC Delhi light source photoinjector

A fourth-generation light source, called Delhi Light Source (DLS) based on photocathode-based RF gun has been commissioned at Inter-University Accelerator Centre, New Delhi. Presently, the electron beam is being generated from copper photocathode and the beam is being used for scheduled experiments. Soon, the semiconductor photocathode will be used to produce higher beam current. Here, to develop the semiconductor photocathode, a dedicated photocathode deposition facility was developed in collaboration with Brookhaven national Laboratory (BNL) and has been successfully commissioned and becomes operational at IUAC. This deposition facility is an integrated system with the electron gun and is a unique system as it is capable of producing, preserving (without residual gas poisoning) and in-vacuum transfer of the deposited photocathodes from the deposition chamber up to the RF electron gun. The system is designed to operate under ultra-high vacuum (UHV) and is equipped with load-lock chambers, substrate heating assembly, thickness monitoring via a quartz crystal microbalance (QCM), and an in-situ setup for quantum efficiency (QE) measurements. After testing of all the subsystems and a detailed calibration, the first deposition of a cesium telluride (Cs 2 Te) photocathode was successfully performed on a copper (Cu) substrate. This successful commissioning and initial deposition mark a significant step toward the indigenous photocathode development and lays the groundwork for further research into advanced photo emissive materials at IUAC. This paper will discuss the salient features, installation, commissioning, first semiconductor photocathode deposition and its results.

47 OTHER INSTRUMENTATION↗

Theoretical and experimental analysis of a linear accelerator endowed with single feed coupler with movable short-circuit

The front-end injection systems of the FERMI@Elettra linac produce high brightness electron beams that define the performance of the Free Electron Laser. The photoinjector mainly consists of the radiofrequency (rf) gun and of two S-band rf structures which accelerate the beam. Accelerating structures endowed with a single feed coupler cause deflection and degradation of the electron beam properties, due to the asymmetry of the electromagnetic field. In this paper, a new type of single feed structure with movable short-circuit is proposed. It has the advantage of having only one waveguide input, but we propose a novel design where the dipolar component is reduced. Moreover, the racetrack geometry allows to reduce the quadrupolar component. This paper presents the microwave design and the analysis of the particle motion inside the linac. A prototype has been machined at the Elettra facility to verify the new coupler design and the rf field has been measured by adopting the bead-pull method. The results are here presented, showing good agreement with the expectations.

43 PARTICLE ACCELERATORS↗

RF Design of the LCLS Gun

Final dimensions for the LCLS RF gun are described. This gun, referred to as the LCLS gun, is a modified version of the UCLA/BNL/SLAC 1.6 cell S-Band RF gun [1], referred to as the prototype gun. The changes include a larger mode separation (15 MHz for the LCLS gun vs. 3.5 MHz for the prototype gun), a larger radius at the iris between the 2 cells, a reduced surface field on the curvature of the iris between the two cells, Z power coupling, increased cooling channels for operation at 120 Hz, dual rf feed, deformation tuning of the full cell, and field probes in both cells. Temporal shaping of the klystron pulse, to reduce the average power dissipated in the gun, has also been adopted. By increasing the mode separation, the amplitude of the 0-mode electric field on the cathode decreases from 10% of the peak on axis field for the prototype gun to less than 3% for the LCLS gun for the steady state fields. Beam performance is improved as shown by the PARMELA simulations. The gun should be designed to accept a future load lock system. Modifications follow the recommendations of our RF review committee [2]. Files and reference documents are compiled in Section IV.

43 PARTICLE ACCELERATORS↗

Robust RF Photocathodes (Phase II Final Report)

This program addressed requirements for photocathodes with high quantum efficiency (QE) and long lifetimes. Currently, photocathodes with QEs above 1% exhibit lifetimes measured in a few hours. This is unacceptable for commercial devices using photocathodes as the electron source. This includes accelerators for industrial, medical, defense, and educational applications as well as emerging applications, such as time resolved electron microscopy. Calabazas Creek Research, Inc. (CCR) and the University of Maryland (UMD) attempted to develop reservoir photocathodes that dramatically increased lifetime and increased the ability to recover from contaminating events, such as loss of system vacuum. The Phase I program demonstrated the viability of the reservoir approach for higher QE cathodes. The Phase II program focused on design, fabrication, and delivery. This included increasing understanding of photocathode physics, investigating design options, addressing performance issues, and developing fabrication and packaging techniques leading to commercial products. The initial task identified specific photocathode materials that provide high QE and are compatible with the reservoir approach. The goal was that these photocathodes be manufacturable in a production environment, understanding that the “environment” is highly specialized. The photocathode geometry was modified to address several photogun performance issues related primarily to emittance. A goal was to reduce or eliminate thermal emittance issues arising from the reservoir heater. The program developed fabrication, handling, and transport techniques and facilities to allow commercial photocathode production for certain materials. Not only was complex chemistry involved, but practical issues of transporting and installing the cathodes into user systems were addressed. A critical goal was demonstration of reservoir photocathodes in operating RF guns, where performance could be directly measured. Success depended on clear demonstration that the cathodes could be produced, delivered, installed, and provide the required performance. The principal effort in this program was to develop reservoir cesium antimonide photocathodes. Cesium antimonide cathodes provide a work function in excess of the 1% goal, while the current generation exhibits lifetimes measured in hours. The reservoir in CCRs’ controlled porosity reservoir (CPR) cathodes provides a mechanism for replacing cesium evaporating from the surface by transporting replacement cesium from the reservoir. This is accomplished by gently heating the reservoir to induce cesium diffusion through micron-scale pores in the reservoir cap and photocathode emitter. Experiments at the UMD determined that cesium diffused from the reservoir would only react with antimony on the surface if the temperature exceeded 300C. At this temperature, however, the surface cesium evaporated faster than it could be replenished from the reservoir. Consequently, the QE decreased each time recessiation was attempted. This appears to be a fundamental problem with this approach. The sections below provide information on accomplishments for each task in the program. Once the issue with cesium antimonide cathodes was identified, CCR refocused the program to begin investigation of graphene coated photocathodes in collaboration with SLAC National Accelerator Laboratory (SLAC). The photocathode test chamber developed in the program was transferred to SLAC for use in the graphene research. This is described below in a task added to the program.

43 PARTICLE ACCELERATORS↗

Cathode Ion Bombardment in RF Photoguns

In this paper, we use the method of rapid oscillating field to solve the equation of ion motion in an RF gun. We apply the method to the BNL 1/2-cell SRF photogun and demonstrate that a significant portion of ions produced in the gun can reach the cathode if no special precautions are taken. Also, the paper proposes a simple mitigation recipe that can reduce the rate of ion bombardment.

43 PARTICLE ACCELERATORS↗

High Brightness Electron Beam Studies at the NSLS SDL

Experimental optimization of electron beam brightness at the NSLS SDL is reported in this paper. Using a high quantum efficiency (QE) Mg metal cathode and the S-band BNL-type RF gun, we have systematically studied electron beams transverse and longitudinal emittance. The measured thermal emittance for the Mg cathode is 0.85{+-}0.04 mm-mrad/mm, which contradicts the current thermal emittance model. For a 50 pC beam, measured normalized transverse and longitudinal RMS emittance are 0.6 mm-mrd and 5.2 ps-keV, respectively. The smallest projected transverse emittance observed for a 20 pC charge is 0.15 {+-} 0.02 mm-mrad.

43 PARTICLE ACCELERATORS↗

The Polarized SRF Gun Experiment

An experiment is under way to prove the feasibility of a super-conducting RF gun for the production of polarized electrons. We report on the progress of the experiment and on simulations predicting the possibility of success.

43 PARTICLE ACCELERATORS↗

R and D energy recovery LINAC at Brookhaven National Laboratory

Collider Accelerator Department at BNL is in the final stages of developing the 20-MeV R and D energy recovery linac with super-conducting 2.5 MeV RF gun and single-mode super-conducting 5-cell RF linac. This unique facility aims to address many outstanding questions relevant for high current (up to 0.5 A of average current), high brightness energy-recovery linacs with novel ZigZag-type merger. Recent development in the R and D ERL plans include gun and 5-cell cavity (G5) test and possibility of using R and D ERL for proof-of-principle test of Coherent Electron Cooling at RHIC.

43 PARTICLE ACCELERATORS↗

R&D Energy Recovery Linac at Brookhaven National Laboratory

Collider Accelerator Department at BNL is in the final stages of developing the 20-MeV R&D energy recovery linac with super-conducting 2.5 MeV RF gun and single-mode super-conducting 5-cell RF linac. This unique facility aims to address many outstanding questions relevant for high current (up to 0.5 A of average current), high brightness energy-recovery linacs with novel Zigzag-type merger. We present the performance of the R&D ERL elements and detailed commissioning plan.

43 PARTICLE ACCELERATORS↗

The polarized SRF gun experiment

An experiment is under way to prove the feasibility of a super-conducting RF gun for the production of polarized electrons. We report on the progress of the experiment and on simulations predicting the possibility of success.

43 PARTICLE ACCELERATORS↗

Particle-In-Cell/Monte Carlo Simulation of Ion Back BomBardment in a High Average Current RF Photo-Gun

In this paper, we report on study of ion back bombardment in a high average current radio-frequency (RF) photo-gun using a particle-in-cell/Monte Carlo simulation method. Using this method, we systematically studied effects of gas pressure, RF frequency, RF initial phase, electric field profile, magnetic field, laser repetition rate, different ion species on ion particle line density distribution, kinetic energy spectrum, and ion power line density distribution back bombardment onto the photocathode. Those simulation results suggested that effects of ion back bombardment could increase linearly with the background gas pressure and laser repetition rate. The RF frequency has significantly affected the ion motion inside the gun so that the ion power deposition on the photocathode in an RF gun can be several orders of magnitude lower than that in a DC gun. The ion back bombardment can be minimized by appropriately choosing the electric field profile and the initial phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation study on the emittance compensation of off-axis emitted beam in RF photoinjector

To make full use of the photocathode material and improve its quantum efficiency lifetime, it can be necessary to operate the laser away from the cathode center in photoinjectors. In RF guns, the off-axis emitted beam will see a time-dependent RF effect, which would generate a significant growth in transverse emittance. It has been demonstrated that such an emittance growth can be almost completely compensated by orienting the beam on a proper orbit in the downstream RF cavities along the injector [1]. In this paper we analyze in detail the simulation techniques used in reference [1] and the issues associated with them. The optimization of photoinjector systems involving off-axis beams is a challenging problem. To solve this problem, one needs advanced simulation tools including both genetic algorithms and an efficient algorithm for 3D space charge. In this paper, we report on simulation studies where the two codes ASTRA and IMPACT-T are used jointly to overcome these challenges, in order to optimize a system designed to compensate for the emittance growth in a beam emitted off axis.

36 MATERIALS SCIENCE↗

Observation of Long-Range Wakefield Effects Generated in an Off-Resonance Tesla-Type Cavity

The interest in controlling emittance dilution effects due to off-axis beam transport in accelerator cavities and the resulting dipolar modes is especially important for the facilities with lower emittance beams. The Fermilab Accelerator Science and Technology (FAST) facility has a unique configuration of two single cavities after the photocathode rf gun followed by a cryomodule. The second capture cavity (CC2) was run 15 kHz off resonance and without rf power while a 25-MeV beam was injected into it. The beam centroid effects were tracked by 10 rf button BPMs with bunch-by-bunch position readout capability downstream in a 12-m drift. Possible LRW effects seemed to dominate our previously observed near-resonant HOM effects at mode 14 in this cavity. This mode also shifted in frequency compared to that of the tuned case based on direct measurements. Submacropulse vertical position slewing of 1400 microns at 11 m downstream was observed with a 125 pC/bunch, 50 bunches per macropulse, and 25-MeV beam. The y-position slew amplitudes as a function of z were also measured. Horizontal positions also showed a slew effect. Both are emittance-dilution effects which one wants to mitigate.