Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Double and triple-harmonic RF buckets and their use for bunch squeezing in AGS

For the past several years we have merged bunches in AGS in order to achieve the desired intensity per bunch prior to injection into RHIC. The merging is done on a flat porch at or above AGS injection energy. Because the merges involve the reduction of the RF harmonic number by a factor of 2 (for a 2 to 1 merge) and then a factor of 3 (for a 3 to 1 merge), one requires RF frequencies 6hf s , 3hf s , 2hf s and hf s , where f s is the revolution frequency on the porch and h = 4 is the fundamental harmonic number. The standard AGS RF cavities cannot operate at the lowest frequencies 2hf s and hf s ; these are provided by two modified cavities. Upon completion of the merges, the bunches are sitting in harmonic h buckets. In order to be accelerated they need to be squeezed into harmonic 3h buckets. This is accomplished by producing a double-harmonic bucket in which harmonics h and 2h act in concert, and then a triple-harmonic bucket in which harmonics h, 2h, and 3h act in concert. Simulations have shown that the squeeze presents an acceptance bottleneck which limits the longitudinal emittance that can be put into the harmonic 3h bucket. In this note the areas of the double and triple-harmonic buckets are calculated explicitly, and it is shown that these go through a minimum as the RF voltages are raised to the desired values. Several RF voltage ranges are examined, and the acceptance bottleneck is determined for each of these. Finally, the acceptance bottleneck for Au77+ bunches in AGS is calculated for several RF voltage ranges. The main result is that the RF voltages for the low-frequency harmonic h and 2h cavities both must be at least 22 kV in order to achieve an acceptance of 0:6 eV s per nucleon. If the harmonic h and 2h voltages are 15 and 22 kV, respectively, then the acceptance is reduced to 0:548 eV s per nucleon.

43 PARTICLE ACCELERATORS↗

EFFICIENT FAN-OUT RF VECTOR CONTROL ALGORITHM *

A new RF vector control algorithm for fan-out power distribution using reactive transmission line circuit parameters for maximum power efficiency is presented. This control with fan-out power distribution system is considered valuable for large scale SRF accelerator systems to reduce construction costs and save on operating costs. In a fan-out RF power distribution system, feeding multiple accelerating cavities with a single RF power generator can be accomplished by adjusting phase delays between the load cavities and reactive loads at the cavity inputs for independent control of cavity RF voltage vectors. In this approach, the RF control parameters for a set of specified cavity RF voltage vectors is determined for an entire fan-out system. The reactive loads and phase shifts can be realized using high power RF phase shifters.

43 PARTICLE ACCELERATORS↗

Studies of RF Noise Induced Bunch Lengthening at the LHC

Radio Frequency (RF) noise induced bunch lengthening can strongly affect the Large Hadron Collider (LHC) performance through luminosity reduction, particle loss, and other effects. This work presents measurements from the LHC that better quantify the relationship between the RF noise and longitudinal emittance blowup and identify the performance limiting RF components. The experiments presented in this paper confirmed the predicted effects on the LHC bunch length growth. Dedicated measurements were conducted in the LHC to gain insight in the effect of RF noise to the longitudinal beam diffusion. It was evident that the growth rate of the bunch length is strongly related to the accelerating voltage phase noise power spectral density around f{sub s} + kf{sub rev}, as predicted in [4]. The noise threshold for 2.5 ps/hr growth was estimated to -101 dBc/Hz (SSB flat noise spectral density from f{sub s} to the edge of the closed loop bandwidth). A 9 dB margin is achieved with the current RF configuration and the BPL on. With this formalism it is now possible to estimate the effect of different operational and technical RF configurations on the LHC beam diffusion. This formalism could also be useful for the design of future RF systems and the budgeting of the allowed noise.

43 PARTICLE ACCELERATORS↗

Predictions of VRF on a Langmuir Probe under the RF Heating Spiral on the Divertor Floor on NSTX-U

RF heating deposition spirals are observed on the divertor plates on NSTX as shown in for a NB plus RF heating case. It has been shown that the RF spiral is tracked quite well by the spiral mapping of the strike points on the divertor plate of magnetic field lines passing in front of the high harmonic fast wave (HHFW) antenna on NSTX. Indeed, both current instrumented tiles and Langmuir probes respond to the spiral when it is positioned over them. In particular, a positive increment in tile current (collection of electrons) is obtained when the spiral is over the tile. This current can be due to RF rectification and/or RF heating of the scrape off layer (SOL) plasma along the magnetic field lines passing in front of the the HHFW antenna. It is important to determine quantitatively the relative contributions of these processes. Here we explore the properties of the characteristics of probes on the lower divertor plate to determine the likelyhood that the primary cause of the RF heat deposition is RF rectification.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LHC Beam Diffusion Dependence on RF Noise: Models And Measurements

Radio Frequency (RF) accelerating system noise and non-idealities can have detrimental impact on the LHC performance through longitudinal motion and longitudinal emittance growth. A theoretical formalism has been developed to relate the beam and RF loop dynamics with the bunch length growth [1]. Measurements were conducted at LHC to validate the formalism, determine the performance limiting RF components, and provide the foundation for beam diffusion estimates for higher energies and intensities. A brief summary of these results is presented in this work. During a long store, the relation between the energy lost to synchrotron radiation and the noise injected to the beam by the RF accelerating voltage determines the growth of the bunch energy spread and longitudinal emittance. Since the proton synchrotron radiation in the LHC is very low, the beam diffusion is extremely sensitive to RF perturbations. The theoretical formalism presented in [1], suggests that the noise experienced by the beam depends on the cavity phase noise power spectrum, filtered by the beam transfer function, and aliased due to the periodic sampling of the accelerating voltage signal V{sub c}. Additionally, the dependence of the RF accelerating cavity noise spectrum on the Low Level RF (LLRF) configurations has been predicted using time-domain simulations and models [2]. In this work, initial measurements at the LHC supporting the above theoretical formalism and simulation predictions are presented.

43 PARTICLE ACCELERATORS↗

Commissioning of the LHC Low Level RF System Remote Configuration Tools

The LHC Low Level RF system (LLRF) is a complex multi-loop system used to regulate the superconductive cavity gap voltage as well as to reduce the impedance presented by RF stations to the beam. The RF system can have a profound impact on the stability of the beam; a mis-configured RF system has the potential of causing longitudinal instabilities, beam diffusion and beam loss. To configure the RF station for operation, a set of parameters in the LLRF multi-loop system have to be defined. Initial system commissioning as well as ongoing operation requires a consistent method of computer based remote measurement and model-based design of each RF station feedback system. This paper describes the suite of Matlab tools used for configuring the LHC RF system during the start up in Nov2009-Feb2010. We present a brief overview of the tool, examples of commissioning results, and basics of the model-based design algorithms. This work complements our previous presentation, where the algorithms and methodology followed in the tools were described.

43 PARTICLE ACCELERATORS↗

Effect of RF Power on Structural, Magnetic, and Optical Properties of CoFe{sub 2}O{sub 4} Thin Films

The thin films of CoFe{sub 2}O{sub 4} were deposited on glass substrates by radio-frequency (RF) sputtering. The effect of RF power variation from 60–120 W on the structure, magnetic, and optical properties of the as-deposited films and films annealed at 500 °C was studied. The magnetic parameters of the film, i.e., in-plane coercivity (H{sub c}), saturation magnetization (M{sub s}), and remanence (M{sub r}) increase as RF power is increased from 60 to 80 W followed by a decreasing trend with further increase in RF power to 120 W. Annealing of the film significantly improves the magnetic properties. The largest grain size and the best crystallinity of the film are obtained for the film deposited at 80 W of RF power. The thin films exhibited 70–80% optical transmittance. Optical band gap (E{sub g}) depends on the RF power and grain size, and it varies between 2.08 and 2.16 eV for the as-deposited films and between 2.16 and 2.30 eV for the annealed films. The study shows that RF power used for depositing the film has strong effect on the microstructure and properties of the film.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

rf-driven ion sources for industrial applications (invited) (abstract)

The Plasma and Ion Source Technology Group at the Lawrence Berkeley National Laboratory have been developing rf-driven ion sources for the last two decades. These sources are being used to generate both positive and negative ion beams. Some of these sources are operating in particle accelerators such as the Spallation Neutron Source (SNS) at Oak Ridge, while others are being employed in various industrial ion beam systems. There are four areas where the rf-driven ion sources are commonly used in industry. (1) In semiconductor manufacturing, rf-driven sources have found important applications in plasma etching, ion beam implantation, and ion beam lithography. (2) In material analysis and surface modification, miniature rf-ion sources can be found in focused ion beam systems. They can provide ion beams of essentially any element in the Periodic Table. The newly developed combined rf ion-electron beam unit improves greatly the performance of the secondary ion mass spectrometry tool. (3) For neutron production, rf ion source is a major component of compact, high flux D-D, D-T, or T-T neutron generators. These neutron sources are now being employed in boron neutron capture therapy (BNCT) as well as in neutron imaging and material interrogation. (4) Large area rf-driven ion source will be used in an industrial design neutral beam diagnostic system for probing fusion plasmas. Such sources can be easily scaled to provide large ion beam current for future fusion reactor applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A compact low-level RF control system for advanced concept compact electron linear accelerator

A compact low-level RF (LLRF) control system based on RF system-on-chip (RFSoC) technology has been designed for the Advanced Concept Compact Electron Linear-accelerator (ACCEL) program, which has challenging requirements in both RF performance and size, weight, and power consumption (SWaP). The compact LLRF solution employs the direct RF sampling technique of RFSoC, which samples the RF signals directly without any analog upconversion and downconversion. Compared with the conventional heterodyne based architecture used for the LLRF system of a linear accelerator (LINAC), the elimination of analog mixers can significantly reduce the size and weight of the system, especially with LINAC requiring a larger number of RF channels. Based on the requirements of ACCEL, a prototype LLRF platform has been developed, and the control schemes have been proposed. The prototype LLRF system demonstrated magnitude and phase fluctuation levels below 1% and 1° on the flattop of a 2 μs RF pulse. The LLRF control schemes proposed for ACCEL are implemented with a prototype hardware platform. In conclusion, this paper will introduce the new compact LLRF solution and summarize a selection of experimental test results of the prototype itself and with the accelerating structure cavities designed for ACCEL.

Liu, C. [SLAC National Accelerator Laboratory (SLA↗

Calculation of RF sheath properties from surface wave-fields: a post-processing method

In ion cyclotron range of frequency (ICRF) experiments in fusion research devices, radio frequency (RF) sheaths form where plasma, strong RF wave fields and material surfaces coexist. These RF sheaths affect plasma material interactions such as sputtering and localized power deposition, as well as the global RF wave fields themselves. RF sheaths may be modeled by employing a sheath boundary condition (BC) in place of the more customary conducting wall BC; however, there are still many ICRF computer codes that do not implement the sheath BC. In this paper we present a method for post-processing results obtained with the conducting wall BC. The post-processing method produces results that are equivalent to those that would have been obtained with the RF sheath BC, under certain assumptions. We found the post-processing method is also useful for verification of sheath BC implementations and as a guide to interpretation and understanding of the role of RF sheaths and their interactions with the waves that drive them.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RF-Net 2: fast inference of virus reassortment and hybridization networks

Abstract Motivation A phylogenetic network is a powerful model to represent entangled evolutionary histories with both divergent (speciation) and convergent (e.g. hybridization, reassortment, recombination) evolution. The standard approach to inference of hybridization networks is to (i) reconstruct rooted gene trees and (ii) leverage gene tree discordance for network inference. Recently, we introduced a method called RF-Net for accurate inference of virus reassortment and hybridization networks from input gene trees in the presence of errors commonly found in phylogenetic trees. While RF-Net demonstrated the ability to accurately infer networks with up to four reticulations from erroneous input gene trees, its application was limited by the number of reticulations it could handle in a reasonable amount of time. This limitation is particularly restrictive in the inference of the evolutionary history of segmented RNA viruses such as influenza A virus (IAV), where reassortment is one of the major mechanisms shaping the evolution of these pathogens. Results Here, we expand the functionality of RF-Net that makes it significantly more applicable in practice. Crucially, we introduce a fast extension to RF-Net, called Fast-RF-Net, that can handle large numbers of reticulations without sacrificing accuracy. In addition, we develop automatic stopping criteria to select the appropriate number of reticulations heuristically and implement a feature for RF-Net to output error-corrected input gene trees. We then conduct a comprehensive study of the original method and its novel extensions and confirm their efficacy in practice using extensive simulation and empirical IAV evolutionary analyses. Availability and implementation RF-Net 2 is available at https://github.com/flu-crew/rf-net-2. Supplementary information Supplementary data are available at Bioinformatics online.

Markin, Alexey (ORCID:0000000332809050)↗

High-Sensitivity rf Detection Using an Optically Pumped Comagnetometer Based on Natural-Abundance Rubidium with Active Ambient-Field Cancellation

To detect a specific radio-frequency (rf) magnetic field, rf optically pumped magnetometers (OPMs) require a static magnetic field to set the Larmor frequency of the atoms equal to the frequency of interest. However, unshielded and variable magnetic field environments (e.g., an rf OPM on a moving platform) pose a problem for rf OPM operation. Here, we demonstrate the use of a natural-abundance rubidium vapor to make a comagnetometer to address this challenge. Our implementation builds upon the simultaneous application of several OPM techniques within the same vapor cell. First, we use a modified implementation of an OPM variometer based on 87 Rb to detect and actively cancel unwanted external fields at frequencies ≲60 Hz using active feedback to a set of field control coils. In this experiment, we exploit this stabilized field environment to implement a high-sensitivity rf magnetometer using 85 Rb. Using this approach, we demonstrate the ability to measure rf fields with a sensitivity of approximately 9 fT Hz -1/2 inside a magnetic shield in the presence of an applied field of approximately 20 μT along three mutually orthogonal directions. This demonstration opens up a path toward completely unshielded operation of a high-sensitivity rf OPM.

47 OTHER INSTRUMENTATION↗

Synthesis of rutherfordium isotopes in the {sup 238}U({sup 26}Mg, xn){sup 264-x}Rf reaction and study of their decay properties

Isotopes of rutherfordium ({sup 258-261}Rf) were produced in irradiations of {sup 238}U targets with {sup 26}Mg beams. Excitation functions were measured for the 4n,5n, and 6n exit channels. Production of {sup 261}Rf in the 3n exit channel with a cross section of 28{sub -26}{sup +92} pb was observed. {alpha}-decay of {sup 258}Rf was observed for the first time with an {alpha}-particle energy of 9.05 {+-} 0.03 MeV and an {alpha}/total-decay branching ratio of 0.31 {+-} 0.11. In {sup 259}Rf, the electron capture/total-decay branching ratio was measured to be 0.15{+-}0.04. The measured half-lives for {sup 258}Rf, {sup 259}Rf, and {sup 260}Rf were 14.7{sub -1.0}{sup +1.2} ms, 2.5{sub -0.3}{sup +0.4} s, and 22.2{sub -2.4}{sup +3.0} ms, respectively, in agreement with literature data. The systematics of the {alpha}-decay Q-values and of the partial spontaneous fission half-lives were evaluated for even-even nuclides in the region of the N=152,Z=100 deformed shell. The influence of the N=152 shell on the {alpha}-decay Q-values for rutherfordium was observed to be similar to that of the lighter elements (96{<=}Z{<=}102). However, the N=152 shell does not stabilize the rutherfordium isotopes against spontaneous fission, as it does in the lighter elements (96{<=}Z{<=}102)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pressurized H 2 rf Cavities in Ionizing Beams and Magnetic Fields

A major technological challenge in building a muon cooling channel is operating RF cavities in multi-tesla external magnetic fields. We report the first experimental characterization of a high pressure gas-filled 805 MHz RF cavity for use with intense ionizing beams and strong external magnetic fields. RF power consumption by beam-induced plasma was investigated with hydrogen and deuterium gases with pressures between 20 and 100 atm and peak RF gradients between 5 and 50 MV/m. The energy absorption per ion pair-RF cycle ranges from 10-18 to 10-16 J. The low pressure case agrees well with an analytical model based on electron and ion mobilities. Varying concentrations of oxygen gas were investigated to remove free electrons from the cavity and reduce the RF power consumption. Measurements of the electron attachment time to oxygen and rate of ion-ion recombination were also made. Additionally, we demonstrate the operation of the gas-filled RF cavity in a solenoidal field of up to 3 T, finding no major magnetic field dependence. These results indicate that a high pressure gas-filled cavity is potentially a viable technology for muon ionization cooling.

Chung, M.↗

Deposition of aluminum-doped zinc oxide thin films for optical applications using rf and dc magnetron sputter deposition

Aluminum-doped zinc oxide films were deposited by dc and rf magnetron sputtering from ZnO(98%)Al{sub 2}O{sub 3}(2%) target at room temperature on silicon and glass substrates under a variety of process conditions with the goal of attaining the highest transmittance and lowest resistivity for photovoltaic applications. The magnetron power and pressure were varied. For many dielectric deposition systems, added oxygen is necessary to achieve the appropriate stoichiometry. The effect of oxygen on film properties was then studied by varying the oxygen partial pressure from 1.5x10{sup -5} to 4.0x10{sup -5} T at a constant Ar pressure, with the result that any added oxygen was deleterious. Films deposited under power, pressure, and low-oxygen conditions were then characterized for electrical and optical properties. Following this, the dc and rf sputtered films were annealed at up to 400 deg. C seconds using rapid thermal annealing (RTA), and the influence of annealing on resistivity, transmittance, band gap, as well as grain growth and stress was studied. The effect of RTA was immediate and quite significant on dc films while the effect on rf films was not as profound. As-deposited rf films had a higher average transmittance (87%) and lower resistivity (5.5x10{sup -4} {Omega} cm) compared to as-deposited dc films (84.2% and 8.9x10{sup -4} {Omega} cm). On the other hand, after RTA at 400 deg. C for 60 s, dc films exhibited better average transmittance (92.3%) and resistivity (2.9x10{sup -4} {Omega} cm) than rf films (90.7% and 4.0x10{sup -4} {Omega} cm). The band gap of dc films increased from 3.55 to 3.80 eV while that of rf films increased from 3.76 to 3.85 eV. Finally, dc and rf films were textured in 0.1% HCl and compared to U-type Asahi glass for resistivity and transmittance.

36 MATERIALS SCIENCE↗

SU-E-T-558: An Exploratory RF Pulse Sequence Technique Used to Induce Differential Heating in Tissues Containing Iron Oxide Nanoparticles for a Possible Hyperthermic Adjuvant Effect to Radiotherapy

Purpose: In pre-clinical trials of cancer thermotherapy, hyperthermia can be induced by exposing localized super-paramagnetic iron oxide nanoparticles (SPION) to external alternating magnetic fields generated by a solenoid electrical circuit (Zhao et al., Theranostics 2012). Alternatively, an RF pulse technique implemented in a regular MRI system is explored as a possible hyperthermia induction technique . Methods: A new thermal RF pulse sequence was developed using the Philips pulse programming tool for the 3T Ingenia MRI system to provide a sinusoidal magnetic field alternating at the frequency of 1.43 kHz (multiples of sine waves of 0.7 ms period) before each excitation RF pulse for imaging. The duration of each thermal RF pulse routine was approximately 3 min, and the thermal pulse was applied multiple times to a phantom that contains different concentrations (high, medium and low) of SPION samples. After applying the thermal pulse each time, the temperature change was estimated by measuring the phase changes in the T1-weighted inversion-prepared multi-shot turbo field echo (TFE) sequence (TR=5.5 ms, TE=2.7 ms, inversion time=200 ms). Results: The phase values and relative differences among them changed as the number of applied thermal RF pulses increased. After the 5th application of the thermal RF pulse, the relative phase differences increased significantly, suggesting the thermal activation of the SPION. The increase of the phase difference was approximately linear with the SPION concentration. Conclusion: A sinusoidal RF pulse from the MRI system may be utilized to selectively thermally activate tissues containing super-paramagnetic iron oxide nanoparticles.

60 APPLIED LIFE SCIENCES↗

Monitoring local heating around an interventional MRI antenna with RF radiometry

Purpose: Radiofrequency (RF) radiometry uses thermal noise detected by an antenna to measure the temperature of objects independent of medical imaging technologies such as magnetic resonance imaging (MRI). Here, an active interventional MRI antenna can be deployed as a RF radiometer to measure local heating, as a possible new method of monitoring device safety and thermal therapy. Methods: A 128 MHz radiometer receiver was fabricated to measure the RF noise voltage from an interventional 3 T MRI loopless antenna and calibrated for temperature in a uniformly heated bioanalogous gel phantom. Local heating (ΔT) was induced using the antenna for RF transmission and measured by RF radiometry, fiber-optic thermal sensors, and MRI thermometry. The spatial thermal sensitivity of the antenna radiometer was numerically computed using a method-of-moment electric field analyses. The gel’s thermal conductivity was measured by MRI thermometry, and the localized time-dependent ΔT distribution computed from the bioheat transfer equation and compared with radiometry measurements. A “H-factor” relating the 1 g-averaged ΔT to the radiometric temperature was introduced to estimate peak temperature rise in the antenna’s sensitive region. Results: The loopless antenna radiometer linearly tracked temperature inside a thermally equilibrated phantom up to 73 °C to within ±0.3 °C at a 2 Hz sample rate. Computed and MRI thermometric measures of peak ΔT agreed within 13%. The peak 1 g-average temperature was H = 1.36 ± 0.02 times higher than the radiometric temperature for any media with a thermal conductivity of 0.15–0.50 (W/m)/K, indicating that the radiometer can measure peak 1 g-averaged ΔT in physiologically relevant tissue within ±0.4 °C. Conclusions: Active internal MRI detectors can serve as RF radiometers at the MRI frequency to provide accurate independent measures of local and peak temperature without the artifacts that can accompany MRI thermometry or the extra space needed to accommodate alternative thermal transducers. A RF radiometer could be integrated in a MRI scanner to permit “self-monitoring” for assuring device safety and/or monitoring delivery of thermal therapy.

60 APPLIED LIFE SCIENCES↗

Nanostructured crystals of fluorite phases Sr{sub 1−x}R{sub x}F{sub 2+x} (R Are Rare Earth Elements) and their ordering: 10. Ordering under spontaneous crystallization and annealing of Sr{sub 1−x}R{sub x}F{sub 2+x} Alloys (R = Tb-Lu, Y) with 23.8–36.1 mol % RF{sub 3}

The products of spontaneous crystallization (at a cooling rate of ∼200 K/min) of Sr{sub 1−x}R{sub x}F{sub 2+x} melts in the homogeneity range of the fluorite phase have been investigated. Thirty-two irrational compositions with 23.8–36.1 mol % RF{sub 3} and eight rational Sr{sub 2}RF{sub 7} compositions are obtained. With respect to the RF{sub 3} content, these compositions form five groups: (1) Sr{sub 0.762}R{sub 0.238}F{sub 2.238} (23.8% RF{sub 3}), (2) Sr{sub 0.744}R{sub 0.256}F{sub 2.256} (25.6%), (3) Sr{sub 0.718}R{sub 0.282}F{sub 2.282} (28.2%), (4) Sr{sub 2}RF{sub 7} (33.3%), and (5) Sr{sub 0.639}R{sub 0.361}F{sub 2.361} (36.1%). R = Tb-Lu, Y for all groups. Quenching melts of group 5 with R = Tb, Dy, and Ho leads to the formation of ordered phases with the trigonal distortion of the rhβ-Na{sub 7}Zr{sub 6}F{sub 31} type, while for melts of group 5 with R = Lu, quenching yields a phase of the trigonal rhα′-Sr{sub 4}Lu{sub 3}F{sub 17} type. In group 5 with R = Y, Er, Tm, or Yb and in groups 1–4 with all REEs, fluorite phases are formed. Annealing at 900 ± 20°C for 96 h with subsequent cooling at a rate of ∼200 K/min expands the variety of ordered phases: a phase with a new r type of orthorhombic distortion is formed in group 1 with R = Lu, in group 2 with R = Tm or Lu, and in group 3 with R = Ho-Lu, Y; a t-Sr{sub 2}RF{sub 7} phase with tetragonal distortion is formed in group 4 with R = Tb-Er, Y; and a phase of trigonal rhα′ type is formed in group 5 with R = Y, Yb, or Lu. A fluorite phase arises in group 1 with R = Tb-Lu, Y as a result of quenching and annealing. The tendency to ordering becomes more pronounced with an increase in the RF{sub 3} content and REE atomic number. The annealing conditions do not provide equilibrium or the completely ordered state of all alloys.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗