Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESPIRATORY RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Portable Unit for Metabolic Analysis

The Portable Unit for Metabolic Analysis (PUMA) is an instrument that measures several quantities indicative of human metabolic function. Specifically, this instrument makes time-resolved measurements of temperature, pressure, flow, and the partial pressures of oxygen and carbon dioxide in breath during both inhalation and exhalation. Portable instruments for measuring these quantities have been commercially available, but the response times of those instruments are too long to enable temporal resolution of phenomena on the time scales of human respiration cycles. In contrast, the response time of the PUMA is significantly shorter than characteristic times of human respiration phenomena, making it possible to analyze varying metabolic parameters, not only on sequential breath cycles but also at successive phases of inhalation and exhalation within the same breath cycle. In operation, the PUMA is positioned to sample breath near the subject s mouth. Commercial off-the-shelf sensors are used for three of the measurements: a miniature pressure transducer for pressure, a thermistor for temperature, and an ultrasonic sensor for flow. Sensors developed at Glenn Research Center are used for measuring the partial pressures of oxygen and carbon dioxide: The carbon dioxide sensor exploits the relatively strong absorption of infrared light by carbon dioxide. Light from an infrared source passes through the stream of inhaled or exhaled gas and is focused on an infrared- sensitive photodetector. The oxygen sensor exploits the effect of oxygen in quenching the fluorescence of ruthenium-doped organic molecules in a dye on the tip of an optical fiber. A blue laser diode is used to excite the fluorescence, and the optical fiber carries the fluorescent light to a photodiode, the temporal variation of the output of which bears a known relationship with the rate of quenching of fluorescence and, hence, with the partial pressure of oxygen. The outputs of the sensors are digitized, preprocessed by a small onboard computer, and then sent wirelessly to a desktop computer, where the collected data are analyzed and displayed. In addition to the raw data on temperature, pressure, flow, and mole fractions of oxygen and carbon dioxide, the display can include volumetric oxygen consumption, volumetric carbon dioxide production, respiratory equivalent ratio, and volumetric flow rate of exhaled gas.

Dietrich, Daniel L.↗

Statistical Uncertainty of Inhalation Dose Coefficients: Impact of Particle Deposition in ICRP 66 Human Respiratory Tract Model

Inhaled radioactive materials can pose a long-term health concern, as the material can be incorporated into the body’s metabolic pathways and remain in organs and tissues for extended durations. During the retention period, the radioactive material may localize in a source organ and irradiate adjacent target organs and tissues. Distribution of these materials changes over time, requiring biokinetic modeling to evaluate their movement through various tissues and organs. The evolving distribution depends on multiple inputs characterizing the inhaled material, such as particle size and size distribution, particle density, aspect ratio, specific radionuclide, the chemical form, and solubility. In addition, biological parameters such as breathing rate, breathing type (nasal or nasal/oral), respiratory system morphometry, tidal volume, functional residual capacity, and anatomical dead space all influence material transport. These aerosol properties and physiological characteristics of the respiratory tract jointly define a range of initial conditions that influence the time-dependent distribution of radioactive material. To evaluate both uncertainty in the initial conditions of inhalation exposure and the final output (committed effective dose) from biokinetic models, a Python-based software tool, Radiological Exposure Dose Calculator (REDCAL), was developed to propagate uncertainty within the human respiratory tract model. Focusing on deposition fraction uncertainty, the primary objective was to characterize the initial activity distribution across respiratory regions as a function of anticipated particle sizes and distributions. The impact of the deposition fraction uncertainty was propagated to committed effective dose coefficients for selected radionuclides in a companion publication. For each particle size, a lognormal distribution, characterized by its geometric mean as defined within ICRP Publication 66, serves as the basis for introducing uncertainty into the physical processes governing deposition in various lung regions. Finally, this study addresses the deposition process and examines how uncertainty in deposition mechanisms affects activity distribution in the airways, ultimately presenting the expected range and standard deviation of deposited activity as a function of particle size.

International Commission on Radiological Protectio↗

MO-FG-BRA-05: Dosimetric and Radiobiological Validation of Respiratory Gating in Conventional and Hypofractionated Radiotherapy of the Lung: Effect of Dose, Dose Rate, Gating Window and Breathing Pattern

Purpose: to evaluate the dosimetric and radiobiological consequences from having different gating windows, dose rates, and breathing patterns in gated VMAT lung radiotherapy. Methods: A novel 3D-printed moving phantom with central high and peripheral low tracer uptake regions was 4D FDG-PET/CT-scanned using ideal, patient-specific regular, and irregular breathing patterns. A scan of the stationary phantom was obtained as a reference. Target volumes corresponding to different uptake regions were delineated. Simultaneous integrated boost (SIB) 6 MV VMAT plans were produced for conventional and hypofractionated radiotherapy, using 30–70 and 100% cycle gating scenarios. Prescribed doses were 200 cGy with SIB to 240 cGy to high uptake volume for conventional, and 800 with SIB to 900 cGy for hypofractionated plans. Dose rates of 600 MU/min (conventional and hypofractionated) and flattening filter free 1400 MU/min (hypofractionated) were used. Ion chamber measurements were performed to verify delivered doses. Vials with A549 cells placed in locations matching ion chamber measurements were irradiated using the same plans to measure clonogenic survival. Differences in survival for the different doses, dose rates, gating windows, and breathing patterns were analyzed. Results: Ion chamber measurements agreed within 3% of the planned dose, for all locations, breathing patterns and gating windows. Cell survival depended on dose alone, and not on gating window, breathing pattern, MU rate, or delivery time. The surviving fraction varied from approximately 40% at 2Gy to 1% for 9 Gy and was within statistical uncertainty relative to that observed for the stationary phantom. Conclusions: Use of gated VMAT in PET-driven SIB radiotherapy was validated using ion chamber measurements and cell survival assays for conventional and hypofractionated radiotherapy.

60 APPLIED LIFE SCIENCES↗

Respiratory analysis system and method

A system is described for monitoring the respiratory process in which the gas flow rate and the frequency of respiration and expiration cycles can be determined on a real time basis. A face mask is provided with one-way inlet and outlet valves where the gas flow is through independent flowmeters and through a mass spectrometer. The opening and closing of a valve operates an electrical switch, and the combination of the two switches produces a low frequency electrical signal of the respiratory inhalation and exhalation cycles. During the time a switch is operated, the corresponsing flowmeter produces electric pulses representative of the flow rate; the electrical pulses being at a higher frequency than that of the breathing cycle and combined with the low frequency signal. The high frequency pulses are supplied to conventional analyzer computer which also receives temperature and pressure inputs and computes mass flow rate and totalized mass flow of gas. From the mass spectrometer, components of the gas are separately computed as to flow rate. The electrical switches cause operation of up-down inputs of a reversible counter. The respective up and down cycles can be individually monitored and combined for various respiratory measurements.

Liu, F. F.↗

Effectiveness of external respiratory surrogates for in vivo liver motion estimation

Purpose: Due to low frame rate of MRI and high radiation damage from fluoroscopy and CT, liver motion estimation using external respiratory surrogate signals seems to be a better approach to track liver motion in real-time for liver tumor treatments in radiotherapy and thermotherapy. This work proposes a liver motion estimation method based on external respiratory surrogate signals. Animal experiments are also conducted to investigate related issues, such as the sensor arrangement, multisensor fusion, and the effective time period. Methods: Liver motion and abdominal motion are both induced by respiration and are proved to be highly correlated. Contrary to the difficult direct measurement of the liver motion, the abdominal motion can be easily accessed. Based on this idea, our study is split into the model-fitting stage and the motion estimation stage. In the first stage, the correlation between the surrogates and the liver motion is studied and established via linear regression method. In the second stage, the liver motion is estimated by the surrogate signals with the correlation model. Animal experiments on cases of single surrogate signal, multisurrogate signals, and long-term surrogate signals are conducted and discussed to verify the practical use of this approach. Results: The results show that the best single sensor location is at the middle of the upper abdomen, while multisurrogate models are generally better than the single ones. The estimation error is reduced from 0.6 mm for the single surrogate models to 0.4 mm for the multisurrogate models. The long-term validity of the estimation models is quite satisfactory within the period of 10 min with the estimation error less than 1.4 mm. Conclusions: External respiratory surrogate signals from the abdomen motion produces good performance for liver motion estimation in real-time. Multisurrogate signals enhance estimation accuracy, and the estimation model can maintain its accuracy for at least 10 min. This approach can be used in practical applications such as the liver tumor treatment in radiotherapy and thermotherapy.

60 APPLIED LIFE SCIENCES↗

Hantavirus is Associated With Open Developed Areas and Arid Climates, Highlighting Increased Risk in the Western United States

In the United States, hantaviruses can cause hantavirus pulmonary syndrome (HPS) in humans, an acute respiratory illness with a high mortality rate. Most people contract HPS from exposure to infected rodent excrement. The interannual dynamics of hantavirus transmission are tied to both environmental and human-related factors, including changes in annual climate conditions, rodent populations, and the built environment in which humans are more likely to be exposed. Similar environmental conditions and socioeconomic factors also likely determine the long-term risk of hantavirus exposure. Here, we use ecological niche models and human cases of HPS in the U.S. from 1993 to 2022 to assess hantavirus risk using four socioeconomic variables, 17 land use variables, one variable of rodent richness, and seven climate variables to determine both the geographical locations of highest exposure risk and leading environmental predictors. We found that areas with higher relative risk tend to be where it is drier, higher social vulnerability, increased rodent richness, and more open to low levels of development—this largely mapped to the western U.S. We found evidence that fringe ecosystems may be important areas of hantavirus transmission, similar to other emerging diseases. Increased rodent richness was associated with increased hantavirus risk, warranting further investigation into how the abundance and community composition of rodents could impact long-term risk. These risk maps can help public health officials develop plans for mitigating hantavirus, especially for the most susceptible populations. They can also be used to further investigate regions estimated to be at high risk for hantavirus where disease cases have not been as common but may be underreported.

54 ENVIRONMENTAL SCIENCES↗

Cardiorespiratory responses to exercise in air and underwater.

Respiratory gas exchange, end-tidal gas tensions, alveolar ventilation, respiratory frequency, cardiac output, and pulse rate were measured in four healthy adult males at rest and during mild and moderate exercise in air at 18-22 C and underwater at 35.0-35.5 C. Immersion was associated with a 10% increase in pulse rate and cardiac output at all levels of exercise. There were no changes in end-tidal CO2 tension or alveolar ventilation. It is concluded that horizontal subjects breathing at eupneic pressures and working against mild and moderate loads in warm water show the same responses to exercise as in air.-

Denison, D. M.↗

Physiological response to exercise after space flight - Apollo 14 through Apollo 17

Submaximal exercise stress tests were conducted preflight and postflight on the Apollo 14-17 crewmen. A bicycle ergometer was utilized to evoke target heart rates up to 160 beats/min while respiratory gas exchange, blood pressure, and cardiac output were measured. Three preflight tests were conducted during the month prior to flight to establish baseline values for postflight comparisons. Tachycardia was evidenced at rest and during exercise immediately postflight. This transitory tachycardia compensated for reduced stroke volume. Systolic blood pressure was reduced during exercise stress, but no consistent changes were observed in diastolic blood pressure. With the exception of the Apollo 15 crewmen, all crewmen had returned to preflight response levels by the day following recovery. No changes were observed in mechanical or respiratory efficiency immediately postflight.

Rummel, J. A.↗

Cardiopulmonary data acquisition system. Version 2.0, volume 1: User's guide

The Cardiopulmonary Data Acquisition System is a computerized method of both collecting and analyzing physiological data on subjects during a treadmill or ergometer stress test in the clinic. The real time acquisition of the physiological data, such as, heart rate, blood pressure, work load, and respiratory gases is accomplished by an LSI-11 microcomputer which displays this data on a hard copy terminal. The data are also concurrently stored on a mass storage device and anytime after the test period a selectable number of copies of the plots or minute reports can be reproduced at the terminal.

Source record↗

Stem respiration and growth in a central Amazon rainforest

Tropical forests cycle a large amount of CO 2 between the land and atmosphere, with a substantial portion of the return flux due tree respiratory processes. However, in situ estimates of woody tissue respiratory fluxes and carbon use efficiencies (CUEW) and their dependencies on physiological processes including stem wood production (Pw) and transpiration in tropical forests remain scarce. In this work, we synthesize monthly Pw and daytime stem CO 2 efflux (ES) measurements over one year from 80 trees with variable biomass accumulation rates in the central Amazon. On average, carbon flux to woody tissues, expressed in the same stem area normalized units as ES, averaged 0.90 ± 1.2 µmol m -2 s -1 for Pw, and 0.55 ± 0.33 µmol m -2 s -1 for daytime ES. A positive linear correlation was found between stem growth rates and stem CO 2 efflux, with respiratory carbon loss equivalent to 15 ± 3% of stem carbon accrual. CUEW of stems was non-linearly correlated with growth and was as high as 77-87% for a fast-growing tree. Diurnal measurements of stem CO 2 efflux for three individuals showed a daytime reduction of ES by 15-50% during periods of high sap flow and transpiration. The results demonstrate that high daytime ES fluxes are associated with high CUE W during fast tree growth, reaching higher values than previously observed in the Amazon Basin (e.g. maximum CUEW up to 77-87%, versus 30-56%). The observations are consistent with the emerging view that diurnal dynamics of stem water status influences growth processes and associated respiratory metabolism.

54 ENVIRONMENTAL SCIENCES↗

Cardiac and Vascular Function in Bedrested Volunteers: Effects of Artificial Gravity Training

Cardiovascular effects of an artificial gravity (AG) countermeasure on deconditioned male volunteers were studied. In two groups of men we measured cardiovascular parameters at rest and in response to 30 minutes of 80 deg. head up tilt (HUT) before, at the end of, and four days following 21 days of 6 deg. head down bed rest (HDBR). One group (N=7) underwent no countermeasure while the other (N=8) received a daily, one hour, dose (2.5 gz at the foot, decreasing to 1.0 gz at the heart) of AG training on the Johnson Space Center short radius centrifuge. Cardiovascular parameters measured included heart rate, blood pressure, stroke volume, cardiac output, peripheral vascular resistance, plasma volume shifts, and vasoactive hormones. Untrained subjects exhibited shorter tilt survival (on average 8 minutes shorter) compared to trained subjects. By the end of bed rest, mean heart rate (MHR) was elevated in both groups (both supine and during tilt). In addition, treated subjects demonstrated lower, tilt-induced, increases in MHR four days following HDBR, indicating a more rapid return to pre bed rest conditions. Results from an index of autonomic balance (percentage of MHR spectral power in the respiratory frequency range) in control of heart rate are consistent with the interpretation that parasympathetic nervous system withdrawal was responsible for both tilt- and bed rest-induced increases in MHR. Our data support our pre-study hypothesis that AG treatment would lessen cardiovascular effects of deconditioning in bed rested men and suggest that AG should be further pursued as a space flight countermeasure.

Meng, M.↗

A method to synchronize signals from multiple patient monitoring devices through a single input channel for inclusion in list-mode acquisitions

Purpose: This technical note documents a method that the authors developed for combining a signal to synchronize a patient-monitoring device with a second physiological signal for inclusion into list-mode acquisition. Our specific application requires synchronizing an external patient motion-tracking system with a medical imaging system by multiplexing the tracking input with the ECG input. The authors believe that their methodology can be adapted for use in a variety of medical imaging modalities including single photon emission computed tomography (SPECT) and positron emission tomography (PET). Methods: The authors insert a unique pulse sequence into a single physiological input channel. This sequence is then recorded in the list-mode acquisition along with the R-wave pulse used for ECG gating. The specific form of our pulse sequence allows for recognition of the time point being synchronized even when portions of the pulse sequence are lost due to collisions with R-wave pulses. This was achieved by altering our software used in binning the list-mode data to recognize even a portion of our pulse sequence. Limitations on heart rates at which our pulse sequence could be reliably detected were investigated by simulating the mixing of the two signals as a function of heart rate and time point during the cardiac cycle at which our pulse sequence is mixed with the cardiac signal. Results: The authors have successfully achieved accurate temporal synchronization of our motion-tracking system with acquisition of SPECT projections used in 17 recent clinical research cases. In our simulation analysis the authors determined that synchronization to enable compensation for body and respiratory motion could be achieved for heart rates up to 125 beats-per-minute (bpm). Conclusions: Synchronization of list-mode acquisition with external patient monitoring devices such as those employed in motion-tracking can reliably be achieved using a simple method that can be implemented using minimal external hardware and software modification through a single input channel, while still recording cardiac gating signals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatial variation in microbial processes controlling carbon mineralization within soils and sediments

Soils have a defining role in global carbon cycling, having one of the largest dynamic stocks of C on earth—3300 Pg of C are stored in soils, which is three-times the amount stored in the atmosphere and more than the terrestrial land plants. An important control on soil organic matter (SOM) quantities is the mineralization rate. It is well recognized that the rate and extent of SOM mineralization is affected by climatic factors and mineral-organic matter associations. What remained elusive is to what extent constraints on microbial metabolism induced by the respiratory pathway, and specifically the electron acceptor in respiration, control overall rates of carbon mineralization in soils. Therefore, physical factors limiting oxygen diffusion such as soil texture and aggregate size (soil structure) may therefore be central controls on C mineralization rates. The goal of our research was therefore to determine if variations in microbial metabolic rates induced by anaerobic microsites in soils are a major control on SOM mineralization rates and thus storage. We performed a combination of laboratory experiments and field investigations will be performed to fulfill our research objectives. We used laboratory studies to examine fundamental factors of respiratory constraints (i.e., electron acceptor) on organic matter mineralization rates. We ground our laboratory studies with both manipulation of field samples and in-field measurements. Selection of the field sites is guided by variation in soil texture and structure while having (other environmental/soil factors constant. Our laboratory studies defined redox gradients and variations in microbial metabolism operating at the aggregate-scale (cm-scale) within soils using a novel constructed diffusion reactor. We further examined micro-scale variation in terminal electron accepting processes and resulting C mineralization rates within re-packed soils. A major outcome of our research is the ability to quantitatively place the importance of aggregate-based heterogeneity in microbial redox processes and the resulting lack of oxygen on the rate of carbon mineralization. Collectively, our research shows that anaerobic microsites are prevalent in soils and are important regulators of soil carbon persistence, shifting microbial metabolism to less efficient anaerobic respiration and selectively protecting otherwise bioavailable, reduced organic compounds such as lipids and waxes from decomposition. Further, shifting from anaerobic to aerobic conditions leads to a 10-fold increase in volume-specific mineralization rate, illustrating the sensitivity of anaerobically protected carbon to disturbance. Vulnerability of anaerobically protected carbon to future climate or land use change thus constitutes a yet unrecognized soil carbon-climate feedback that should be incorporated into terrestrial ecosystem models.

54 ENVIRONMENTAL SCIENCES↗

Mitochondrial-targeted aryl hydrocarbon receptor and the impact of 2,3,7,8-tetrachlorodibenzo-p-dioxin on cellular respiration and the mitochondrial proteome

The aryl hydrocarbon receptor (AHR) is a ligand-activated transcription factor within the Per-Arnt-Sim (PAS) domain superfamily. Exposure to the most potent AHR ligand, 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), is associated with various pathological effects including metabolic syndrome. While research over the last several years has demonstrated a role for oxidative stress and metabolic dysfunction in AHR-dependent TCDD-induced toxicity, the role of the mitochondria in this process has not been fully explored. Our previous research suggested that a portion of the cellular pool of AHR could be found in the mitochondria (mitoAHR). Using a protease protection assay with digitonin extraction, we have now shown that this mitoAHR is localized to the inter-membrane space (IMS) of the organelle. TCDD exposure induced a degradation of mitoAHR similar to that of cytosolic AHR. Furthermore, siRNA-mediated knockdown revealed that translocase of outer-mitochondrial membrane 20 (TOMM20) was involved in the import of AHR into the mitochondria. In addition, TCDD altered cellular respiration in an AHR-dependent manner to maintain respiratory efficiency as measured by oxygen consumption rate (OCR). Stable isotope labeling by amino acids in cell culture (SILAC) identified a battery of proteins within the mitochondrial proteome influenced by TCDD in an AHR-dependent manner. Among these, 17 proteins with fold changes ≥ 2 are associated with various metabolic pathways, suggesting a role of mitochondrial retrograde signaling in TCDD-mediated pathologies. Collectively, these studies suggest that mitoAHR is localized to the IMS and AHR-dependent TCDD-induced toxicity, including metabolic dysfunction, wasting syndrome, and hepatic steatosis, involves mitochondrial dysfunction. - Highlights: • The mitoAHR is localized in the mitochondrial intermembrane space. • TOMM20 participates in mitoAHR translocation. • AHR contributes to the maintenance of respiratory control ratio following TCDD exposure. • TCDD-induced AHR-dependent changes in the mitochondrial proteome are identified.

60 APPLIED LIFE SCIENCES↗

Escape from neutralization by the respiratory syncytial virus-specific neutralizing monoclonal antibody palivizumab is driven by changes in on-rate of binding to the fusion protein

The role of binding kinetics in determining neutralizing potency for antiviral antibodies is poorly understood. While it is believed that increased steady-state affinity correlates positively with increased virus-neutralizing activity, the relationship between association or dissociation rate and neutralization potency is unclear. We investigated the effect of naturally-occurring antibody resistance mutations in the RSV F protein on the kinetics of binding to palivizumab. Escape from palivizumab-mediated neutralization of RSV occurred with reduced association rate (K{sub on}) for binding to RSV F protein, while alteration of dissociation rate (K{sub off}) did not significantly affect neutralizing activity. Interestingly, linkage of reduced K{sub on} with reduced potency mirrored the effect of increased K{sub on} found in a high-affinity enhanced potency palivizumab variant (motavizumab). These data suggest that association rate is the dominant factor driving neutralization potency for antibodies to RSV F protein antigenic site A and determines the potency of antibody somatic variants or efficiency of escape of viral glycoprotein variants. - Highlights: • The relationship of affinity to neutralization for virus antibodies is uncertain. • Palivizumab binds to RSV escape mutant fusion proteins, but with reduced affinity. • Association rate (K{sub on}) correlated well with the potency of neutralization.

60 APPLIED LIFE SCIENCES↗

Occupational safety considerations with hydrazine fuels

A simple pharmacokinetic model and a specially designed dermal vapor exposure chamber which provides respiratory protection were used to determine the rate of penetration of hydrazine and 1,1-dimethylhydrazine (UDMH) vapor through the skin of rats. Parameters for the pharmacokinetic model were determined from intravenous and inhalation exposure data. The model was then used to estimate the skin permeation coefficient for hydrazine or UDMH vapor from the dermal-vapor exposure data. This analysis indicates that UDMH vapor has a relatively high permeability through skin (0.7 cm/hr), a value somewhat higher than was obtained for hydrazine by the same procedure (0.09 cm/hr). Based on these skin permeability results, a skin-only vapor exposure limit giving protection equivalent to the inhalation Threshold Limit Value (TLV) could be calculated. The current TLV's for UDMH and hydrazine are 0.5 and 0.1 ppm, respectively. The corresponding skin-only TLV equivalents, for personnel wearing respiratory protection, are 32 ppm for UDMH and 48 ppm for hydrazine. Should the proposed lowering to the TLV's for these compounds to 0.01 ppm be adopted, the equivalent skin-only TLV's would become 0.64 ppm for UDMH and 4.8 for hydrazine.

Clewell, H. J.↗

In situ spectroscopy on intact Leptospirillum ferrooxidans reveals that reduced cytochrome 579 is an obligatory intermediate in the aerobic iron respiratory chain

Electron transfer reactions among colored cytochromes in intact bacterial cells were monitored using an integrating cavity absorption meter that permitted the acquisition of accurate absorbance data in suspensions of cells that scatter light.The aerobic iron respiratory chain of Leptospirillum ferrooxidans was dominated by the redox status of an abundant cellular cytochrome that had an absorbance peak at 579 nm in the reduced state. Intracellular cytochrome 579 was reduced within the time that it took to mix a suspension of the bacteria with soluble ferrous iron at pH 1.7. Steady state turnover experiments were conducted where the initial concentrations of ferrous iron were less than or equal to that of the oxygen concentration. Under these conditions, the initial absorbance spectrum of the bacterium observed under air-oxidized conditions was always regenerated from that of the bacterium observed in the presence of Fe(II). The kinetics of aerobic respiration on soluble iron by intact L. ferrooxidans conformed to the Michaelis–Menten formalism, where the reduced intracellular cytochrome 579 represented the Michaelis complex whose subsequent oxidation appeared to be the rate-limiting step in the overall aerobic respiratory process. The velocity of formation of ferric iron at any time point was directly proportional to the concentration of the reduced cytochrome 579. Further, the integral over time of the concentration of the reduced cytochrome was directly proportional to the total concentration of ferrous iron in each reaction mixture.These kinetic data obtained using whole cells were consistent with the hypothesis that reduced cytochrome 579 is an obligatory steady state intermediate in the iron respiratory chain of this bacterium. The capability of conducting visible spectroscopy in suspensions of intact cells comprises a powerful post-reductionist means to study cellular respiration in situ under physiological conditions for the organism.

59 BASIC BIOLOGICAL SCIENCES↗

Emergency department visits in California associated with wildfire PM 2.5 : differing risk across individuals and communities

The threats to human health from wildfires and wildfire smoke (WFS) in the United States (US) are increasing due to continued climate change. A growing body of literature has documented important adverse health effects of WFS exposure, but there is insufficient evidence regarding how risk related to WFS exposure varies across individual or community level characteristics. To address this evidence gap, we utilized a large nationwide database of healthcare utilization claims for emergency department (ED) visits in California across multiple wildfire seasons (May through November, 2012–2019) and quantified the health impacts of fine particulate matter <2.5 μm (PM 2.5 ) air pollution attributable to WFS, overall and among subgroups of the population. We aggregated daily counts of ED visits to the level of the Zip Code Tabulation Area (ZCTA) and used a time-stratified case-crossover design and distributed lag non-linear models to estimate the association between WFS and relative risk of ED visits. We further assessed how the association with WFS varied across subgroups defined by age, race, social vulnerability, and residential air conditioning (AC) prevalence. Over a 7 day period, PM 2.5 from WFS was associated with elevated risk of ED visits for all causes (1.04% (0.32%, 1.71%)), non-accidental causes (2.93% (2.16%, 3.70%)), and respiratory disease (15.17% (12.86%, 17.52%)), but not with ED visits for cardiovascular diseases (1.06% (–1.88%, 4.08%)). Analysis across subgroups revealed potential differences in susceptibility by age, race, and AC prevalence, but not across subgroups defined by ZCTA-level Social Vulnerability Index scores. These results suggest that PM 2.5 from WFS is associated with higher rates of all cause, non-accidental, and respiratory ED visits with important heterogeneity across certain subgroups. Notably, lower availability of residential AC was associated with higher health risks related to wildfire activity.

54 ENVIRONMENTAL SCIENCES↗