Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RELAXATION TIME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Quarkonia and heavy-quark relaxation times in the quark-gluon plasma

A thermodynamic T-matrix approach for elastic two-body interactions is employed to calculate spectral functions of open and hidden heavy-quark systems in the quark-gluon plasma. This enables the evaluation of quarkonium bound-state properties and heavy-quark diffusion on a common basis and thus to obtain mutual constraints. The two-body interaction kernel is approximated within a potential picture for spacelike momentum transfers. An effective field-theoretical model combining color-Coulomb and confining terms is implemented with relativistic corrections and for different color channels. Four pertinent model parameters, characterizing the coupling strengths and screening, are adjusted to reproduce the color-average heavy-quark free energy as computed in thermal lattice QCD. The approach is tested against vacuum spectroscopy in the open (D, B) and hidden ({Psi} and {Upsilon}) flavor sectors, as well as in the high-energy limit of elastic perturbative QCD scattering. Theoretical uncertainties in the static reduction scheme of the four-dimensional Bethe-Salpeter equation are elucidated. The quarkonium spectral functions are used to calculate Euclidean correlators which are discussed in light of lattice QCD results, while heavy-quark relaxation rates and diffusion coefficients are extracted utilizing a Fokker-Planck equation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effects of spin-lock field direction on the quantitative measurement of spin-lattice relaxation time constant in the rotating frame (T1ρ) in a clinical MRI system

Purpose: To investigate whether the direction of spin-lock field, either parallel or antiparallel to the rotating magnetization, has any effect on the spin-lock MRI signal and further on the quantitative measurement of T1ρ, in a clinical 3 T MRI system. Methods: The effects of inverted spin-lock field direction were investigated by acquiring a series of spin-lock MRI signals for an American College of Radiology MRI phantom, while the spin-lock field direction was switched between the parallel and antiparallel directions. The acquisition was performed for different spin-locking methods (i.e., for the single- and dual-field spin-locking methods) and for different levels of clinically feasible spin-lock field strength, ranging from 100 to 500 Hz, while the spin-lock duration was varied in the range from 0 to 100 ms. Results: When the spin-lock field was inverted into the antiparallel direction, the rate of MRI signal decay was altered and the T1ρ value, when compared to the value for the parallel field, was clearly different. Different degrees of such direction-dependency were observed for different spin-lock field strengths. In addition, the dependency was much smaller when the parallel and the antiparallel fields are mixed together in the dual-field method. Conclusions: The spin-lock field direction could impact the MRI signal and further the T1ρ measurement in a clinical MRI system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correction of Q Factor Effects for Simultaneous Collection of Elemental Analysis and Relaxation Times by Nuclear Magnetic Resonance

A new method for measurement of elemental analysis by nuclear magnetic resonance (NMR) of unknown samples is discussed in this report as a quick and robust means to measure elemental ratios without the use of internal or external calibration standards. The determination of elemental ratios was done by normalizing the signal intensities by the frequency dependent quality factor (Q) and the gyromagnetic ratios (γ) for each measured nucleus. The correction for the frequency dependence was found by characterizing the output signal of the probe as a function of the quality factor (Q) and the frequency, and the correction for γ was discussed in a previous study. A Carr–Purcell–Meiboom–Gill (CPMG) pulse sequence was used for evaluation of the relative signal intensities, which allows for derivation of elemental ratios, and was correspondingly used to simultaneously measure the T 2 * of samples for an added parameter for more accurate identification of unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anomalously Large Seebeck Coefficient of CuFeS 2 Derives from Large Asymmetry in the Energy Dependence of Carrier Relaxation Time

The Seebeck effect in a material originates from the distribution of asymmetry in the electron transport under a temperature gradient, which has contributions from the energy-dependent electronic density-of-states and carrier mobility. However, because the energy dependence of common electron scattering mechanisms is weak, the mobility-driven Seebeck coefficient has long been ignored in most thermoelectric materials, and the energy asymmetry of the density-of-states has been considered the dominant contribution. In this work, we describe a hopping transport behavior observed in CuFeS 2 , and a large carrier Hall mobility gradient of dμH/dT that creates an unusually large energy-dependent mobility contribution to the Seebeck coefficient. This work offers several ideas regarding the mobility-driven Seebeck effect and its potential utilization in the design of thermoelectric materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of approximate solutions to the phonon Boltzmann transport equation with the relaxation time approximation: Spherical harmonics expansions and the discrete ordinates method

In this study, the phonon Boltzmann transport equation is used to analyze model problems in one and two spatial dimensions, under transient and steady-state conditions. New, explicit solutions are obtained by using the P 1 and P 3 approximations, based on expansions in spherical harmonics, and are compared with solutions from the discrete ordinates method. For steady-state energy transfer, it is shown that analytic expressions derived using the P 1 and P 3 approximations agree quantitatively with the discrete ordinates method, in some cases for large Knudsen numbers, and always for Knudsen numbers less than unity. However, for time-dependent energy transfer, the P N solutions differ qualitatively from converged solutions obtained by the discrete ordinates method. Although they correctly capture the wave-like behavior of energy transfer at short times, the P 1 and P 3 approximations rely on one or two wave velocities, respectively, yielding abrupt, step-changes in temperature profiles that are absent when the angular dependence of the phonon velocities is captured more completely. It is shown that, with the gray approximation, the P 1 approximation is formally equivalent to the so-called “hyperbolic heat equation.” In conclusion, these results support the use of the P N approximation to find solutions to the phonon Boltzmann transport equation for steady-state conditions. Such solutions can be useful in the design and analysis of devices that involve heat transfer at nanometer length scales, where continuum-scale approaches become inaccurate.

36 MATERIALS SCIENCE↗

Relaxation time for strange quark spin in rotating quark-gluon plasma

Experiments at the Relativistic Heavy Ion Collider have measured the net polarization of $\Lambda$ and $\bar{Λ }$ hyperons and attributed it to a coupling between their spin and the vorticity of the fluid created in heavy-ion collisions. Equipartition of energy is generally assumed, but the dynamical mechanism which polarizes them has yet to be determined. We consider two such mechanisms: vorticity fluctuations and helicity flip in scatterings between strange quarks and light quarks and gluons. With reasonable parameters both mechanisms lead to equilibration times orders of magnitude too large to be relevant to heavy-ion collisions. In this work our conclusion is that strange quark spin or helicity is unchanged from the time they are created to the time they hadronize. A corollary is that vorticity fluctuations do not affect the hyperon spin, either.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Relaxation times for disoriented isospin condensates in high energy heavy ion collisions

Fluctuations between charged and neutral kaons measured by the ALICE Collaboration in Pb-Pb collisions at the CERN Large Hadron Collider (LHC) exceed conventional explanations. Previously it was shown that if the scalar condensate is accompanied by an electrically neutral isospin-1 field then the combination can produce large equilibrium fluctuations where ⟨$\overline{𝑢}$ ⁢𝑢⟩≠⟨ $\overline{𝑑}$𝑑⟩. Hadronizing strange and antistrange quarks might then strongly fluctuate between charged ($\overline{𝑢}$⁢𝑠 or $\overline{𝑠}$⁢𝑢) and neutral (𝑑⁢$\overline{𝑠}$⁢ or 𝑠⁢$\overline{𝑑}$) kaons. Here, we estimate the times for the condensates to achieve their equilibrium probability distributions within causal volumes in high energy heavy ion collisions. This is achieved by modeling the temperature dependence of the condensates, mesonic collective excitations, decay rates of the associated fields, and employing the Langevin and Fokker-Planck equations. Within this model, we find that the equilibration times are short compared with the expansion time, making disoriented isospin condensates a viable explanation for the anomalous fluctuations observed at the LHC.

Quark-gluon plasma↗

Long-time relaxation processes in the nonlinear Schroedinger equation

The nonlinear Schroedinger equation, known in low-temperature physics as the Gross-Pitaevskii equation, has a large family of excitations of different kinds. They include sound excitations, vortices, and solitons. The dynamics of vortices strictly depends on the separation between them. For large separations, some kind of adiabatic approximation can be used. We consider the case where an adiabatic approximation can be used (large separation between vortices) and the opposite case of a decay of the initial state, which is close to the double vortex solution. In the last problem, no adiabatic parameter exists (the interaction is strong). Nevertheless, a small numerical parameter arises in the problem of the decay rate, connected with an existence of a large centrifugal potential, which leads to a small value of the increment. The properties of the nonlinear wave equation are briefly considered in the Appendix A.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effective masses, relaxation times, and carrier mobilities in some chloride intercalants of graphite

The effective masses, carrier scattering times and carrier mobilities have been measured in selected graphite intercalation compounds using the Shubnikov-de Haas effect at a series of temperatures between 4 and 50 K. Effective masses are less than or equal to 0.1 of the free-electron mass, scattering times are about 10 to the -13th/s and carrier mobilities are on the order of 10,000 sq cm/V s.

Woollam, J. A.↗