Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFLECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Step-Stress Accelerated Degradation Testing for Solar Reflectors: Preprint

To meet the challenge to reduce the cost of electricity generated with concentrating solar power (CSP) new low-cost reflector materials are being developed including metalized polymer reflectors and must be tested and validated against appropriate failure mechanisms. We explore the application of testing methods and statistical inference techniques for quantifying estimates and improvinglifetimes of concentrating solar power (CSP) reflectors associated with failure mechanisms initiated by exposure to the ultraviolet (UV) part of the solar spectrum. In general, a suite of durability and reliability tests are available for testing a variety of failure mechanisms where the results of a set are required to understand overall lifetime of a CSP reflector. We will focus on the use ofthe Ultra-Accelerated Weathering System (UAWS) as a testing device for assessing various degradation patterns attributable to accelerated UV exposure. Depending on number of samples, test conditions, degradation and failure patterns, test results may be used to derive insight into failure mechanisms, associated physical parameters, lifetimes and uncertainties. In the most complicated casewarranting advanced planning and statistical inference, step-stress accelerated degradation (SSADT) methods may be applied.

14 SOLAR ENERGY↗

A dual-resonant reflector in powerful relativistic backward wave oscillator

A dual-resonant reflector is proposed to suppress the radio frequency breakdown and enhance the reflection in a high power relativistic backward wave oscillator. The backward wave is reflected by two reflector cavities step by step, therefore, a high reflectivity is obtained. A preliminary high power microwave generation experiment of backward wave oscillator (BWO) with a general resonant reflector and a dual-resonant reflector was carried out. A microwave with power over 3 GW, frequency 9.6 GHz, efficiency 30%, and pulse width 22 ns was generated. The experiment results show that the efficiency of BWO with a dual-RR is enhanced about 2%-6%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam splitting target reflector based compensation for angular drift of laser beam in laser autocollimation of measuring small angle deviations

Beam splitting target reflector based compensation for the angular drift of laser beam in laser autocollimation is proposed in this article to improve the measurement accuracy and stability of small angle deviations. A beam splitting target reflector is used to replace the plane mirror in laser autocollimation to generate a reference beam when returning the measurement beam. The reference beam and measurement beam have the same angular drift, but have different sensitivities to the rotation angle of the reflector due to the unique characteristics of the reflector. Thus, the angular drift of laser beam in laser autocollimation can be compensated in real time by using the drift of reference beam. Experimental results indicate that an output stability of 0.085 arc sec in 2 h can be achieved after compensation. And a measurement accuracy of {+-}0.032 arc sec can be obtained over the range of {+-}1190 arc sec with an effective resolution of 0.006 arc sec. It is confirmed that the compensation method for the angular drift of laser beam is necessary for improving the measurement accuracy and stability in laser autocollimation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced quantum efficiency of amorphous silicon thin film solar cells with the inclusion of a rear-reflector thin film

We investigated the growth mechanism of amorphous silicon thin films by implementing hot-wire chemical vapor deposition and fabricated thin film solar cell devices. The fabricated cells showed efficiencies of 7.5 and 8.6% for the samples without and with the rear-reflector decomposed by sputtering, respectively. The rear-reflector enhances the quantum efficiency in the infrared spectral region from 550 to 750 nm. The more stable quantum efficiency of the sample with the inclusion of a rear-reflector than the sample without the rear-reflector due to the bias effect is related to the enhancement of the short circuit current.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An improved suppression method of the transverse-electromagnetic mode leakage with two reflectors in the triaxial klystron amplifier

Suppression of the transverse-electromagnetic (TEM) mode leakage is crucial in the design of a triaxial klystron amplifier with high gain, because a small microwave leakage from the buncher or the output cavity could overwhelm the input signal with low power. In this paper, a specially designed reflector is proposed to suppress the TEM mode leakage, whose axial electric field is approximately zero at the beam radial position. Theoretical analysis indicates that the reflector introduces little influence on the normal modulation of the beam while keeping a high reflection coefficient. By using two such reflectors with different eigen frequencies located in front of the buncher cavity and the output cavity, respectively, an improved triaxial klystron amplifier is presented. The simulation results show that the reflectors substantially decrease the TEM mode leakage power and achieve very good isolation among the cavities. The improved triaxial klystron amplifier can operate normally with 10's kW microwave injection without self-oscillations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Focusing electrode and coaxial reflector used for reducing the guiding magnetic field of the Ku-band foilless transit-time oscillator

Based on the theoretical analysis of the intense relativistic electron beam propagation in the coaxial drift-tube, a focusing electrode and a coaxial reflector is proposed to lessen the demand of the coaxial Ku-band foilless transit-time oscillator (TTO) for the guiding magnetic field. Moreover, a Ku-band TTO with the focusing electrode and the coaxial reflector is designed and studied by particle in cell simulation. When the diode voltage is 390 kV, the beam current 7.8 kA, and the guiding magnetic field is only 0.3 T, the device can output 820 MW microwave pulse at 14.25 GHz by means of the simulation. However, for the device without them, the output power is only 320 MW. The primary experiments are also carried out. When the guiding magnetic field is 0.3 T, the output power of the device with the focusing electrode and the coaxial reflector is double that of the one without them. The simulation and experimental results prove that the focusing electrode and the coaxial reflector are effective on reducing the guiding magnetic field of the device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary research on overmoded high-power millimeter-wave Cerenkov generator with dual-cavity reflector in low guiding magnetic field

This paper presents preliminary research on a V-band overmoded Cerenkov generator with dual-cavity reflector operating in a low guiding magnetic field. It is found that the fluctuation of the electron envelope in the low guiding magnetic field can be predicted using an equivalent coaxial model of a foilless diode, and a dual-cavity reflector based on the model matching method can provide strong reflection at the front end of the overmoded structures so that any microwave power that leaks into the diode region can be effectively suppressed. Numerical simulations indicate that the control of the beam envelope and the use of the dual-cavity reflector ease generator operation in the low guiding magnetic field. In the experimental research, the fluctuation of the annular electron beam with the outer radius of 7.5 mm measures approximately 0.7 mm, which is in good agreement with the theoretical results. The disturbance caused by power leaking from the overmoded slow wave structure is eliminated by the dual-cavity reflector. With accurate fabrication and assembly processes, an operating frequency of 61.6 GHz is attained by the fifth harmonic heterodyne method, and the output power is measured to be approximately 123 MW by the far-field measurement method at a diode voltage of 445 kV, a beam current of 4.45 kA, and under a guiding magnetic field of 1.45 T. The output mode is measured using an array of neon flash bulbs, and the pulse shortening phenomenon is both observed and analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance characterization of x-ray crystal spectroscopy highly oriented pyrolytic graphite reflectors based on x-ray diffractometry experiments

The use of Highly Oriented Pyrolytic Graphite (HOPG) reflectors is often proposed in the design of X-ray Crystal Spectroscopy (XCS) diagnostic systems for the next-generation tokamak devices, including the ITER project. Here, this study introduces an experimental study based on the X-Ray Diffractometry (XRD) method to evaluate the performance of HOPG reflectors. The experimental method provides both the angular responses and the reflectivities of the HOPG reflectors. A demonstrative XRD experiment is conducted, and the details of the experiment are introduced. This method enables precise studies on HOPG reflectors, facilitating the design of XCS diagnostic systems for future tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Systematic Operating Temperature Differences Between Al-BSF, PERC, and PERT-With-Optimized-Rear-Reflector Solar Mini-Modules Due to Rear Reflectance

Reflecting sub-bandgap light from photovoltaic modules has the potential to improve lifetime energy generation of fielded systems by reducing operating temperature. In this article, the temperature of fielded aluminum back-surface field (Al-BSF) and passivated emitter and rear contact (PERC) mini-modules was monitored every 5 minutes for 75 days along with corresponding meteorological data. Additionally, passivated emitter rear totally diffused (PERT) mini-modules with high-performance sub-bandgap rear reflectors were tested and compared to the state-of-the-art industrial modules. These reflectors consisted of a >300-nm-thick silicon dioxide nanoparticle film with a low refractive index. The impact of reflectance on measured operating temperature was isolated with a previously developed thermal model and quantified as the reflectance-induced median temperature difference between each tested module at representative outdoor conditions (1000 W m -2 , 25 degrees C ambient temperature, and 1.43 m s -1 wind speed). We found that, because of their reflectance differences, PERC modules ran systematically cooler than Al-BSF modules by 1.0 degrees C, whereas the PERT-with-optimized-rear-reflector systematically operated 1.4 degrees C cooler than the Al-BSF module and 0.4 degrees C than the PERC module. We also found that the rear reflector provided the greatest temperature benefit during periods of highest irradiance.

14 SOLAR ENERGY↗

Sensitivity Calculations for Systems with Polyethylene Reflector Materials Using CLUTCH

The SCALE 6.2.4 code package contains four sequences for calculating $k_{eff}$ sensitivity coefficients. Two of these sequences use deterministic transport solvers: a one-dimensional (1D) capability based on XSDRN, and a two-dimensional (2D) capability based on NEWT. These sequences are restricted to the multigroup (MG) treatment of neutron energy. The three-dimensional (3D) sequences use the KENO V.a or KENO-VI Monte Carlo transport codes and can be used to calculate sensitivity coefficients with either MG or continuous-energy (CE) transport. The 3D sensitivities are ultimately reported in an MG structure, regardless of the method used in the transport calculations. If desired, the sensitivity coefficients can be reported with very fine energy resolution from a CE calculation, but they are calculated only in the MG library structure in the MG mode. CE TSUNAMI methods are available in SCALE starting in SCALE version 6.2. Sensitivity coefficients were generated using the 3D sequences as part of the generation of the SCALE 6.2.2 Validation Report; difficulties encountered when using the CLUTCH method for thick, fissionable-material reflectors were discussed and investigated as documented in a previous paper. This paper discusses the difficulties encountered in generating accurate sensitivity coefficients using the CLUTCH technique for polyethylene reflectors for two fast spectrum benchmarks. Direct perturbation (DP) calculations were performed to confirm the accuracy of the total sensitivity coefficient for important isotopes with large sensitivities in the system. Discrepancies were detected for CLUTCH-calculated sensitivity coefficients in the reflector of a critical experiment with a radial polyethylene reflector. A simple polyethylene-reflected plutonium sphere was then used to further investigate the discrepancy. Calculations performed using the iterated fission probability (IFP) method generated accurate sensitivity coefficients in both cases. The results of this study emphasize the need to confirm CLUTCH sensitivity results with DP calculations. IFP calculations are generally less efficient but more reliable than CLUTCH calculations. Improvements to the CLUTCH methodology that retain the greater efficiency but address identified difficulties are therefore potentially useful to analysts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reactor Physics Simulations of the High Flux Isotope Reactor Permanent Beryllium Reflector Number 5 Design

This study evaluates reactor physics aspects of the proposed High Flux Isotope Reactor (HFIR) permanent beryllium reflector number 5 design. HFIR is a pressurized, light water–cooled, and beryllium reflected research reactor that operates at 85 MW for cycle lengths of approximately 24 to 26 days. A new permanent reflector design is highly desirable for increased versatility in irradiation experiments, to arrange the vertical experiment facilities (VXFs) to minimize their impact on neutron scattering if loaded with neutronabsorbing experiments, to enhance reflector thermal-structural-hydraulic performance, and to simplify the complex fabrication process. The current number 4 and concept number 5 reflectors have 22 and 28 VXFs, respectively, and are modeled and analyzed in this study with the MCNP5 and SCALE 6.1.3 nuclear simulation codes.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

IER-479/547: Low-Temperature TEX Surrogate Testing and Reflector Design [Slides]

This lecture includes a look into progress in surrogate testing. This includes a new chiller that has been fabricated and testing that has resumed. Additional tests are being conducted, including: using formed aluminum gaskets, extended testing with natural uranium, testing with pseudo-spindle, testing with no vacuum. This lecture includes a look into the Reflector Design. Results for detailed model are consistent with results presented in CED-2. Calculations provide flexibility in the physical design of the reflectors (e.g. reflector segment widths and heights). Provided initial CAD models of reflector components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multiple-beam spherical reflector antenna

A spherical reflector with multiple feeds is considered for application in communications satellite systems. Data are presented which show that spherical reflectors possessing relatively high gain (40 db) and very small phase path error are feasible. A design of a spherical reflector utilizing corrugated horn feeds is considered. Radiation patterns are computed using the physical-optics technique. The designed antenna is approximately 60 lambda in diameter. Calculations performed for this antenna with three beams indicate that each beam has a gain of about 42 db, a beamwidth of 1.4 deg, and sidelobes that can be expected to be at least 28 db down. These results indicate that the feature of low sidelobes makes the spherical reflector a consideration for a multiple-beam communications satellite antenna.

Woo, R.↗

Analysis of the radiation patterns of reflector antennas

The development and application of a numerical technique for rapid calculation of the far-field radiation patterns of a reflector antenna from either a measured or computed feed pattern are reported. The reflector is defined by the intersection of a cone with any surface of revolution or an offset sector of any surface of revolution. The feed is assumed to be linearly polarized and can have an arbitrary location. Both the copolarized and the cross-polarized reflector radiation patterns are computed. Calculations using the technique compare closely with measured radiation patterns of a waveguide-fed offset parabolic reflector. Unique features of this technique are freedom from restrictive feed assumptions and the numerical methods used in preparing the aperture-plane electric-field data for integration.

Kauffman, J. F.↗

Solar thermal collectors using planar reflector

Specular reflectors have been used successfully with flat-plate collectors to achieve exceptionally high operating temperatures and high delivered energy per unit collector area. Optimal orientation of collectors and reflectors can result in even higher performance with an improved relationship between energy demand and supply. This paper reports on a study providing first order optimization of collector-reflector arrays in which single- and multiple-faceted reflectors in fixed or singly adjustable configurations provide delivered energy maxima in either summer or winter.

Espy, P. N.↗

Modular reflector concept study

A study was conducted to evaluate the feasibility of space erecting a 100 meter paraboloidal radio frequency reflector by joining a number of individually deployed structural modules. Three module design concepts were considered: (1) the deployable cell module (DCM); (2) the modular paraboloidal erectable truss antenna (Mod-PETA); and (3) the modular erectable truss antenna (META). With the space shuttle (STS) as the launch system, the methodology of packaging and stowing in the orbiter, and of dispensing, deploying and joining, in orbit, were studied and the necessary support equipment identified. The structural performance of the completed reflectors was evaluated and their overall operational capability and feasibility were evaluated and compared. The potential of the three concepts to maintain stable shape in the space environment was determined. Their ability to operate at radio frequencies of 1 GHz and higher was assessed assuming the reflector surface to consist of a number of flat, hexagonal facets. A parametric study was performed to determine figure degradation as a function of reflector size, flat facet size, and f/D ratio.

Vaughan, D. H.↗

Preliminary design of tetrahedral truss reflector structure

A baseline structure proposed for the microwave radiometer spacecraft (MRS) reflector is a large graphite-epoxy truss. The truss structure was selected to provide adequate stiffness to minimize control problems and to provide a low-expansion 'strong back' on which to mount and control reflector mesh panels. Details of the structural members, joints and assembly concepts are presented, a concept for the reflector mesh surface is discussed, and preliminary estimates of the mass and structural natural frequencies of the reflector system are presented.

Card, M. F.↗

Distorted reflector antenna performance prediction technique

The application of a 3-D curve-fit technique to the electromagnetic analysis of reflector antennas is presented. the reflector antennas are described by the coordinates of an irregular distribution of measured points on the reflector surface. The reflector antenna analysis method used to calculate radiation patterns is geometric-optics with aperture-integration since an efficient and accurate computer code was readily available for modification.

Bailey, M. C.↗