Entry length for the rocket meteorological radiation shield
Thermal entry length of temperature sensor placement in tubular radiation shield
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Thermal entry length of temperature sensor placement in tubular radiation shield
Charged particle motion in magnetic radiation shielding fields
At ITER, the confluence of a high radiation environment and the requirement for high performance imaging for plasma and plasma-facing surface diagnosis will necessitate extensive application of radiation shielding. Recommended here is a dual-layer shield design composed of lead for gamma attenuation, surrounded by a fire-resistant polyehtylene doped with a thermal neutron absorber for neutron shielding.
Radiation safety standards today require comprehensive shielding protection schemes for all particle accelerators. The original shielding system of BJ-20 (BeiJing-20 MeV), the high-energy medical electron linac, was designed only for the 18 MeV level. And the dose caused by the lost electrons in the 270 deg. bending magnet system was neglected. In this paper, the leakage dose of BJ-20 is carefully analyzed. The radiation leakage dose distribution of the photons coming from the accelerator head is obtained for energy levels of 6, 12, 14, and 18 MeV. The dose of the photoneutrons is especially analyzed for the 18 MeV level. The result gives that even neglecting the dose from the 270 deg. bending magnet system, the shielding system is still not enough for the energy levels lower than 18 MeV. The radiation leakage produced by electrons that are lost in the 270 deg. bending magnet system has been particularly studied. Using beam transport theory and Monte Carlo sampling methods, which have been combined in calculations, we have obtained the distribution of the energy, position, and direction of the lost electrons. These data were then further processed by the Monte Carlo N-particle (MCNP) code as input data. The results show that when the electron loss rate in the 270 deg. bending magnet system is 13.5%, the radiation leakage dose of the photons generated by the lost electrons is 0.1% higher than that at the isocenter, and the corresponding relative leakage dose of the photoneutrons reaches 0.045% around an angle of 170 deg. at 18 MeV level. Both of these parameters exceed radioprotection safety standards for medical accelerators. The original shielding design is therefore not suitable and is also incomplete since the radiation produced by the electrons being lost in the 270 deg. bending magnet system was neglected and the leakage dose for the low-energy levels was not considered in the original design. Our calculations provide a very useful tool for further optimization and design improvement that will enable this radiation shielding to conform to present day safety standards.
One of the most significant technical challenges in long-duration space missions is that of protecting the crew from harmful radiation. Protection against such radiation on a manned Mars mission will be of vital importance both during transit and while on the surface of the planet. The development of multifunctional materials that serve as integral structural members of the space vehicle and provide the necessary radiation shielding for the crew would be both mission enabling and cost effective. Additionally, combining shielding and structure could reduce total vehicle mass. Hybrid laminated composite materials having both ultramodulus polyethylene (PE) and graphite fibers in epoxy and PE matrices could meet such mission requirements. PE fibers have excellent physical properties, including the highest specific strength of any known fiber. Moreover, the high hydrogen (H) content of polyethylene makes the material an excellent shielding material for cosmic radiation. When such materials are incorporated into an epoxy or PE matrix a very effective shielding material is expected. Boron (B) may be added to the matrix resin or used as a coating to further increase the shielding effectiveness due to B s ability to slow thermal neutrons. These materials may also serve as micrometeorites shields due to PE s high impact energy absorption properties. It should be noted that such materials can be fabricated by existing equipment and methods. It is the objective of this work therefore to: (a) perform preliminary analysis of the radiation transport within these materials; (b) fabricate panels for mechanical property testing before and after radiation exposure. Preliminary determination on the effectiveness of the combinations of material components on both shielding and structural efficiency will be made.
Test facilities for high-gradient superconducting RF cavities must be shielded for particle radiation, which is generated by field emitted electrons in the cavities. A major challenge for the shielding design is associated with uncertainty in modeling the field emission. In this work, a semi-empirical method that allows us to predict the intensity of the generated field emission is described. Spatial, angular and energy distributions of the generated radiation are calculated with the FISHPACT code. The Monte Carlo code MARS15 is used for modeling the radiation transport in matter. The detailed distributions of the generated field emission are used for studies with 9-cell 1.3 GHz superconducting RF cavities in the Fermilab Vertical Cavity Test Facility. This approach allows us to minimize the amount of shielding inside cryostat which is an essential operational feature.
Estimates are given for the radiation shielding thicknesses required to protect astronauts on interplanetary missions from the effects of large solar flares, on the basis of the integral proton fluences for several past solar particle events. NASA-Langley's nucleon transport deterministic computer code, BRYNTRN, is used to transport primary protons and secondary protons and neutrons through any number of layers of target material of arbitrary thickness and composition. The results of each flare are presented as estimates of dose equivalents to the skin, eyes, and blood-forming organs behind various thicknesses of aluminum shielding.
Future space missions to Mars will require radiation shielding to be optimized for deep space transit and an extended stay on the surface. In deep space, increased shielding levels and material optimization will reduce the exposure from most solar particle events (SPE) but are less effective at shielding against galactic cosmic rays (GCR). On the surface, the shielding provided by the Martian atmosphere greatly reduces the exposure from most SPE, and long-term GCR exposure is a primary concern. Previous work has shown that in deep space, additional shielding of common materials such as aluminum or polyethylene does not significantly reduce the GCR exposure. In this work, it is shown that on the Martian surface, almost any amount of aluminum shielding increases exposure levels for humans. The increased exposure levels are attributed to neutron production in the shield and Martian regolith as well as the electromagnetic cascade induced in the Martian atmosphere. This result is significant for optimization of vehicle and shield designs intended for the surface of Mars.
Protecting humans from space radiation is a major hurdle for human exploration of the solar system and beyond. Like on Earth, large magnetic fields surrounding a spaceship would deflect charged particles away from the habitat region and reduce the radiation dose to acceptable limits. The objective of this study is to determine the feasibility of current state of the art (SOA) high temperature superconducting (HTS) magnets as a means to protect crew from space radiation exposure on long duration missions beyond Low Earth Orbit (LEO). The study will look at architecture concepts to deflect high energy Galactic Cosmic Radiation (GCR) and Solar Proton Events (SPEs). Mass, power, and shielding efficiency will be considered and compared with current passive shielding capabilities. This report will walk the reader through several designs considered over the one year study and discuss the multiple parameters that should be evaluated for magnetic shielding. The study team eventually down-selects to a scalable light weight solenoid architecture that is launchable and then deployable using magnetic pressure to expand large diameter coils. Benefitting from the low temperature and high vacuum environment of deep space, existing high-temperature superconductors make such radiation shields realistic, near-term technical developments.
Meeting radiation protection requirements during EVA is predominantly an operational issue with some potential considerations for temporary shelter. The issue of spacesuit shielding is mainly guided by the potential of accidental exposure when operational and temporary shelter considerations fail to maintain exposures within operational limits. In this case, very high exposure levels are possible which could result in observable health effects and even be life threatening. Under these assumptions, potential spacesuit radiation exposures have been studied using known historical solar particle events to gain insight on the usefulness of modification of spacesuit design in which the control of skin exposure is a critical design issue and reduction of blood forming organ exposure is desirable. Transition to a new spacesuit design including soft upper-torso and reconfigured life support hardware gives an opportunity to optimize the next generation spacesuit for reduced potential health effects during an accidental exposure.
Intensive Monte Carlo simulations performed with state-of-the-art computation codes are applied to the radiation shielding design of LCLS-II, which will be the extension of Linac Coherent Light Source (LCLS) at SLAC and will use the middle one-third of SLAC two-mile Linac. This paper describes the Monte Carlo studies of the first and last system where electron beams are involved, namely the LCLS-II Injector and the X-ray Transport and Diagnostics System (XTOD).
The radiation shielding analysis of the external concrete enclosure of a feature long beamline of the Advanced Photon Source Upgrade project is described in this work. The beamline has 2 undulators that can operate in two different configurations and the source terms are estimated for the worst configuration using the SRW code in the OASYS package as well as the STAC8 code. The shielding analysis is carried out using the STAC8 code, and for the case of pink beam, with the FLUKA code also. Effective dose rates on contact with the outside surface of the concrete walls for pink, reflected full spectrum and monochromatic beams are calculated. For the monochromatic beams, 2 sets of discrete bandwidths (BW) from the Double Crystal Monochromator (DCM) and the full reflectance of the Double Multilayer Monochromator (DMM) are used. Further, due to the size of the direct beam and the energy domain of interest in the direct and scattered fields, the importance of the equivalent dose to the lens of the eye is discussed with respect to the shielding calculations of such facilities. The dose rates outside the concrete hutch in the lateral directions calculated using STAC8 is about 50% higher than the FLUKA results for the case of pink beam but may be considered as a reasonable agreement due to the differences in the calculational methodologies. Those dose rates in the lateral and forward directions are higher for the pink beam to allow full occupancy from the radiation protection point of view. For the full spectrum after 3 reflections, the effective dose rates are less than 0.5 Sv/h in the lateral direction but is higher in the forward region below about 22° with respect to the beam direction. For the DCM beams, except for the scenario with one mirror and 0.1%BW, all dose rates are less than 0.5 Sv/h outside the concrete hutch in the lateral directions. Here, the higher harmonics are what contributes to the dose outside the shield and the bandwidths assumed to derive the photon flux thus becomes important. The dose rates with the DMM are generally lower compared to the 0.1% BW DCM beam but are higher than the results obtained with XOP calculated bandwidths.
The CSSI beamline of the APSU will have a 20.5 m long, 2.75 m diameter SS end station designed to accept pink beam. In this work, the radiation shielding analysis of this end station is analyzed using STAC8 and FLUKA codes. Effect of mirror properties such as reflectivity, coating, inclination and roughness as well as variation in the steel composition are also studied. 8 mm thick SS is found to be adequate if the source is defined by a pinhole and the white beam is reflected with two mirrors inclined at 3.0 mradian or more. The dose rates from monochromatic beams are found to be below the desired levels when the XOP calculated bandwidth (BW) are used while the use of a flat 0.1% BW requires the mirror inclinations to be above 2.5 mradian or more. STAC8 results are consistently higher than the FLUKA results by about 1.5–2.0 times.
Point-kernel radiation shielding computer program to evaluate propellant heating and dose to crew during engine operation
A feasibility demonstration model of a new-technology, high-performance, cryogenic radiative cooler has been successfully tested in a helium-cooled vacuum chamber. Thermal isolation of the radiator cold stage from the warm spacecraft and instrument is achieved by a novel arrangement of lightweight radiation shields which form large V-groove cavities, and by the use of low-conductance structural supports. The vacuum chamber experiments demonstrate the thermal isolation capability of the radiator design. Analytical model predictions are all within 1 K of the measured test temperatures. Utilization of this design enables reasonably sized radiative coolers (less than 0.3 sq m) to achieve operating temperatures below 60 K at earth, Mars, and beyond for useful cooling loads below 75 mW. The design can be scaled to accommodate larger heat loads. The reduction in operating temperature of over 15 K relative to any radiative cooler flown in the past will allow the V-groove isolation radiator to meet the challenging instrument cooling requirements of many future space missions.
Updates to the radiation shielding of the test facility VTS2/3 designed to meet operational restrictions are presented.
This Technical Memorandum covers revolutionary ideas for space radiation shielding that would mitigate mission costs while limiting human exposure, as studied in a workshop held at Marshall Space Flight Center at the request of NASA Headquarters. None of the revolutionary new ideas examined for the .rst time in this workshop showed clear promise. The workshop attendees felt that some previously examined concepts were de.nitely useful and should be pursued. The workshop attendees also concluded that several of the new concepts warranted further investigation to clarify their value.
A radiation shielding has been designed to reduce scattered neutrons and background gamma-rays for the new double-ring Time Of Flight Enhanced Diagnostics (TOFED). The shielding was designed based on simulation with the Monte Carlo code MCNP5. Dedicated model of the EAST tokamak has been developed together with the emission neutron source profile and spectrum; the latter were simulated with the Nubeam and GENESIS codes. Significant reduction of background radiation at the detector can be achieved and this satisfies the requirement of TOFED. The intensities of the scattered and direct neutrons in the line of sight of the TOFED neutron spectrometer at EAST are studied for future data interpretation.