Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pulse generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

TV synchronization system features stability and noise immunity

Horizontal jitter in the video presentation in television systems is prevented by using an additional sync level. This circuitry uses simultaneous signals at both sync and porch frequencies, providing a sync identification from which a coincidence circuit can generate pulses having the required stability and noise immunity.

Landauer, F. P.↗

Run numbering system for use with data recorders

Run numbering identification system provides a permanent identification on the recorder traces of data runs. It automatically enters, by pulse coding, the number of the current data run on the recorder trace. The system uses a keyboard, registers, converters, amplifiers, and a pulse generator.

Pease, L. L.↗

Electrical instrument measures position and velocity of shock waves

Instrument employs a sensor consisting of twin-electrode probe mounted in shock tube wall, with small dc voltage impressed across electrodes. Power supply, amplifier, and gate pulse generator complete the system. Instrument provides data for construction of wave diagrams, as well as measurement of shock velocity.

Dannenberg, R. E.↗

A measurement of the fast luminescent decays of the MV-50 LED.

The fast luminescent decay of the MV-50 GaAs doped Si light-emitting diode has been studied. This diode is found to provide a fast, inexpensive, bright, and convenient light source for the calibration of fast optical timing systems. A simple passive electronic module is described that allows driving the light source directly by a laboratory pulse generator.

Sutton, J. F.↗

Method and apparatus for nondestructive testing

High voltage is applied to an arc gap adjacent to a test specimen to develop a succession of high frequency arc discharges. Those high frequency arc discharges generate pulses of ultrasonic energy within the test specimen without requiring the arc discharges to contact that test specimen and without requiring a coupling medium. Those pulses can be used for detection of flaws and measurements of certain properties and stresses within the test specimen.

Hoop, J. M.↗

Digital controller for a Baum folding machine

A digital controller for controlling the operation of a folding machine enables automatic folding of a desired number of sheets responsive to entry of that number into a selector. The controller includes three decade counter stages for corresponding rows of units, tens and hundreds push buttons. Each stage including a decimal-to-BCD encoder, a buffer register, and a digital or binary counter. The BCD representation of the selected count for each digit is loaded into the respective decade down counters. Pulses generated by a sensor and associated circuitry are used to decrease the count in the decade counters. When the content of the decade counter reaches either 0 or 1, a solenoid control valve is actuated which interrupts operation of the machine. A repeat switch, when actuated, prevents clearing of the buffer registers so that multiple groups of the same number of sheets can be folded without reentering the number into the selector.

Bryant, W. H.↗

Phase-locked servo system

A phase lock servo system is described for synchronizing the rotation of a slip ring assembly with the rotation of an air bearing table so that a minimum of torque will be imparted through cables extending from the slip ring assembly to the air bearing table as such is rotated. The system includes two servo loops. The first servo loop includes a rate gyroscope carried on the air bearing table which generates a signal through a summing junction to be compared with a signal coming from a tachometer coupled to the slip ring assembly. The corrective signal is applied to a torque motor for rotating the slip ring assembly. The second servo loop includes a pair of photo detector cells which generate pulses responsive to the rotation of the air bearing table and slip ring assembly which are fed through a phase detector, and a variable gain amplifier to the summing junction circuit to provide a fine adjustment for rotating the slip ring assembly.

Burdin, C.↗

Increasing the isotropic properties of a discharge spark chamber with a large gap

The recording of particle tracks in the form of sparks or streamers running at different angles toward the electric field of the chamber was studied. The investigations were performed with two discharge spark chambers consisting of boxes filled with neon at 1 atm. The spark chambers were powered by a pulse with an amplitude of 300 kV applied from a pulse generator. The recording of particle tracks in the form of sparks took place at track angles smaller than 30 deg with respect to the electrical field. At angle larger than 40 deg the tracks are recorded in the form of streamers. Particle traces with respect to the angle are given.

Nurgozhin, N. N.↗

A very-long-baseline interferometer system for geodetic applications

A very-long-baseline interferometer system was designed and built for geodetic applications. Each interferometer terminal records a 360-kHz spectral band of noise from a compact extragalactic radio source. The center frequency of the spectral band can be selected to sample sequentially bands covering a much wider frequency range to obtain subnanosecond accuracy in group-delay measurements. A tunnel-diode pulse generator is used to calibrate the delays in the receiver. The necessary sets of algorithms and computer programs have been developed to analyze the data and have allowed the system to be employed to make accurate determinations of vector baselines, radio-source positions, polar motion, and universal time.

Whitney, A. R.↗

The dc-to-dc converters employing staggered-phase power switches with two-loop control

A switched inductor voltage is coupled to a sense winding in each phase, and all sense windings are connected in series to one of two feedback loops to provide a signal that indicates when one of the power switches is on as the principal determinant of switching instants. A sequencer is triggered each time a pulse generator is triggered to turn on a different power switch in sequence at each switching instant.

Wester, G. W.↗

Sustained arc ignition system

Circuitry for maintaining an arc or spark across a spark gap for a desired length of time is disclosed. A high voltage, direct current source is connected in series with a secondary winding of a high voltage, stepup transformer or coil and a spark gap such as a spark plug for example. The high voltage source may be on continuously or may be turned on and off by a control circuit such as a solid state switch which is, in turn, responsive to a timing device such as a set of ignition contact points or a magnetic pulse generator operating in synchronism with a spark ignition engine. The timing device also provides signals to a current switching circuit which interrupts, current flow through a primary winding of the high voltage coil at the prescribed time that a spark is desired at the spark gap.

Birchenough, A. G.↗

Tube method of sound-absorption measurement extended to frequencies far above cutoff

Equipment had been constructed for measuring sound absorption in the frequency range from 4 to 100 kHz in a large tube 25.4 cm in diameter and 4.8-m long. The technique employs a large moveable solid-dielectric capacitance transducer that completely fills the tube cross section and generates pulses of plane waves. An identical transducer terminates the other end of the tube and serves as a microphone to detect and reflect the sound pulses. Measurements in argon, nitrogen, and air indicate that the attenuation of the sound pulses differs by less than 1% from values calculated for the zero-order mode for frequencies up to 44 times the cutoff frequency for the first 'nonplane' mode. Above that frequency, the measured values are less than those predicted by theory by an amount that is approximately proportional to the wavelength to the -3.1 power. In a smaller tube of similar construction, the high-frequency deviation from theory is absent.

Shields, F. D.↗