Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Evidence for temporal variations in polar plumes

The variability of the O VI and Mg X emissions from four plumes is studied in order to place empirical constraints on possible plasma heating processes and acceleration mechanisms for mass flows in polar plumes. The observations comprise a 40 min seqeunce of spectroheliograms acquired with a temporal resolution of approximately 2 min. It is found that the Mg X emission from each plume has a strong 'dc' component and that any variations occurred at approximately the 10 percent (of the mean) level or less. This means that temporal variations in the density and/or temperature were 5 percent or less. Some statistically significant variations in the measured Mg X signals are seen. It is noted that two of the plumes decreased in brightness by approximately 10 percent during the 40 min period of the observations. Besides this, two plumes exhibited short-term (few minute) variations that are seen as statistically significant at a confidence level of more than 90 percent. The latter variations (if real) are thought to be due to small (approximately 20,000 K) fluctuations in temperature caused by fluctuations in the local plasma heating rate.

Withbroe, G. L.↗

Active Region Moss: Doppler Shifts from Hinode/EIS Observations

Studying the Doppler shifts and the temperature dependence of Doppler shifts in moss regions can help us understand the heating processes in the core of the active regions. In this paper we have used an active region observation recorded by the Extreme-ultraviolet Imaging Spectrometer (EIS) onboard Hinode on 12-Dec- 2007 to measure the Doppler shifts in the moss regions. We have distinguished the moss regions from the rest of the active region by defining a low density cut-off as derived by Tripathi et al. (2010). We have carried out a very careful analysis of the EIS wavelength calibration based on the method described in Young, O Dwyer and Mason (2012). For spectral lines having maximum sensitivity between log T = 5.85 and log T = 6.25 K, we find that the velocity distribution peaks at around 0 km/s with an estimated error of 4 km/s. The width of the distribution decreases with temperature. The mean of the distribution shows a blue shift which increases with increasing temperature and the distribution also shows asymmetries towards blue-shift. Comparing these results with observables predicted from different coronal heating models, we find that these results are consistent with both steady and impulsive heating scenarios. Further observational constraints are needed to distinguish between these two heating scenarios.

Tripathi, Durgesh↗

Resolving the xi Boo Binary with Chandra, and Revealing the Spectral Type Dependence of the Coronal "Fip Effect"

On 2008 May 2, Chandra observed the X-ray spectrum of xi Boo (G8 V+K4 V), resolving the binary for the first time in X-rays and allowing the coronae of the two stars to be studied separately. With the contributions of ξ Boo A and B to the system's total X-ray emission now observationally established (88.5% and 11.5% respectively), consideration of mass loss measurements for GK dwarfs of various activity levels (including one for xi Boo) leads to the surprising conclusion that xi Boo B may dominate the wind from the binary, with xi Boo A's wind being very weak despite its active corona. Emission measure (EM) distributions and coronal abundances are computed for both stars and compared with Chandra measurements of other moderately active stars with G8-K5 spectral types, all of which exhibit a narrow peak in EM near log T = 6.6, indicating that the coronal heating process in these stars has a strong preference for this temperature. As is the case for the Sun and many other stars, our sample of stars shows coronal abundance anomalies dependent on the first ionization potential (FIP) of the element. We see no dependence of the degree of FIP effect on activity, but there is a dependence on spectral type, a correlation that becomes more convincing when moderately active main-sequence stars with a broader range of spectral types are considered. This clear dependence of coronal abundances on spectral type weakens if the stellar sample is allowed to be contaminated by evolved stars, interacting binaries or extremely active stars with logLX 29, explaining why this correlation has not been recognized in the past.

CHANDRA↗

Proportional and Integral Thermal Control System for Large Scale Heating Tests

The National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) Flight Loads Laboratory is a unique national laboratory that supports thermal, mechanical, thermal/mechanical, and structural dynamics research and testing. A Proportional Integral thermal control system was designed and implemented to support thermal tests. A thermal control algorithm supporting a quartz lamp heater was developed based on the Proportional Integral control concept and a linearized heating process. The thermal control equations were derived and expressed in terms of power levels, integral gain, proportional gain, and differences between thermal setpoints and skin temperatures. Besides the derived equations, user's predefined thermal test information generated in the form of thermal maps was used to implement the thermal control system capabilities. Graphite heater closed-loop thermal control and graphite heater open-loop power level were added later to fulfill the demand for higher temperature tests. Verification and validation tests were performed to ensure that the thermal control system requirements were achieved. This thermal control system has successfully supported many milestone thermal and thermal/mechanical tests for almost a decade with temperatures ranging from 50 F to 3000 F and temperature rise rates from -10 F/s to 70 F/s for a variety of test articles having unique thermal profiles and test setups.

Thermal Control System↗

Verification of thermal analysis codes for modeling solid rocket nozzles

One of the objectives of the Solid Propulsion Integrity Program (SPIP) at Marshall Space Flight Center (MSFC) is development of thermal analysis codes capable of accurately predicting the temperature field, pore pressure field and the surface recession experienced by decomposing polymers which are used as thermal barriers in solid rocket nozzles. The objective of this study is to provide means for verifications of thermal analysis codes developed for modeling of flow and heat transfer in solid rocket nozzles. In order to meet the stated objective, a test facility was designed and constructed for measurement of the transient temperature field in a sample composite subjected to a constant heat flux boundary condition. The heating was provided via a steel thin-foil with a thickness of 0.025 mm. The designed electrical circuit can provide a heating rate of 1800 W. The heater was sandwiched between two identical samples, and thus ensure equal power distribution between them. The samples were fitted with Type K thermocouples, and the exact location of the thermocouples were determined via X-rays. The experiments were modeled via a one-dimensional code (UT1D) as a conduction and phase change heat transfer process. Since the pyrolysis gas flow was in the direction normal to the heat flow, the numerical model could not account for the convection cooling effect of the pyrolysis gas flow. Therefore, the predicted values in the decomposition zone are considered to be an upper estimate of the temperature. From the analysis of the experimental and the numerical results the following are concluded: (1) The virgin and char specific heat data for FM 5055 as reported by SoRI can not be used to obtain any reasonable agreement between the measured temperatures and the predictions. However, use of virgin and char specific heat data given in Acurex report produced good agreement for most of the measured temperatures. (2) Constant heat flux heating process can produce a much higher heating rate than the radiative heating process. The results show that heating rates of 125 C/s (225 F/s) can be achieved. (3) The electrical resistance of the FM 5055 samples were about 150 Omega in the virgin state, and decreased to about 35 Omega when charred. A reliable scheme must be developed to electrically insulate the composite from the heater foil in order to prevent any current leakage into the sample which can result in volumetric heating of the char zone of the composite.

Keyhani, M.↗

Advanced Extravehicular Protective Systems (AEPS) study

A description is given of life support subsystem concepts for advanced extravehicular protective systems (AEPS) intended for use on future orbital, lunar surface, and Mars surface missions in the late 1970's and 1980's. Primary interest was centered around the thermal control and carbon dioxide control subsystems because they offer the greatest potential for total weight savings. Emphasis was placed on the generation of regenerable subsystem concepts; however, partially regenerable and expendable concepts were also considered. Previously conceived and developed subsystem concepts were included in the study. Concepts were evaluated on the basis of subsystem weight and volume, and subsystem contribution to parent vehicle weight and volume, which included spares, regeneration equipment, expendables, expandables storage penalty, power penalty, and process heating or cooling penalty. Results are presented showing total weight and volume penalty as a function of total mission extravehicular activity (EVA) hours, and showing EVA weight and volume as a function of EVA duration. Subsystem concepts are recommended for each life support function, and secondary concepts which should be developed are also identified.

Williams, J. L.↗

Initial results from the NASA Lewis Bumpy Torus experiment

Initial results were obtained from low power operation of the NASA Lewis Bumpy Torus experiment, in which a steady-state ion heating method based on the modified Penning discharge is applied in a bumpy torus confinement geometry. The magnet facility consists of 12 superconducting coils, each 19 cm i.d. and capable of 3.0 T, equally spaced in a toroidal array 1.52 m in major diameter. A 18 cm i.d. anode ring is located at each of the 12 midplanes and is maintained at high positive potentials by a dc power supply. Initial observations indicate electron temperatures from 10 to 150 eV, and ion kinetic temperatures from 200 eV to 1200 eV. Two modes of operation were observed, which depend on background pressure, and have different radial density profiles. Steady state neutron production was observed. The ion heating process in the bumpy torus appears to parallel closely the mechanism observed when the modified Penning discharge was operated in a simple magnetic mirror field.

Roth, J. R.↗

G-189A analytical simulation of the integrated waste management-water system using radioisotopes for thermal energy

An analytical simulation of the RITE-Integrated Waste Management and Water Recovery System using radioisotopes for thermal energy was prepared for the NASA-Manned Space Flight Center (MSFC). The RITE system is the most advanced concept water-waste management system currently under development and has undergone extended duration testing. It has the capability of disposing of nearly all spacecraft wastes including feces and trash and of recovering water from usual waste water sources: urine, condensate, wash water, etc. All of the process heat normally used in the system is produced from low penalty radioisotope heat sources. The analytical simulation was developed with the G189A computer program. The objective of the simulation was to obtain an analytical simulation which can be used to (1) evaluate the current RITE system steady state and transient performance during normal operating conditions, and also during off normal operating conditions including failure modes; and (2) evaluate the effects of variations in component design parameters and vehicle interface parameters on system performance.

Coggi, J. V.↗

Grossular in the Allende /Type III carbonaceous/ meteorite

Grossular garnet has been observed in several white inclusions in the Allende meteorite. Compositions range from Gro(95)Py(5) to Gro(88)Py(12) in five inclusions. Its mottled appearance indicates that it crystallized from a glass of near-grossular composition and not by a solid-state reaction between wollastonite, anorthite, and melilite. These grossular-bearing inclusions either condensed directly as metastable liquids from the solar nebula or, if initial solid condensates were liquefied, by some subsequent heating process. In either case, a prolonged residence time in a thermal blanket appears necessary to effect crystallization of the grossular.

Fuchs, L. H.↗

Atmospheric heating by solar EUV radiation

A diurnal model of the mid-latitude ionospheric R region is used to calculate the diurnal variation of the neutral gas heating rates and neutral gas heating efficiency for conditions similar to those over Millstone Hill on March 23-24, 1970. The calculations show that the absorbed solar EUV (wavelength less than or equal to 1025 A) energy is almost equally split between photoelectrons and ion pair production. Photoelectrons heat the ambient electron gas by Coulomb collisions and by the quenching of certain excited ion species, whereas the ion gas is primarily heated by collisions with hot electrons and by chemical reactions. Heating processes above 300 km, between 170 and 300 km, and below 170 km are identified.

Stolarski, R. S.↗

Assembly and testing of a 1.8 by 3.7 meter Fresnel lens solar concentrator

A project was initiated to establish a technical data base on line focusing acrylic Fresnel lenses for use in a solar collector system that could generate temperatures in the range of 200 C to 370 C. The effort was originally directed toward electric power generation in the 100 to 10,000 kWe range using a distributed collector approach. However, as the program progressed, it centered on the development of a concentrator/collector subsystem concept that could meet the general requirement of thermal delivery within the 200 C to 370 C range. The expanded list of possible applications includes commercial heating/cooling and industrial process heat as well as electric power generation.

Robertson, J. E.↗

Experimental evaluation of a stationary spherical reflector tracking absorber solar energy collector

This article presents experimental data for the thermal performance of a stationary, spherical-reflector, tracking-absorber solar energy collector (SRTA). The principle of operation and details of thermal performance of such an SRTA have previously been described. These experimental results were compared with the predictions of a thermal analysis previously published. Experimental results were compared with the prediction of Kreider's computer model. Within the range of the temperature of the experiments, the predicted performance of the unit agreed well with experimental data collected under clear sky conditions. In addition, the extrapolation of the efficiency to higher temperature is shown so that the potential of an SRTA solar collector as a means of providing high temperature steam to operate an electric power facility or for process heat can be evaluated. As a result of the tests conducted by NASA, and an economic analysis not yet publicly available, it appears that the SRTA solar collector concept will be economically viable in competition with any other existing solar system in providing electrical energy.

Steward, W. G.↗

Cogeneration power systems

Cogeneration is defined as the combination of electrical generation and process heat for more efficient use of fuel. Comparisons of energy utilization in conventional electric power plants and cogeneration electric power plants are presented. Characteristics of various cogeneration systems are also presented. Systems are analyzed for use in utility systems and industrial systems. Economic and cost analysis are reviewed.

Davis, H. S.↗

Emerging Energy Alternatives for the Southeastern States

The proceedings of the first symposium on emerging energy alternatives for the Southeastern States are presented. Some topics discussed are: (1) solar energy, (2) wood energy, (3) novel energy sources, (4) agricultural and industrial process heat, (5) waste utilization, (6) energy conservation and (7) ocean thermal energy conversion.

Stefanakos, E. K.↗

Development of flat-plate solar collectors for the heating and cooling of buildings: Executive summary

An efficient, low cost, flat-plate solar collector was developed. Computer aided mathematical models of the heat process in the collector were used in defining absorber panel configuration; determining insulation thickness; and in selecting the number, spacing, and material of the covers. Prototypes were built and performance tested. Data from simulated operation of the collector are compared with predicted loads from a number of locations to determine the degree of solar utilization.

Source record↗

Energy conservation through sealing technology

Improvements in fluid film sealing resulting from a proposed research program could lead to an annual energy saving, on a national basis, equivalent to about 37 million bbl of oil or 0.3% of the total U.S. energy consumption. Further, the application of known sealing technology can result in an annual saving of an additional 10 million bbl of oil. The energy saving would be accomplished by reduction in process heat energy loss, reduction of frictional energy generated, and minimization of energy required to operate ancillary equipment associated with the seal system. In addition to energy saving, cost effectiveness is further enhanced by reduction in maintenance and in minimization of equipment for collecting leakage and for meeting environmental pollution standards.

Stair, W. K.↗

Absorption of whistler mode waves in the ionosphere of Venus

It is shown that whistler mode waves from the ionosheath of Venus are absorbed by Landau damping at the dayside ionosphere boundary. This process heats the ionospheric electrons and it may provide an important energy input into the dayside ionosphere. Cyclotron damping of the waves does not occur in the same region. However, Landau damping of ionosheath waves is apparently not an important energy source in the nightside ionosphere. Impulsive events in the nightside ionosphere seem to fall into two classes: (1) lightning signals (near periapsis) and (2) noise, which may be caused by gradient or current instabilities.

Taylor, W. W. L.↗

Cogeneration Technology Alternatives Study (CTAS). Volume 1: Summary

Various advanced energy conversion systems that can use coal or coal-derived fuels for industrial cogeneration applications were compared to provide information needed by DOE to establish research and development funding priorities for advanced-technology systems that could significantly advance the use of coal or coal-derived fuels in industrial cogeneration. Steam turbines, diesel engines, open-cycle gas turbines, combined cycles, closed-cycle gas turbines, Stirling engines, phosphoric acid fuel cells, molten carbonate fuel cells, and thermionics were studied with technology advancements appropriate for the 1985-2000 time period. The various advanced systems were compared and evaluated for wide diversity of representative industrial plants on the basis of fuel energy savings, annual energy cost savings, emissions savings, and rate of return on investment as compared with purchasing electricity from a utility and providing process heat with an on-site boiler. Also included in the comparisons and evaluations are results extrapolated to the national level.

Barna, G. J.↗