Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Precise measurement of $2νββ$ decay of $^{100}$Mo with the CUPID-Mo detection technology

We report the measurement of the two-neutrino double-beta ($2\nu\beta\beta$) decay of $^{100}$Mo to the ground state of $^{100}$Ru using lithium molybdate (\crystal) scintillating bolometers. The detectors were developed for the CUPID-Mo program and operated at the EDELWEISS-III low background facility in the Modane underground laboratory. From a total exposure of $42.235$ kg$\times$d, the half-life of $^{100}$Mo is determined to be $T_{1/2}^{2\nu}=[7.12^{+0.18}_{-0.14}\,\mathrm{(stat.)}\pm0.10\,\mathrm{(syst.)}]\times10^{18}$ years. This is the most accurate determination of the $2\nu\beta\beta$ half-life of $^{100}$Mo to date. We also confirm, with the statistical significance of $>3\sigma$, that the single-state dominance model of the $2\nu\beta\beta$ decay of $^{100}$Mo is favored over the high-state dominance model.

01 COAL, LIGNITE, AND PEAT↗

New high precision measurements of the cosmic charged particle rate beyond the Arctic Circle with the PolarquEEEst experiment

The goal of the PolarquEEEst experiment was to measure the cosmic charged particle rate at latitudes greater than 66° N, where no systematic and accurate measurements at sea level have ever been performed. A latitude range well above the Arctic Circle was explored on board of a sailboat, up to the unprecedented northernmost value of 82°07' N. In this paper a description of the experimental set-up is reported, then the procedures for calibration and data analysis are described in detail. The results show that the rate measured in this latitude range stays constant within a novel accuracy of ±1%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise measurements of W - and Z -boson transverse momentum spectra with the ATLAS detector using pp collisions at $\sqrt{s} = 5.02$ TeV and 13 TeV

This paper describes measurements of the transverse momentum spectra of W and Z bosons produced in proton–proton collisions at centre-of-mass energies of $\sqrt{s}$ = 5.02 TeV and $\sqrt{s}$ = 13 TeV with the ATLAS experiment at the Large Hadron Collider. Measurements are performed in the electron and muon channels, W → $\ell$$v$ and Z → $\ell$$\ell$ ($\ell$ = e or μ), and for W events further separated by charge. The data were collected in 2017 and 2018, in dedicated runs with reduced instantaneous luminosity, and correspond to 255 and 338 pb -1 at $\sqrt{s}$ = 5.02 TeV and 13 TeV, respectively. These conditions optimise the reconstruction of the W-boson transverse momentum. The distributions observed in the electron and muon channels are unfolded, combined, and compared to QCD calculations based on parton shower Monte Carlo event generators and analytical resummation. The description of the transverse momentum distributions by Monte Carlo event generators is imperfect and shows significant differences largely common to W - , W + and Z production. The agreement is better at $\sqrt{s}$ = 5.02 TeV, especially for predictions that were tuned to Z production data at $\sqrt{s}$ = 7 TeV. Higher-order, resummed predictions based on DYTurbo generally match the data best across the spectra. Distribution ratios are also presented and test the understanding of differences between the production processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise measurement of the tt¯ production cross-section and lepton differential distributions in eμ dilepton events from s=13TeVpp collisions with the ATLAS detector

The inclusive top quark pair (tt¯$$t\bar{t}$$) cross-section σtt¯$$\sigma _{t\bar{t}}$$ has been measured in proton–proton collisions at s=13TeV$$\sqrt{s}=13\,\text {TeV}$$, using 140fb-1$$140\,{\text {fb}^{-1}} $$ of data collected by the ATLAS experiment at the Large Hadron Collider. Using events with an opposite-charge eμ$$e\mu $$ pair and b-tagged jets, the cross-section is measured to be: σtt¯=829.3±1.3(stat)±8.0(syst)±7.3(lumi)±1.9(beam)pb,$$\begin{aligned} \sigma _{t\bar{t}} & = 829.3\pm 1.3\,\mathrm {(stat)}\ \pm 8.0\,\mathrm {(syst)}\ \pm 7.3\,\mathrm {(lumi)}\ \\ & \quad \pm 1.9\,\mathrm {(beam)}\,\textrm{pb}, \end{aligned}$$where the uncertainties reflect the limited size of the data sample, experimental and theoretical systematic effects, the integrated luminosity, and the proton beam energy, giving a total uncertainty of 1.3%. The result is used to determine the top quark pole mass via the dependence of the predicted cross-section on mtpole$${m_{t}^\textrm{pole}}$$, giving mtpole=172.8-1.7+1.5$${m_{t}^\textrm{pole}}=172.8^{+1.5}_{-1.7}$$ GeV$$\text {GeV}$$. The same event sample is used to measure absolute and normalised differential cross-sections for the tt¯→eμνν¯bb¯$$t\bar{t} \rightarrow e\mu u \bar{ u }b\bar{b} $$ process as a function of single-lepton and dilepton kinematic variables. Complementary measurements of eμbb¯$$e\mu b\bar{b} $$ production, treating both tt¯$$t\bar{t}$$ and Wt events as signal, are also provided. Both sets of differential cross-sections are compared to the predictions of various Monte Carlo event generators, demonstrating that the state-of-the-art generators Powheg MiNNLO and Powhegbb4l describe the data better than Powheghvq.

Aad, G↗

Precision measurement of the magnetic field in run 1 of the g-2 experiment

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vessel relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Muon g-2 Experiment at Fermilab: Precision Measurements and Nonlinear Beam Dynamics

The Muon g-2 Experiment has achieved a significant milestone by measuring the positive muon anomalous magnetic moment to an unprecedented accuracy of 0.20 ppm, paving the way to a better understanding of particle physics, including beyond-the-Standard-Model possibilities. In the experiment, muons are circulated within a storage ring, and their anomalous precession frequency — the spin precession relative to momentum — is determined from decay positron time and energy data, captured using calorimeters. In support of accurate storage ring simulations, we performed high-order calculations of the field of the experiment's high-voltage quadrupoles. We also carried out accurate, transfer map–based calculations of the storage ring's chromaticity. These calculations are essential for understanding the beam dynamics effects in the Muon g-2 storage ring.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Measurement of the Muon Spin Precession Frequency in the Fermilab Muon g-2 Experiment

The Fermilab Muon $g-2$ Experiment is designed to measure the muon's anomalous magnetic moment, $ a_\mu = (g-2)/2 $ with an accuracy of 140 parts per billion. This quantity is determined from two key measurements; the difference between the muon's spin precession frequency and its cyclotron frequency, given by $\omega_a = \omega_s - \omega_c$, and $\tilde{\omega_p^\prime}$, proportional to the muon-weighted magnetic field.In this talk, we focus on presenting the methodology for determining $\omega_a$. Muons with a momentum of 3.1 GeV are injected into a storage ring, and $\omega_a$ is extracted from the time distribution of decay positrons recorded by 24 electromagnetic calorimeters placed symmetrically inwards around the ring. We present the final result from the muon g-2 collaboration and analysis techniques based on data collected from 2020 to 2023.

Zaid, Estifa'a [Liverpool U.]↗

Precise measurement of charged defects in III-V compounds (2)

The main objective of this research is to obtain a calibration of a low concentration of charged defects in some III-V semiconducting compounds. The experimental technique being used is nuclear magnetic resonance (NMR), and the objective is to be attained through a thorough examination of the properties of the NMR lines of the nuclei in the III-V compounds. The properties of the NMR lines, and how they are influenced by the presence of charged defects are studied theoretically and experimentally.

Soest, J. F.↗

Test stand for precise measurement of impulse and thrust vector of small attitude control jets

A test stand which accurately measures the impulse bit and thrust vector of reaction jet thrusters used in the attitude control system of space vehicles has been developed. It can be used to measure, in a vacuum or ambient environment, both impulse and thrust vector of reaction jet thrusters using hydrazine or inert gas propellants. The ballistic pendulum configuration was selected because of its accuracy, simplicity, and versatility. The pendulum is mounted on flexure pivots rotating about a vertical axis at the center of its mass. The test stand has the following measurement capabilities: impulse of 0.00004 to 4.4 N-sec (0.00001 to 1.0 lb-sec) with a pulse duration of 0.5 msec to 1 sec; static thrust of 0.22 to 22 N (0.05 to 5 lb) with a 5 percent resolution; and thrust angle alinement of 0.22 to 22 N (0.05 to 5 lb) thrusters with 0.01 deg accuracy.

Woodruff, J. R.↗

Precise measurement of charged defects in III-V compounds (supplement 2)

Experimental methods and related theory which will permit the measurement of low concentrations of vacancies and other defects in III-V compound semiconductors are discussed. Once the nature of these defects has been determined, this information can be incorporated into a transport theory for devices constructed from these materials, and experiments conducted to test the theory. The vacancies and other defects in the III-V compounds are detected by measurement of the nuclear magnetic resonance (NMR) line width. Most of the III-V compounds have at least one isotope with a nuclear quadrupole moment. In a crystal with a cubic crystal field (characteristic of most III-V compounds) there is no quadrupole splitting of the Zeeman resonance line. However, a defect removes the cubic symmetry locally and causes splitting which result in a change of the NMR width. This change can be used to detect the presence of vacancies.

Soest, J. F.↗

Precision measurement of changes in physical dimensions

Interferometric method is used to measure small changes in size of optical materials. Error introduced with optical phase shifts occurring with time is overcome by using parts of Fabry-Perot resonators with unequal lengths. Both stability of optical phase shifts upon reflection from multilayer stacks and dimensional stability of optical contacts is measured.

Berthold, J. W., III↗

Precision measurements of NH3 spectral lines near 11 microns using the infrared heterodyne technique

Absolute line-center frequencies for eleven lines of ammonia in near coincidence with CO2-laser transitions have been determined to accuracies of + or -3 MHz by infrared heterodyne detection. These results were obtained by heterodyning a blackbody with a stable grating-tuned CO2 gas laser. A discussion of the apparatus and method of calculation, including error analysis, is presented. With these accurately determined line-center positions, the ammonia molecule will be a useful secondary-frequency standard for diode-laser spectroscopy in the 11-micron wavelength region.

Hillman, J. J.↗

Calibration standards and field instruments for the precision measurement of insolation

The design of a fieldworthy survey instrument based on a developed radiation calibration standard is discussed. The radiometer system, a fieldworthy modification of Pacrad, is an all-weather solar radiometer, and a field test is described which demonstrates the instrument's stability in severe environments over an extended period of time. It is suggested that the instrument may be considered a transfer standard as well as a radiometer. It is hoped that future modifications might reduce the 15-deg view angle and improve the tracking system to eliminate weekly manual declination adjustments.

Reid, M. S.↗