Power Flow in Pulsed-Power Systems: The Influence of Hall Physics and Modeling of the Plasma–Vacuum Interface
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Power system planning aims at ensuring that sufficient supply- and demand-side assets exist to meet electricity demand at all times. For a Texas electric power system with high wind and solar penetrations, we quantify how climate change will affect supply and demand during three types of high stress periods for the power grid: high demand hours, high net demand hours, and high system ramp hours. We specifically quantify effects on demand, reductions in available thermal capacity (i.e. thermal deratings), wind and solar generation, and net demand. We estimate each using meteorological variables from five climate change projections (2041-2050) assuming Representative Concentration Pathway 8.5 and from a reference period (1996-2005). All five projections indicate that climate change will increase demand by up to 2 GWh during high demand hours (4% of demand in the reference period) and increase net demand by up to 3 GWh during high net demand periods (6% of net demand in the reference period). All five projections also indicate thermal deratings will increase during high demand and net demand periods by up to 2 GWh and high net demand ramps will increase by up to 2 GW. Overall, our results indicate compounding effects of climate change in Texas will necessitate greater investment in peak and flexible capacity.
Abstract not provided.
Abstract not provided.
Wind and solar power generators are commonly described by a system of stochastic ordinary differential equations (SODEs) where random input parameters represent uncertainty in wind and solar energy. The existing methods for SODEs are mostly limited to delta-correlated random parameters (white noise). Here we use the Probability Density Function (PDF) method for deriving a closed-form deterministic partial differential equation (PDE) for the joint probability density function of the SODEs describing a power generator with time-correlated power input. The resulting PDE is solved numerically. A good agreement with Monte Carlo Simulations shows accuracy of the PDF method.
Interconnected power systems have experienced a significant increase in its size and complexity, due to continuous topology and operating condition changes. It is computationally burdensome to represent entire system models in detail to conduct power system analysis. In the large-scale power system dynamic simulations, the models in the study area need to be retained in detail while the external area can be reduced without compromising accuracy, which can preserve the full system dynamic properties. This paper develops measurement-based continuous-time dynamic equivalents for power systems in order to both improve the model accuracy of the reduced system and increase the speed of dynamic simulation. Our method is based on a set of measurements at the boundary nodes between the study area and external area. Case studies demonstrate that the measurement-based model can capture the full system behavior sufficiently, and improve computational efficiency.Interconnected power systems experienced a significant increase in size and complexity. It is computationally burdensome to represent the entire system in detail to conduct power system analysis. Therefore, the model of the study system must be retained in detail while the external system can be reduced using system reduction techniques. This paper proposes a measurement-based dynamic equivalent in order to increase both model accuracy and simulation speed. The proposed method uses a set of measurements at the boundary nodes between the study area and external area for model parameter identification. Case studies demonstrate that the measurement-based technique can capture the main system behaviors accurately and improve computational efficiency.
The modern power systems have undergone significant transformations at the generation, transmission, distribution, and utilization levels due to the remarkable advancements in power electronic converter technology. Power electronic converters are now prevalent in various applications, including wind turbine converters, photovoltaic inverters, flexible AC transmission systems (FACTS) and high-voltage DC (HVDC) converters, distributed generators, microgrids, and electric vehicles. The widespread adoption of power electronic converters has revolutionized the power system by providing fast and flexible controllability. However, their unique characteristics, such as fast response, multi-time scale dynamics, reconfigurable control, and varying sizes and capacities, have introduced new stability challenges, fundamentally altering the dynamics of modern power systems.
Nuclear power represents a traditional baseload power component to the grid, while renewables output variable amounts of power at unpredictable times. Nuclear and renewable energy integration (NREI) systems have previously been explored as valuable additions to the existing power grid. Energy storage systems can allow power plants to store energy mechanically using pumped hydro or compressed air, thermally using liquid salt or steam accumulators, or chemically with batteries. The addition of energy storage to NREI systems can allow for the discharge of electricity to adjust to demands placed on the grid. The allocation of energy to adjust to grid demand is explored through a historical 8,760-hour analysis including nuclear, wind, and solar NREI systems with energy storage. The operation of storage systems is compared through simulations of different storage and discharge parameters based off the maximum daily grid demands, and hourly electricity prices. The overall profitability of storage systems is determined by comparing simulation results for the overall net revenue increases exceeding storage efficiency losses. Several NREI systems have increased the value of electricity for both solar PV and wind energy, in combination with nuclear power. Optimization of these systems is developed using MATLAB code and the simulations of the most profitable results are explored.
Inertia in power systems plays an important role in maintaining the stability and reliability of the system by counteracting changes in frequency. However, the traditional sources of synchronous generation are being displaced by renewable resources, which often have no inherent inertia. This paper investigates the impact of reduced system inertia on several aspects of the dynamic stability of power systems, such as angular stability, primary frequency response, and oscillatory modes. This study is performed on a large-scale 2000 bus synthetic Texas model by selectively replacing synchronous generators with inverter-based generation resources. This paper also compares the analysis results obtained by the above-mentioned inertia-reduction approach of renewable integration with another approach in which the inertia constant of all synchronous generators is decreased. This paper demonstrates that only reducing the inertia of all synchronous generators in a system does not provide an accurate analysis of the challenges associated with the reduced system inertia caused by renewable integration.
NREL's Power Electronic Grid Interface (PEGI) Workshop, held October 13, 2020, focused on the research challenges of operating power systems with ever-higher levels of inverter-based generation and power-electronic-based load. This presentation discusses a power hardware-in-the-loop evaluation of inverter controls for 100% inverter-based bulk power systems.
The scale factor for the use of power plants of a certain type refers to the fraction of their use in the overall energy balance of the system. Energy production by wind power plants depends directly on the wind conditions in a particular location and is stochastic in character. Increasing the fraction of these installations in the overall balance of a system also requires an increase in the power reserve capacity. Here the time a power system remains in the power deficit zone is estimated as a function of the fraction of wind power plants in the system structure. Two approaches to the placement of wind power units within a power system are compared– individual components and a system of a set of components. It is concluded that even within a small power system, combining geographically distributed components with favorable and unfavorable wind conditions into a system can have a positive effect on all the components within certain ranges of the scale factor.
This paper proposes a new formulation and solution algorithm that uses transmission level solar inverters to address the security-constrained optimal power flow (SCOPF) problem. The goal is to stabilize voltage fluctuations in transmission networks in base case and contingency scenarios, by using bulk solar power plant with a minimal number of post-contingency corrections. To achieve this goal, a two-stage volt/var optimization method is proposed to first correct all voltage violations with the volt-var alternating current optimal power flow (ACOPF) algorithm for a base case. Then a linearized SCOPF volt-var control algorithm is proposed to identify the corrective actions for all potential voltage violations in all contingency scenarios. The proposed method was tested and validated on a modified IEEE 118-bus system with solar photovoltaic (PV) data.
The ReNew100 project has developed and demonstrated an operator support system (OSS) to operate power systems with 100% renewable power generation from inverter-based resources (IBRs) like wind and solar that significantly reduces the risk of widespread power outages in a simulated operational environment at Technology Readiness Level (TRL) 6. The OSS achieves resilient operation for power systems under changing operation modes including varying combinations of conventional and renewable generation, including cases with 100% renewable generation from wind and solar IBRs. The OSS continuously monitors the N-1 security of the power system, which refers to the ability of the power systems to survive single outages of power system elements, like the loss of a generator or a power line, without causing widespread power outages beyond those expected and planned for. If the OSS identifies that the system is not N-1 secure, an automatic Controller Parameter Optimization (CoPO) developed within Renew100 is activated to optimize the N-1 security of the system by tuning controller parameters within different assets like batteries, wind, and solar plants. The core innovation of ReNew100 is the development of this CoPO as well as the demonstration of the OSS for a real-time simulation of the Hawai'i Island power system. Moreover, Renew100 has developed new model calibration techniques for dynamic power system models and demonstrated them for Hawai'i Island.
In this paper, we consider the frequency synchronization problem in a network of lossless, connected, and network-reduced power system. Frequency synchronization is an important problem in power systems as frequency deviation can lead to degraded power quality, tripping of generators, etc. We present a load-estimator-based consensus algorithm in a network of fourth-order generator models that achieves practical frequency synchronization in the presence of unknown time-varying power demand. We do not assume that the demand is generated by a known model. We follow a multiple time-scale approach for the stability analysis. It is shown that synchronization is achieved for the case of constant power demand, by showing that the system is exponentially stable. Furthermore, for the case of time-varying power demand, we show the error trajectories are ultimately bounded, and the synchronization error is proportional to an upper bound on the derivative of the time-varying power demand. We simulate the controller performance on a four area network which is equivalent to the IEEE New England 39-Bus system.
The Power LCA Tool shows environmental and cost results for NETL's LCAs of power systems, including fossil and wind power. In addition to reporting results for costs and emissions, it allows trade-off analysis between costs and emissions. It also allows the user to evaluate the sensitivity of results to changes in key parameters..
Isolated electrical power generating units can be used as an economically viable alternative to electrify remote villages where grid extension is not feasible. One of the options for building isolated power systems is by hybridizing renewable power sources like wind, solar, micro-hydro, etc. along with appropriate energy storage. A method to optimally size and to evaluate the cost of energy produced by a renewable hybrid system is proposed in this paper. The proposed method, which is based on the design space approach, can be used to determine the conditions for which hybridization of the system is cost effective. The simple and novel methodology, proposed in this paper, is based on the principles of process integration. It finds the minimum battery capacity when the availability and ratings of various renewable resources as well as load demand are known. The battery sizing methodology is used to determine the sizing curve and thereby the feasible design space for the entire system. Chance constrained programming approach is used to account for the stochastic nature of the renewable energy resources and to arrive at the design space. The optimal system configuration in the entire design space is selected based on the lowest cost of energy, subject to a specified reliability criterion. The effects of variation of the specified system reliability and the coefficient of correlation between renewable sources on the design space, as well as the optimum configuration are also studied in this paper. The proposed method is demonstrated by designing an isolated power system for an Indian village utilizing wind-solar photovoltaic-battery system. (author)
In isolated power systems, including microgrids, distributed assets, such as renewable energy resources (e.g. wind, solar) and energy storage, can be actively coordinated to reduce dependency on fossil fuel generation. The key challenge of such coordination arises from significant uncertainty and variability occurring at small time scales associated with increased penetration of renewables. Specifically, the problem is with ensuring economic and efficient utilization of DERs, while also meeting operational objectives such as adequate frequency performance. One possible solution is to reduce the time step at which tertiary controls are implemented and to ensure feedback and look-ahead capability are incorporated to handle variability and uncertainty. However, reducing the time step of tertiary controls necessitates investigating time-scale coupling with primary controls so as not to exacerbate system stability issues. In this paper, an optimal coordination (OC) strategy, which considers multiple time-scales, is proposed for isolated microgrid systems with a mix of DERs. This coordination strategy is based on an online moving horizon optimization approach. The effectiveness of the strategy was evaluated in terms of economics, technical performance, and computation time by varying key parameters that significantly impact performance. The illustrative example with realistic scenarios on a simulated isolated microgrid test system suggests that the proposed approach is generalizable towards designing multi-time scale optimal coordination strategies for isolated power systems.
Abstract Electric power systems are composed of physical and cyber sub‐systems. The sub‐systems depend on each other. If the cyber sub‐system is compromised by a cyber threat, what is the impact on the physical system? This paper presents a case study that shows the steps of a multi‐stage cyber threat involving a database injection attack, and what happens to the power system if this threat is not detected in its early stages. The threat first affects one utility but it can spread to the balancing authority, which is responsible for keeping the voltage and frequency stable in the power grid. During the cyber threat, the authors also show defence tools, such as a cyber‐physical data fusion tool that displays and analyses power and cyber telemetry.