At least 145 records · Page 8

Radiation Observations with Satellite 1958 Alpha Explorer I

On 1 February 1958 at 0348 U.T. earth satellite 1958 Alpha (Explorer I) was launched from Cape Canaveral. This satellite contained a Geiger Muller tube for the measurement of the flux of energetic charged particles, and detectors for determining the micrometeorite flux and satellite temperature (see Figure 1), The high power transmitter and its associated instrumentation operated until partial exhaustion of the transmitter batteries on 12 February 1958. The transmitter reappeared briefly on 24 February, The low power system operated properly until about 0700 U,T, on 16 March, at which time the batteries powering the G.M. tube circuits became exhausted. During the operating time a large amount of data was recorded by a network of seventeen receiving stations. A sampling of early recordings was reduced and analyzed as they arrived from the receiving stations. These data, in conjunction with data from the first few orbits of 1958 Gamma (Explorer III), resulted in the announcement on 1 May 1958 of the region of high intensity radiation surrounding the earth (Van Allen, 1958), The detailed, complete reduction of the 1958 Alpha data has now been completed, This paper is a tabulation of all the data received from this satellite. It consists primarily of two parts. The first part is the master recording log on which are listed all recordings of the satellite signals obtained by the receiving station network. The actual data tabulation is contained in part two.

RADIATION↗

Interactions between spacecraft and the charged-particle environment

Spacecraft-environment interactions are defined as the responses of a spacecraft surface to a charged-particle environment. This response can influence spacecraft system performance. Interactions can be divided into two broad categories: spacecraft passive, in which the environment acts on the spacecraft; and spacecraft active, in which the spacecraft causes the interaction. Passive interactions include the spacecraft-charging phenomenon. Active interactions include the relatively new interactions arising from the use of very large spacecraft and space power systems in future missions. To illustrate active interactions, a large power system operating at elevated voltages is considered. Possible interactions are described, available experimental data are reviewed, and the effect on power system performance is estimated.

Stevens, N. J.↗

Peer-to-Peer Energy Trading under Network Constraints Based on Generalized Fast Dual Ascent

We report the wide deployment of renewable energy resources, combined with a more proactive demand-side management, is inducing a new paradigm in both power system operation and electricity market trading, which especially boosts the emergence of the peer-to-peer (P2P) market. A more flexible local market mechanism is highly desirable in response to fast changes in renewable power generation at the distribution network level. Moreover, large-scale implementation of P2P energy trading inevitably affects the secure and economic operation of the distribution network. This paper presents a new P2P electricity trading framework with distribution network security constraints considered using the generalized fast dual ascent method. First, an event-driven local P2P market framework is presented to facilitate short-term or immediate local energy transactions. Then, the sensitivity analysis of nodal voltage and network loss with respect to nodal power injections is used to evaluate the impacts of P2P transactions on the distribution network, which ensures the secure operation of the distribution system. Thereby, the external operational constraints are internalized, and the cost of P2P energy trading can be appropriately allocated in an endogenous way. Moreover, a generalized fast dual ascent method is employed to implement distributed market-clearing efficiently. Finally, numerical results indicate that the proposed model could guarantee secure operation of the distribution system with P2P energy trading, and the solution method enjoys good convergence performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Entropy-Infused Deep Learning Loss Function for Capturing Extreme Values in Wind Power Forecasting

Extreme scenarios in wind power generation occur with higher frequency and larger magnitude in the recent years due to the ever-increasing extreme meteorological factors. Accurate forecasting of the occurrence of extreme values in wind power generation is of great concern to ensure reliable power system operation. Recently, deep learning models have surged in popularity for wind power forecasting, with the mean squared error (MSE) loss function being commonly used. However, the MSE loss function, being sensitive to extreme values, disproportionately penalizes larger errors, cannot adequately capture the extreme values present in wind energy data, and novel loss functions have seldom been tailored for wind power forecasting. To this end, in this paper, we introduce a novel loss function specifically crafted to capture extreme values in wind power forecasting. The experimental results with four fundamental deep learning methods on open source wind power dataset validate that the new loss function is efficient and superior in all cases compared to MSE in capturing extreme values while maintaining forecasting performance.

17 WIND ENERGY↗

Power System Wildfire Risks and Potential Solutions: A Literature Review & Proposed Metric

Several fire risk evaluation, fire tracking, and fire response resources are available. The risk metrics and fire response programs are sometimes modified to include a power system context. The risk metrics often evaluate the risk of fires causing power system faults or outages, especially on transmission systems. The response programs are modified to ensure the safety of power system equipment and first responders as well as to coordinate power system outages to both ensure safety during an active fire and prevent fire ignition during high risk periods. Although some aspects of wildfire responses have been adapted to include power system concerns, adaptations to power system operations and maintenance to include wildfire risks and responses are still nascent. In particular, a risk metric that evaluates the potential for power system components to ignite wildfires is needed to help guide power system upgrade efforts and power system fire safety measures. This document serves as a brief literature review of wildfire risk metrics and response programs and how they relate to power systems. It also includes a proposed risk metric and structure for describing the risk of a power system component igniting a fire.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar bus regulator and battery charger for IMP's H, I, and J

Interplanetary Monitoring Probe (IMP) spacecrafts H, I, and J utilize a direct energy transfer (DET) type of power system operating from a solar array source. A shunt type of regulator prevents the bus voltage from exceeding a preset voltage level. The power system utilizes a single differential amplifier with dual outputs to control the battery charge/shunt regulator and the discharge regulator. A two-voltage level, current limited, series charger and a current sensor control battery state of charge of the silver-cadmium battery pack. Premature termination of the battery charge is prevented by a power available gate that also initiates charge current to the battery upon availability of excess power.

Paulkovich, J.↗

Substation-Level Grid Topology Optimization Using Bus Splitting

Operations of substation circuit breakers are important for maintenance needs and topology reconfiguration in power systems. Bus splitting is one type of topology change where the two bus bars at a substation can become electrically disconnected under certain actions of circuit breakers. Because these events involve detailed substation modeling, they are typically not considered in routine power system operation and control. In this paper, an improved substation-level topology optimization framework is developed by expanding traditional line switching decisions by breaker-level bus splitting, which can further reduce grid congestion and generation costs. A tight McCormick relaxation is proposed to reformulate the bilinear terms in the resultant optimization problem to linear inequality constraints. Thus, a tractable mixed-integer linear program reformulation is attained that allows for efficient solutions in real-time operations. Numerical studies on the IEEE 14-bus and 118-bus systems demonstrate the computational performance and economic benefits of the proposed topology optimization approach.

bus split↗

Increasing Importance of Material Electrical Interaction with the Space Environment

The electrical properties of materials have always been important for spacecraft in charging environments. However, in recent years consideration of interactions of materials and systems with the plasma environment has become more and more important in spacecraft design. This has primarily been driven by independent factors including increase in power and high voltage power systems, operation of tethered satellites, and science requirements for electrostatic clean spacecraft. Increased need for power has led to increased operating voltages for spacecraft. The Upper Atmospheric Research Satellite (UARS) was one of the first to operate at near 100 V solar array potential and demonstrate that the spacecraft floated nearly the entire voltage negative of the ionospheric plasma. The high voltage, 160 V, of the solar arrays on the International Space Station (ISS) led to the requirement to have a plasma contactor to control structure potential relative to the local plasma. Issues such as sputtering, dielectric breakdown, capacitive energy storage in the structure, space debris impact induced arcs and other arcing mechanisms had to be addressed. Recently commercial satellites, driven to higher voltages for efficiency, have experienced arcing problems which led to severe, permanent power degradation. The first tethered satellite, Tethered Satellite System (TSS), was deployed from the Space Shuttle. A conductive coating was developed which provided a low resistivity and also the required solar absorptivity and emittance. Other tether systems are being designed which will have similar requirements but also long life and "bare tether" designs are also being built for flight experiments. The wire requires an electrically conductive coating with proper thermal control properties, which a bare wire doesn't possess. Increasing sophistication of scientific instruments and measurements which scientists want to make have led to increasing requirements for conducting thermal control coatings to provide electrostatic cleanliness. These issues, which are increasing the importance of electrical interaction of materials to the space environment, will be discussed in this paper as well as research into material development to meet thermal and electrical requirements and research to understand phenomena regarding such interactions.

Carruth, M. R., Jr.↗

Opportunities for Renewable Energy, Storage, Vehicle Electrification, and Demand Response in Rajasthan's Power Sector

To support the government of Rajasthan and inform state policy makers, regulators, planners, and system operators on power system trends, NREL undertook a long-term capacity expansion planning study. We used NREL's flagship capacity expansion planning tool for the power sector called the Regional Energy Deployment System India (ReEDS-India) to understand the generation and transmission needs of Rajasthan through 2050. NREL's modeling framework includes co-optimized decisions about generation, energy storage, transmission, and reserves investments needed to meet future demand while maintaining reliable electricity supply. Scenario analysis was conducted to assess a range of potential future scenarios, providing insight for planning agencies, utilities, and local stakeholders about key trends and sources of uncertainty.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ionospheric disturbance overview

A program of research and exploratory development was undertaken to assess the potential impact of Satellite Power System operation on the ionosphere. The program relies on the utilization of ground-based ionospheric heating facilities in order to simulate the ionospheric heating that will come from the Satellite Power System. Thus far, the experimental program directed toward assessing telecommunications impacts has received the most attention, and little impact was observed on VLF, LF, and MF operations.

Rush, C. M.↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on the Banshee Distribution Network: Preprint

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on Banshee Distribution Network

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Research Priorities and Opportunities in United States Wholesale Electricity Markets

The power system is currently undergoing a number of changes, including a rapidly evolving resource mix, growth of distributed energy resources (DERs), more active consumer participation, increased deployment of energy storage and hybrid resources, and more advanced communication and control requirements. These changes in the power system present numerous technical, economic, implementation, and policy challenges and research opportunities for power system operators. To help address these challenges, a collaboration among five research institutions—Argonne National Laboratory, the National Renewable Energy Laboratory, Lawrence Berkeley National Laboratory, the Electric Power Research Institute, and Johns Hopkins University—has been established to provide technical assistance to the seven U.S. Independent System Operators (ISOs) and Regional Transmission Organizations (RTOs). The 3-year project aims to leverage the advanced methods, tools, datasets, and resources of the collaborators to provide robust analytical support to address the high-priority market challenges that will be faced in the 2- to 10-year time horizon.