SEARCH · Engineering Papers
Results for “Power Measurements”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A Data-Driven Method for Estimating Behind-the-Meter Photovoltaic Generation in Hawaii
Due to the increasing penetration of distributed behind-the-meter photovoltaic (PV) systems and the installed utility revenue metering limited to monitoring only the net power import/export of the household, it is increasingly challenging for utilities to effectively plan and operate the grid. This paper proposes a methodology that estimates behind-the-meter PV generation using a selected subset of monitored PV systems. It is a data-driven approach, and the PV output is estimated utilizing a statistic regression model. A Minimum Redundancy Maximum Relevance (MRMR) algorithm is applied to preselect the optimal subset of the monitored PV systems. The performance of this approach is compared with a spatial interpolation method and a model-based approach. The proposed method is validated using high-resolution meter data recorded from 18 residential rooftop PV systems located on the island of Maui, Hawaii.
Quantifying Energy Justice Goals in the Power Sector: Developing and Using Metrics
New policy goals are explicitly guiding the future grid toward greater energy equity. At the same time, policy goals also guide the grid toward decarbonization and resilience, while maintaining cost, security, and reliability cornerstone requirements. In conclusion, these pressures create a dilemma: moving urgently to address climate change and respond to energy disruptions, but also slowly to engage communities on the climate frontlines in earnest.
Detailed Primary and Secondary Distribution System Model Enhancement Using AMI Data
Not Available
The completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: BAO and RSD measurements from the anisotropic power spectrum of the quasar sample between redshift 0.8 and 2.2
ABSTRACT We measure the clustering of quasars of the final data release (DR16) of eBOSS. The sample contains $343\, 708$ quasars between redshifts 0.8 ≤ z ≤ 2.2 over $4699\, \mathrm{deg}^2$. We calculate the Legendre multipoles (0,2,4) of the anisotropic power spectrum and perform a BAO and a Full-Shape (FS) analysis at the effective redshift zeff = 1.480. The errors include systematic errors that amount to 1/3 of the statistical error. The systematic errors comprise a modelling part studied using a blind N-body mock challenge and observational effects studied with approximate mocks to account for various types of redshift smearing and fibre collisions. For the BAO analysis, we measure the transverse comoving distance DM(zeff)/rdrag = 30.60 ± 0.90 and the Hubble distance DH(zeff)/rdrag = 13.34 ± 0.60. This agrees with the configuration space analysis, and the consensus yields: DM(zeff)/rdrag = 30.69 ± 0.80 and DH(zeff)/rdrag = 13.26 ± 0.55. In the FS analysis, we fit the power spectrum using a model based on Regularised Perturbation Theory, which includes redshift space distortions and the Alcock–Paczynski effect. The results are DM(zeff)/rdrag = 30.68 ± 0.90 and DH(zeff)/rdrag = 13.52 ± 0.51 and we constrain the linear growth rate of structure f(zeff)σ8(zeff) = 0.476 ± 0.047. Our results agree with the configuration space analysis. The consensus analysis of the eBOSS quasar sample yields: DM(zeff)/rdrag = 30.21 ± 0.79, DH(zeff)/rdrag = 3.23 ± 0.47, and f(zeff)σ8(zeff) = 0.462 ± 0.045 and is consistent with a flat ΛCDM cosmological model using Planck results.
Factorization for azimuthal asymmetries in SIDIS at next-to-leading power
Differential measurements of the semi-inclusive deep inelastic scattering (SIDIS) process with polarized beams provide important information on the three-dimensional structure of hadrons. Among the various observables are azimuthal asymmetries that start at subleading power, and which give access to novel transverse momentum dependent distributions (TMDs). Theoretical predictions for these distributions are currently based on the parton model rather than a rigorous factorization based analysis. Working under the assumption that leading power Glauber interactions do not spoil factorization at this order, we use the Soft Collinear Effective Theory to derive a complete factorization formula for power suppressed hard scattering effects in SIDIS. This yields generalized definitions of the TMDs that depend on two longitudinal momentum fractions (one of them only relevant beyond tree level), and a complete proof that only the same leading power soft function appears and can be absorbed into the TMD distributions at this order. We also show that perturbative corrections can be accounted for with only one new hard coefficient. Factorization formulae are given for all spin dependent structure functions which start at next-to-leading power. Prospects for improved subleading power predictions that include resummation are discussed.
Elevated levels of radiocarbon in methane dissolved in seawater reveal likely local contamination from nuclear powered vessels
Measurements of the natural radiocarbon content of methane ( 14 C-CH 4 ) dissolved in seawater and freshwater have been used to investigate sources and dynamics of methane. However, during investigations along the Atlantic, Pacific, and Arctic Ocean Margins of the United States, as well as in the North American Great Lakes, some samples revealed highly elevated 14 C-CH 4 values, as much as 4–5 times above contemporary atmospheric 14 C-CH 4 levels. Natural production of the 14 CH 4 isotopologue is too low to cause these observations nor can it explain the variations in location and depth. Numerous lab and field validation tests and blanks, as well as the relatively small number of samples that display these elevated values, all suggest that these signals are not derived from an unknown procedural issue. Here, in this work, we suggest that the byproducts of nuclear power generation include localized discharges of the 14 CH4 isotopologue into marine and aquatic environments, severely altering the measured 14 C-CH 4 isotopic signals. Since several of our sample sites are distant from on-land nuclear powerplants, we conduct further calculations concluding that the most elevated anomalies in 14 C-CH 4 likely originate with discharge from nuclear-powered vessels.
Regional inertia dynamics of U.S. interconnections: An event-based measurement approach
Power grid inertia plays a vital role in frequency stability following large disturbances, yet its distribution across the U.S. grid is highly uneven. While interconnection-wide inertia benchmarks are useful, they can mask regional variability driven by resource mix, network coupling, and geographic separation. This paper extends event-driven inertia estimation to the regional scale using field measurements from the Frequency Monitoring Network (FNET/GridEye). Starting from balancing authority and independent system operator footprints, candidate regions are refined using a composite coherency score that combines frequency-trajectory shape similarity, timing spread, and lead/lag behavior to ensure dynamic consistency. A filtered sliding difference method (FSDM) is then used to construct regional frequency trajectories, detect disturbance onset, and compute robust regional rate-of-change of frequency (RoCoF). Regional, local, and interconnection inertia are estimated by combining RoCoF with event power imbalance, and additional indicators (regional-to-system inertia ratio and inertial-support arrival time) quantify regional-to-interconnection coupling and relative regional contributions. The method is demonstrated on eleven regions across the Eastern Interconnection (EI) and the Western Electricity Coordinating Council (WECC), with the Electric Reliability Council of Texas (ERCOT) used for validation. In ERCOT, estimates compared against energy management system (EMS) values achieve a mean absolute percentage error of 17.94%. WECC exhibits consistently shorter inertial-support arrival times (0.15–0.3 s) than EI (0.7–1.1 s), highlighting contrasting coupling and disturbance-propagation behavior. Overall, the results reveal pronounced spatial heterogeneity in inertia and coupling, underscoring the value of regional monitoring for both operational decision-making and long-term system planning.
Unified and Consistent Structure Growth Measurements from Joint ACT, SPT, and Planck CMB Lensing
We present the tightest cosmic microwave background (CMB) lensing constraints to date on the growth of structure by combining CMB lensing measurements from the Atacama Cosmology Telescope (ACT), the South Pole Telescope (SPT), and Planck. Each of these surveys individually provides lensing measurements with similarly high statistical power, achieving signal-to-noise ratios of approximately 40. The combined lensing band powers represent the most precise CMB lensing power spectrum measurement to date with a signal-to-noise ratio of 61 and an amplitude of A lens recon = 1.025 ± 0.017 with respect to the theory prediction from the best-fit CMB Planck-ACT cosmology. The band powers from all three lensing datasets, analyzed jointly, yield a 1.6% measurement of the parameter combination S 8 CMBL ≡ σ 8 ( Ω m / 0.3 ) 0.25 = 0.82 5 - 0.013 + 0.015 . Including dark energy spectroscopic instrument baryon acoustic oscillation (BAO) data improves the constraint on the amplitude of matter fluctuations to σ 8 = 0.829 ± 0.009 (a 1.1% determination). When combining with uncalibrated supernovae from Pantheon+, we present a 4% sound-horizon-independent estimate of H 0 = 66.4 ± 2.5 km s - 1 Mpc - 1 . The joint lensing constraints on structure growth and present-day Hubble rate are fully consistent with a Λ CDM model fit to the primary CMB data from Planck and ACT. While the precise upper limit is sensitive to the choice of data and underlying model assumptions, when varying the neutrino mass sum within the Λ CDM cosmological model, the combination of primary CMB, BAO, and CMB lensing drives the probable upper limit for the mass sum towards lower values, comparable to the minimum mass prior required by neutrino oscillation experiments.
Analysis of Lobe Power Calculator and Indication System with Physics and Cycle Based Models
The Advanced Test Reactor (ATR) at INL measures reactor power through various methods, two of them being thermal and Nitrogen-16 (N-16) activity. Water power calculator (WPC) is a thermal power system that measures flow and temperature to determine thermal quadrant powers. The N-16 system utilizes a beta detector that outputs Nitrogen activation levels to calculate lobe power through an algorithm called Lobe Power Calculation and Indication system (LPCIS). The LPCIS utilizes the N-16 system and the WPC system to determine reactor core power levels. The WPC provides accurate calculations of quadrant and total reactor thermal power. With the use of WPC measurements, thermal-to-N-16 (T2N) power ratios are produced to determine if the two indication systems agree on core power. Relative magnitude equations are used to utilize N-16 coefficients and multipliers to improve the indications of the LPCIS. These correct indications are crucial for maintaining safety limits because operators rely on this information for decision making. Currently, the LPCIS system uses linear equations and matrices to calculate lobe power through multipliers and coefficients. Advancements in technology and system upgrades have increased the accuracy of power readings by making the system more dynamic. The new proposed coefficient and multiplier method implements a cycle specific and physics-based model intended for changing coefficients during operation. This calibration experiment focused on power splitting, outer shim and neck shim, as well as fuel burning into the reactor digital acquisition system (RDAS) weighting factors. Results demonstrated that the physics learning method yields a smaller error margin inside of the desired power range for the data set 166-A. Continuing to improve the physics-based model will help improve the power accuracy of the LPCIS system.
Frequency Response Analysis to Monitor and Identify Changes in the Impedance of a Photovoltaic Panel Measured Online using a Power Optimizer
Photovoltaic (PV) cells are generally modeled as a current source due to photocurrent, p-n junction diodes with parasitic resistance, capacitance, and inductance. This paper proposes online frequency response analysis (FRA) to measure the impedance of a PV panel using an existing panel-level power optimizer in a PV system. The algorithm will actively perturb a small signal into a 300 W rooftop PV panel and compute its small signal impedance. The technology discussed is easy to incorporate, requires no additional hardware, doesn't alter the stability of the system, and is implemented at a steady-state point. The power optimizer initially stabilizes at an operating point and then perturbs the PV current via FRA and computes PV panel impedance. The relative standard deviation test conducted indoors under 300 W/m 2 illumination on a PV panel shows a less than 5% error rate in PV panel impedance magnitude and phase is measured using a power optimizer.
Analysis of Lobe Power Calculator and Indication System with Physics and Cycle Based Models
The Advanced Test Reactor (ATR) at INL measures reactor power through two methods, thermal and Nitrogen-16 (N-16) activity. Water power calculator (WPC) is a thermal power system that measures flow and temperature to determine the thermal quadrant powers. The N-16 system utilizes a beta chamber detector that outputs reactivity levels to calculate lobe power through an algorithm called lobe power calculation and indication system (LPCIS). The LPCIS utilizes the N-16 system and the WPC system to determine reactor core power levels. The WPC provides accurate calculations of quadrant and total reactor thermal power. With the use of WPC measurements, thermal-to-N-16 (T2N) power ratios are produced to determine if the two indication systems agree on core power. Relative magnitude equations are used to utilize N-16 coefficients and multipliers to improve the indications of the LPCIS. This is crucial for maintaining safety limits. Currently, the LPCIS system uses linear equations and matrices to calculate lobe power through multipliers and coefficients. Advancements in technology and system upgrades have assisted system engineers at INL with the objective to reach a more dynamic system. In return the system demonstrates an increase in the accuracy of power reading while maintaining safety margins. The new proposed coefficient and multiple method implements a cycle specific, and a physics-based model intended for changing coefficients during operation. This calibration experiment focuses on power splitting, outer shim and neck shim, as well as fuel burning into the RDAS weighting factors. Results show that the Physics learning method yields a smaller error margin inside of the desired power range for the data set 166-A. This proved true for both constrained and unconstrained testing. This is most likely due to the physics data fitting approach that resulted in favorable coefficients and multipliers for 166-A. Continuing to improve the physics-based model will help improve the power accuracy of the LPCIS system.
Reactor Power Level Estimation by Fusing Multi-Modal Sensor Measurements
Estimates of the power level of a nuclear reactor based on measurements from an independent monitoring sensor system can help in the compliance verification of its declared operations. We present a three-level fusion method to estimate the power level of a nuclear reactor using features derived from infrared, electromagnetic, and acoustic sensor measurements collected in proximity to the reactor. Based on a simplified analytical model of the secondary coolant system of the reactor, we identify partial regression functions of the power level in terms of the temperature difference between inlet and outlet of coolant pipes, and the activity levels of four fans and four pumps, which are estimated as features from the sensor measurements. The power level estimator employs a combination of aggregate and complementary fusion steps at three levels to incorporate the multi-modal features in a structure that reflects the secondary cooling system and its partial regression functions. Using the measurements from a test campaign at an operational reactor, we show that this estimator achieves 3.47% or lower root mean square error under 5-fold cross validation. More generally, these results illustrate a progressive reduction in estimation error as additional modalities are appropriately incorporated, and that the fuser outperforms single modality features and their sub-combinations.
Transverse Beam Emittance Measurement by Undulator Radiation Power Noise
Generally, turn-to-turn power fluctuations of incoherent spontaneous synchrotron radiation in a storage ring depend on the 6D phase-space distribution of the electron bunch. In some cases, if only one parameter of the distribution is unknown, this parameter can be determined from the measured magnitude of these power fluctuations. In this contribution, we report the results of our experiment at the Integrable Optics Test Accelerator (IOTA) storage ring, where we carried out an absolute measurement (no free parameters or calibration) of a small vertical emittance (5–15 nm rms) of a flat beam by this new method, under conditions, when the small vertical emittance is unresolvable by a conventional synchrotron light beam size monitor.
Hyper Suprime-Cam Year 3 results: Cosmology from cosmic shear power spectra
Here, we measure weak lensing cosmic shear power spectra from the 3-year galaxy shear catalog of the Hyper Suprime-Cam (HSC) Subaru Strategic Program imaging survey. The shear catalog covers 416 deg 2 of the northern sky, with a mean i-band seeing of 0.59 arcsec and an effective galaxy number density of 15 arcmin —2 within our adopted redshift range. With an i-band magnitude limit of 24.5 mag, and four tomographic redshift bins spanning 0.3 ≤ z ph ≤ 1.5 based on photometric redshifts, we obtain a high-significance measurement of the cosmic shear power spectra, with a signal-to-noise ratio of approximately 26.4 in the multipole range 300 < ℓ < 1800. The accuracy of our power spectrum measurement is tested against realistic mock shear catalogs, and we use these catalogs to get a reliable measurement of the covariance of the power spectrum measurements. We use a robust blinding procedure to avoid confirmation bias, and model various uncertainties and sources of bias in our analysis, including point spread function systematics, redshift distribution uncertainties, the intrinsic alignment of galaxies and the modeling of the matter power spectrum. For a flat Λ CDM model, we find S 8 ≡ σ 8 (Ω m /0.3) 0.5 = ${0.776}_{—0.033}^{+0.032}$, which is in excellent agreement with the constraints from the other HSC Year 3 cosmology analyses, as well as those from a number of other cosmic shear experiments. This result implies a ~2σ-level tension with the Planck 2018 cosmology. We study the effect that various systematic errors and modeling choices could have on this value, and find that they can shift the best-fit value of S 8 by no more than ~ 0.5σ, indicating that our result is robust to such systematics.
Unified and consistent structure growth measurements from joint ACT, SPT and \textit{Planck} CMB lensing
We present the tightest cosmic microwave background (CMB) lensing constraints to date on the growth of structure by combining CMB lensing measurements from the Atacama Cosmology Telescope (ACT), the South Pole Telescope (SPT) and \textit{Planck}. Each of these surveys individually provides lensing measurements with similarly high statistical power, achieving signal-to-noise ratios of approximately 40. The combined lensing bandpowers represent the most precise CMB lensing power spectrum measurement to date with a signal-to-noise ratio of 61 and an amplitude of $A_\mathrm{lens}^\mathrm{recon} = 1.025 \pm 0.017$ with respect to the theory prediction from the best-fit CMB \textit{Planck}-ACT cosmology. The bandpowers from all three lensing datasets, analyzed jointly, yield a $1.6\%$ measurement of the parameter combination $S_8^\mathrm{CMBL} \equiv σ_8\,(Ω_m/0.3)^{0.25} = 0.825^{+0.015}_{-0.013}$. Including Dark Energy Spectroscopic Instrument (DESI) Baryon Acoustic Oscillation (BAO) data improves the constraint on the amplitude of matter fluctuations to $σ_8 = 0.829 \pm 0.009$ (a $1.1\%$ determination). When combining with uncalibrated supernovae from \texttt{Pantheon+}, we present a $4\%$ sound-horizon-independent estimate of $H_0=66.4\pm2.5\,\mathrm{km\,s^{-1}\,Mpc^{-1}} $. The joint lensing constraints on structure growth and present-day Hubble rate are fully consistent with a $Λ$CDM model fit to the primary CMB data from \textit{Planck} and ACT. While the precise upper limit is sensitive to the choice of data and underlying model assumptions, when varying the neutrino mass sum within the $Λ\mathrm{CDM}$ cosmological model, the combination of primary CMB, BAO and CMB lensing drives the probable upper limit for the mass sum towards lower values, comparable to the minimum mass prior required by neutrino oscillation experiments.
HIDES: Hybrid Intrusion Detector for Energy Systems
The establishment of a resilient electric grid accompanied by a secure communications network is an ongoing battle as advanced persistent threats continue to exploit existing vulnerabilities in legacy supervisory control and data acquisition system (SCADA) infrastructure. Traditional intrusion detection systems (IDSs) lack consistent performance because of the continuously evolving attack surface of SCADA systems. These shortcomings can be overcome by integrating logical system behavior, protocol-specific knowledge, and data-based learning to develop a comprehensive IDS solution. In this paper, we present a Hybrid Intrusion Detector for Energy Systems by integrating a network-based IDS, state-of-the-art machine learning-based IDS, and model-based IDS to detect unknown and stealthy cyberattacks targeting the SCADA networks. The proposed IDS uses synchrophasor measurements and cyber logs to learn patterns of different scenarios based on spatiotemporal behaviors of power systems. As a proof of concept, we implement and validate the proposed IDS by leveraging resources available at the National Renewable Energy Laboratory's Energy Systems Integration Facility test bed. Experimental results show promising performance in detecting cyberattacks while providing realtime visualization of power system measurements and cyber logs.
Intensity Modulated Fiber Optic Sensor: A Novel Grid Measurement Unit
This paper presents a novel approach to physical displacement-based power grid measuring via an Intensity Modulated Fiber Optic Sensor (IMFOS). An IMFOS utilizes one fiber to transmit the intensity modulation light from its Electro-Optic controller to a fiber optic probe. The power grid voltage and current can induce physical displacements in transducers via the piezoelectric effect and the Lorentz law, respectively, which then result in a distance change between the optical probe and the reflective surface of the transducers. In parallel, multiple fibers are used to collect the reflective light for electro-optic conversion. Furthermore, a National Instruments-based characterization platform is set up for performance evaluation. Here, the testing result demonstrates that the IMFOS is immune to the inherent DC and low-frequency saturation issues prevalent in conventional potential and current transformers. Finally, the IMFOS is implemented in a Universal Grid Analyzer to illustrate its applicability for phasor estimation in actual power grids.