Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Subsecond and Submillimeter Resolution Positional Verification for Stereotactic Irradiation of Spinal Lesions

Purpose: Spine stereotactic body radiation therapy (SBRT) requires highly accurate positioning. We report our experience with markerless template matching and triangulation of kilovoltage images routinely acquired during spine SBRT, to determine spine position. Methods and Materials: Kilovoltage images, continuously acquired at 7, 11 or 15 frames/s during volumetric modulated spine SBRT of 18 patients, consisting of 93 fluoroscopy datasets (1 dataset/arc), were analyzed off-line. Four patients were immobilized in a head/neck mask, 14 had no immobilization. Two-dimensional (2D) templates were created for each gantry angle from planning computed tomography data and registered to prefiltered kilovoltage images to determine 2D shifts between actual and planned spine position. Registrations were considered valid if the normalized cross correlation score was ≥0.15. Multiple registrations were triangulated to determine 3D position. For each spine position dataset, average positional offset and standard deviation were calculated. To verify the accuracy and precision of the technique, mean positional offset and standard deviation for twenty stationary phantom datasets with different baseline shifts were measured. Results: For the phantom, average standard deviations were 0.18 mm for left-right (LR), 0.17 mm for superior-inferior (SI), and 0.23 mm for the anterior-posterior (AP) direction. Maximum difference in average detected and applied shift was 0.09 mm. For the 93 clinical datasets, the percentage of valid matched frames was, on average, 90.7% (range: 49.9-96.1%) per dataset. Average standard deviations for all datasets were 0.28, 0.19, and 0.28 mm for LR, SI, and AP, respectively. Spine position offsets were, on average, −0.05 (range: −1.58 to 2.18), −0.04 (range: −3.56 to 0.82), and −0.03 mm (range: −1.16 to 1.51), respectively. Average positional deviation was <1 mm in all directions in 92% of the arcs. Conclusions: Template matching and triangulation using kilovoltage images acquired during irradiation allows spine position detection with submillimeter accuracy at subsecond intervals. Although the majority of patients were not immobilized, most vertebrae were stable at the sub-mm level during spine SBRT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Position Index of Overhead LED Sources Under Different Spectral Power Distributions and Background Luminances

The position index was developed by Luckiesh and Guth in 1949 and is widely used in discomfort glare models to account for the position of the glare source when predicting the presence and magnitude of visual discomfort. The applicability of this index to modern LED sources has not been evaluated; however, it is of concern due to potentially higher luminance levels of LEDs compared to the sources used by Luckiesh and Guth. Furthermore, the position index of overhead sources beyond 60° above the line of sight has not been quantified. An experiment was conducted using a hemispherical apparatus with LED sources. The position of the light source, background luminance, the spectral power distribution, and anchor (starting luminance level before adjustment) were varied and two procedures were used to determine the position index of these sources. Data from 29 participants indicate that overhead sources located 60° or 80° above the line of sight were detectable and their position index can be quantified. The position index values were found to be higher than those reported in previous studies, suggesting that anchor bias and the small luminance range in previous studies likely influenced their position index values. No differences were found in position index values by spectral power distribution, background luminance, participant age group, or eyeglass wearing. In conclusion, the position index values reported in this study account for range and anchor bias, providing a better estimate that should be incorporated into discomfort glare models.

Discomfort glare↗

SU-F-J-25: Position Monitoring for Intracranial SRS Using BrainLAB ExacTrac Snap Verification

Purpose: To determine the accuracy of position monitoring with BrainLAB ExacTrac snap verification following couch rotations during intracranial SRS. Methods: A CT scan of an anthropomorphic head phantom was acquired using 1.25mm slices. The isocenter was positioned near the centroid of the frontal lobe. The head phantom was initially aligned on the treatment couch using cone-beam CT, then repositioned using ExacTrac x-ray verification with residual errors less than 0.2mm and 0.2°. Snap verification was performed over the full range of couch angles in 15° increments with known positioning offsets of 0–3mm applied to the phantom along each axis. At each couch angle, the smallest tolerance was determined for which no positioning deviation was detected. Results: For couch angles 30°–60° from the center position, where the longitudinal axis of the phantom is approximately aligned with the beam axis of one x-ray tube, snap verification consistently detected positioning errors exceeding the maximum 8mm tolerance. Defining localization error as the difference between the known offset and the minimum tolerance for which no deviation was detected, the RMS error is mostly less than 1mm outside of couch angles 30°–60° from the central couch position. Given separate measurements of patient position from the two imagers, whether to proceed with treatment can be determined by the criterion of a reading within tolerance from just one (OR criterion) or both (AND criterion) imagers. Using a positioning tolerance of 1.5mm, snap verification has sensitivity and specificity of 94% and 75%, respectively, with the AND criterion, and 67% and 93%, respectively, with the OR criterion. If readings exceeding maximum tolerance are excluded, the sensitivity and specificity are 88% and 86%, respectively, with the AND criterion. Conclusion: With a positioning tolerance of 1.5mm, ExacTrac snap verification can be used during intracranial SRS with sensitivity and specificity between 85% and 90%.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-05: Geometry Based Transperineal Ultrasound Probe Positioning for Image Guided Radiotherapy

Purpose: The use of ultrasound (US) imaging in radiotherapy is not widespread, primarily due to the need for skilled operators performing the scans. Automation of probe positioning has the potential to remove this need and minimize operator dependence. We introduce an algorithm for obtaining a US probe position that allows good anatomical structure visualization based on clinical requirements. The first application is on 4D transperineal US images of prostate cancer patients. Methods: The algorithm calculates the probe position and orientation using anatomical information provided by a reference CT scan, always available in radiotherapy workflows. As initial test, we apply the algorithm on a CIRS pelvic US phantom to obtain a set of possible probe positions. Subsequently, five of these positions are randomly chosen and used to acquire actual US volumes of the phantom. Visual inspection of these volumes reveal if the whole prostate, and adjacent edges of bladder and rectum are fully visualized, as clinically required. In addition, structure positions on the acquired US volumes are compared to predictions of the algorithm. Results: All acquired volumes fulfill the clinical requirements as specified in the previous section. Preliminary quantitative evaluation was performed on thirty consecutive slices of two volumes, on which the structures are easily recognizable. The mean absolute distances (MAD) between actual anatomical structure positions and positions predicted by the algorithm were calculated. This resulted in MAD of 2.4±0.4 mm for prostate, 3.2±0.9 mm for bladder and 3.3±1.3 mm for rectum. Conclusion: Visual inspection and quantitative evaluation show that the algorithm is able to propose probe positions that fulfill all clinical requirements. The obtained MAD is on average 2.9 mm. However, during evaluation we assumed no errors in structure segmentation and probe positioning. In future steps, accurate estimation of these errors will allow for better evaluation of the achieved accuracy.

60 APPLIED LIFE SCIENCES↗

Outcomes of Post Mastectomy Radiation Therapy in Patients Receiving Axillary Lymph Node Dissection After Positive Sentinel Lymph Node Biopsy

Purpose: We sought to determine the rate of postmastectomy radiation therapy (PMRT) among women treated with axillary lymph node dissection (ALND) after positive sentinel lymph node (SLN) biopsy results and to establish the effect of negative ALND results and PMRT on locoregional recurrence (LRR) and overall survival (OS). Methods and Materials: All patients were treated with mastectomy and ALND after positive SLN biopsy results. All patients had clinical N0 or NX disease at the time of mastectomy and received no neoadjuvant therapy. The presence of lymphovascular space invasion, presence of multifocality, number of positive SLNs and non-SLNs, clinical and pathologic stage, extranodal extension, age, and use of PMRT were evaluated for significance regarding the rates of OS and LRR. Results: A total of 345 patients were analyzed. ALND after positive SLN biopsy results was negative in 235 patients (68.1%), and a total of 112 patients (32.5%) received radiation therapy. On multivariate analysis, only pathologic stage III predicted for lower OS (hazard ratio, 3.32; P<.001). The rate of 10-year freedom from LRR was 87.9% and 95.3% in patients with positive ALND results and patients with negative ALND results, respectively. In patients with negative ALND results with ≥3 positive SLNs, the rate of freedom from LRR was 74.7% compared with 96.7% in those with <3 positive SLNs (P=.009). In patients with negative ALND results, ≥3 positive SLNs predicted for an increase in LRR on multivariate analysis (hazard ratio, 10.10; P=.034). Conclusions: A low proportion of cT1-2, N0 patients with positive SLNs who undergo mastectomy receive PMRT after ALND. Even in this low-risk cohort, patients with ≥3 positive SLNs and negative ALND results are at increased risk of LRR and may benefit from PMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Positive Charge in the Outer Coordination Sphere of an Artificial Enzyme Increases CO 2 Hydrogenation

The protein scaffold around the active site of enzymes is known to influence catalytic activity, but specific scaffold features responsible for favorable influences are often not known. This study focuses on using an artificial metalloenzyme to probe one specific feature of the scaffold, the position of a positive charge in the outer coordination sphere around the active site. Previous work showed that a small molecular complex, [Rh(P Et 2 N glycine P Et 2 )2 ] – , immobilized covalently within a protein scaffold was activated for CO 2 hydrogenation. In this work, using an iterative design where the effect of arginine, histidine, or lysine residues placed in the outer coordination sphere of the catalytic active site were evaluated, we tested the hypothesis that positively charged groups facilitate CO 2 hydrogenation with seven unique constructs. Single-, double-, and triple-point mutations were introduced to directly compare catalytic activity, as monitored by turnover frequencies (TOFs) measured in real time with 1 H NMR spectroscopy, and evaluate related structural and electronic properties. Two of the seven constructs showed a 2- and 3-fold increase relative to the wild type, with overall rates ranging from 0.2 to 0.7 h –1 , and a crystal structure of the fastest of these shows the positive charge positioned next to the active site. A crystal structure of the arginine-containing complex shows that the arginines are positioned near the metal. Molecular dynamics (MD) studies also suggest that the positive charge is oriented next to the active site in the two constructs with faster rates but not in the others and that the positive charge near the active site holds the CO 2 near the metal, all consistent with a positive charge appropriately positioned in the scaffold benefiting catalysis. The MD studies also suggest that changes in the water distribution around the active site may contribute to catalytic activity, while modest structural changes and movement of the complex within the scaffold do not.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-33: An EPID-Based Method for Testing Absolute Leaf Position for MLC Without Backup Jaws

Purpose: Methods in common use for MLC leaf position QA are limited to measurements relative to an arbitrary reference position. The authors previously presented an EPID-based method for efficiently testing accuracy of leaf position relative to the mechanical isocenter for MLC with backup jaws. The purpose of this work is to extend that method to the general case of MLC without backup jaws. Methods: A pair of collimator walkout images is used to determine the location of the mechanical isocenter relative to the center of one field using a parameter called X-offset. The method allows for shift of the imager panel to cover subsets of MLC leaves within the limited field of view of the imager. For a shifted panel position, an image of three beam strips defined by a subset of MLC leaves allows determination of the position of each leaf relative to the isocenter. The location of the isocenter is determined by applying X-offset to an image of a single rectangular field obtained at that panel position. The method can also be used to test backup jaws instead of MLC leaves. A software tool was developed to efficiently analyze the images. Results: The software tool reports leaf position and deviation from nominal position, and provides visual displays to facilitate rapid qualitative interpretation. Test results using this method agree well with results using the previous method requiring backup jaws. Test results have been successfully used to recalibrate one model MLC (Elekta MLCi2™). Work in progress includes extension of the software tool to other MLC models, and quantification of reproducibility of the measurements. Conclusion: This work successfully demonstrates a method to efficiently and accurately measure MLC leaf position, or backup jaw position, relative to the mechanical isocenter of the collimator.

60 APPLIED LIFE SCIENCES↗

SU-E-P-54: Evaluation of the Accuracy and Precision of IGPS-O X-Ray Image-Guided Positioning System by Comparison with On-Board Imager Cone-Beam Computed Tomography

Purpose: The purpose of this study is to assess the positioning accuracy and precision of IGPS-O system which is a novel radiographic kilo-voltage x-ray image-guided positioning system developed for clinical IGRT applications. Methods: IGPS-O x-ray image-guided positioning system consists of two oblique sets of radiographic kilo-voltage x-ray projecting and imaging devices which were equiped on the ground and ceiling of treatment room. This system can determine the positioning error in the form of three translations and three rotations according to the registration of two X-ray images acquired online and the planning CT image. An anthropomorphic head phantom and an anthropomorphic thorax phantom were used for this study. The phantom was set up on the treatment table with correct position and various “planned” setup errors. Both IGPS-O x-ray image-guided positioning system and the commercial On-board Imager Cone-beam Computed Tomography (OBI CBCT) were used to obtain the setup errors of the phantom. Difference of the Result between the two image-guided positioning systems were computed and analyzed. Results: The setup errors measured by IGPS-O x-ray image-guided positioning system and the OBI CBCT system showed a general agreement, the means and standard errors of the discrepancies between the two systems in the left-right, anterior-posterior, superior-inferior directions were −0.13±0.09mm, 0.03±0.25mm, 0.04±0.31mm, respectively. The maximum difference was only 0.51mm in all the directions and the angular discrepancy was 0.3±0.5° between the two systems. Conclusion: The spatial and angular discrepancies between IGPS-O system and OBI CBCT for setup error correction was minimal. There is a general agreement between the two positioning system. IGPS-O x-ray image-guided positioning system can achieve as good accuracy as CBCT and can be used in the clinical IGRT applications.

60 APPLIED LIFE SCIENCES↗

A clinically observed discrepancy between image-based and log-based MLC positions

Purpose: To present a clinical case in which real-time intratreatment imaging identified an multileaf collimator (MLC) leaf to be consistently deviating from its programmed and logged position by >1 mm. Methods: An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used to capture cine during treatment images. The author serendipitously visually identified a suspected MLC leaf displacement that was not otherwise detected. The leaf position as recorded on the EPID images was measured and log-files were analyzed for the treatment in question, the prior day’s treatment, and for daily MLC test patterns acquired on those treatment days. Additional standard test patterns were used to quantify the leaf position. Results: Whereas the log-file reported no difference between planned and recorded positions, image-based measurements showed the leaf to be 1.3 ± 0.1 mm medial from the planned position. This offset was confirmed with the test pattern irradiations. Conclusions: It has been clinically observed that log-file derived leaf positions can differ from their actual position by >1 mm, and therefore cannot be considered to be the actual leaf positions. This cautions the use of log-based methods for MLC or patient quality assurance without independent confirmation of log integrity. Frequent verification of MLC positions through independent means is a necessary precondition to trust log-file records. Intratreatment EPID imaging provides a method to capture departures from MLC planned positions.

60 APPLIED LIFE SCIENCES↗

Experiences at the Paul Scherrer Institute With a Remote Patient Positioning Procedure for High-Throughput Proton Radiation Therapy

Purpose: To describe a remote positioning system for accurate and efficient proton radiotherapy treatments. Methods and Materials: To minimize positioning time in the treatment room (and thereby maximize beam utility), we have adopted a method for remote patient positioning, with patients positioned and imaged outside the treatment room. Using a CT scanner, positioning is performed using orthogonal topograms with the measured differences to the reference images being used to define daily corrections to the patient table in the treatment room. Possible patient movements during transport and irradiation were analyzed through periodic acquisition of posttreatment topograms. Systematic and random errors were calculated for this daily positioning protocol and for two off-line protocols. The potential time advantage of remote positioning was assessed by computer simulation. Results: Applying the daily correction protocol, systematic errors calculated over all patients (n = 94) were below 0.6 mm, whereas random errors were below 1.5 mm and 2.5 mm, respectively, for bite-block and for mask immobilization. Differences between pre- and posttreatment images were below 2.8 mm (SD) in abdominal/pelvic region, and below 2.4 mm (SD) in the head. Retrospective data analysis for a subset of patients revealed that off-line protocols would be significantly less accurate. Computer simulations showed that remote positioning can increase patient throughput up to 30%. Conclusions: The use of a daily imaging and correction protocol based on a 'remote' CT could reduce positioning errors to below 2.5 mm and increase beam utility in the treatment room. Patient motion between imaging and treatment were not significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-loop positivity of the planar $ \mathcal{N} $ = 4 SYM six-point amplitude

We study the six-point NMHV ratio function in planar $ \mathcal{N} $ = 4 SYM theory in the context of positive geometry. The Amplituhedron construction of the integrand for the amplitudes provides a kinematical region in which the integrand was observed to be positive. It is natural to conjecture that this property survives integration, i.e. that the final result for the ratio function is also positive in this region. Establishing such a result would imply that preserving positivity is a surprising property of the Minkowski contour of integration and it might indicate some deeper underlying structure. We find that the ratio function is positive everywhere we have tested it, including analytic results for special kinematical regions at one and two loops, as well as robust numerical evidence through five loops. There is also evidence for not just positivity, but monotonicity in a “radial” direction. We also investigate positivity of the MHV six-gluon amplitude. While the remainder function ceases to be positive at four loops, the BDS-like normalized MHV amplitude appears to be positive through five loops.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Positive geometries and canonical forms

Recent years have seen a surprising connection between the physics of scattering amplitudes and a class of mathematical objects — the positive Grassmannian, positive loop Grassmannians, tree and loop Amplituhedra — which have been loosely referred to as “positive geometries”. The connection between the geometry and physics is provided by a unique differential form canonically determined by the property of having logarithmic singularities (only) on all the boundaries of the space, with residues on each boundary given by the canonical form on that boundary. The structures seen in the physical setting of the Amplituhedron are both rigid and rich enough to motivate an investigation of the notions of “positive geometries” and their associated “canonical forms” as objects of study in their own right, in a more general mathematical setting. In this paper we take the first steps in this direction. We begin by giving a precise definition of positive geometries and canonical forms, and introduce two general methods for finding forms for more complicated positive geometries from simpler ones — via “triangulation” on the one hand, and “push-forward” maps between geometries on the other. We present numerous examples of positive geometries in projective spaces, Grassmannians, and toric, cluster and flag varieties, both for the simplest “simplex-like” geometries and the richer “polytope-like” ones. We also illustrate a number of strategies for computing canonical forms for large classes of positive geometries, ranging from a direct determination exploiting knowledge of zeros and poles, to the use of the general triangulation and push-forward methods, to the representation of the form as volume integrals over dual geometries and contour integrals over auxiliary spaces. These methods yield interesting representations for the canonical forms of wide classes of positive geometries, ranging from the simplest Amplituhedra to new expressions for the volume of arbitrary convex polytopes.

97 MATHEMATICS AND COMPUTING↗

Long non-coding RNA MIAT is estrogen-responsive and promotes estrogen-induced proliferation in ER-positive breast cancer cells

Highlights: • lncRNA MIAT was over-expressed in ER-positive breast cancer tissues and cells. • Breast cancer cell MIAT expression was estrogen-dependent. • lncRNA MIAT promoted breast cancer cell growth. • lncRNA MIAT was required for breast cancer cell cycle progression. Estrogen drives the development and progression of estrogen receptor (ER)-positive breast cancer. However, the detailed mechanism underlying ER-driven carcinogenesis remains unclear despite extensive studies. Previously reports indicated higher expression of long non-coding RNA (lncRNA) myocardial infarction associated transcript (MIAT) in ER-positive breast cancer tissues than in ER-negative tissues. However, the functional relevance of MIAT in ER-positive breast cancer tumorigenesis was poorly understood. Here, we investigated the role of lncRNA MIAT in ER-positive breast cancer cells. MIAT was over-expressed in ER-positive breast cancer tissues and ER-positive breast cancer cell line MCF-7. Activating estrogen signaling by diethylstilbestrol (DES) led to a dose- and time-dependent up-regulation of MIAT in MCF-7 cells that was dependent on ERα, as evidenced by ERα silencing and pharmacological inhibition using ER antagonist ICI 182780. Silencing MIAT decreased DES-induced MCF-7 cell proliferation while overexpressing MIAT increased MCF-7 cell proliferation. Further mechanistic study identified that MIAT was critical for G1 to S phase cell cycle transition. Taken together, these results suggest that lncRNA MIAT is an estrogen-inducible lncRNA and a key regulator in ER-positive breast cancer cell growth. MIAT could serve as a potential biomarker and promising therapeutic target for ER-positive breast cancer.

60 APPLIED LIFE SCIENCES↗

Prone Positioning Causes the Heart To Be Displaced Anteriorly Within the Thorax: Implications for Breast Cancer Treatment

Introduction: Prone positioning has been suggested as an alternative to the conventional supine position for patients receiving breast radiotherapy, but few data exist on how this may alter heart location. We herein quantitatively compare the intrathoracic location of the heart in the prone and supine positions in patients treated for breast cancer. Methods and Materials: In 16 patients treated with tangent photons for breast cancer, the computed tomography planning images (obtained in the supine position) and diagnostic magnetic resonance images (obtained in the prone position) were studied. For each case, the distance between the anterior pericardium and the anterior chest wall was measured at nine specific points; three points at each of three axial levels. The differences in the measurements between the prone and supine positions were compared with the Wilcoxon signed-rank test. Results: There is a systematic displacement of the lateral and superior aspect of the heart closer to the chest wall in the prone vs. supine position (mean displacement 19 mm (95% confidence interval 13.7-25.1 mm, p < 0.001); the medial and inferior aspects remain fixed. There was also a reduction in volume of lung interposed between the heart and chest wall when prone (mean decrease of 22 mL, p < 0.001 for difference). Conclusions: The superior and lateral aspects of the heart typically move anteriorly during prone positioning compared with the supine position. This may have negative consequences in situations in which the high-risk target tissues include the chest wall or deep breast.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subsets of Women With Close or Positive Margins After Breast-Conserving Surgery With High Local Recurrence Risk Despite Breast Plus Boost Radiotherapy

Purpose: (1) To examine the effect of surgical margin status on local recurrence (LR) and survival following breast-conserving therapy; (2) To identify subsets with close or positive margins with high LR risk despite whole breast radiotherapy (RT) plus boost. Methods and Materials: Subjects were 2,264 women with pT1-3, any N, M0 invasive breast cancer, treated with breast-conserving surgery and whole breast {+-} boost RT. Five-year Kaplan-Meier (KM) LR, breast cancer-specific and overall survival (BCSS and OS) were compared between cohorts with negative (n = 1,980), close (n = 222), and positive (n = 62) margins. LR rates were analyzed according to clinicopathologic characteristics. Multivariable Cox regression modeling and matched analysis of close/positive margin cases and negative margin controls were performed. Results: Median follow-up was 5.2 years. Boost RT was used in 92% of patients with close or positive margins. Five-year KM LR rates in the negative, close and positive margin cohorts were 1.3%, 4.0%, and 5.2%, respectively (p = 0.001). BCSS and OS were similar in the three margin subgroups. In the close/positive margin cohort, LR rates were 10.2% with age <45 years, 11.8% with Grade III, 11.3% with lymphovascular invasion (LVI), and 26.3% with {>=}4 positive nodes. Corresponding rates in the negative margin cohort were 2.3%, 2.4%, 1.0%, and 2.4%, respectively. On Cox regression analysis of the entire cohort, close or positive margin, Grade III histology, {>=}4 positive nodes, and lack of systemic therapy were significantly associated with higher LR risk. When close/positive margin cases were matched to negative margin controls, the difference in 5-year LR remained significant (4.25% vs. 0.7%, p < 0.001). Conclusions: On univariable analysis, subsets with close or positive margins, in combination with age <45 years, Grade III, LVI, and {>=}4 positive nodes, have 5-year LR >10% despite whole breast plus boost RT. These patients should be considered for more definitive surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mitigating Errors in External Respiratory Surrogate-Based Models of Tumor Position

Purpose: To investigate the effect of tumor site, measurement precision, tumor-surrogate correlation, training data selection, model design, and interpatient and interfraction variations on the accuracy of external marker-based models of tumor position. Methods and Materials: Cyberknife Synchrony system log files comprising synchronously acquired positions of external markers and the tumor from 167 treatment fractions were analyzed. The accuracy of Synchrony, ordinary-least-squares regression, and partial-least-squares regression models for predicting the tumor position from the external markers was evaluated. The quantity and timing of the data used to build the predictive model were varied. The effects of tumor-surrogate correlation and the precision in both the tumor and the external surrogate position measurements were explored by adding noise to the data. Results: The tumor position prediction errors increased during the duration of a fraction. Increasing the training data quantities did not always lead to more accurate models. Adding uncorrelated noise to the external marker-based inputs degraded the tumor-surrogate correlation models by 16% for partial-least-squares and 57% for ordinary-least-squares. External marker and tumor position measurement errors led to tumor position prediction changes 0.3-3.6 times the magnitude of the measurement errors, varying widely with model algorithm. The tumor position prediction errors were significantly associated with the patient index but not with the fraction index or tumor site. Partial-least-squares was as accurate as Synchrony and more accurate than ordinary-least-squares. Conclusions: The accuracy of surrogate-based inferential models of tumor position was affected by all the investigated factors, except for the tumor site and fraction index.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole-breast irradiation: a subgroup analysis of criteria to stratify for prone position treatment

To select among breast cancer patients and according to breast volume size those who may benefit from 3D conformal radiotherapy after conservative surgery applied with prone-position technique. Thirty-eight patients with early-stage breast cancer were grouped according to the target volume (TV) measured in the supine position: small ({<=}400 mL), medium (400-700 mL), and large ({>=}700 ml). An ad-hoc designed and built device was used for prone set-up to displace the contralateral breast away from the tangential field borders. All patients underwent treatment planning computed tomography in both the supine and prone positions. Dosimetric data to explore dose distribution and volume of normal tissue irradiated were calculated for each patient in both positions. Homogeneity index, hot spot areas, the maximum dose, and the lung constraints were significantly reduced in the prone position (p < 0.05). The maximum heart distance and the V{sub 5Gy} did not vary consistently in the 2 positions (p = 0.06 and p = 0.7, respectively). The number of necessary monitor units was significantly higher in the supine position (312 vs. 232, p < 0.0001). The subgroups analysis pointed out the advantage in lung sparing in all TV groups (small, medium and large) for all the evaluated dosimetric constraints (central lung distance, maximum lung distance, and V{sub 5Gy}, p < 0.0001). In the small TV group, a dose reduction in nontarget areas of 22% in the prone position was detected (p = 0.056); in the medium and high TV groups, the difference was of about -10% (p = NS). The decrease in hot spot areas in nontarget tissues was 73%, 47%, and 80% for small, medium, and large TVs in the prone position, respectively. Although prone breast radiotherapy is normally proposed in patients with breasts of large dimensions, this study gives evidence of dosimetric benefit in all patient subgroups irrespective of breast volume size.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tbx18-positive cells-derived myofibroblasts contribute to renal interstitial fibrosis via transforming growth factor-β signaling

It has been demonstrated that the T-box family transcription factor 18 (Tbx18) -positive cells give rise to renal mesenchymal cells and contribute to the development of the urinary system. However, it is unclear whether Tbx18-positive cells are the origin of the myofibroblasts during renal fibrosis. The present study aimed to determine the contribution of Tbx18-positive cells in kidney fibrosis and their underlying mechanism. We show that Tbx18-positive cells contribute to the development of the urinary system, especially renal fibroblasts. Following unilateral ureteral obstruction (UUO), genetic fate tracing results demonstrated that Tbx18-positive cells not only proliferate but also expand and differentiate into fibroblasts and myofibroblasts, indicating that they may act as profibrotic progenitors. Cell culture results suggest that transforming growth factor (TGF)-β promotes Tbx18-positive cells differentiation into myofibroblasts and assist their contribution to kidney fibrosis. Overall, the present study demonstrated that Tbx18-positive cells may act as profibrotic progenitor cells in a pathological condition of UUO-induced injury. Moreover, TGF-β may play a role in differentiation of Tbx18-positive cells into myofibroblasts in kidney fibrosis. These findings may provide a potential target on Tbx18-positive myofibroblast progenitors in the treatment of renal fibrosis.

60 APPLIED LIFE SCIENCES↗