Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plasma diodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Electrical and thermal characteristics of LaB6 thermionic hollow cathodes operating in He, D2, Ar, and Xe at 4–200 Pa and 0.25–5 A cm−2

We report characteristics of lanthanum hexaboride (LaB6) cathodes for conditions relevant to a high-voltage, high-current switching device. LaB6 is selected because of its relatively low work function, stability in the presence of many common gas impurities, and a low evaporation rate (long life) at operating temperatures. We have investigated the effect of cathode geometry, gas type, pressure, and current on a LaB6 hollow cathode in a diode configuration with an opposing planar anode. The gas is stagnant at a relatively low pressure of 4–200 Pa (0.03–1.5 Torr) because of device high-voltage standoff requirements. In all cases, the plasma voltage decreases to a plateau value with increasing current where a practical device would operate. The plateau voltage aligns with the fill gas excitation or ionization voltage, depending on conditions. At high current, the cathode temperature exceeds that required for thermionic emission to supply the total current, a behavior that is understood by accounting for back-diffusing bulk electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Self-Magnetic Pinch (SMP) Radiographic Diode Performance on RITS-6 at Sandia National Laboratories

The goals of an electron beam-driven radiographic source are the focusing of high current at high voltage to a minimal spot size with excellent shot-to-shot reproducibility. The Self-Magnetic Pinch (SMP) diode makes use of such an intense electron beam impinging on a high-atomic weight (tantalum) converter, a counter-streaming ion beam to help minimize the spot size, and operation in a magnetic field-free diode region which further encourages small spot size. Through a series of diode development experiments, output voltages up to 12.5 MV and output currents up to 225 kA have been characterized, with resulting spot sizes below ~ few mm. Scaling studies with parameter variation, such as diode aspect ratio and anode-cathode (A-K) gap variation, give systematic validation to what has heretofore been noted anecdotally by other research groups. While the lack of an imbedded magnetic field helps minimize the SMP spot size, a secondary result may be the generation of beam instabilities which can terminate the radiation pulse. There is anecdotal evidence that in-situ DC heating of the diode region can help stabilize the beam pinch. Clear experimental evidence exists that DC heating/RF cleaning results in better control over the counter-streaming ion population. Expanded use of spatial dose-rate detection is shown to yield new insights into electron beam dynamics in the SMP diode. An attendant study of the SMP diode as a load for an Inductive Voltage Adder (IVA) driver leads to insights into the behavior of the IVA-SMP diode configuration, viewed as a total system, and yields constraints on the overall impedance behavior of the SMP diode load.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Self-Magnetic Pinch (SMP) radiographic diode performance on RITS-6 at Sandia National Laboratories: 1) Diode Dynamics, DC Heating to extend Radiation Pulse

Radiographic diodes focus an intense electron beam to a small spot size to minimize the source area of energetic photons for radiographic interrogation. The self-magnetic pinch (SMP) diode has been developed as such a source and operated as a load for the RITS-6 Inductive Voltage Adder (IVA) driver. While experiments support the generally accepted conclusion that a 1:1 aspect diode (cathode diameter equals anode-cathode gap) delivers optimum SMP performance, such experiments also show that reducing the cathode diameter, while reducing spot size, also results in reduced radiation dose, by as much as 50%, and degraded shot reproducibility. Analyzation of the effective electron impingement angle on the anode converter with time made possible by a newly developed dose-rate array diagnostic indicates that fast-developing oscillations of the angle are correlated with early termination of the radiation pulse on many of the smaller-diameter SMP shots. This behavior as a function of relative cathode size persists through experiments with output voltages and currents up to 11.5 MV and 225 kA, respectively, and with spot sizes below ~ few mm. Since simulations to date have not predicted such oscillatory behavior, considerable discussion of the angle-behavior of SMP shots is made to lend credence to the inference. There is clear anecdotal evidence that DC heating of the SMP diode region leads to stabilization of this oscillatory behavior. This is the first of two papers on the performance of the SMP diode on the RITS-6 accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Origin of the injection-dependent emission blueshift and linewidth broadening of III-nitride light-emitting diodes

III-nitride light-emitting diodes (LEDs) exhibit an injection-dependent emission blueshift and linewidth broadening that is severely detrimental to their color purity. By using first-principles multi-scale modeling that accurately captures the competition between polarization-charge screening, phase-space filling, and many-body plasma renormalization, we explain the current-dependent spectral characteristics of polar III-nitride LEDs fabricated with state-of-the-art quantum wells. Our analysis uncovers a fundamental connection between carrier dynamics and the injection-dependent spectral characteristics of light-emitting materials. For example, polar III-nitride LEDs offer poor control over their injection-dependent color purity due to their poor hole transport and slow carrier-recombination dynamics, which forces them to operate at or near degenerate carrier densities. Designs that accelerate carrier recombination and transport and reduce the carrier density required to operate LEDs at a given current density lessen their injection-dependent wavelength shift and linewidth broadening.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Equivalent equilibrium ion distributions in ion sources and beams

Ion sources and ion beams often contain ions of more than one charge-to-mass ratio, due to the presence of multiple ionization states and/or multiple atomic and molecular ion species in the source. We show that, under certain conditions, analysis of these systems can be simplified using the notion of “equivalent equilibrium ion distributions” (EEIDs). These distributions have identical ion trajectories, space-charge distributions, and electric-field distributions, but can be composed of ion species with arbitrary charge-to-mass ratios. We use this result to obtain multi-species generalizations for the perveance of an ion diode, which relates the diode voltage to the extracted beam current, and for the perveance of a drifting ion beam, which determines the axial length-scale for beam expansion due to the self-electric field. Applied to a quasi-neutral plasma ion source containing cold ions and hot electrons, we find that the location of the beam-plasma interface (meniscus), where ions are extracted from the plasma, depends on the electron density and ion energy per unit charge at the interface, independent of the ion composition. For certain types of numerical simulations, EEIDs allow one to calculate the beam optics of an intense multi-species ion source by doing a simulation for a single ion species with an artificial charge-to-mass ratio chosen to minimize computation time. We illustrate these results using the 3D particle-in-cell, finite-element code Aleph. The simulations show how ions in a plasma source self-consistently accelerate to the supersonic speed needed for steady, radially expanding flow. Multi-species equilibria are subject to streaming instabilities because, while the different species have the same kinetic energy per unit charge, their velocities scale with the square root of the charge-to-mass ratio. The simulations show that a strong ion streaming instability can occur in a multi-species plasma ion source.

74 ATOMIC AND MOLECULAR PHYSICS↗

Solar energy converter using surface plasma waves

Sunlight is dispersed over a diffraction grating formed on the surface of a conducting film on a substrate. The angular dispersion controls the effective grating period so that a matching spectrum of surface plasmons is excited for parallel processing on the conducting film. The resulting surface plasmons carry energy to an array of inelastic tunnel diodes. This solar energy converter does not require different materials for each frequency band, and sunlight is directly converted to electricity in an efficient manner by extracting more energy from the more energetic photons.

Anderson, L. M.↗

Argon metastable density and temperature of a 94 GHz microplasma

Laser diode absorption spectroscopy is used to experimentally measure Ar(1s 5 ) metastable density and translational gas temperature within a 94 GHz microplasma. A square two-dimensional photonic crystal (PhC) at this resonance frequency serves to ignite and sustain the plasma from 20 to 200 Torr (2.7 × 10 3 –2.7 × 10 4 Pa) by using millimeter wave power from 300 to 1000 mW. Metastable density within the plasma is estimated from the absorption line shape of the laser traversing the PhC. The metastable density reaches an order of 10 19 m –3 at lower pressure and decreases as pressure increases. From the Lorentzian line shape of the absorption profile at 811.53 nm, the gas temperature is extracted and found to increase from 500 K at 20 Torr to 1300 K at 200 Torr. Furthermore, these data are analyzed and compared with a zero-dimensional plasma model and with previous experimental plasma results at 43 GHz.

42 ENGINEERING↗

Inferring fusion nuclear burnwidths with low gain photomultiplier impulse response functions

When an inertial confinement fusion implosion is compressed, it maintains thermonuclear density and temperatures for a very short time scale, about 100 ps. The Gamma Reaction History diagnostic measures the time evolution of the fusion burn, but its temporal resolution is limited by the use of a photomultiplier tube (PMT) to amplify the photon signal. Multichannel plate-based PMTs have a fast (~120 ps) full-width at half-max impulse response function (IRF), but the time scale is similar to the incoming physics signal. An analysis routine is used to remove the effect of the PMT IRF and infer the incident fusion burnwidth. With the National Ignition Facility achieving ignition and creating much brighter signals, the PMTs are run at gains three orders of magnitude lower than nominal operation. Calibration at these settings shows the PMT IRFs get ~15% wider. Taking the gain-dependent IRF can affect the inferred nuclear burnwidths by up to ~15%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multichannel Fiber-Optic Silicon Fabry–Pérot Interferometric Bolometer System for Plasma Radiation Measurements

A single-channel fiber-optic bolometer system based on a high-finesse silicon Fabry–Pérot interferometer (FPI) was previously reported, intended to measure plasma radiation from the magnetically confined fusion chamber. Recently, we developed a multichannel fiber-optic bolometer system with five bolometers multiplexed using a coarse wavelength division multiplexer (CWDM) and interrogated with a white-light system involving a superluminescent light-emission diode source and a high-speed spectrometer. One of the bolometers was used as the reference bolometer to compensate for the ambient temperature variations, and the other four bolometers were used for radiation measurement. The bolometers have a simple structure with a silicon pillar at the end of the single-mode fiber and a gold disk on the other side of the silicon pillar. They are also easy to fabricate without stringent requirements on the optical alignment. Analysis of the system optimization was performed to improve the noise performance and to mitigate the vibration effect that may present in the practical application. The system had a significantly enhanced measurement range compared to the previous high-finesse FPI bolometer system for measuring radiation. Test results performed in air using a 405 nm laser as the radiation source showed that the temperature resolution and the noise-equivalent power density of the sensing bolometers connected to each channel of the CWDM were, respectively, ~0.4 mK and ~0.1 W/m2, with a time constant of ~220 ms, which is comparable to the previous more complicated fiber-optic bolometer systems based on high-finesse FPIs that were interrogated using wavelength-scanning lasers.

Uddin, Nezam↗

Ultrafast Modulation and Switching of Quantum-Well Lasers using Terahertz Fields

Modulation and switching of semiconductor lasers are important for laser-based information technology. Typically the speed of modulation and switching is limited by interband processes such as stimulated and spontaneous recombinations which occur on a nanosecond time scale. This is why the diode laser modulation has been restricted to tens of GHz. Modulation at higher speed is highly desirable as the information technology enters into the so-called tera-era. In this paper, we study the possibility of utilizing THz-field-induced plasma heating to modulate quantum-well lasers. This is a timely study since, with the advancement of THz solid-state sources and free-electron lasers, THz physics and related technology is currently coming out of its infancy. The investigation of interplaying THz and optical fields is also of intruiging fundamental interest. First, we introduce theoretical plasma heating results for the quantum-well optical amplifier in the presense of an intense half-cycle THz pulse. The heated carrier distributions are then utilized to calculate the THz-pulse-induced change in refractive index and gain profile. Since the electron-hole-plasma is heated using intraband transitions, we circumvent the usual complications due to an overall change in density, and the nonlinear recovery is governed solely by the carrier-LO-phonon interactions, typically 5 ps for a complete recovery. This procedure implies THz and sub-THz switching and recovery rates, respectively; using either gain modulation or index modulation. Plasma heating via steady-state THz fields is also studied. Finally, numerical simulation of a coupled set of equations to investigate the THz modulation based on a simplified model for quantum-well lasers is presented. Our results show that a semiconductor laser can be modulated at up to 1 THz with little distortion with a THz field amplitude at the order of a few kV/cm. Laser responses to a change in THz frequency will be shown. Constraints, practicalities, and applications will be discussed.

Ning, Cun-Zheng↗

System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma

Monolithic, millimeter wave “system-on-chip” technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75–110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. Finally, a significant aspect of imaging measurement is focusing on artificial intelligence for science applications.

47 OTHER INSTRUMENTATION↗

A computer model of solar panel-plasma interactions

High power solar arrays for satellite power systems are presently being planned with dimensions of kilometers, and with tens of kilovolts distributed over their surface. Such systems face many plasma interaction problems, such as power leakage to the plasma, particle focusing, and anomalous arcing. These effects cannot be adequately modeled without detailed knowledge of the plasma sheath structure and space charge effects. Laboratory studies of 1 by 10 meter solar array in a simulated low Earth orbit plasma are discussed. The plasma screening process is discussed, program theory is outlined, and a series of calibration models is presented. These models are designed to demonstrate that PANEL is capable of accurate self consistant space charge calculations. Such models include PANEL predictions for the Child-Langmuir diode problem.

Cooke, D. L.↗

Fiber-Optic Silicon Fabry-Perot Interferometric Bolometer: The Influence of Mechanical Vibration and Magnetic Field

Plasma radiation plays an important role in the operation and control of magnetic confinement fusion and is typically measured by bolometers. Here, we study the influence of mechanical vibration and magnetic field, which are typically present in magnetic confinement fusion devices, on the performance of a fiber-optic bolometer (FOB) based on silicon Fabry-Perot interferometer (FPI) demodulated by a scanning diode laser. It is found that both the vibration and magnetic field could cause large noise due to the birefringence of the silicon FPI. To mitigate the birefringence effects, we demonstrated two effective methods: polarization maintaining FOB and polarization scrambling. We show that two methods can be effective in mitigating the effect caused by the sensor birefringence: (1) replacing the regular single-mode fiber in the FOB system with polarization-maintaining fiber and (2) using a polarization scrambler after the laser source. For both methods, no significant increase in the noise was observed in the vibration and magnetic field tests. Finally, our research highlights the importance of the polarization management for the FOB systems toward their practical applications in magnetic-confinement fusion systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ELM Suppression by Boron Powder Injection and Comparison with Lithium Powder Injection on EAST

Type I edge-localized modes (ELMs) in the Experimental Advanced Superconducting Tokamak (EAST) were completely suppressed via boron powder injection into the X-point region of an upper-single null configuration over a wide range of operating conditions (2.8 < P aux < 7.5 MW, 3.8 × 10 19 < n e < 6 × 10 19 m -3 , RF-only and RF + NBI heating scenarios, both grad-B drift directions, and even He ion majority plasmas) (Sun et al. in Nucl. Fusion, 2020). A window of edge B concentration for stable long pulse operation was identified: too low and ELMs return, too high and the discharge suffers radiative collapse. The injection of boron powder above the minimum for ELM suppression coincided with the occurrence of an edge harmonic oscillation detected in magnetics (both on the high-field side and low-field side), in AXUV diodes near the upper X-point, divertor Dα emission, and in a range of other diagnostics (Diallo et al. in: Proceedings of 2020 IAEA fusion energy conference, 2021). Furthermore, no harmonic oscillation was observed when ELMs were present, and stored energy was slightly increased at constant density during ELM suppression. Core tungsten emission during ELM suppression either increased or decreased relative to ELMy H-mode, but the W emission was maintained at acceptable levels. The threshold B injection rate was measured for several conditions, and found to increase with heating power. Li powder injection into comparable discharges also resulted in a short phase of ELM suppression, but density and stored energy both decreased due to the strong pumping effect of lithium; no edge harmonic oscillation was observed with Li injection, indicating that the ELM suppression mechanisms differ. The new set of B-seeded, ELM-suppressed discharges exhibited certain characteristics of quiescent H-mode (Burrell et al. in Phys Plasmas 8:2153, 2001), but did not require high shear, counter beams, etc. The wide operating window and compatibility with RF-only discharges paves the way for future experiments targeting long pulse H-mode discharges with complete ELM suppression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System-on-Chip approach microwave diagnostics development for burning plasma

System-on-chip (SoC) millimeter wave integrated circuit technology has been developed and employed in chip heterodyne radiometers in Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometer (MIR) on the DIII-D tokamak for 2D electron temperature and density fluctuation diagnostics. The W-band (75-110 GHz) ECEI system has been employed with 20 poloidal horn receiver modules with customized monolithic integrated circuit chips and internal local oscillator coupling path. The new SoC approach demonstrates > 30 dB additional gain on the receiver and 95% electronics noise suppression compared to the previous Schottky diode mixer array . An F-band (110-140 GHz) receiver chip has been developed to measure MHD and turbulence behavior on the DIII-D high-field side, such as Alfven eigenmodes. Furthermore, it can image pedestal structure evolution on fusion facilities with stronger magnetic fields, such as ASDEX-U, EAST, HL-2M, and LHD. The F-band chip performance has been tested in the laboratory. Also, V-band (55-75 GHz) transmitter and receiver modules (55-75 GHz) have been developed for DIII-D and NSTX-U Furthermore, microwave Imaging Reflectometer (MIR) application suitability for 2D density fluctuation imaging on the pedestal region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optically pumped deep-UV multimode lasing in AlGaN double heterostructure grown by molecular beam homoepitaxy

Multimode lasing at sub-300 nm wavelengths is demonstrated by optical pumping in AlGaN heterostructures grown on single-crystal AlN substrates by plasma-assisted molecular beam epitaxy. Edge-emitting ridge-based Fabry–Pérot cavities are fabricated with the epitaxial AlN/AlGaN double heterostructure by a combined inductively coupled plasma reactive ion etch and tetramethylammonium hydroxide etch. The emitters exhibit peak gain at 284 nm and modal linewidths on the order of 0.1 nm at room temperature. The applied growth technique and its chemical and heterostructural design characteristics offer certain unique capabilities toward further development of electrically injected AlGaN laser diodes.

36 MATERIALS SCIENCE↗

Life test of a xenon hollow cathode for a space plasma contractor

A plasma contacting device using a hollow cathode for plasma production has been baselined for use on the Space Station. This application will require reliable, continuous operation of the cathode at electron emission currents of between 0.75 and 10 A for two years (17,500 hours). In order to validate life-time capability, a hollow cathode, operated in a diode configuration, has been tested for more than 8600 hours of stable discharge operation as of March 30, 1994. This cathode is operated at a steady-state emission current of 12.0 and a fixed xenon flow rate of 4.5 sccm. Discharge voltage and cathode temperature have remained relatively stable at approximately 12.9 V and 1260 C during the test. The test has experienced 7 shutdowns to date. In all instances, the cathode was reignited at about 42 V and resumed stable operation. This test represents the longest demonstration of stable operation of high current (greater than 1A) xenon hollow cathodes reported to date.

Sarver-Verhey, Timothy R.↗