Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pinhole optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Emittance and lifetime measurement with damping wigglers

National Synchrotron Light Source II (NSLS-II) is a new third-generation storage ring light source at Brookhaven National Laboratory. The storage ring design calls for small horizontal emittance (<1 nm-rad) and diffraction-limited vertical emittance at 12 keV (8 pm-rad). Achieving low value of the beam size will enable novel user experiments with nm-range spatial and meV-energy resolution. The high-brightness NSLS-II lattice has been realized by implementing 30-cell double bend achromatic cells producing the horizontal emittance of 2 nm rad and then halving it further by using several Damping Wigglers (DWs). This paper is focused on characterization of the DW effects in the storage ring performance, namely, on reduction of the beam emittance, and corresponding changes in the energy spread and beam lifetime. The relevant beam parameters have been measured by the X-ray pinhole camera, beam position monitors, beam filling pattern monitor, and current transformers. In this paper, we compare the measured results of the beam performance with analytic estimates for the complement of the 3 DWs installed at the NSLS-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technology and Opportunities of Photon Sieve CubeSat with Deployable Optical Membrane

A photon sieve (PS) is a revolutionary optical instrument that provides high resolution imaging at a fraction of the weight of typical telescopes, with an areal density of 0.3 kg/m2 compared to 25 kg/m2 for the James Webb Space Telescope. The photon sieve is a variation of a Fresnel Zone Plate consisting of many small holes arranged in a series of concentric rings. The sieve works by diffracting light of a certain wavelength to a specified focal point for imaging, so that only a specific wavelength can be imaged. Moreover, the better image contrast and higher signal-to-noise ratios come from suppressing higher diffracted orders by apodizing the number of pinholes in the outer rings. Finally, a photon sieve requires less supports and can withstand more deformation without a reduction in the imaging qualities. Due to these properties, various groups have created PS CubeSats for Earth and Sun imaging at a low cost and weight specifically using deployable technology. A team at the Air Force Research Laboratory created a design and prototype of a mechanism that deploys a 20 cm diameter photon sieve. The United States Air Force Laboratory used a similar design to create a CubeSat-based deployable photon sieve. The team at NASA Langley Research Center has researched photon sieves for conducting an Earth-observing experiment using LIDAR (Light Detection and Ranging) with a higher signal-to-noise ratio benefit from the PS. This paper provides a state of the art overview on existing PS CubeSat technology with deployable structures and applications. Especially, the paper introduces PS for LIDAR applications and discusses the CubeSat-based PS challenge being worked at the NASA Langley Research Center.

Hyun Jung Kim↗

Microfocus/Polycapillary-Optic Crystallographic X-Ray System

A system that generates an intense, nearly collimated, nearly monochromatic, small-diameter x-ray beam has been developed for use in macromolecular crystallography. A conventional x-ray system for macromolecular crystallography includes a rotating-anode x-ray source, which is massive (.500 kg), large (approximately 2 by 2 by 1 m), and power-hungry (between 2 and 18 kW). In contrast, the present system generates a beam of the required brightness from a microfocus source, which is small and light enough to be mounted on a laboratory bench, and operates at a power level of only tens of watts. The figure schematically depicts the system as configured for observing x-ray diffraction from a macromolecular crystal. In addition to the microfocus x-ray source, the system includes a polycapillary optic . a monolithic block (typically a bundle of fused glass tubes) that contains thousands of straight or gently curved capillary channels, along which x-rays propagate with multiple reflections. This particular polycapillary optic is configured to act as a collimator; the x-ray beam that emerges from its output face consists of quasi-parallel subbeams with a small angular divergence and a diameter comparable to the size of a crystal to be studied. The gap between the microfocus x-ray source and the input face of the polycapillary optic is chosen consistently with the focal length of the polycapillary optic and the need to maximize the solid angle subtended by the optic in order to maximize the collimated x-ray flux. The spectrum from the source contains a significant component of Cu K (photon energy is 8.08 keV) radiation. The beam is monochromatized (for Cu K ) by a nickel filter 10 m thick. In a test, this system was operated at a power of 40 W (current of 897 A at an accelerating potential of 45 kV), with an anode x-ray spot size of 41+/-2 microns. Also tested, in order to provide a standard for comparison, was a commercial rotating-anode x-ray crystallographic system with a pyrolytic graphite monochromator and a 250-micron pinhole collimator, operating at a power of 3.15 kW (current of 70 mA at an accelerating potential of 45 kV). The flux of collimated Cu K radiation in this system was found to be approximately 16 times that in the rotatinganode system. Data on x-ray diffraction from crystals of tetragonal form of lysozyme (protein) in this system were found to be of high quality and to be reducible by use of standard crystallographic software.

Joy, Marshall↗

A Wolter imager on the Z machine to diagnose warm x-ray sources

A new Wolter x-ray imager has been developed for the Z machine to study the emission of warm (>15 keV) x-ray sources. A Wolter optic has been adapted from observational astronomy and medical imaging, which uses curved x-ray mirrors to form a 2D image of a source with 5 × 5 × 5 mm 3 field-of-view and measured 60-300-μm resolution on-axis. The mirrors consist of a multilayer that create a narrow bandpass around the Mo Kα lines at 17.5 keV. Here, we provide an overview of the instrument design and measured imaging performance. In addition, we present the first data from the instrument of a Mo wire array z-pinch on the Z machine, demonstrating improvements in spatial resolution and a 350-4100× increase in the signal over previous pinhole imaging techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

All-vacuum-deposited inorganic cesium lead halide perovskite light-emitting diodes

Polycrystalline CsPbBr 3 thin films are deposited by vacuum co-evaporation of cesium halide and lead halide precursors, leading to uniform pinhole-free morphology and precise control over the film thickness and precursor stoichiometry. By utilizing the organic hole and electron transport layers, all-vacuum-deposited perovskite LEDs are fabricated. The resulting devices exhibit a maximum luminance of 1800 cd/m 2 , a 531 nm emission wavelength peak with a spectral linewidth of 21 nm, and an external quantum efficiency of 1.1%.

36 MATERIALS SCIENCE↗

Design, Assembly, and Testing of the Neutron Imaging Lens for the National Ignition Facility

The National Ignition Facility will begin testing DT fuel capsules yielding greater than 10^13 neutrons during 2010. Neutron imaging is an important diagnostic for understanding capsule behavior. Neutrons are imaged at a scintillator after passing through a pinhole. The pixelated, 160-mm square scintillator is made up of ¼ mm diameter rods 50 mm long. Shielding and distance (28 m) are used to preserve the recording diagnostic hardware. Neutron imaging is light starved. We designed a large nine-element collecting lens to relay as much scintillator light as reasonable onto a 75 mm gated microchannel plate (MCP) intensifier. The image from the intensifier’s phosphor passes through a fiber taper onto a CCD camera for digital storage. Alignment of the pinhole and tilting of the scintillator is performed before the relay lens and MCP can be aligned. Careful tilting of the scintillator is done so that each neutron only passes through one rod (no crosstalk allowed). The 3.2 ns decay time scintillator emits light in the deep blue, requiring special glass materials. The glass within the lens housing weighs 26 lbs, with the largest element being 7.7 inches in diameter. The distance between the scintillator and the MCP is only 27 inches. The scintillator emits light with 0.56 NA and the lens collects light at 0.15 NA. Thus, the MCP collects only 7% of the available light. Baffling the stray light is a major concern in the design of the optics. Glass cost considerations, tolerancing, and alignment of this lens system will be discussed.

47 OTHER INSTRUMENTATION↗

X-ray imaging of extended objects using nonoverlapping redundant array

A common problem associated with X-ray imaging using coded apertures is the reconstruction of low-intensity extended objects. In the decoding of such objects, the overlapping images from the multiple pinholes give rise to noise cross talk and, in many cases, also to signal cross talk. In this paper, an alternate approach is proposed based on the principle used in an earlier (Yin et al., 1980) laboratory device for the real-time viewing of X-ray objects. It is shown that with this approach, the nonoverlapping redundant array, the sidelobes in the point spread function are not eliminated but merely displaced through a suitable choice of geometry. In this manner, the sidelobes no longer contribute to the background in the vicinity of a reconstructed image, and both signal and noise cross talks are completely eliminated. It may now be possible to reconstruct extended X-ray objects in 3-D by simple optical correlation and tomographically by a computer.

Yin, L.-I.↗

Fresnel diffractive imaging: Experimental study of coherence and curvature

A Fresnel coherent diffractive imaging experiment is performed using a pinhole as a test object. The experimental parameters of the beam curvature and coherence length of the illuminating radiation are varied to investigate their effects on the reconstruction process. It is found that a sufficient amount of curvature across the sample strongly ameliorates the effects of low coherence, even when the sample size exceeds the coherence length.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying the Influence of Defects on Selectivity of Electrodes Encapsulated by Nanoscopic Silicon Oxide Overlayers

Encapsulation of electrocatalysts and photocatalysts with semipermeable nanoscopic oxide overlayers that exhibit selective transport properties is an attractive approach to achieve high redox selectivity. However, defects within the overlayers-such as pinholes, cracks, or particle inclusions-may facilitate local high rates of parasitic reactions by creating pathways for facile transport of undesired reactants to exposed active sites. Scanning electrochemical microscopy (SECM) is an attractive method to determine the influence of defects on macroscopic performance metrics thanks to its ability to measure the relative rates of competing electrochemical reactions with high spatial resolution over the electrode. Here, we report the use of SECM to determine the influence of overlayer defects on the selectivity of silicon oxide (SiOx) encapsulated platinum thin-film electrocatalysts operated under conditions where two competing reactions-the hydrogen evolution and Fe(III) reduction reactions-can occur. After an SECM methodology is described to determine spatially resolved selectivity, representative selectivity maps are correlated with the location of defects that are characterized by optical, electron, and atomic force microscopies. This analysis reveals that certain types of defects in the oxide overlayer are responsible for ∼60-90% of the partial current density toward the undesired Fe(III) reduction reaction. By correcting for defect contributions to Fe(III) reduction rates, true Fe(III) permeability values for the SiOxoverlayers were determined to be over an order of magnitude lower than permeabilities determined from analyses that ignore the presence of defects. Lastly, different types of defects were studied revealing that defect morphology can have varying influence on both redox selectivity and calculated permeability. This work highlights the need for spatially resolved measurements to evaluate the performance of oxide-encapsulated catalysts and understand their performance limits.

25 ENERGY STORAGE↗

Lamb Wave Focusing Transducer for Efficient Coupling to Wavelength-Scale Structures in Thin Piezoelectric Films

This study describes the theoretical and experimental investigation of interdigitated transducers (IDTs) capable of producing focused acoustical beams in thin film piezo-electric materials. A mathematical formalism describing focused acoustical beams, Lamb beams, is presented and related to their optical counterparts in two- and three-dimensions. A novel Fourier domain transducer design methodology was developed and utilized to produce near diffraction limited focused beams with in a thin film AlN membrane. The properties of the acoustic beam formed by the transducer were studied by means of Doppler vibrometry implemented with a scanning confocal balanced homodyne interferometer. Fourier domain modal analysis confirmed that 85% of the acoustical power was delivered to the targeted focused beam which was constituted from the lowest order symmetric mode, while 2% was delivered unintentionally to the beam formed from the anti-symmetric mode, and the remaining power was isotropically scattered. The transmission properties of the acoustic beams as they interact with devices with wavelength scale features were also studied, demonstrating minimal insertion loss for devices in which a subwavelength, pinhole apertures was included.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solvent-Engineering Method to Deposit Compact Bismuth-Based Thin Films: Mechanism and Application to Photovoltaics

Bismuth-based materials have been studied as alternatives to lead-based perovskite materials for photovoltaic applications. However, poor film quality has limited device performance. Here, we developed a solvent-engineering method and show that it is applicable to several bismuth-based compounds. Through this method, we obtained compact films of methylammonium bismuth iodide (MBI), cesium bismuth iodide (CBI), and formamidinium bismuth iodide (FBI). On the basis of film growth theory and experimental analyses, we propose a possible mechanism of film formation. Additionally, we demonstrate that the resultant compact MBI film is more suitable to fabricate efficient and stable photovoltaic devices compared to baseline MBI films with pinholes. We further employed a new hole-transporting material to reduce the valence-band offset with the MBI. The best-performing photovoltaic device exhibits an open-circuit voltage of 0.85 V, fill factor of 73%, and a power conversion efficiency of 0.71%, the highest reported values for MBI-based photovoltaic devices.

14 SOLAR ENERGY↗

Advanced SOFC quality control and the role of manufacturing defects on stack reliability

Atrex Energy rolled out first commercial SOFC generator products in 2013. Following that we embarked on implementation of mass production in order to ramp up productivity and lower the costs in the meantime. To ensure the goal of mass production, an accurate, cost effective and consistent quality control methodology needs to be in place. The aim of this DOE funded project is to devise a machine and methodology for cell quality control using modern non-destructive testing methods and cell rejection criterion based on the empirical determination of the role of manufacturing flaws on stack degradation and reliability. The work scope encompasses two goals aimed at 1) developing automatable techniques for objective flaw detection and 2) developing an understanding of the ramifications of flaws on stack and cell reliability. By accomplishing these two goals it is likely that an advanced stage Quality Control (QC) device can be developed. This project scope encompasses: 1) Invention of a high speed automated instrument for spatial mapping of surface and sub-surface imperfections in production cells (ex situ) using modern imaging techniques. 2) Identification of rejection criteria upon which to screen cells from production by: a. Magnification of the effect of production defects on cell degradation through fabrication and testing of micro-cells which encompass these imperfections. b. The long term testing of full size production cells both as single cells and in small stacks, in order to correlate the (in situ) performance and degradation with the imperfection type (identified ex-situ) and hence be able to classify imperfections as actual defects. We first built a defect library with the cells containing imperfections classified and documented. The cells with various imperfections were tested to evaluate the imperfection potential impact on cell electrochemical performance. Evaluations were conducted on minicell, single cell and stack levels. On minicell level, pinhole, scratch, crack, contamination, and pop-out were investigated. We found: (1) none of the imperfections causes calamity type failure, (2) pinholes do not show measurable effect on minicell performance, (3) imperfection such as electrolyte abrasion, scratch, and pop out cause minicell potential to fluctuate by different degrees; the cells with such imperfections exhibit sensitivity of potential to high fuel utilization and “self healing” behavior. On single cell level we evaluated the effect of long crack and high population pinholes. The cell with a long crack does not show performance compromise at start. There is no potential fluctuation or sensitivity to high fuel utilization or catastrophic failure. The voltage degradation due to thermal cycle is slightly higher than normal cells. The cells with high population pinholes perform surprisingly as well as normal cells over a period of 3,500h. Even when subjected to cyclic load condition, the cells 4 show negligible degradation. Our cells appear to have “self immunization” feature which fends off the adversary effects of certain imperfections. Defects were also evaluated on stack level. Two stacks were made each with ten defect cells. The first stack was tested for 13,2000h under steady load condition while the second was tested for 9,000h under transient load conditions. We found: (1) voltage fluctuation and sensitivity to thermal cycle were not observed in contrast to minicell test, (2) of the various cracks examined, including longitudinal cracks, circumferential crack, crack near closed and open ends, none exhibited distinguishable impact on performance, (3) defect cells exhibited higher degradation rates on average under steady load condition; Individually some defect cells performed similarly or better than reference cells, (4) under steady load condition all the cells degrade monotonically with degradation rate increasing with time, (5) under cyclic (transient) load condition, both defect and reference cells exhibit complex dynamic behaviors, (6) fuel loss (leak) was measured occasionally for stack 1, the cells with crack showed the highest fuel loss increase, nevertheless, no correlation with performance degradation could be established with certainty, and (7) no catastrophic failure ever happened other than incremental degradation. Posttest inspection and microanalysis were carried out; the observations are summarized in what follows: (1) Electrolyte pinholes, some scratches and IC porosity became undetectable after testing. (2) The cathode covering the popout defects is intact without any cracking or delamination. (3) The scratch was covered by cathode in pristine state; Ni oxide or NiO-YSZ filled the space where electrolyte was missing. After >10,000h operation, the cathode that used to cover the scratch was missing but the size of the scratch remains unchanged; there is a fairly dense Ni oxide layer on top of the scratch. (4) All of the cracks remain their original dimensions. Current collector kept longitudinal cracks closed which mitigated the adversary effect of crack on cell performance/durability. (5) The crack at open end showed some deterioration manifested by a small oxidation zone in the vicinity of the crack. Wide spectrum of imaging techniques were surveyed and evaluated to detect tubular SOFC defects. Optical methods, with and without assistance of expression technique, were applied to detect all kinds of defects. Thermograph method in combination of CO2 leak, ultra-sound and electric potential was also extensively evaluated to detect surface and under-surface defects such as short circuit. Based on these works, laser camera has been selected to build the final QC machine vision inspection system. The Gocator laser profile sensor was setup to generate 2D surface intensity images of tubular SOFC surface which were analyzed with Sherlock machine vision software supplied by Teledyne Dalsa. The Gocator output was integrated with the Sherlock software and enabled live images to be imported by a Common Vision Blox driver. The Sherlock software was programmed to detect various surface defects from the surface intensity images generated by the Gocator. These measurements are subsequently used to make pass or fail decisions.

01 COAL, LIGNITE, AND PEAT↗

Single beam Fourier transform digital holographic quantitative phase microscopy

Quantitative phase contrast microscopy reveals thickness or height information of a biological or technical micro-object under investigation. The information obtained from this process provides a means to study their dynamics. Digital holographic (DH) microscopy is one of the most used, state of the art single-shot quantitative techniques for three dimensional imaging of living cells. Conventional off axis DH microscopy directly provides phase contrast images of the objects. However, this process requires two separate beams and their ratio adjustment for high contrast interference fringes. Also the use of two separate beams may make the system more vulnerable to vibrations. Single beam techniques can overcome these hurdles while remaining compact as well. Here, we describe the development of a single beam DH microscope providing whole field imaging of micro-objects. A hologram of the magnified object projected on to a diffuser co-located with a pinhole is recorded with the use of a commercially available diode laser and an arrayed sensor. A Fourier transform of the recorded hologram directly yields the complex amplitude at the image plane. The method proposed was investigated using various phase objects. It was also used to image the dynamics of human red blood cells in which sub-micrometer level thickness variation were measurable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DESIGN OF VISIBLE DIAGNOSTIC BEAMLINE FOR NSLS2 STORAGE RING

A visible synchrotron light monitor (SLM) beam line has been designed at the NSLS2 storage ring, using the bending magnet radiation. A retractable thin absorber will be placed in front of the first mirror to block the central x-rays. The first mirror will reflect the visible light through a vacuum window. The light is guided by three 6-inch diameter mirrors into the experiment hutch. In this paper, we will describe design work on various optical components in the beamline. The ultra high brightness NSLS-II storage ring is under construction at Brookhaven National Laboratory. It will have 3GeV, 500mA electron beam circulating in the 792m ring, with very low emittance (0.9nm.rad horizontal and 8pm.rad vertical). The ring is composed of 30 DBA cells with 15 fold symmetry. Three damping wigglers will be installed in long straight sections 8, 18 and 28 to lower the emittance. While electrons pass through the bending magnet, synchrotron radiation will be generated covering a wide spectrum. There are other insertion devices in the storage ring which will generate shorter wavelength radiation as well. Synchrotron radiation has been widely used as diagnostic tool to measure the transverse and longitudinal profile. Three synchrotron light beam lines dedicated for diagnostics are under design and construction for the NSLS-II storage ring: two x-ray beam lines (pinhole and CRL) with the source points from Cell 22 BM{_}A (first bending in the DBA cell) and Cell22 three-pole wiggler; the third beam line is using visible part of radiation from Cell 30 BM{_}B (second bending magnet from the cell). Our paper focuses on the design of the visible beam line - SLM.

43 PARTICLE ACCELERATORS↗

Development of a position–velocity–time-modulated two-dimensional ion beam figuring system for synchrotron x-ray mirror fabrication

With the rapid evolution of synchrotron x-ray sources, the demand for high-quality precision x-ray mirrors has greatly increased. Single nanometer shape accuracy is required to keep imaging capabilities at the diffraction limit. Ion beam figuring (IBF) has been used frequently for ultra-precision finishing of mirrors, but achieving the ultimate accuracy depends on three important points: careful alignment, accurate dwell time calculation and implementation, and accurate optical metrology. The Optical Metrology Group at National Synchrotron Light Source II has designed and built a position–velocity–time-modulated two-dimensional IBF system (PVT-IBF) with three novel characteristics: (1) a beam footprint on the mirror was used as a reference to align the coordinate systems between the metrology and the IBF hardware; (2) the robust iterative Fourier transform-based dwell time algorithm proposed by our group was applied to obtain an accurate dwell time map; and (3) the dwell time was then transformed to velocities and implemented with the PVT motion scheme. In this study, the technical aspects of the PVT-IBF systems are described in detail, followed by an experimental demonstration of the figuring results. In our first experiment, the 2D RMS in a 50mm×5mm clear aperture was reduced from 3.4 to 1.1 nm after one IBF run. In our second experiment, due to a 5 mm pinhole installed in front of the source, the 2D RMS in a 50mm×5mm clear aperture was reduced from 39.1 to 1.9 nm after three IBF runs, demonstrating that our PVT-IBF solution is an effective and deterministic figuring process.

47 OTHER INSTRUMENTATION↗

Radiating Shock Properties in the Z-pinch Dynamic Hohlraum

The Z-pinch dynamic hohlraum is a high-power x-ray source used for a variety of high energy-density physics applications including high temperature opacity measurements and inertial confinement fusion (ICF). The system consists of a tungsten wire-array Z pinch that implodes onto a low-density CH{sub 2} foam launching a radiating shock that heats the hohlraum to radiation temperatures >200 eV. The temperature and density evolution of this shock have been inferred through the measurement of time- and space-resolved line emission from Si atoms locally doped in the CH{sub 2} foam. The observed emission spectra are analyzed through comparison to collisional-radiative calculations that include a detailed treatment of line-shapes and the effect of non-local radiation on the atomic level populations. As a complement to the detailed spectral data, the radial and azimuthal distribution of the axially directed shock emission is recorded with time-gated x-ray pinhole images that provide information on the spatial profile of the shock conditions. Together with broadband x-ray power measurements, these data provide a comprehensive suite of information to determine the shock dynamics and associated energetics of the Z-pinch dynamic hohlraum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Throughput In-Line Coating Metrology Development for Solid Oxide Fuel Cell Manufacturing

Coatings play key roles in solid oxide fuel cell (SOFC) stack durability. For example, diffusion barrier coatings on Cr-containing interconnect and balance of plant (BOP) components protect electrodes from Cr poisoning over the long operational lifetimes (>10,000 hours) of the fuel cell stack. Common defects in coatings, such as cracks, pinholes, and porosity, result in a failure to protect the electrodes, resulting in shorter operational lifetime and thus higher cost. It is very unlikely, even in the best coating process, that all these defects can be mitigated, hence identifying critical defects in parts, and removing defective parts from production before they can damage the stack, becomes paramount. Furthermore, these quality control techniques must be operational in the production/assembly line (in-line), i.e., high throughput and non-destructive, and cost effective. Redox Power Systems, LLC (Redox) together with the National Renewable Energy Laboratory (NREL) developed much needed high throughput, in-line metrology techniques for protective coatings. The overall goal of the project is to lower cost while increasing robustness, reliability, and endurance of SOFC stacks. To accomplish this, we had several objectives, including: to identify key coating and substrate defects that lead to coating failure through the use of detailed characterization methods (e.g., microscopy, XRD, EDS, electrochemistry); to assess capabilities of in-line metrology techniques, e.g., optical profilometry (Redox) and thermography (NREL), to probe these defects, or evidence thereof; demonstrate long-term performance of “defect-free” protective coatings, as identified by in-line metrology, in solid oxide fuel cell (SOFC) stack operation. In the first part of this project, the ability to identify key defects expected to lead to coating and SOFC degradation using in-line metrology tools were evaluated. Coated interconnect samples with controlled defect types and populations were tested under conditions similar to SOFC operation, followed by detailed post-test analysis to reveal the defects responsible for observed degradation. In the second part of the project, the optimal in-line metrology techniques and methodologies were used to map the defect distribution in full-size interconnects with critical defects intentionally allowed to exist in some cases. These interconnects underwent SOFC testing for extended periods (up to ~3,000 hours) followed by post-test analysis to evaluate the effectiveness of in-line metrology techniques in mitigating MCO coating related degradation. Key accomplishments in this project included the following: Demonstrated ASR of < 0.05 ohm-cm 2 at 650 °C for 1,000 hours with low defect (determined by in-line metrology) interconnect samples (average ASR=37 milliohms-cm 2 after over 1,000 hours). Demonstrated that low defect coatings on interconnects (as screened using in-line metrology) have low volatilization of chromium at ~650 °C for 1,000 hours as detected using Cr-getter material (< 5 at% increase above baseline); 1022 hour duration tests under humidified, elevated temperature (750 °C rather than 650 °C) compared a base case against different coating thicknesses. Demonstrated capability to identify initial key defects of interest with in-line metrology techniques using up to 8 cm by 10 cm having coatings with and without intentional defects of interest using thermal imaging and optical profilometry. Correlated key defects identified using metrology techniques with observed coating performance (e.g., ASR and Cr volatility). Conducted several 4 cm by 4 cm cell tests using MCO-interconnects that were pre-screened using some of the metrology techniques developed in the project (e.g., optical profilometry). An analysis of ASR measurements were able to show that defect-free coatings resulted in the anticipated performance in the cell tests.

01 COAL, LIGNITE, AND PEAT↗

Influence of evaporation rate and chamber pressure on the FUV reflectance and physical characteristics of aluminum films

Space telescopes for studying astrophysical phenomena from the far ultraviolet (FUV) to the near infrared (NIR) require durable mirror coatings with high and uniform reflectance over a very broad spectral region. While coatings for the optical and NIR region are well developed with proven performance, the FUV band presents significant challenges, particularly below 115 nm. Recent developments in physical vapor deposition (PVD) coating processes of aluminum mirrors that are protected with a metal-fluoride overcoat to prevent oxidation (such as LiF, MgF2, or AlF3) have improved reflectance in the FUV. While the emphasis in these studies has been placed on improving the deposition conditions of the metal-fluoride overcoats, less attention has been devoted to how deposition parameters (such as vacuum conditions or deposition rates) may affect the quality of the aluminum mirrors. This paper presents characterization of Al+MgF2 coupons made by flash evaporation of aluminum followed by resistive evaporation of MgF2. Samples were manufactured under a variety of processing conditions and the relationship between processing variables and mirror FUV reflectivity is analyzed. Performance characterization was based on the measured near-normal reflectance in the FUV (90-180 nm), and normal-incidence transmittance in the visible was done to analyze the possible presence of pinholes in the mirror. We demonstrated pinhole-free Al/MgF2 mirrors deposited at room temperature with a reflectivity of 0.91 at 122 nm wavelength. This reflectivity enhancement was achieved solely through parameter optimization.

Manuel A. Quijada↗