Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance benchmark”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Degradation in Photovoltaic Encapsulant Transmittance: Results of the Second PVQAT TG5 Artificial Weathering Study

The optical degradation of encapsulants from ultraviolet (UV) radiation has historically resulted in a significant loss in performance throughout the life of a photovoltaic (PV) module. International Electrotechnical Commission (IEC) test methods have recently been developed to screen for PV encapsulants prone to loss in optical performance. The present study was performed to benchmark polymeric packaging materials relative to IEC 62788-1-4 (covering the measurement of optical transmittance) and IEC 62788-1-7 (on the durability of transmittance), provide feedback toward improvement of the methods, and develop insight regarding optical degradation. Contemporary materials were examined, including poly(ethylene-co-vinyl acetate) (EVA), thermoplastic polyolefin (TPO), polyolefin elastomer (POE), and polyvinyl butyral (PVB) encapsulants; a poly(ethene-co-tetrafluoroethene)/poly(ethylene terephthalate) (ETFE/PET) transparent backsheet; and a polystyrene (PS) working reference material. The use of silica-, specialty-, and rolled-glass was also compared in laminated coupons. Specimen size was separately examined from 2.5 to 12.5 cm. Weathering was performed with a xenon source, using IEC TS 62788-7-2 methods A2, A3, A4, and A5 (chamber temperature of 55 degrees C, 65 degrees C, 75 degrees C, or 85 degrees C), respectively. Characterizations were made using a UV-visible-near-infrared (UV-VIS-NIR) spectrophotometer (transmittance and reflectance, with and without an integrating sphere), a UV-VIS fluorescence spectrophotometer, a camera, and an optical microscope. Performance was analyzed, including solar weighted transmittance, yellowness index, UV cut-off wavelength, and haze (scattering). Separate Arrhenius analyses were performed to assess retention of transmittance and changes in yellowness index. The activation energy for both characteristics was found to range from 15-80 kJ mol-1, with an average of 48 kJ mol-1, similar to the average of 45 kJ mol-1 identified in the previous international PV Quality Assurance Task Force (PVQAT) Task Group 5 (TG5) study of more traditional encapsulants. The separate degradation modes of discoloration and scattering were distinguished in the encapsulants using a comprehensive spectral characterization. Based on these results, the IEC 62788-1-7 pass/fail criteria of 5% change in transmittance was confirmed to identify a known bad encapsulant.

durability↗

Anomaly Identification of Synchronized Voltage Waveform for Situational Awareness of Low Inertia Systems

Inverter-based resources (IBRs) such as photovoltaics (PVs), wind turbines, and battery energy storage systems (BESSs) are widely deployed in low-carbon power systems. However, these resources typically do not provide the inertia needed for grid stability, resulting in a low-inertia power system. IBRs and lack of inertia have been known to cause anomalies such as waveform distortions and wideband oscillations in power systems due to the limited inertia level, leading to increased generation trips and load shedding. Here, to achieve effective anomaly identification, this paper proposes a synchro-waveform-based algorithm utilizing real-time synchronized voltage waveform measurements from waveform measurement units (WMUs). In the proposed method, different physical characteristics, as well as statistical features, are extracted from synchronized voltage waveform measurements to filter anomalies. Then, the anomaly identification approach based on the random forest is developed and deployed into the FNET/GridEye system considering trade-offs among accuracy, computational burden, and deployment cost. Moreover, four WMUs are specially designed and deployed on Kauai Island to receive instantaneous synchronized voltage waveform measurements. To verify the performance of the proposed algorithm, different experiments are carried out with collected field test data. The result demonstrates that the performance of the proposed synchro-waveform-based anomaly categorization algorithm can accurately identify anomalies 95.35% of the time, which has comparable performance among benchmarking algorithms.

Situational awareness↗

Verification of the AGREE and Serpent for the steady state HTR-10 benchmark problems

This paper provides results from steady state HTR-10 benchmark calculations performed using AGREE and Serpent that are compared to experimental results as well as calculations performed by INET. The purpose of completing this benchmark is to validate AGREE and Serpent for the prediction of HTGR operation so that they may ultimately be used to support licensing and deployment efforts of advanced reactors. The benchmark consists of several problems ranging from control rod worth calculations to k{sub eff} calculations at various temperatures. Overall, AGREE and Serpent show good agreement with the reference solutions and are effectively able to predict HTGR operation for a variety of steady state cases. The largest difference from the reference was for the initial core single rod worth, which is possibly due to the larger core helium cavity causing inaccuracies in the diffusion calculation whereas the control rod worth determined by Serpent and AGREE is much closer to the reference result for the full core loading. Moreover, in every benchmark problem, increasing the number of energy groups in the cross sections results in improved agreement of the AGREE result with the reference, although it also causes an increase in computation time. For problems with experimental data available, the accuracy of results generated by Serpent and AGREE is comparable to results obtained by other benchmark participants. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pebble Tanker Model for Nuclear Criticality Safety Needs

This report documents a study performed to investigate the requirements for criticality safety benchmark experiments for high-assay, low-enriched uranium (HALEU) fuel in transportation applications. In this work, an exploratory application model, the “Pebble Tanker,” was developed to represent TRISO fuel in a transportation scenario for an analysis of the validation basis in industrial quantities. An aspect of the criticality validation process involves assessing the “similarity” between application and experimental benchmark systems through an integral index parameter evaluation. Here, this includes propagating nuclear data uncertainties and calculating a correlation coefficient (hereinafter referred to as “c k ”) to evaluate the similarity of benchmark experiments compared with the application Pebble Tanker model. Finding sufficient critical benchmark experiments allows for the evaluation of bias and bias uncertainty, thus determining the upper subcritical limit (USL) of the transportation package. A target k eff of ~0.94 was used in this work to establish appropriate modeling conditions, reflecting a reasonable estimate for a USL. Two container models were investigated: one with the Hermes-type pebble and one with the Pebble Bed Modular Reactor (PBMR)–type pebble. The models were simplified, considering only fuel, containment structure, and either water or air. This allows a focus on the underlying physics of applications involving TRISO fuel pebbles using the Pebble Tanker model. A crucial consideration is the transport package's ability to safely hold pebbles while flooded, maintaining subcritical conditions. Tools available in the SCALE 6.3.1 suite—the CSAS6-Shift, TSUNAMI-3D-Shift, and TSUNAMI-IP sequences—were employed for neutronics and sensitivity and uncertainty (S/U) analysis of the Pebble Tanker. Findings demonstrated sufficient available critical experiment benchmarks to perform a validation of the Pebble Tanker in the most reactive state, i.e., when the Tanker is flooded.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

h5bench: A unified benchmark suite for evaluating HDF5 I/O performance on pre‐exascale platforms

Summary Parallel I/O is a critical technique for moving data between compute and storage subsystems of supercomputers. With massive amounts of data produced or consumed by compute nodes, high‐performant parallel I/O is essential. I/O benchmarks play an important role in this process; however, there is a scarcity of I/O benchmarks representative of current workloads on HPC systems. Toward creating representative I/O kernels from real‐world applications, we have created h5bench , a set of I/O kernels that exercise hierarchical data format version 5 (HDF5) I/O on parallel file systems in numerous dimensions. Our focus on HDF5 is due to the parallel I/O library's heavy usage in various scientific applications running on supercomputing systems. The various tests benchmarked in the h5bench suite include I/O operations (read and write), data locality (arrays of basic data types and arrays of structures), array dimensionality (one‐dimensional arrays, two‐dimensional meshes, three‐dimensional cubes), I/O modes (synchronous and asynchronous). In this paper, we present the observed performance of h5bench executed along several of these dimensions on existing supercomputers (Cori and Summit) and pre‐exascale platforms (Perlmutter, Theta, and Polaris). h5bench measurements can be used to identify performance bottlenecks and their root causes and evaluate I/O optimizations. As the I/O patterns of h5bench are diverse and capture the I/O behaviors of various HPC applications, this study will be helpful to the broader supercomputing and I/O community.

97 MATHEMATICS AND COMPUTING↗

International collaboration framework for the calculation of performance loss rates: Data quality, benchmarks, and trends (towards a uniform methodology)

Abstract The IEA PVPS Task 13 group, experts who focus on photovoltaic performance, operation, and reliability from several leading R&D centers, universities, and industrial companies, is developing a framework for the calculation of performance loss rates of a large number of commercial and research photovoltaic (PV) power plants and their related weather data coming across various climatic zones. The general steps to calculate the performance loss rate are (i) input data cleaning and grading; (ii) data filtering; (iii) performance metric selection, corrections, and aggregation; and finally, (iv) application of a statistical modeling method to determine the performance loss rate value. In this study, several high‐quality power and irradiance datasets have been shared, and the participants of the study were asked to calculate the performance loss rate of each individual system using their preferred methodologies. The data are used for benchmarking activities and to define capabilities and uncertainties of all the various methods. The combination of data filtering, metrics (performance ratio or power based), and statistical modeling methods are benchmarked in terms of (i) their deviation from the average value and (ii) their uncertainty, standard error, and confidence intervals. It was observed that careful data filtering is an essential foundation for reliable performance loss rate calculations. Furthermore, the selection of the calculation steps filter/metric/statistical method is highly dependent on one another, and the steps should not be assessed individually.

14 SOLAR ENERGY↗

Measurement and Simulation of the Magnetic Fields from a 555 Timer Integrated Circuit Using a Quantum Diamond Microscope and Finite-Element Analysis

Quantum diamond microscope (QDM) magnetic field imaging is an emerging interrogation and diagnostic technique for integrated circuits (ICs). To date, the ICs measured with a QDM have been either too complex for us to predict the expected magnetic fields and benchmark the QDM performance or too simple to be relevant to the IC community. In this paper, we establish a 555 timer IC as a “model system” to optimize QDM measurement implementation, benchmark performance, and assess IC device functionality. To validate the magnetic field images taken with a QDM, we use a spice electronic circuit simulator and finite-element analysis (FEA) to model the magnetic fields from the 555 die for two functional states. Furthermore, we compare the advantages and the results of three IC-diamond measurement methods, confirm that the measured and simulated magnetic images are consistent, identify the magnetic signatures of current paths within the device, and discuss using this model system to advance QDM magnetic imaging as an IC diagnostic tool.

74 ATOMIC AND MOLECULAR PHYSICS↗

Neutronics and Thermo-Fluids Simulation of Generic Pebble-Bed Fluoride-Salt-Cooled High-Temperature Reactor

The fluoride-salt-cooled high-temperature reactor (FHR) is one of the advanced reactors that has been attracting considerable interest from both the research community and the nuclear industry. To help facilitate the nuclear community's familiarity with the FHR, Kairos Power has developed a generic FHR (gFHR) benchmark. In the research performed here, this benchmark was used to assess innovative modeling methods that combine stochastic and deterministic computer codes to perform the design and analysis of the gFHR. Further, the Monte Carlo code Serpent 2 was used to generate few-group cross sections that were then used in the neutron diffusion and thermal-fluids code AGREE to perform full-core neutronics and thermal-fluids steady-state and transient core analysis. The Argonne National Laboratory code SAM was then used to model the gFHR system and to simulate the load-follow operation of the gFHR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Viable New Strategy for the Discovery of Peptide Proteolytic Cleavage Products in Plant-Microbe Interactions

Small peptides that are proteolytic cleavage products (PCPs) of less than 100 amino acids are emerging as key signaling molecules that mediate cell-to-cell communication and biological processes that occur between and within plants, fungi, and bacteria. Yet, the discovery and characterization of these molecules is largely overlooked. Today, selective enrichment and subsequent characterization by mass spectrometry–based sequencing offers the greatest potential for their comprehensive characterization, however qualitative and quantitative performance metrics are rarely captured. Herein, we addressed this need by benchmarking the performance of an enrichment strategy, optimized specifically for small PCPs, using state-of-the-art de novo–assisted peptide sequencing. As a case study, we implemented this approach to identify PCPs from different root and foliar tissues of the hybrid poplar Populus × canescens 717-1B4 in interaction with the ectomycorrhizal basidiomycete Laccaria bicolor . In total, we identified 1,660 and 2,870 Populus and L. bicolor unique PCPs, respectively. Qualitative results supported the identification of well-known PCPs, like the mature form of the photosystem II complex 5-kDa protein (approximately 3 kDa). A total of 157 PCPs were determined to be significantly more abundant in root tips with established ectomycorrhiza when compared with root tips without established ectomycorrhiza and extramatrical mycelium of L. bicolor . These PCPs mapped to 64 Populus proteins and 69 L. bicolor proteins in our database, with several of them previously implicated in biologically relevant associations between plant and fungus.

59 BASIC BIOLOGICAL SCIENCES↗

LLM-Inference-Bench: Inference Benchmarking of Large Language Models on AI Accelerators

Large Language Models (LLMs) have propelled groundbreaking advancements across several domains and are commonly used for text generation applications. However, the computational demands of these complex models pose significant challenges, requiring efficient hardware acceleration. Benchmarking the performance of LLMs across diverse hardware platforms is crucial to understanding their scalability and throughput characteristics. We introduce LLM-Inference-Bench, a comprehensive benchmarking suite to evaluate the hardware inference performance of LLMs. We thoroughly analyze diverse hardware platforms, including GPUs from Nvidia and AMD and specialized AI accelerators, Intel Habana and SambaNova. Our evaluation includes several LLM inference frameworks and models from LLaMA, Mistral, and Qwen families with 7B and 70B parameters. Our benchmarking results reveal the strengths and limitations of various models, hardware platforms, and inference frameworks. We provide an interactive dashboard to help identify configurations for optimal performance for a given hardware platform.

Chitty-Venkata, Krishna Teja↗

Occupant-Centric key performance indicators to inform building design and operations

Building performance indicators are widely used to guide building design and track and benchmark operational performance. Traditional building performance indicators mostly focus on the energy efficiency perspective. As occupants are the primary building service recipients in residential and most commercial buildings, their comfort and wellbeing are crucial. As such, this study first identified significant attributes of occupant-centric key performance indicators (KPIs) and analyzed the diverse factors that should be considered in formulating an occupant-centric KPI. Then a suite of occupant-centric KPIs were synthesized from the review and enhancement of existing occupant-related performance metrics. The proposed occupant KPIs represent the occupant lens on three integrative aspects of building performance: resource use (including energy and water), indoor environmental quality, and human–building interactions. A simulation-based case study was conducted to demonstrate how occupant-centric KPIs can be used to quantify the impacts of building operation changes from the occupants’ point of view. Highlights: Occupant-centric metrics are currently ad hoc and limited, yet crucial to inform building design and operations. Literature was reviewed to reveal the state-of-the-art and gaps of occupant-centric metrics. A suite of occupant-centric key performance indicators (KPIs) covering five groups of building services were synthesized. Proposed occupant KPIs represent three aspects of performance: resource use and demand, occupant comfort and health, and human–building interactions. A case study using whole building simulation was conducted to demonstrate the use of occupant-centric KPIs in evaluating building operations during a power outage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Portability of Automotive Workload: A Case Study with the Points-to-Image Kernel in SYCL on Heterogeneous Computing Platforms

SYCL is a promising programming model for heterogenous computing across vendors’ devices. In this paper, we study whether SYCL can be applied to an automotive workload and its portability on heterogeneous computing platforms. We explain the automotive benchmark, describe our implementations and optimizations of the benchmark, and evaluate the performance of the benchmarks using SYCL and other programming models on heterogeneous computing devices. The study also allows us to have a better understanding of portability of the benchmark across these platforms.

Jin, Zheming↗

Reassessment of PHDS Fulcrum40h High Purity Germanium (HPGe) Detector System Performance

This report presents a comprehensive evaluation of the updated PHDS Fulcrum40h High Purity Germanium (HPGe) detector system, benchmarking its performance, usability, and software capabilities against the current National Nuclear Security Administration (NNSA) Nuclear Emergency Support Team (NEST) HPGe Detector System Requirements Document. Systematic measurements were conducted using a single Fulcrum40h detector to assess key parameters including gamma efficiency and resolution, neutron detection efficiency, gamma pulse-pileup response, and gamma-to-neutron crosstalk. The Fulcrum40h system, acquired in August 2022, has undergone recent updates by PHDS to address deficiencies identified following the initial NEST requirements release. The results provide critical insights into the detector’s operational capabilities and compliance with NNSA NEST standards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmark Calculation for BEAVRS Cycles 1 and 2 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

This study performed the benchmark calculation for BEAVRS to validate the SCALE 6.3/Polaris–PARCS v3.4.2 code package with the ENDF/B-VII.1 56-group library, comparing the simulated results with the measured data. The benchmark results will be used in evaluating uncertainties of the SCALE/Polaris–PARCS code package for pressurized water reactor physics analysis for key nuclear parameters such as reactivity, control bank worth, temperature coefficients, and pin and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris as well as GenPMAXS and PARCS. Additionally, detailed information is provided for all the input and output files produced for the benchmark calculations. The benchmark results are summarized herein so that they can be used in evaluating uncertainties for key nuclear parameters with other benchmark results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Questionable Benchmarks [Slides]

An investigation and initial review of ‘questionable benchmarks’ was performed at LANL. Multiple methods were used, including machine learning techniques, to identify 'questionable benchmarks' and/or benchmarks with low uncertainties. Those benchmarks were then reviewed for obvious errors. This is not a recommendation to ICSBEP, but can be used as a starting point for a more comprehensive review. A journal paper is being written on this work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗