Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Path Planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A method to dynamically balance intensity modulated radiotherapy dose between organs-at-risk

The IMRT treatment planning process typically follows a path that is based on the manner in which the planner interactively adjusts the target and organ-at-risk (OAR) constraints and priorities. The time-intensive nature of this process restricts the planner from fully understanding the dose trade-off between structures, making it unlikely that the resulting plan fully exploits the extent to which dose can be redistributed between anatomical structures. Multiobjective Pareto optimization has been used in the past to enable the planner to more thoroughly explore alternatives in dose trade-off by combining pre-generated Pareto optimal solutions in real time, thereby potentially tailoring a plan more exactly to requirements. However, generating the Pareto optimal solutions can be nonintuitive and computationally time intensive. The author presents an intuitive and fast non-Pareto approach for generating optimization sequences (prior to planning), which can then be rapidly combined by the planner in real time to yield a satisfactory plan. Each optimization sequence incrementally reduces dose to one OAR at a time, starting from the optimization solution where dose to all OARs are reduced with equal priority, until user-specified target coverage limits are violated. The sequences are computationally efficient to generate, since the optimization at each position along a sequence is initiated from the end result of the previous position in the sequence. The pre-generated optimization sequences require no user interaction. In real time, a planner can more or less instantaneously visualize a treatment plan by combining the dose distributions corresponding to user-selected positions along each of the optimization sequences (target coverage is intrinsically maintained in the combination). Interactively varying the selected positions along each of the sequences enables the planner to rapidly understand the nature of dose trade-off between structures and, thereby, arrive at a suitable plan in a short time. This methodology is demonstrated on a prostate cancer case and olfactory neuroblastoma case.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Guam Energy Strategies

In 2024, GPA met approximately 12%1 of electricity sales with renewable energy, up from 6% in 20202. GPA's 2021 Integrated Resource Plan (IRP) charts a potential path to meeting 100% renewable electricity by 2040. Since achieving 100% will require significant infrastructure investment to transition the power system to renewable electricity generation, Guam Energy Strategies is exploring technology options, locations, resource adequacy, rate impacts, and other considerations for reaching Guam's energy goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MO-FG-CAMPUS-JeP1-04: Evaluating DECT Vs SECT Range Differences in Proton Therapy Using Clinical Data

Purpose: Range uncertainty from X-ray CT number conversion to stopping power ratio (SPR) is one of the key factors limiting the potential of proton therapy. The large margins required for deep seated tumors degrade the organ sparing achievable with the technology. Of interest is the application of dual energy CT (DECT) to SPR estimation. In this planning study proton range differences between SECT and DECT have been quantified for brain cases. Methods: A last generation dual source DECT scanner was used to acquire SECT (150 kVp with Sn filtration) and DECT (additionally 90 kVp) scans of phantoms and 5 head trauma patients, acting as surrogate cancer patients. Phantom materials were characterized in terms of SPR in a particle beam to obtain reference values. IMPT treatment plans were generated on the basis of SECT and DECT SPR images for hypothetical brain tumors using a short and a long beam path. Range differences between SECT and DECT from plan recalculations were evaluated in beam-eye-view (BEV) by comparing the 80% isodose. Results: For the 18 phantom materials the SECT RMS SPR errors were 2.6% compared to 1.1% for DECT. Group median relative range differences between SECT and DECT plans were −1.0% for the short beam path over the 5 patients investigated in this study. For the long beam path the median difference was −1.4%. These relative range differences corresponded to −0.5 mm and −1.4 mm shifts respectively. Conclusion: This is the first study performing proton therapy treatment planning on DECT patient images. Important range differences of more than 1 mm were observed between SECT and DECT treatment plans, and DECT SPR accuracy was found superior on the basis of phantom measurements. While the patients investigated in this study did not have brain tumors, the findings we observed should apply to cancer patients. Deutsche Forschungsgemeinschaft (MAP); Bundesministerium fur Bildung und Forschung (01IB13001)

60 APPLIED LIFE SCIENCES↗

SU-E-T-266: Proton PBS Plan Design and Robustness Evaluation for Head and Neck Cancers

Purpose: To describe a newly designed proton pencil beam scanning (PBS) planning technique for radiotherapy of patients with bilateral oropharyngeal cancer, and to assess plan robustness. Methods: We treated 10 patients with proton PBS plans using 2 posterior oblique field (2F PBS) comprised of 80% single-field uniform dose (SFUD) and 20% intensity-modulated proton therapy (IMPT). All patients underwent weekly CT scans for verification. Using dosimetric indicators for both targets and organs at risk (OARs), we quantitatively compared initial plans and verification plans using student t-tests. We created a second proton PBS plan for each patient using 2 posterior oblique plus 1 anterior field comprised of 100% SFUD (3F PBS). We assessed plan robustness for both proton plan groups, as well as a photon volumetric modulated arc therapy (VMAT) plan group by comparing initial and verification plans. Results: The 2F PBS plans were not robust in target coverage. D98% for clinical target volume (CTV) degraded from 100% to 96% on average, with maximum change Δ D98% of −24%. Two patients were moved to photon VMAT treatment due to insufficient CTV coverage on verification plans. Plan robustness was especially weak in the low-anterior neck. The 3F PBS plans, however, demonstrated robust target coverage, which was comparable to the VMAT photon plan group. Doses to oral cavity were lower in the Proton PBS plans compared to photon VMAT plans due to no lower exit dose to the oral cavity. Conclusion: Proton PBS plans using 2 posterior oblique fields were not robust for CTV coverage, due to variable positioning of redundant soft tissue in the posterior neck. We designed 3-field proton PBS plans using an anterior field to avoid long heterogeneous paths in the low neck. These 3-field proton PBS plans had significantly improved plan robustness, and the robustness is comparable to VMAT photon plans.

60 APPLIED LIFE SCIENCES↗

A novel lateral disequilibrium inclusive (LDI) pencil-beam based dose calculation algorithm: Evaluation in inhomogeneous phantoms and comparison with Monte Carlo calculations

Purpose: Pencil-beam (PB) based dose calculation for treatment planning is limited by inaccuracies in regions of tissue inhomogeneities, particularly in situations with lateral electron disequilibrium as is present at tissue/lung interfaces. To overcome these limitations, a new ''lateral disequilibrium inclusive'' (LDI) PB based calculation algorithm was introduced. In this study, the authors evaluated the accuracy of the new model by film and ionization chamber measurements and Monte Carlo simulations. Methods: To validate the performance of the new LDI algorithm implemented in Corvus 09, eight test plans were generated on inhomogeneous thorax and pelvis phantoms. In addition, three plans were calculated with a simple effective path length (EPL) algorithm on the inhomogeneous thorax phantom. To simulate homogeneous tissues, four test plans were evaluated in homogeneous phantoms (homogeneous dose calculation). Results: The mean pixel pass rates and standard deviations of the gamma 4%/4 mm test for the film measurements were (96{+-}3)% for the plans calculated with LDI, (70{+-}5)% for the plans calculated with EPL, and (99{+-}1)% for the homogeneous plans. Ionization chamber measurements and Monte Carlo simulations confirmed the high accuracy of the new algorithm (dose deviations {<=}4%; gamma 3%/3 mm {>=}96%)Conclusions: LDI represents an accurate and fast dose calculation algorithm for treatment planning.

60 APPLIED LIFE SCIENCES↗

PROTOPLASMA - Proton-driven plasma-wakefield experiment at Fermilab: Stages and approach

Generation of TeV-scale electron beams using conventional RF technology appears expensive for building the next generation of colliders. Proton-driven plasma-wakefield acceleration of electrons promises an alternative route to generate TeV-scale electron beams using existing proton machines. PROTOPLASMA is the proposed R and D project at Fermilab that plans to use a proton beam driven plasma-wakefield to accelerate electrons. The project is planned in stages with the project's path guided by simulations. First, a 60-120 GeV proton beam will be injected into 1-2 meters of plasma to observe selfmodulation instability in the proton beam. Next, an injected 5 MeV electron beam will be accelerated by the plasma. In this paper, we report on the basic project plan and outline our staged approach. We report on first simulation results that show self-modulation of a proton bunch and discuss beam optics requirements and other limits.

43 PARTICLE ACCELERATORS↗

Heuristic optimization of the scanning path of particle therapy beams

Quasidiscrete scanning is a delivery strategy for proton and ion beam therapy in which the beam is turned off when a slice is finished and a new energy must be set but not during the scanning between consecutive spots. Different scanning paths lead to different dose distributions due to the contribution of the unintended transit dose between spots. In this work an algorithm to optimize the scanning path for quasidiscrete scanned beams is presented. The classical simulated annealing algorithm is used. It is a heuristic algorithm frequently used in combinatorial optimization problems, which allows us to obtain nearly optimal solutions in acceptable running times. A study focused on the best choice of operational parameters on which the algorithm performance depends is presented. The convergence properties of the algorithm have been further improved by using the next-neighbor algorithm to generate the starting paths. Scanning paths for two clinical treatments have been optimized. The optimized paths are found to be shorter than the back-and-forth, top-to-bottom (zigzag) paths generally provided by the treatment planning systems. The gamma method has been applied to quantify the improvement achieved on the dose distribution. Results show a reduction of the transit dose when the optimized paths are used. The benefit is clear especially when the fluence per spot is low, as in the case of repainting. The minimization of the transit dose can potentially allow the use of higher beam intensities, thus decreasing the treatment time. The algorithm implemented for this work can optimize efficiently the scanning path of quasidiscrete scanned particle beams. Optimized scanning paths decrease the transit dose and lead to better dose distributions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Department of Homeland Security Summer Internship

My time at Lawrence Livermore National Laboratory (LLNL) has been one of the most rewarding and exciting experiences of my life. When I first applied for a Department of Homeland Security (DHS) internship I was concerned that my major in Mass Communications and Emergency Management would not be suited for the hard science environment. Thankfully DHS and my mentor, Brooke Buddemeier, demonstrated that the skills and knowledge I possess are critical for the successful integration of good science into Homeland Security and emergency response, and allowed me the opportunity to work on an exciting project. This paper intends to give an overview of my experiences while at LLNL, explain the project I have been a part of, explain my specific role within that project, discuss my achievements, explain how my internship has changed where I plan to take my career path, and, finally, discuss how I believe DHS can enhance their future internship programs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Wasatch Solar Project Final Report

The Wasatch Solar Project was a collaborative effort to conduct stakeholder engagement and provide technical assistance and analysis to support solar market development in Utah. The Wasatch Solar Project addressed four topic areas: 1) technical analysis to inform an assessment of the net benefits and costs of solar in Utah; 2) development of a 10-Year Solar Deployment Plan to create a clear path for continued solar deployment in Utah; 3) demonstration of the costs and resiliency benefits of solar and storage for resiliency at emergency response facilities or public facilities; and 4) technical assistance to create a replicable Commercial Property Assessed Clean Energy (C-PACE) financing program in Utah. The Wasatch Solar Project identified that new technical new technical challenges arise as nascent markets grow to higher penetrations of solar, requiring more detailed interconnection standards and improved efficiency in the interconnection process; that it is difficult for entities served by utilities that do not collect hourly usage data to assess the economic value of solar and storage; that despite significant resiliency benefits, the high cost of battery storage limits its adoption at healthcare and emergency response facilities in states like Utah that have low electricity rates; that administration of C-PACE financing at a local jurisdictional level can be complex, cumbersome, and a barrier to widespread utilization; and that investments in distributed generation can result in long-term savings for utility customers.

14 SOLAR ENERGY↗

Modeling the Grid Integration of Variable Renewable Energy (VRE) Resources

The presentation was given at the November 21-23, 2018 'CEM Days - Integration of Renewables in the Electric Sector: Paths and Challenges to Energy Planning' in Rio de Janeiro, Brazil. It provides a summary of NREL's current modeling approaches, datasets, and considerations for integrating renewables into the power system. It also covers current model method improvement efforts, including our vision for a truly integrated modeling approach.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Anisotropic inelastic materials milestone 2021

The focus on new fuel and cladding models are drivers for several new capabilities at the MOOSE and BISON levels. Since these materials are anisotropic, they require an extension of our inelastic mechanics capabilities, which currently heavily rely on radial return mapping and the assumption of isotropic stiffness. We plan to add additional code paths to support fully anisotropic materials, without degrading the performance for modeling isotropic materials.

42 ENGINEERING↗

Nuclear Materials Management U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO)

In light of the changing Defense Complex mission, the high cost to storing and protecting nuclear materials, and in consideration of scarcity of resources, it is imperative that the U.S. Department of Energy (DOE) owned nuclear materials are managed effectively. The U.S. Department of Energy, National Nuclear Security Administration (NNSA) Strategic Action Plan outlines the strategy for continuing to meet America’s nuclear security goals, meeting the overall mission challenges of DOE and NNSA as well as giving focus to local missions. The mission of the NNSA/NSO Nuclear Materials Management (NMM) Program is to ensure that nuclear material inventories are accurately assessed and reported, future material needs are adequately planned, and that existing Nevada Test Site (NTS) inventories are efficiently utilized, staged, or dispositioned. The NNSA/NSO understands that the NTS has unique characteristics to serve and benefit the nation with innovative solutions to the complex problems involving Special Nuclear Materials, hazardous materials, and multi-agency, integrated operations. The NNSA/NSO is defining infrastructure requirements for known future missions, developing footprint consolidation strategic action plans, and continuing in the path of facility modernization improvements. The NNSA/NSO is striving for the NTS to be acknowledged as an ideal location towards mission expansion and growth. The NTS has the capability of providing isolated, large scale construction and development locations for nuclear power or alternate energy source facilities, expanded nuclear material storage sites, and for new development in “green” technology.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nuclear Materials Management U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO)

In light of the changing Defense Complex mission, the high cost to storing and protecting nuclear materials, and in consideration of scarcity of resources, it is imperative that the U.S. Department of Energy (DOE) owned nuclear materials are managed effectively. The U.S. Department of Energy, National Nuclear Security Administration (NNSA) Strategic Action Plan outlines the strategy for continuing to meet America’s nuclear security goals, meeting the overall mission challenges of DOE and NNSA as well as giving focus to local missions. The mission of the NNSA/NSO Nuclear Materials Management (NMM) Program is to ensure that nuclear material inventories are accurately assessed and reported, future material needs are adequately planned, and that existing Nevada Test Site (NTS) inventories are efficiently utilized, staged, or dispositioned. The NNSA/NSO understands that the NTS has unique characteristics to serve and benefit the nation with innovative solutions to the complex problems involving Special Nuclear Materials, hazardous materials, and multi-agency, integrated operations. The NNSA/NSO is defining infrastructure requirements for known future missions, developing footprint consolidation strategic action plans, and continuing in the path of facility modernization and improvements. The NNSA/NSO is striving for the NTS to be acknowledged as an ideal location towards mission expansion and growth. The NTS has the capability of providing isolated, large scale construction and development locations for nuclear power or alternate energy source facilities, expanded nuclear material storage sites, and for new development in “green” technology.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recent Studies Related to Past Operations at the High Flux Isotope Reactor

During the past year, two topics related to past operations of the High Flux Isotope Reactor (HFIR) were reviewed in response to on-going programs at Oak Ridge National Laboratory (ORNL). Currently, studies are being conducted to determine if HFIR can be converted from high enriched uranium (HEU) fuel to low enriched uranium (LEU). While the basis for conversion is the current performance of the reactor, redesign studies revealed an apparent slight degradation in performance of the reactor over its 40 year lifetime. A second program requiring data from HFIR staff is the Integrated Facility Disposition Project (IFDP). The IFDP is a program that integrates environmental cleanup with modernization and site revitalization plans and projects. Before a path of disposal can be established for discharged HFIR beryllium reflector regions, the reflector components must be classified as to type of waste and specifically, determine if they are transuranic waste.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Studies of Past Operations at the High Flux Isotope Reactor

During the past year, two topics related to past operations of the High Flux Isotope Reactor (HFIR) were reviewed in response to on-going programs at Oak Ridge National Laboratory (ORNL). Currently, studies are being conducted to determine if HFIR can be converted from high enriched uranium (HEU) fuel to low enriched uranium (LEU). While the basis for conversion is the current performance of the reactor, redesign studies revealed an apparent slight degradation in performance of the reactor over its 40 year lifetime. A second program requiring data from HFIR staff is the Integrated Facility Disposition Project (IFDP). The IFDP is a program that integrates environmental cleanup with modernization and site revitalization plans and projects. Before a path of disposal can be established for discharged HFIR beryllium reflector regions, the reflector components must be classified as to type of waste and specifically, determine if they are transuranic waste.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multi-agent motion planning with sporadic communications for collision avoidance

Here, a novel multi-vehicle motion planning and collision avoidance algorithm is proposed and analyzed. The algorithm aims to reduce the amount of onboard calculations and inter-agent communications needed for each vehicle to successfully navigate through an environment with static obstacles and reach their goals. To this end, each agent first calculates a path to the goal by means of an asymptotically optimal rapidly-exploring random tree (RRT*) with respect to the static obstacles. Then, other agents are treated as dynamic obstacles and potential collisions are determined by means of collision cones. Collision cones depend on the position and velocity from other agents and are grown conservatively between inter-agent communications. Based on the available information, each agent determines if a deconfliction maneuver is needed, if it can continue along its current path, or if communication is needed to make a decision about a conflict. With probability one, our algorithm guarantees that the agents keep from colliding with each other. Under an assumption on the existence of a solution for a vehicle to its goal, this algorithm also solves the planning problem with probability one. Simulations illustrate a group of agents successfully reaching their goal configurations and examine how the uncertainty affects the communication frequency of the multi-agent system.

33 ADVANCED PROPULSION SYSTEMS↗

Impact of Using Different Four-Dimensional Computed Tomography Data Sets to Design Proton Treatment Plans for Distal Esophageal Cancer

Purpose: To study the impact of selecting different data sets from four-dimensional computed tomography (4D CT) imaging during proton treatment planning in patients with distal esophageal cancer. Methods and Materials: We examined the effects of changes in 4D CT data set and smearing margins in proton treatment planning for 5 patients with distal esophageal cancer whose diaphragms were in the beam path and could move several centimeters during respiration. Planning strategies based on (1) average, (2) inspiration, and (3) expiration CT were evaluated in terms of their coverage on the internal clinic target volume (ICTV) at the prescribed dose. Results: For Strategy 1, increasing the smearing margin caused an increase in the ICTV prescription dose coverage (PDC) at the end-exhalation phase for all patients, whereas the ICTV PDC decreased for some patients at the end-inhalation phase. For Strategy 2, a smearing margin in the range of 1.0 to 3.5 cm caused the ICTV PDC to remain essentially unchanged, regardless of which phase of 4D CT was used for dose calculation, for all patients. For Strategy 3, the ICTV coverage was adequate for 2 of the 5 patients when a smearing margin of less than 1.0 cm was used, but was not adequate for the other 3 patients regardless of the smearing margin. Conclusion: Using the inspiration CT plus a smearing margin can lead to adequate ICTV coverage in treatment plans for patients with distal esophageal tumors surrounded by tissue that is subject to large changes in density during a proton treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Decarbonization Roadmap: Los Alamos National Laboratory [Slides]

The Net-Zero (NZ) Decarbonization Roadmap builds upon LANL’s storied & innovative energy-related history. It also builds upon existing LANL planning frameworks. The Net Zero Roadmap Framework defines a ‘whole of LANL’ approach for meeting overarching, builds upon existing planning efforts, identifies and prioritizes critical path actions LANL can adapt to meet net & real-time clean electricity targets, and identifies key technological challenges in achieving targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗