Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Parabolic Flight”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Horizontal angular VOR, nystagmus dumping, and sensation duration in spacelab SLS-1 crewmembers

In 1G, the apparent time constant (Td) of postrotatory SPV decay with the head tilted face down is 55% of that with head erect (Te). This phenomenon is called "nystagmus dumping" and has been attributed to G effects on VOR velocity storage. Similarly, postrotatory sensation duration with head tilted (Dd) is 32% of that when head erect (De). In parabolic flight, Te and De are 70% of 1-G values, but a pitch back dumping movement produces no further change. Te, Td, and Dd have not previously been measured in orbital flight. VOR and sensation duration was tested in 4 crewmembers in 4 preflight, 1 inflight (days 4 or 5) and 4 post flight sessions. Bitemporal EOG was recorded with eyes open in darkness. Instructions were to "gaze straight ahead," and indicate when "rotation sensation disappears or becomes ambiguous". Subjects were rotated CW and CCW head erect for 1 min at 120 degrees/s, stopped, and EOG was recorded for another 1 min. This procedure was then used to study dumping, except that immediately after chair stop, subjects pitched their head forward 90 degrees. SPV was calculated using order statistic filtering, and dropouts removed using an iterative model fitting method. Te and Td were determined by logarithmic linear regression of mean SPV for each subject. In orbit, 90 degrees pitch movement produced rapid subjective dumping, but not nystagmus dumping. Dd was noticeably shorter ("almost instantaneous") compared to preflight Dd. Te and Td in orbit were similar to preflight Te for 3/4 subjects (rather than to preflight Td as expected). No consistent VOR gain changes were seen in orbit. Although Te is known to decrease acutely in parabolic flight, a longer time constant was measured in 3/4 subjects after 4-5 days adaptation to weightlessness, suggesting a return of angular velocity storage.

NASA Experiment Number 178072 1/2↗

Extravehicular Activity Testing in Analog Environments: Evaluating the Effects of Center of Gravity and Environment on Human Performance

The EVA Physiology, Systems and Performance (EPSP) Project is performing tests in different analog environments to understand human performance during Extravehicular Activity (EVA) with the aim of developing more safe and efficient systems for lunar exploration missions and the Constellation Program. The project is characterizing human EVA performance in studies using several test beds, including the underwater NASA Extreme Environment Mission Operations (NEEMO) and Neutral Buoyancy Laboratory (NBL) facilities, JSC fs Partial Gravity Simulator (POGO), and the NASA Reduced Gravity Office (RGO) parabolic flight aircraft. Using these varied testing environments, NASA can gain a more complete understanding of human performance issues related to EVA and the limitations of each testing environment. Tests are focused on identifying and understanding the EVA system factors that affect human performance such as center of gravity (CG), inertial mass, ground reaction forces (GRF), suit weight, and suit pressure. The test results will lead to the development of lunar EVA systems operations concepts and design requirements that optimize human performance and exploration capabilities. METHODS: Tests were conducted in the NBL and during NEEMO missions in the NOAA Aquarius Habitat. A reconfigurable back pack with repositionable mass was used to simulate Perfect, Low, Forward, High, Aft and NASA Baseline CG locations. Subjects performed simulated exploration tasks that included ambulation, kneel and recovery, rock pick-up, and shoveling. Testing using POGO, that simulates partial gravity via pneumatic weight offload system and a similar reconfigurable rig, is underway for a subset of the same tasks. Additionally, test trials are being performed on the RGO parabolic flight aircraft. Subject performance was assessed using a modified Cooper-Harper scale to assess operator compensation required to achieve desired performance. All CG locations are based on the assumption of a standardized 6 ft 180 lb subject. RESULTS: The modified Cooper-Harper Scale assesses desired task performance described as performance in a reduced gravity environment as compared to a 1G environment. Modified Cooper-Harper ratings of . 3 indicate no improvements are needed, ratings of 4-6 indicate improvements are desirable, and ratings . 7 indicate improvements are mandatory. DISCUSSION: Differences were noted in suited CH results based on environment at the same CG and suit pressure. Additionally, results suggest that CG location affects unsuited human performance. Subjects preferred locations near their natural CG over those that are high, aft, or a combination of high and aft. Further testing and analyses are planned to compare these unsuited results to suited performance.

Gernhardt, M.L.↗

Relative Bioavailability of Scopolamine Dosage Forms and Interaction with Dextroamphetamine

The NASA Reduced Gravity Office (RGO) uses scopolamine (SCOP) and in combination with dextoamphetamine (DEX) to manage motion sickness symptoms during parabolic flights. The medications are dispensed as custom dosage forms as gelatin capsules. Anecdotal evidence of efficacy suggests that these formulations are unreliable and less efficacious for the treatment of motion sickness. We estimated bioavailability of four different oral formulations used by NASA for the treatment of motion sickness. Twelve healthy, non-smoking subjects between 21and 48 years of age received four treatments on separate days in a randomized fashion; the treatments were 0.8 mg SCOP alone as tablet, 0.8 mg SCOP alone in gel cap, 0.8 mg SCOP and 10 mg DEX as tablets, and 0.8 mg SCOP and 10 mg DEX in gel cap. After each treatment, blood, saliva, and urine samples were collected at scheduled time intervals for 24 h after dosing. Bioavailability and pharmacokinetic parameters were calculated and compared using ANOVA. After administration of SCOP tablets alone, maximum concentration (C(sub max)) and time for maximum concentration (t(sub max)) were 0.26 plus or minus 0.04 ng/mL and 0.71 plus or minus 0.02 h, respectively; volume of distribution, and clearance were 47.6 plus or minus 4.72 L/kg and 23.0 plus or minus 4.58 L/h/kg, respectively. SCOP t(sub max) after administration as gelcaps was significantly longer than that with tablets (1.04 h, p less than 0.05), but no significant differences in other pharmacokinetic parameters of SCOP were observed between the two dosage forms. When coadministered with DEX, the area underneath the concentration versus time curve (AUC) of SCOP was significantly reduced to 0.61 plus or minus 0.09 and 0.64 plus or minus 0.11 ng (raised dot) h/mL after administration as a tablet or gelcap formulation, respectively; SCOP C(sub max) was lower after coadministration with DEX, this difference, however, was not statistically significant. Delayed absorption with gelcaps coupled with reduced bioavailability with DEX coadministration may have resulted in the observed treatment failure with some of these formulations. This could result from failure to reach minimum effective concentrations after treatment with gelcap formulations before parabolic flights. A new nomogram for dosing is proposed for treatment with SCOP gelcaps or SCOP-DEX combination.

Boyd, Jason L.↗

Human Health Countermeasures - Partial-Gravity Analogs Workshop

The experimental conditions that were deemed the most interesting by the HHC Element lead scientists are those permitting studies of the long-term effects of exposure to (a) chronic rotation when supine or in head down tilt (ground-based); and (b) long-radius centrifugation (space based). It is interesting to note that chronic ground based slow rotation room studies have not been performed since the 1960's, when the USA and USSR were investigating the potential use of AG for long-duration space missions. On the other hand, the other partial gravity analogs, i.e., parabolic flight, HUT, suspension, and short-radius centrifugation, have been regularly used in the last three decades (see review in Clément et al. 2015). Based on the workshop evaluations and the scores by the HHC scientific disciplines indicated in tables 3 and 4, simulation of partial G between 0 and 1 should be prioritized as follows: Priority 1. Chronic space-based partial-G analogs: a. Chronic space-based long-radius centrifugation. The ideal scenario would be chronic long-radius centrifugation of cells, animals and humans in a translational research approach - ideally beyond low earth orbit under deep space environmental effects and at various rotations - to obtain different G-effects. In this scenario, all physiological systems could be evaluated and the relationship between physiological response and G level established. This would be the most integrative way of defining, for the first time ever, G-thresholds for each physiological system. b. Chronic space-based centrifugation of animals. Chronic centrifugation of rodents at various G levels in space would allow for determination of AG thresholds of protection for each physiological system. In this case, all physiological systems will be of interest. Intermittent centrifugation will be of secondary interest. c. Chronic space-based centrifugation of cell cultures (RWV). Bioreactor studies of cells and cell cultures of various tissues at various G levels would allow for intracellular investigations of the effects of partial-G. Priority 2. Acute, intermittent space based partial-G analogs: a. Acute, intermittent space-based short radius human centrifugation. Intermittent centrifugation of humans would allow determination of thresholds of AG for protection of astronaut health in space. Priority 3. Chronic ground-based partial-G analogs: a. Chronic centrifugation of supine or head-down tilted humans. b. Chronic head-up tilt in humans. c. Chronic head-out graded dry immersion in humans. d. Chronic partial suspension of rodents e. Chronic rotating bioreactor cell culture studies (RWV) Priority 4. Acute ground based partial-G analogs. a. Parabolic flights. Very acute and short term effects of G levels between 0 and 1 in humans for fast responding systems like cardiovascular and sensorimotor as well as for acute responses in cell cultures and animals. b. Other acute models as indicated in table 3.

Barr, Yael↗

Medical Challenges of the First Canadian Long-Duration Space Mission: Lessons Learned

In 2008, Dr. Thirsk was assigned to the crew of Expedition 20/21. This Expedition represented a milestone for the Canadian Space Program since it was the first time that a Canadian would take part in a long-duration mission. Robert Thirsk had the privilege of expanding the boundaries of space exploration by living and working on board the International Space Station for six months. The launch took place on May 27, 2009 aboard a Soyuz rocket from the Cosmodrome in Baikonur, Kazakhstan. This abstract was written before Dr. Thirsk returned to Kazakhstan. Objective: To gather all medically relevant data needed to support the first Canadian long-duration mission in space, and process it to derive lessons learned for presentation and for public disclosure. Methods: Sources of data used for analysis for Expedition 20 on International Space Station included flight selection data, maintenance annual physicals, Flight Medicine Clinic visits, parabolic flight experiments, preflight exams and baseline data collections, daily in-flight exercise countermeasure and science payloads, weekly periodic fitness, nutrition, radiation and payload assessments, postflight medical exams, rehabilitation, and science activities.

Hamilton, Douglas R.↗

Gravity effects on cellulose assembly

The effect of microgravity on cellulose synthesis using the model system of Acetobacter xylinum was the subject of recent investigations using The National Aeronautics and Space Administration's Reduced Gravity Laboratory, a modified KC-135 aircraft designed to produce 20 sec of microgravity during the top of a parabolic dive. Approximately 40 parabolas were executed per mission, and a period of 2 x g was integral to the pullout phase of each parabola. Cellulose biosynthesis was initiated on agar surfaces, liquid growth medium, and buffered glucose during parabolic flight and terminated with 2.0% sodium azide or 50.0% ethanol. While careful ground and in-flight controls indicated normal, compact ribbons of microbial cellulose, data from five different flights consistently showed that during progression into the parabola regime, the cellulose ribbons became splayed. This observation suggests that some element of the parabola (the 20 sec microgravity phase, the 20 sec 2 x g phase, or a combination of both) was responsible for this effect. Presumably the cellulose I alpha crystalline polymorph normally is produced under strain, and the microgravity/hypergravity combination may relieve this stress to produce splayed ribbons. An in-flight video microscopy analysis of bacterial motions during a parabolic series demonstrated that the bacteria continue to synthesize cellulose during all phases of the parabolic series. Thus, the splaying may be a reflection of a more subtle alteration such as reduction of intermicrofibrillar hydrogen bonding. Long-term microgravity exposures during spaceflight will be necessary to fully understand the cellulose alterations from the short-term microgravity experiments.

manned↗

Utilizing Commercial Hardware and Open Source Computer Vision Software to Perform Motion Capture for Reduced Gravity Flight

Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited. Therefore, compact resistance exercise device prototypes are being developed. The NASA Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) project and the National Space Biomedical Research Institute (NSBRI) funded researchers by developing computational models of exercising with these new advanced exercise device concepts. To perform validation of these models and to support the Advanced Exercise Concepts Project, several candidate devices have been flown onboard NASAs Reduced Gravity Aircraft. In terrestrial laboratories, researchers typically have available to them motion capture systems for the measurement of subject kinematics. Onboard the parabolic flight aircraft it is not practical to utilize the traditional motion capture systems due to the large working volume they require and their relatively high replacement cost if damaged. To support measuring kinematics on board parabolic aircraft, a motion capture system is being developed utilizing open source computer vision code with commercial off the shelf (COTS) video camera hardware. While the systems accuracy is lower than lab setups, it provides a means to produce quantitative comparison motion capture kinematic data. Additionally, data such as required exercise volume for small spaces such as the Orion capsule can be determined. METHODS: OpenCV is an open source computer vision library that provides the ability to perform multi-camera 3 dimensional reconstruction. Utilizing OpenCV, via the Python programming language, a set of tools has been developed to perform motion capture in confined spaces using commercial cameras. Four Sony Video Cameras were intrinsically calibrated prior to flight. Intrinsic calibration provides a set of camera specific parameters to remove geometric distortion of the lens and sensor (specific to each individual camera). A set of high contrast markers were placed on the exercising subject (safety also necessitated that they be soft in case they become detached during parabolic flight); small yarn balls were used. Extrinsic calibration, the determination of camera location and orientation parameters, is performed using fixed landmark markers shared by the camera scenes. Additionally a wand calibration, the sweeping of the camera scenes simultaneously, was also performed. Techniques have been developed to perform intrinsic calibration, extrinsic calibration, isolation of the markers in the scene, calculation of marker 2D centroids, and 3D reconstruction from multiple cameras. These methods have been tested in the laboratory side-by-side comparison to a traditional motion capture system and also on a parabolic flight.

Biodynamics↗

Antibody binding in altered gravity: implications for immunosorbent assay during space flight

A single antibody-incubation step of an indirect, enzyme-linked immunosorbent assay (ELISA) was performed during microgravity, Martian gravity (0.38 G) and hypergravity (1.8 G) phases of parabolic flight, onboard the NASA KC-135 aircraft. Antibody-antigen binding occurred within 15 seconds; the level of binding did not differ between microgravity, Martian gravity and 1 G (Earth's gravity) conditions. During hypergravity and 1 G, antibody binding was directly proportional to the fluid volume (per microtiter well) used for incubation; this pattern was not observed during microgravity. These effects in microgravity may be due to "fluid spread" within the chamber (observed during microgravity with digital photography), leading to greater fluid-surface contact and subsequently antibody-antigen contact. In summary, these results demonstrate that: i) ELISA antibody-incubation and washing steps can be successfully performed by human operators during microgravity, Martian gravity and hypergravity; ii) there is no significant difference in antibody binding between microgravity, Martian gravity and 1 G conditions; and iii) a smaller fluid volume/well (and therefore less antibody) was required for a given level of binding during microgravity. These conclusions indicate that reduced gravity would not present a barrier to successful operation of immunosorbent assays during spaceflight.

NASA Discipline Environmental Health↗

Acute hemodynamic responses to weightlessness in humans

As NASA designs space flights requiring prolonged periods of weightlessness for a broader segment of the population, it will be important to know the acute and sustained effects of weightlessness on the cardiovascular system since this information will contribute to understanding of the clinical pharmacology of drugs administered in space. Due to operational constraints on space flights, earliest effects of weightlessness have not been documented. We examined hemodynamic responses of humans to transitions from acceleration to weightlessness during parabolic flight on NASA's KC-135 aircraft. Impedance cardiography data were collected over four sets of 8-10 parabolas, with a brief rest period between sets. Each parabola included a period of 1.8 Gz, then approximately 20 seconds of weightlessness, and finally a period of 1.6 Gz; the cycle repeated almost immediately for the remainder of the set. Subjects were semi-supine (Shuttle launch posture) for the first set, then randomly supine, sitting and standing for each subsequent set. Transition to weightlessness while standing produced decreased heart rate, increased thoracic fluid content, and increased stroke index. Surprisingly, the onset of weightlessness in the semi-supine posture produced little evidence of a headward fluid shift. Heart rate, stroke index, and cardiac index are virtually unchanged after 20 seconds of weightlessness, and thoracic fluid content is slightly decreased. Semi-supine responses run counter to Shuttle crewmember reports of noticeable fluid shift after minutes to hours in orbit. Apparently, the headward fluid shift commences in the semi-supine posture before launch. is augmented by launch acceleration, but briefly interrupted immediately in orbit, then resumes and is completed over the next hours.

short duration↗

NASA Celebrates the World Year of Physics

One of the goals of NASA's Exploration Systems Education and Outreach team is to provide educators and students authentic, relevant opportunities and activities. In celebration of the World Year of Physics 2005, there will be several NASA-sponsored events and classroom activities geared to the teaching and learning of physics. Proposed events and activities include a contest for high school classes to design a reduced gravity experiment or demonstration for flight on an aircraft executing a parabolic flight path, amusement park activities with a NASA twist, and a symposium bringing together prominent leaders in the diverse areas of physics research.

Szofran, Frank↗

Effect of microgravity and hypergravity on deposition of 0.5- to 3-micron-diameter aerosol in the human lung

We measured intrapulmonary deposition of 0. 5-, 1-, 2-, and 3-micron-diameter particles in four subjects on the ground (1 G) and during parabolic flights both in microgravity (microG) and at approximately 1.6 G. Subjects breathed aerosols at a constant flow rate (0.4 l/s) and tidal volume (0.75 liter). At 1 G and approximately 1.6 G, deposition increased with increasing particle size. In microG, differences in deposition as a function of particle size were almost abolished. Deposition was a nearly linear function of the G level for 2- and 3-micron-diameter particles, whereas for 0.5- and 1.0-micron-diameter particles, deposition increased less between microG and 1 G than between 1 G and approximately 1.6 G. Comparison with numerical predictions showed good agreement for 1-, 2-, and 3-micron-diameter particles at 1 and approximately 1.6 G, whereas the model consistently underestimated deposition in microG. The higher deposition observed in microG compared with model predictions might be explained by a larger deposition by diffusion because of a higher alveolar concentration of aerosol in microG and to the nonreversibility of the flow, causing additional mixing of the aerosols.

Flight Experiment↗

Space adaptation syndrome: multiple etiological factors and individual differences

Space motion sickness is a significant operational concern in the American and Soviet space programs. Nearly 70% of all astronauts and cosmonauts are affected to some degree during their first several days of flight. It is now beginning to appear that space motion sickness like terrestrial motion sickness is the consequence of multiple etiological factors. As we come to understand basic mechanisms of spatial orientation and sensory-motor adaptation we can begin to predict etiological factors in different motion environments. Individuals vary greatly in the extent to which they are susceptible to these different factors. However, individuals seem to be relatively self-consistent in terms of their rates of adaptation to provocative stimulation and their retention of adaptation. Attempts to relate susceptibility to motion sickness during the microgravity phases of parabolic flight maneuvers to vestibular function under 1G and 0G test conditions are described.

short duration↗

Influence of gravity on cardiac performance

Results obtained by the investigators in ground-based experiments and in two parabolic flight series of tests aboard the NASA KC-135 aircraft with a hydraulic simulator of the human systemic circulation have confirmed that a simple lack of hydrostatic pressure within an artificial ventricle causes a decrease in stroke volume of 20%-50%. A corresponding drop in stroke volume (SV) and cardiac output (CO) was observed over a range of atrial pressures (AP), representing a rightward shift of the classic CO versus AP cardiac function curve. These results are in agreement with echocardiographic experiments performed on space shuttle flights, where an average decrease in SV of 15% was measured following a three-day period of adaptation to weightlessness. The similarity of behavior of the hydraulic model to the human system suggests that the simple physical effects of the lack of hydrostatic pressure may be an important mechanism for the observed changes in cardiac performance in astronauts during the weightlessness of space flight.

NASA Discipline Cardiopulmonary↗

Eye development and the appearance and maintenance of corneal transparency

Embryonic development of the eye, including the cornea, depends on the appearance and steady maintenance of intraocular pressure. The eye is a gravity-sensitive organ, as evidence by changes in pupil diameter during parabolic flight. The cornea is largely a paracrystal of extracellular matrix. The extent to which it will polymerize normally in microgravity has yet to be determined.

NASA Discipline Developmental Biology↗

How do You Harvest Microgreens in Microgravity?

An article for the SMD tech highlights discussing the KSC IRTD Microgreens Root Zone/Shoot Zone Separator Planting Box project and corresponding parabolic flight testing. Harvesting and containment technologies for microgreens may allow astronauts to add these delicious, nutritious crops to their space diet.

Space Crop Production↗

Evaluating Microgreens Crop Readiness for Space Production.

Microgreens are small-size, nutrient-rich, and fast-grown crops, which are considered as candidates for future space exploration missions. In particular, the ISS, the Lunar Gateway, and Mars and Lunar missions could benefit from growing microgreens to supplement astronaut diets in the near future. Research at NASA’s Kennedy Space Center has focused on (1) the selection of microgreens compatible species, (2) the evaluation of microgreens food safety, (3) the use of passive wicking, on-demand watering, and hydroponics cultivation, (4) simulated microgravity growth, (5) microgreen canopy gas exchange, and (6) harvesting techniques in microgravity. This presentation summarizes this research. Microgreen species will be evaluated for their yield in relationship to the quantity of inputs – water, seeds, substrate, light intensity, photoperiod, crew time – required for their growth; for their organoleptic and sensory factors in order to down select species that are highly acceptable for humans; and for their microbial loads as detected in their growth environment and the food safety metrics of their edible tissue. Passive wicking, on-demand watering, and hydroponic systems are being studied as an efficient way to deliver essential nutrients and water to microgreens, included in a microgravity environment. Growth studies in simulated microgravity (using 3-dimensional clinostats) will assess microgreens growth relative to that in 1g. Gas exchange studies on microgreens canopies in various airflows will assess their photosynthesis and transpiration. Finally, a series of parabolic flights has enabled the evaluation of different harvesting and bagging techniques in microgravity. Indeed, traditional plant harvesting methods (scissors) in microgravity could generate significant microgreen debris in the space station cabin. Two innovative techniques, coupled to a dedicated bagging method, were designed and evaluated against the control, traditional, harvesting technique. This research was supported by grants from NASA KSC’s Independent Research and Technology Development Program, NASA’s Flight Opportunity Program, NASA Postdoctoral Program Fellowships (L.P. & C.J.) supported by NASA’s Space Biology program, and support from NASA’s Human Research Program.

crop↗

Changes in gravitational state cause changes in ocular torsion

Gravity-responsive eye torsion was studied simultaneously in both eyes during parabolic flight to determine the effects of weightlessness. Observed effects were that torsional position of eyes in the 1G states between parabolas was offset from the baseline positions obtained prior to the onset of parabolas, responses to hyper- and hypogravity were seen in most subjects, and responses were consistent within subjects but varied between subjects.

NASA Discipline Neuroscience↗

M.I.T./Canadian vestibular experiments on the Spacelab-1 mission: 4. Space motion sickness: symptoms, stimuli, and predictability

Space sickness symptoms were observed by 4 specially trained observers on Spacelab-1. Three reported persistent symptoms, and vomited repeatedly during the first and/or second day of flight. Head movements on all axes were provocative, particularly in pitch and roll. Head acceleration data recorded from 2 symptomatic crewmen showed that after several hours of physical activity in orbit, symptoms appeared, and thereafter both crewmen were compelled to limit head movements. Firm body contact with motionless surfaces helped alleviate symptoms. When crewmembers floated into unfamiliar body orientations in the cabin, inherent ambiguities in static visual orientation cues sometimes produced spatial reorientation episodes which were also provocative. Symptoms largely resembled those of other forms of prolonged motion sickness, superimposed upon other symptoms attributable to fluid shift. All 4 eventually used anti-motion sickness drugs. When they did, vomiting frequency was reduced. By the 4th day, symptoms subsided, and head accelerations again increased in magnitude and variability. Sickness intensity in orbit was not predicted by statistically concordant results of 6 acute preflight susceptibility tests. However, results from a longer duration preflight prism goggles test showed an apparent correlation. All subjects were asymptomatic making head movements in parabolic flight 4 days after the mission, but not 1 year later. Overall, results support the view that space sickness is a motion sickness.

Non-NASA Center↗