Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Performance of Photovoltaic Systems Recorded by Open Solar Performance and Reliability Clearinghouse (oSPARC)

This article analyzes data from 2,200 photovoltaic systems collected through the Open Solar Performance and Reliability Clearinghouse (oSPARC, 2018) to draw conclusions about the measured performance of the systems, how it compares to expectations, and how wide the variation is. The systems range in size from 2 kW to 1,200 kW, with an average size of 229 kW, and were activated in oSPARC between March 13, 2007 and Dec. 16, 2016. Data regarding co-incident insolation and ambient temperature are provided through the oSPARC platform for the population of systems and summarized here. Results indicate that - after correcting for measured insolation, derating for temperature, and correcting for balance-of-system efficiency and degradation as a result of system age - the performance ratio of these 2,200 systems averages 91.7%. Adjusting for known parameters such as age and efficiency, the ratio would ideally be 100%. Thus, the 'underperformance' of this system sample is measured at 9.3% and suggests that as much as 9.3% could be recovered if the systems were caused to perform as expected through optimal operation and maintenance. Efforts to correlate the performance ratio with environmental conditions resulted in very low coefficients of regression, but the method already normalizes for actual site insolation and temperature, which are responsible for much of the site-specific variation. An exemption is air-quality nonattainment areas, where the measured performance of plants averages 86.9% and is consistently lower than the average of 95.9% in areas that are in compliance with air quality standards, likely because of particulate matter such as diesel soot exacerbating the soiling rate.

14 SOLAR ENERGY↗

A Sensitivity Study of the Impact of Installation Parameters and System Configuration on the Performance of Bifacial PV Arrays

In this paper, we present the effect of installation parameters (tilt angle, height above ground, and albedo) on the bifacial gain and energy yield of three south-facing photovoltaic (PV) system configurations: a single module, a row of five modules, and five rows of five modules utilizing RADIANCE-based ray tracing model. We show that height and albedo have a direct impact on the performance of bifacial systems. However, the impact of the tilt angle is more complicated. Seasonal optimum tilt angles are dependent on parameters such as height, albedo, size of the system, weather conditions, and time of the year. For a single bifacial module installed in Albuquerque, NM, USA (35 degrees N) with a reasonable clearance (~1 m) from the ground, the seasonal optimum tilt angle is lowest (~5 degrees) for the summer solstice and highest (~65 degrees) for the winter solstice. For larger systems, seasonal optimum tilt angles are usually higher and can be up to 20 degrees greater than that for a single module system. Annual simulations also indicate that for larger fixed-tilt systems installed on a highly reflective ground (such as snow or a white roofing material with an albedo of ~81%), the optimum tilt angle is higher than the optimum angle of the smaller size systems. We also show that modules in larger scale systems generate lower energy due to horizon blocking and large shadowing area cast by the modules on the ground. For albedo of 21%, the center module in a large array generates up to 7% less energy than a single bifacial module. To validate our model, we utilize measured data from Sandia National Laboratories' fixed-tilt bifacial PV testbed and compare it with our simulations.

14 SOLAR ENERGY↗

Solar Access to Public Capital (SAPC) Working Group: Best Practices in PV System Installation; Version 1.0, March 2015; Period of Performance, October 2014 - September 2015

The following Photovoltaics Installation Best Practices Guide is one of several work products developed by the Solar Access to Public Capital (SAPC) working group, which works to open capital market investment. SAPC membership includes over 450 leading solar developers, financiers and capital managers, law firms, rating agencies, accounting and engineering firms, and other stakeholders engaged in solar asset deployment. SAPC activities are directed toward foundational elements necessary to pool project cash flows into tradable securities: standardization of power purchase and lease contracts for residential and commercial end customers; development of performance and credit data sets to facilitate investor due diligence activities; comprehension of risk perceived by rating agencies; and the development of best practice guides for PV system installation and operations and maintenance (O&M) in order to encourage high-quality system deployment and operation that may improve lifetime project performance and energy production. This PV Installation Best Practices Guide was developed through the SAPC Installation Best Practices subcommittee, a subgroup of SAPC comprised of a wide array of solar industry leaders in numerous fields of practice. The guide was developed over roughly one year and eight months of direct engagement by the subcommittee and two working group comment periods.

14 SOLAR ENERGY↗

Evaluation of PV performance models and their impact on project risk.

Photovoltaic systems are often priced in $/W{sub p}, where Wp refers to the DC power rating of the modules at Standard Test Conditions (1000 W/m{sup 2}, 25 C cell temperature) and $ refers to the installed cost of the system. However, the true value of the system is in the energy it will produce in kWhs, not the power rating. System energy production is a function of the system design and location, the mounting configuration, the power conversion system, and the module technology, as well as the solar resource. Even if all other variables are held constant, the annual energy yield (kWh/kW{sup p}) will vary among module technologies because of differences in response to low-light levels and temperature. Understanding energy yield is a key part of understanding system value. System performance models are used during project development to estimate the expected output of PV systems for a given design and location. Performance modeling is normally done by the system designer/system integrator. Often, an independent engineer will also model system output during a due diligence review of a project. A variety of system performance models are available. The most commonly used modeling tool for project development and due diligence in the United States is probably PVsyst, while those seeking a quick answer to expected energy production may use PVWatts. In this paper, we examine the variation in predicted energy output among modeling tools and users and compare that to measured output.

14 SOLAR ENERGY↗

Summary of photovoltaic system performance models

A detailed overview of photovoltaics (PV) performance modeling capabilities developed for analyzing PV system and component design and policy issues is provided. A set of 10 performance models are selected which span a representative range of capabilities from generalized first order calculations to highly specialized electrical network simulations. A set of performance modeling topics and characteristics is defined and used to examine some of the major issues associated with photovoltaic performance modeling. Each of the models is described in the context of these topics and characteristics to assess its purpose, approach, and level of detail. The issues are discussed in terms of the range of model capabilities available and summarized in tabular form for quick reference. The models are grouped into categories to illustrate their purposes and perspectives.

Smith, J. H.↗

Open data sets for assessing photovoltaic system reliability

Photovoltaic (PV) systems have become a cornerstone of renewable energy strategies, particularly due to the significant reduction in solar power costs over the past decade. However, the long-term reliability of PV installations presents a persistent challenge, requiring the development of advanced monitoring and predictive maintenance strategies. A wide range of data types is used to evaluate the health of PV systems, including environmental conditions, electrical performance, and inspection imagery. These data enable methodologies such as machine learning (ML) models for lifetime prediction and computer vision techniques for defect detection. However, the acquisition of high-quality and comprehensive data is difficult, particularly in terms of long-term consistency and data variety. Publicly available data sets serve as valuable resources for addressing these challenges, but they often suffer from fragmentation and are difficult to access. This paper presents a comprehensive review of existing open-source data sets related to PV degradation, analyzing their features, functionalities, and potential applications. We categorize these data sets based on the specific aspects of PV system information they cover, such as environmental conditions, operational monitoring, image inspection and module materials, and propose relevant tools and ML models for processing them. In addition, we propose practices for future data collection and usage, while also discussing potential directions in data-driven research. Our aim is to enhance data utilization and publication among researchers and industry professionals, promoting a deeper understanding of the role of data in enhancing the performance and durability of PV systems.

14 SOLAR ENERGY↗

Life-Cycle Cost and Optimization of PV Systems Based on Power Duration Curve with Variable Performance Ratio and Availability

A new derivation of Power Duration Curve is presented and applied to analysis of photovoltaic system life cycle cost. The effect of non-unity Performance Ratio and non-unity Availability on the power duration curve are illustrated. The effect of these two key performance indicators on calculation of life cycle cost and PV system design optimization (optimal DC/AC ratio) are illustrated as example applications of the method.

14 SOLAR ENERGY↗

Updates to the Instant Online PV LCOE Calculator Tool

Levelized cost of energy (LCOE) is an important metric for techno-economic analysis of PV modules, systems, and performance. An NREL team within DuraMAT has developed a simplified PV-specific LCOE calculator as an alternative to the NREL System Advisor Model (SAM) for applications that do not have the degree of detail required by SAM. This webinar will review recent data and new features that have been added to the simplified calculator this year, including breakeven buttons, commercial system options, and inverter loading ratios. It will also review the structure of the source code on GitHub, how to edit a local version of the calculator, and walk through some example use cases for the calculator.

calculator↗

PV System 'Availability' as a Reliability Metric -- Improving Standards, Contract Language and Performance Models

The use of the term 'availability' to describe a photovoltaic (PV) system and power plant has been fraught with confusion for many years. A term that is meant to describe equipment operational status is often omitted, misapplied or inaccurately combined with PV performance metrics due to attempts to measure performance and reliability through the lens of traditional power plant language. This paper discusses three areas where current research in standards, contract language and performance modeling is improving the way availability is used with regards to photovoltaic systems and power plants.

14 SOLAR ENERGY↗

The Holy Grail of Resource Assessment: Low Cost Ground-Based Measurements with Good Accuracy

Using performance data from some of the millions of installed photovoltaic (PV) modules with micro-inverters may afford the opportunity to provide ground-based solar resource data critical for developing PV projects. The method used back-solves for the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the micro-inverter ac production data. When the derived values of DNI and DHI were then used to model the performance of other PV systems, the annual mean bias deviations were within +/- 4%, and only 1% greater than when the PV performance was modeled using high quality irradiance measurements. An uncertainty analysis shows the method better suited for modeling PV performance than using satellite-based global horizontal irradiance.

14 SOLAR ENERGY↗