Exploiting the PRISM Feature and Purity Monitors of the SBND Neutrino Detector
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Several DUNE ND off axis locations were simulated using GENIE and ACHILLES, and generator differences and FSI contributions were examined for various observables. Predictions were compared with those of existing experiments, and it is shown that the DUNE ND 20m off axis predictions are similar to that of MicroBooNE for various observables. Finally, the 2p2h interaction mode was simulated for ACHILLES for the first time for ICARUS, and a preliminary comparison is made to MicroBooNE data and simulations from different event generators.
NuSTEC CEWG Meeting (June 2021)
N/A
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided
A method, apparatus, and system for improved VA-TIRFM microscopy. The method comprises automatically controlled calibration of one or more laser sources by precise control of presentation of each laser relative a sample for small incremental changes of incident angle over a range of critical TIR angles. The calibration then allows precise scanning of the sample for any of those calibrated angles for higher and more accurate resolution, and better reconstruction of the scans for super resolution reconstruction of the sample. Optionally the system can be controlled for incident angles of the excitation laser at sub-critical angles for pseudo TIRFM. Optionally both above-critical angle and sub critical angle measurements can be accomplished with the same system.
Abstract not provided.
The DUNE near detector LAr-TPC can be moved to different off-axis positions to sample different neutrino fluxes, which in turn will yield different cross section distributions for observables. Several DUNE ND off axis locations were simulated using GENIE and ACHILLES, and generator differences and FSI contributions were examined for various observables. Additionally, the predictions were compared with those of existing experiments, and it is shown that the DUNE ND 20m off axis predictions are similar to that of MicroBooNE for various observables. Finally, the 2p2h interaction mode was simulated for ACHILLES for the first time for ICARUS, and a preliminary comparison is made to MicroBooNE data and simulations from different event generators.
We recently reported an antibody-free targeted protein quantification strategy, termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM) for achieving significantly enhanced sensitivity using selected reaction monitoring (SRM) mass spectrometry. Integrating PRISM with front-end IgY14 immunoaffinity depletion, sensitive detection of targeted proteins at 50-100 pg/mL levels in human blood plasma/serum was demonstrated. However, immunoaffinity depletion is often associated with undesired losses of target proteins of interest. Herein we report further evaluation of PRISM-SRM quantification of low-abundance serum proteins without immunoaffinity depletion and the multiplexing potential of this technique. Limits of quantification (LOQs) at low ng/mL levels with a median CV of ~12% were achieved for proteins spiked into human female serum using as little as 2 µL serum. PRISM-SRM provided up to ~1000-fold improvement in the LOQ when compared to conventional SRM measurements. Multiplexing capability of PRISM-SRM was also evaluated by two sets of serum samples with 6 and 21 target peptides spiked at the low attomole/µL levels. The results from SRM measurements for pooled or post-concatenated samples were comparable to those obtained from individual peptide fractions in terms of signal-to-noise ratios and SRM peak area ratios of light to heavy peptides. PRISM-SRM was applied to measure several ng/mL-level endogenous plasma proteins, including prostate-specific antigen, in clinical patient sera where correlation coefficients > 0.99 were observed between the results from PRISM-SRM and ELISA assays. Our results demonstrate that PRISM-SRM can be successfully used for quantification of low-abundance endogenous proteins in highly complex samples. Moderate throughput (50 samples/week) can be achieved by applying the post-concatenation or fraction multiplexing strategies. We anticipate broad applications for targeted PRISM-SRM quantification of low-abundance cellular proteins in systems biology studies as well as candidate biomarkers in biofluids.
Mollusk shells protect the animals that form and inhabit them. They are composites of minerals and organics, with diverse mesostructures, including nacre, prismatic calcite, crossed-lamellar aragonite, and foliated calcite. Twins, that is, crystals mirror symmetric with respect to their coherent interface, occurring as formation or deformation twins, are observed in all mollusk shell mesostructures but never within calcite prisms. Here, nanotwins and microwins within single calcite prisms are observed in different shells. Using Polarization-dependent Imaging Contrast (PIC) mapping with 20–60 nm resolution, twins are observed to be 0.2–3 µm thick layers of differently oriented and colored crystals with respect to the main prism crystal. Multiple twins are interspersed with the prism crystal, parallel to one another, and similarly oriented. When comparing images of calcite prisms and twins obtained by PIC mapping and by Electron Back-Scattered Diffraction (EBSD), the images correspond precisely. All twins are e-twin types, with 127° angular distance between c-axes. E-twins are the most common deformation twins in geologic calcite, as also observed here in Carrara marble. Location of all twins near the outer surface of all shells and e-twin type both suggest that twins within calcite prisms in mollusk shells result from deformation twinning.
Mass spectrometry-based targeted quantification is a promising technology for site-specific quantification of posttranslational modifications (PTMs). However, a major constraint of most targeted MS approaches is the limited sensitivity for quantifying low-abundance PTMs, requiring the use of affinity reagents to enrich specific PTMs. Herein, we demonstrate the direct site-specific quantification of ERK phosphorylation isoforms (pT, pY, pTpY) and their relative stoichiometries using a highly sensitive targeted MS approach termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM). PRISM provides effective enrichment of target peptides within a given fraction from complex biological matrix with minimal sample losses, followed by selected reaction monitoring (SRM) quantification. The PRISM-SRM approach enabled direct quantification of ERK phosphorylation in human mammary epithelial cells (HMEC) from as little as 25 µg tryptic peptides from whole cell lysates. Compared to immobilized metal-ion affinity chromatography, PRISM provided >10-fold improvement in signal intensities, presumably due to the better peptide recovery of PRISM for handling small size samples. This approach was applied to quantify ERK phosphorylation dynamics in HMEC treated by different doses of EGF at both the peak activation (10 min) and steady state (2 h). At 10 min, the maximal ERK activation was observed with 0.3 ng/mL dose, whereas the maximal steady state level of ERK activation at 2 h was at 3 ng/ml dose, corresponding to 1200 and 9000 occupied receptors, respectively. At 10 min, the maximally activated pTpY isoform represented ~40% of total ERK, falling to less than 10% at 2 h. The time course and dose-response profiles of individual phosphorylated ERK isoforms indicated that singly phosphorylated pT-ERK never increases significantly, while the increase of pY-ERK paralleled that of pTpY-ERK. This data supports for a processive, rather than distributed, model of ERK phosphorylation. The PRISM-SRM quantification of protein phosphorylation illustrates the potential for simultaneous quantification of multiple PTMs.
A gated spectrometer has been designed for real-time, pulsed infrared (IR) studies at the National Synchrotron Light Source at the Brookhaven National Laboratory. A pair of 90-degree, off-axis parabolic mirrors are used to relay the light from an entrance slit to an output recording camera. With an initial wavelength range of 1500–4500 nm required, gratings could not be used in the spectrometer because grating orders would overlap. A magnesium oxide prism, placed between these parabolic mirrors, serves as the dispersion element. The spectrometer is doubly telecentric. With proper choice of the air spacing between the prism and the second parabolic mirror, any spectral region of interest within the InSb camera array’s sensitivity region can be recorded. The wavelengths leaving the second parabolic mirror are collimated, thereby relaxing the camera positioning tolerance. To set up the instrument, two different wavelength (visible) lasers are introduced at the entrance slit and made collinear with the optical axis via flip mirrors. After dispersion by the prism, these two laser beams are directed to tick marks located on the outside housing of the gated IR camera. This provides first-order wavelength calibration for the instrument. Light that is reflected off the front prism face is coupled into a high-speed detector to verify steady radiance during the gated spectral imaging. Alignment features include tick marks on the prism and parabolic mirrors. This instrument was designed to complement single-point pyrometry, which provides continuous time histories of a small collection of spots from shock-heated targets.
Ultra-high temperature transition-metal ceramics are potential candidates for fusion reactor structural and plasma-facing components. We reveal the irradiation damage microstructural phenomena in Boron-11 enriched titanium diboride (TiB 2 ) using mixed-spectrum neutron irradiations, combined with state-of-art characterization using transmission electron microscopy (TEM) and high resolution TEM. Irradiations were performed using High Flux Isotope Reactor at ~220 and 620 °C up to 2.4 x 10 25 n.m -2 (E > 0.1 MeV). The calculated dose including contribution from residual Boron-10 ( 10 B) transmutation recoils, was ~4.2 displacements per atom. TiB 2 is susceptible to irradiation damage in terms of dislocation loop formation, cavities and anisotropic swelling induced micro-cracking. At both 220 and 620 °C, TEM revealed dislocation loops on basal and prism planes, with nearly two orders of magnitude higher number density of prism-plane loops. HRTEM, electron diffraction and relrod imaging revealed additional defects on {10$ \overline{1}\ $0} planes, identified as faulted prism-plane dislocation loops. High defect cluster density on prism planes will induce a-lattice parameter swelling of TiB 2 , as reported in literature. This anisotropic lattice parameter swelling induced grain boundary micro-cracking, the extent of which decreased with increasing irradiation temperature. The dominance of irradiation defect clusters on prism planes is different than typical hexagonal ceramics where dislocation loops predominantly form on basal planes, causing c-lattice parameter swelling. Helium generation and temperature rise from the transmutation of residual 10 B resulted in matrix and grain boundary cavities for the irradiation at 620 °C. In conclusion, the study additionally signifies isotopic enrichment as a viable approach to produce transition-metal diborides for potential nuclear structural applications.
Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6}, isostructural to Ca{sub 3}Co{sub 2}O{sub 6}, is revealed by the study of the phase relations in the system SrO-InO{sub 1.5}-CoO{sub x} (1000 {sup o}C). The structure of Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} is refined by the combination of powder X-ray and neutron diffraction. Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} crystallizes in a trigonal lattice with the cell parameters a=b=9.59438(3) A, c=11.02172(4) A with the space group R-3c. Its structure possesses 1D (In/Co)O{sub 3} chains running along the c-axis constructed by alternating face-sharing CoO{sub 6} octahedra and (In{sub 0.9}Co{sub 0.1})O{sub 6} trigonal prisms. The co-occupation of In{sup 3+} and Co{sup 3+} at the trigonal prismatic site is evidenced by elementary analysis and determined by the structure refinement. Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} is paramagnetic, and the susceptibility is consistent with the occupation of Co{sup 3+} at 10% of the trigonal prismatic positions in a high spin state (HS, S=2). The HS Co{sup 3+} is well separated by diamagnetic CoO{sub 6} octahedra and InO{sub 6} trigonal prisms and shows a g factor of 2.0 in the magnetic measurements. -- Graphical abstract: Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} possesses 1D chains constructed by alternating face-sharing CoO{sub 6} octahedra and (In{sub 0.9}Co{sub 0.1})O{sub 6} trigonal prisms. The high spin Co{sup 3+} (S=2) in trigonal prism shows a g factor of 2.0. Display Omitted Research highlights: {yields} Phase diagram of SrO-InO{sub 1.5-}CoO{sub x} at 1000 {sup o}C in air atmosphere is presented. {yields} A new compound Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} that is isostructural to Ca{sub 3}Co{sub 2}O{sub 6} is revealed. {yields} 1D chain is formed by alternating face-sharing CoO{sub 6} octahedra and (In{sub 0.9}Co{sub 0.1})O{sub 6} trigonal prisms.{yields} Co{sup 3+} at trigonal prismatic site is in high spin state (S=2) with a g factor of 2.0.
Scanning transmission electron microscopy (STEM) is an extremely versatile method for studying materials on the atomic scale. Many STEM experiments are supported or validated with electron scattering simulations. However, using the conventional multislice algorithm to perform these simulations can require extremely large calculation times, particularly for experiments with millions of probe positions as each probe position must be simulated independently. Recently, the plane-wave reciprocal-space interpolated scattering matrix (PRISM) algorithm was developed to reduce calculation times for large STEM simulations. Here, we introduce a new method for STEM simulation: partitioning of the STEM probe into “beamlets,” given by a natural neighbor interpolation of the parent beams. This idea is compatible with PRISM simulations and can lead to even larger improvements in simulation time, as well requiring significantly less computer random access memory (RAM). We have performed various simulations to demonstrate the advantages and disadvantages of partitioned PRISM STEM simulations. We find that this new algorithm is particularly useful for 4D-STEM simulations of large fields of view. We also provide a reference implementation of the multislice, PRISM, and partitioned PRISM algorithms.