Cold cathode ionization gage has rigid metal housing

Cold cathode ionization gage in a stainless steel housing accurately measures high pressures. The penning effect is used with a high voltage discharge in the presence of a magnetic field for an ion current proportional to the gas pressure in the gage.

Herzog, R.↗

Debris prevention analysis for DFI/OFI/OEI (STS-26 configuration only)

The first 3 shuttle flights to use the Redesigned Solid Rocket Motors (RSRMs) will utilize Development Flight Instrumentation (DFI), as well as Operational Flight Instrumentation (OFI), and Operational Environment Instrumentation (OEI). The OFI consists of high pressure transducers used on both RSRMs to monitor the igniter and motor chamber pressure. DFI consists of assorted strain gages, temperature sensors, accelerometers, girth gages, and low level pressure transducers. The latter are installed on the left hand booster to measure post-separation aerodynamic loading. OEI consistes of temperature sensors. After Flight 3, all DFI gages are to be deleted, and only OFI and OEI will be used for subsequent flights. This report deals specifically with debris prevention and hazards concernig the STS-26 flight DFI configuration only. Continued analysis is being done that will adequately address the debris hazards associated with the STS-27 and subsequent flight DFI configurations.

Richi, Glen A.↗

Bileaf mechanical strain gage

Bileaf lever detects small deformations by highly magnifying linear displacements. Device is applicable to force measuring instruments, pressure cells, temperature gages, existing strain gages, dial gages, or extensometers. Additional magnification is obtained by cementing a small mirror to mobile end of bileaf.

Guist, L. R.↗

Measurement component technology. Volume 1: Cryogenic pressure measurement technology, high pressure flange seals, hydrogen embrittlement of pressure transducer material, close coupled versus remote transducer installation and temperature compensation of pressure transducers

The results are presented of an investigation into the availability and performance capability of measurement components in the area of cryogenic temperature, pressure, flow and liquid detection components and high temperature strain gages. In addition, technical subjects allied to the components were researched and discussed. These selected areas of investigation were: (1) high pressure flange seals, (2) hydrogen embrittlement of pressure transducer diaphragms, (3) The effects of close-coupled versus remote transducer installation on pressure measurement, (4) temperature transducer configuration effects on measurements, and (5) techniques in temperature compensation of strain gage pressure transducers. The purpose of the program was to investigate the latest design and application techniques in measurement component technology and to document this information along with recommendations for upgrading measurement component designs for future S-2 derivative applications. Recommendations are provided for upgrading existing state-of-the-art in component design, where required, to satisfy performance requirements of S-2 derivative vehicles.

Hayakawa, K. K.↗

Modifications to the nozzle test chamber to extend nozzle static-test capability

The nozzle test chamber was modified to provide a high-pressure-ratio nozzle static-test capability. Experiments were conducted to determine the range of the ratio of nozzle total pressure to chamber pressure and to make direct nozzle thrust measurements using a three-component strain-gage force balance. Pressure ratios from 3 to 285 were measured with several axisymmetric nozzles at a nozzle total pressure of 15 to 190 psia. Devices for measuring system mass flow were calibrated using standard axisymmetric convergent choked nozzles. System mass-flow rates up to 10 lbm/sec are measured. The measured thrust results of these nozzles are in good agreement with one-dimensional theoretical predictions for convergent nozzles.

Keyes, J. W.↗

Quick actuating closure and handling system

A quick activating closure and handling system, which utilizes conical sections for locking, was developed to allow quick access to the combustor internal components of the 8 ft High Temperature Tunnel. These critical components include the existing methane spraybar, a transpiration cooled nozzle and the new liquid oxygen (LOX) injection system housed within the combustor. A substantial cost savings will be realized once the mechanism is installed since it will substantially reduce the access time and increase the time available for conducting wind tunnel tests. A need exists for more frequent inspections when the wind tunnel operates at the more severe conditions generated by using LOX in the combustor. A loads analysis and a structural (finite element) analysis were conducted to verify that the new closure system is compatible with the existing pressure shell. In addition, strain gages were placed on the pressure vessel to verify how the pressure shell reacts to transient pressure loads. A scale model of the new closure system was built to verify the operation of the conical sections in the locking mechanisms.

Allred, Johnny W.↗

Observed acoustic and aeroelastic spectral responses of a MOD-2 turbine blade to turbulence excitation

Early results from a recent experiment designed to directly evaluate the aeroacoustic/elastic spectral responses of a MOD-2 turbine blade to turbulence-induced unsteady blade loads are discussed. The experimental procedure consisted of flying a hot-film anemometer from a tethered balloon in the turbine inflow and simultaneously measuring the fluctuating airload and aeroelastic response at two blade span stations (65% and 87% spans) using surface-mounted, subminiature pressure transducers and standard strain gage instrumentation. The radiated acoustic pressure field was measured with a triad of very-low-frequency microphones placed at ground level, 1.5 rotor diameters upwind of the disk. Initial transfer function estimates for acoustic radiation, blade normal forces, flapwise acceleration/displacement, and chord/flapwise moments are presented.

Kelley, N. D.↗

Apparatus for pre-stress-straining rod-type specimens in tension for in-situ passive fracture testing

A stress-strain testing apparatus imposes a stress-strain on a specimen while disposed in a controlled environment. Each end of the specimen is fastened to an end cap and a strain gage is attached to the specimen. An adjusting mechanism and a compression element are disposed between the end caps forming a frame for applying forces to the end caps and thereby stress-straining the specimen. The adjusting mechanism may be extended or retracted to increase or decrease the imposed stress-strain on the specimen, and the stress-strain is measured by the strain gage on the specimen while the apparatus is exposed to an environment such as high pressure hydrogen. Strain gages may be placed on the frame to measure stress-strains in the frame that may be caused by the environment.

42 ENGINEERING↗

Three-in-one gage

The Three-in-One Gage is a three way gage designed to measure pressure, temperature, and displacement at the same port continuously. The Two-in-One Gage is a two way gage designed to measure pressure and temperature in the same port continuously. The Two-in-One is an adaptation of the Three-in-One to incorporate dual seals, however, without the proximity sensor. The Three-in-One is assembled using two Type K thermocouples, 1 Kulite Pressure Transducer, and one Kaman Proximity Displacement Sensor. Tests of performance were completed.

Garecht, D. M.↗

Vacuum gage system for radiation environment

Hot-cathode ionization gages used to measure high-vacuum pressures are subject to error when ionizing radiation is present. Because this radiation creates additional ions, a second ion gage is mounted near the pressure-measuring gage to detect and measure the radiation induced error.

Summers, R. L.↗

Results of tests CS4 and CS5 to investigate dynamic loads and pressures on 0.03-scale models (Ax1319-3/4 and 45-0) of mated 747 cam and space shuttle orbiter in the Boeing transonic wind tunnel

A 0.03-scale model of the 747 CAM/Orbiter was tested in an 8 x 12 foot transonic wind tunnel. Dynamic loads, pressure, and empennage flow field data were obtained using pressure transducers, strain gages, and a split film anemometer. The test variables included Mach number, angle of attack, sideslip angle, orbiter tailcone on and off, orbiter partial tailcone, orbiter nozzle air scoops, orbiter body flap angle, and orbiter elevon angle.

Source record↗

Pull Test Verifies Gap Loading

Thin plastic strip pulled away from gap by force gage to measure pressure applied on gap filler. Force necessary to initiate movement of thin plastic strip is measure of gap tightness. Procedure determines interface pressures or loads where conventional load-measuring equipment cannot be used. Used to check refrigerator-door seals.

Hagen, G. R.↗

Explosive east coast cyclogenesis - Numerical experimentation and model-based diagnostics

Numerical experimentation of explosive east-coast cyclogenesis is performed using the Florida State University Global Spectral Model (FSUGSM). The three cases examined here are the Presidents' Day storm of February 18-19, 1979 and the North Atlantic and Pacific bombs of January 18-20, 1979 which formed off the east coasts of the United States and Japan, respectively. The use of a global model provides a framework for studying the phenomena on the 3-5 day time scale. The forecast verifications of the numerical experiments indicate that the FSUGSM was able to adequately predict the phase, intensity, and synoptic-scale structure. These results justify the use of model data for diagnostic studies of the bomb. The model data are used to quantify the role of the adiabatic and diabatic forcing in the explosive cyclogenetic process, using surface pressure tendency to gage development.

Manobianco, John↗

Typical testing experience in cryogenic wind tunnels

Airfoil testing as a major activity of many wind tunnels is considered, and emphasis is placed on airfoil testing with sidewall boundary-layer removal, oscillating airfoil testing, and three-dimensional wake topology. Buffeting as the structural response of an aircraft or test model to the aerodynamic excitation produced by separated flows is analyzed, as well as flutter problems and testing techniques. Strain-gage balance studies, optical methods and visualization techniques, and fluid mechanics are examined. Focus is placed on a two-spot laser as a boundary-layer probe, hot-film gages, fluctuating-pressure measurements, skin-friction balance, and nonadiabatic airfoil testing. Boattail afterbody pressure tests are covered, and Space Shuttle Orbiter base drag and launch configuration are discussed.

Kilgore, Robert A.↗

CFD Simulations of the IHF 13-Inch Nozzle Flow: 55-deg Sphere-Cone Model, Manufactured Fences and Gaps

This paper reports computational analyses of testsin a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using 55-deg sphere-cone models placed in a free jet downstream of the 13-inch diameter conical nozzle in the Ames 60-MW Interaction Heating Facility. Some of the sphere-cone models include surface features such as manufactured fences and gaps intended to simulate effects of differential recession, all of which disturb the flow, producing augmented heating locally and downstream.Test calibration data were obtained using slug and Gardon gage stagnation calorimeters, and a sphere-cone calorimeter model with six Gardon gages and five pressure tabs.The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. These simulations take into account nonuniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields.

Arc-jets↗