Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PMUs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Power System Event Identification Based on Deep Neural Network With Information Loading

Online power system event identification and classification are crucial to enhancing the reliability of transmission systems. In this study, we develop a deep neural network (DNN) based approach to identify and classify power system events by leveraging real-world measurements from hundreds of phasor measurement units (PMUs) and labels from thousands of events. Two innovative designs are embedded into the baseline model built on convolutional neural networks (CNNs) to improve the event classification accuracy. First, we propose a graph signal processing based PMU sorting algorithm to improve the learning efficiency of CNNs. Second, we deploy information loading based regularization to strike the right balance between memorization and generalization for the DNN. Numerical results based on real-world dataset from the Eastern Interconnection of the U.S power transmission grid show that the combination of PMU based sorting and the information loading based regularization techniques help the proposed DNN approach achieve highly accurate event identification and classification results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning-Based Real-Time Event Identification Using Rich Real PMU Data

A large-scale deployment of phasor measurement units (PMUs) that reveal the inherent physical laws of power systems from a data perspective enables an enhanced awareness of power system operation. However, the high-granularity and non-stationary nature of PMU data and imperfect data quality could bring great technical challenges for real-time system event identification. To address these challenges, this paper proposes a two-stage learning-based framework. In the first stage, a Markov transition field (MTF) algorithm is exploited to extract the latent data features by encoding temporal dependency and transition statistics of PMU data in graphs. Then, a spatial pyramid pooling (SPP)-aided convolutional neural network (CNN) is established to efficiently and accurately identify power events. The proposed method fully builds on and is also tested on a large real-world dataset from several tens of PMU sources (and the corresponding event logs), located across the U.S., with a time span of two consecutive years. We report the numerical results validate that our method has high identification accuracy while showing good robustness against poor data quality.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online PMU Missing Value Replacement Via Event-Participation Decomposition

We introduce a new method for online Phasor Measurement Unit (PMU) missing value replacement. Our approach allows us to decompose PMU event responses into a non-dynamic component (denoted the participation factor) that can be inferred directly from the past and a dynamic component that can be inferred directly from all other PMUs (denoted the event strength). When missing values occur, we can use these two components, which do not rely on the missing index, to estimate the correct value. The method is extremely fast and can easily be used for online applications. Furthermore, extensive testing on real power system event data reveals that our approach achieves state-of-the-art performance in terms of Mean Absolute Percent Errors (MAPEs) for PMU data dropped during event periods. Here, the method also yields an interpretable and simplified view of events for further analysis and applications. The method relies only on PMU data and does not take outside information such as network topology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structure-Informed Graph Learning of Networked Dependencies for Online Prediction of Power System Transient Dynamics

Online transient analysis plays an increasingly important role in dynamic power grids as the renewable generation continues growing. Traditional numerical methods for transient analysis not only are computationally intensive but also require precise contingency information as input, and therefore, are not suitable for online applications. Existing online transient assessment studies focus on the determination of post-contingency system stability or stability margin. Here, this paper develops a novel graph-learning framework, Deep-learning Neural Representation or DNR, for online prediction, of the time-series trajectories of the system states using initial system responses that can be measured by phasor measurement units (PMUs). The proposed DNR framework consists of two sequential modules: a Network Constructor that captures network dependencies among generators, and a Dynamics Predictor that predicts the system trajectories. The key to improved prediction performance is the introduction of the spatio-temporal message-passing operations into graph neural networks with structural knowledge. Its effectiveness and scalability are validated through comparative studies, demonstrating the prediction performance under different contingency scenarios for systems of different sizes. This framework provides a solution to online predicting post-fault system dynamics based on real-time PMU measurements. Additionally, it can also be applied to facilitate the offline transient simulation without simulating the entire trajectories.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bayesian High-Rank Hankel Matrix Completion for Nonlinear Synchrophasor Data Recovery

Phasor measurement units (PMUs) provide high temporal-resolution synchrophasor measurements for power system monitoring and control. The frequent data quality issues, such as missing and bad data, prevent the incorporation of synchrophasor data in real-time operations. Most existing data-driven data recovery methods assume the power system dynamics can be approximated by a linear dynamical system, and the recovery performance degrades significantly when the power system is experiencing nonlinear dynamics during significant events. Here, this paper proposes a data-driven Bayesian nonlinear synchrophasor data recovery method (Ba-NSDR) that can recover a consecutive time period of simultaneous data losses or errors across all channels, even when the underlying system is highly nonlinear. The idea is to lift the Hankel matrix of the spatial-temporal synchrophasor data to a higher dimension such that the lifted Hankel matrix is low-rank in that space and can be processed with the kernel trick. Our proposed Bayesian method then infers the probabilistic distributions of synchrophasor from the partial observations. Some distinctive features of Ba-NSDR include an uncertainty index to measure the accuracy of the recovery result and the robustness to parameter selections. Our method is verified on both synthetic and recorded event datasets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self-Healing Attack-Resilient PMU Network for Power System Operation

In this paper, we propose a self-healing phasor measurement unit (PMU) network that exploits the features of dynamic and programmable configuration in a software-defined networking infrastructure to achieve resiliency against cyber-attacks. After a cyber-attack, the configuration of network switches is changed to isolate the compromised PMUs/phasor data concentrators to prevent further propagation of the attack; meanwhile, the disconnected yet uncompromised PMUs will be reconnected to the network to "self-heal" and thus restore the observability of the power system. Specifically, we formulate an integer linear programming model to minimize the overhead of the self-healing process (e.g., the recovery latency), while considering the constraints of power system observability, hardware resources, and network topology. We also propose a heuristic algorithm to decrease the computational complexity. Case studies of a PMU network based on the IEEE 30-bus and 118-bus systems are used to validate the effectiveness of the self-healing mechanism.

Cybersecurity↗

Learning Behavior of Distribution System Discrete Control Devices for Cyber-Physical Security

Conventional cyber-security intrusion detection systems monitor network traffic for malicious activity and indications that an adversary has gained access to the system. The approach discussed here expands the idea of a traditional intrusion detection system within electrical power systems, specifically power distribution networks, by monitoring the physical behavior of the grid. This is achieved through the use of high-rate distribution Phasor Measurement Units (PMUs), alongside SCADA packets analysis, for the purpose of monitoring the behavior of discrete control devices. In this work we present a set of algorithms for passively learning the control logic of voltage regulators and switched capacitor banks. Upon detection of an abnormal operation, the operator is alerted and further action can be taken. Finally, the proposed learning algorithms are validated on both simulated data and on measured PMU data from a utility pilot deployment site.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Anomaly Detection, Localization and Classification using Drifting Synchrophasor Data Streams

With ongoing automation and digitization of the electric power system, several Phasor Measurement Units(PMUs) have been deployed for monitoring and control. PMU data can have multiple anomalies, and many of the researchers in the past have concentrated on training machine/deep learning algorithms offline for anomaly detection over PMU data (i.e., not in real time). These machine/deep learning algorithms, when trained offline on a sample rather than a population of the dataset, fail to consider the dynamic behavior of the power grid in real-time, resulting in low accuracy. Considering the dynamic behavior of the power grid (e.g., change in load, generation, distributed energy resources (DERs) switching, network, controls), the definition of data anomalies varies in time and requires online training. A fundamental challenge is to enable online (i.e., real-time) training of machine/deep learning algorithms for anomaly detection over streaming PMU data. While machine/deep learning is often desirable to manage data streams, training a deep learning algorithm over streaming PMU data is nontrivial due to changes in data statistics caused by dynamic streaming data. This paper proposes PMUNET: a novel device-level deep learning-based data-driven approach for anomaly detection, localization, and classification over streaming PMU data, using online learning and multivariate data-drift detection algorithm .Two variants of PMUNET, Dynamic data Change Driven Learning (DCDL) and Continuity Driven Learning (CDL), are proposed and compared. DCDL aims to train the deep learning algorithm whenever the definition of anomaly changes due to the power grid dynamics. On the other hand, CDL continuously trains the deep learning algorithm over the PMU data-stream. The experimental results verify that DCDL outperforms CDL and other efficient anomaly detection methods over multiple events such as faults and load/ generator/capacitor/DERs variations/switching for IEEE 14 and 39 Bus test system as well as real PMU industrial data. The result verifies that DCDL variant of PMUNET improves over existing approach with a gain of 2% - 10% in terms of accuracy, false-positive rate, and false-negative rate.

adversarial deep learning↗

Pulsar-Calibrated Timing Source for Synchronized Sampling

The Global Positioning System (GPS) is critical to the real-time synchronized sampling of phasor measurement units (PMUs). Unfortunately, GPS signals are occasionally unstable due to several factors such as weak satellite signal and GPS spoofing, thereby leaving the PMU with a degraded sampling performance. In this letter, a novel Pulsar-calibrated Timing Source (PTS) is proposed as the alternative timing source for synchronized sampling. Further, the PTS can generate the timing signal with a 1 μs drift error within 91 holdover minutes to ensure continuity of sampling accuracy. Experimental tests are conducted and the results reveal the reliability and accuracy of the PTS for PMU synchronization.

42 ENGINEERING↗

Multi-Source Data Aggregation and Real-Time Anomaly Classification and Localization in Power Distribution Systems

This paper proposes a real-time anomaly location and classification framework for power distribution systems to simultaneously determine the type of anomaly (i.e., short-circuit fault, cyber attack, DER switching) and its location. The proposed framework employs the data aggregation module to collect the measurement data from multiple field devices operating at different sampling rates, such as protection relays and D-PMUs. The output of the data aggregation is then fed into a multi-task learning-based long-based short-term memory (MTL-LSTM) to classify the type of anomaly and the location in two separate tasks. The proposed MTL-LSTM approach can be utilized in real-time operation in order to distinguish between normal and several anomalous operations and locate the anomaly. The proposed framework is tested on a modified IEEE 33-bus test feeder benchmark that integrates solar generation and energy storage. Furthermore, the results show that the proposed framework can locate and classify anomalies for several operation conditions with more than 96% accuracy. Further experiments highlight the impact of aggregating multiple sources of data on the performance of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchrophasor Measurements-based Events Detection Using Deep Learning

Deep learning algorithms have been developed for phasor measurement units (PMUs) analysis aiming at providing grid operators to observe and react to significant real-time changes in the grid associated with multiple factors (e.g., power generation and load variations, different type of faults, and equipment mailfunction), or for offline post-event system diagnostics. In this study, a Long Short-Term Memory (LSTM)-based deep neural network (DNN) is adopted and evaluated to identify the most appropriate model configurations for event detection and longer-term anomalous pattern extraction. The proposed DNN model shows the potential on long-term predictions with the ability to capture nonlinear and nonstationary mixture complex patterns in PMU datasets. Real-world PMU in the WECC system were used for model development and validation.

deep learning↗

Synchronized Phasor Data for Analyzing Wind Power Plant Dynamic Behavior and Model Validation

The U.S. power industry is undertaking several initiatives that will improve the operations of the power grid. One of those is the implementation of 'wide area measurements' using phasor measurement units (PMUs) to dynamically monitor the operations and the status of the network and provide advanced situational awareness and stability assessment. This project seeks to obtain PMU data from wind power plants and grid reference points and develop software tools to analyze and visualize synchrophasor data for the purpose of better understanding wind power plant dynamic behaviors under normal and contingency conditions.

17 WIND ENERGY↗

PMU Data Event Detection: A User Guide for Power Engineers

This user guide is intended to accompany a software package containing a Matrix Laboratory (MATLAB) script and related functions for processing phasor measurement unit (PMU) data. This package and guide have been developed by the National Renewable Energy Laboratory and the University of Texas at Austin. The objective of this data processing exercise is to discover events in the vast quantities of data collected by PMUs. This document attempts to cover some of the theory behind processing the data to isolate events as well as the functioning of the MATLAB scripts. The report describes (1) the algorithms and mathematical background that the accompanying MATLAB codes use to detect events in PMU data and (2) the inputs required from the user and the outputs generated by the scripts.

17 WIND ENERGY↗

Integration of a Self-Coherence Algorithm into DISAT for Forced Oscillation Detection

With the increasing number of phasor measurement units on the power system, behaviors typically not observable on the power system are becoming more apparent. Oscillatory behavior on the power system, notably forced oscillations, are one such behavior. However, the large amounts of data coming from the PMUs makes manually detecting and locating these oscillations difficult. To automate portions of the process, an oscillation detection routine was coded into the Data Integrity and Situational Awareness Tool (DISAT) framework. Integration into the DISAT framework allows forced oscillations to be detected and information about the event provided to operational engineers. The oscillation detection algorithm integrates with the data handling and atypical data detecting capabilities of DISAT, building off of a standard library of functions. This report details that integration with information on the algorithm, some implementation issues, and some sample results from the western United States’ power grid.

Forced oscillations↗

Impact of Measurement Error on Synchrophasor Applications

Phasor measurement units (PMUs), a type of synchrophasor, are powerful diagnostic tools that can help avert catastrophic failures in the power grid. Because of this, PMU measurement errors are particularly worrisome. This report examines the internal and external factors contributing to PMU phase angle and frequency measurement errors and gives a reasonable explanation for them. It also analyzes the impact of those measurement errors on several synchrophasor applications: event location detection, oscillation detection, islanding detection, and dynamic line rating. The primary finding is that dynamic line rating is more likely to be influenced by measurement error. Other findings include the possibility of reporting nonoscillatory activity as an oscillation as the result of error, failing to detect oscillations submerged by error, and the unlikely impact of error on event location and islanding detection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fluid-Structure Interaction of Deforming Porous Media

Sandia National Laboratories (SNL) and the Procter and Gamble Company (P&G) collaborated to develop a computational tool that predicts the in-use performance of consumer good products based on specific loading, geometries, materials, and boundary conditions. This computational tool is particularly useful in exploring the consumer-product interface and product performance. The benefit to P&G was many-fold, as the numerous project-tasks that were funded under this agreement led to advanced analysis software that allowed P&G to improve the performance and manufacturing of many of their products across several business units. The benefit to SNL was many-fold as well, including improved reduced-order models for thin-region dynamics (used for customers through DSA, NW, and EC PMUs), improved computational mechanics capability for capillary hydrodynamics, porous flow, structural mechanics, and more. Example applications of these improved capabilities at SNL include, but are not limited to, encapsulation, welding, soldering, and brazing models for NW, interface sliding models for DoD SPP programs, and porous-elastic subsidence modeling for energy and climate applications. Moreover, many current code developers on the ASC program’s SIERRA applications gained valuable skills working on this CRADA.

97 MATHEMATICS AND COMPUTING↗

Use and Testing of a Wind Turbine for the Supply of Balancing Reserves and Wide-Area Grid Stability

This report documents the use of wind turbine inertial energy for the supply of two specific electric power grid services; system balancing and real power modulation to improve grid stability. Each service is developed to require zero net energy consumption. Grid stability was accomplished by modulating the real power output of the wind turbine at a frequency and phase associated with wide-area modes. System balancing was conducted using a grid frequency signal that was high-pass filtered to ensure zero net energy. Both services used Phasor Measurement Units (PMUs) as their primary source of system data in a feedforward control (for system balancing) and feedback control (for system stability).

17 WIND ENERGY↗