Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Industrial ion source technology

Plasma probe surveys were conducted in a 30-cm source to verify that the uniformity in the ion beam is the result of a corresponding uniformity in the discharge-chamber plasma. A 15 cm permanent magnet multipole ion source was designed, fabricated, and demonstrated. Procedures were investigated for texturing a variety of seed and surface materials for controlling secondary electron emission, increasing electron absorption of light, and improved attachment of biological tissue for medical implants using argon and tetrafluoromethane as the working gases. The cross section for argon-argon elastic collisions in the ion-beam energy range was calculated from interaction potentials and permits calculation of beam interaction effects that can determine system pumping requirements. The data also indicate that different optimizations of ion-beam machines will be advantageous for long and short runs, with 1 mA-hr/cm being the rough dividing line for run length. The capacity to simultaneously optimize components in an ion-beam machine for a single application, a capacity that is not evident in competitive approaches such as diode sputtering is emphasized.

Kaufman, H. R.↗

Plasma diagnostic method using intermodulation frequencies in a Langmuir probe

A plasma diagnostic method using intermodulation frequencies is developed. When dual-frequency (ω{sub 1},ω{sub 2}) voltage signals are applied to a probe, the intermodulation frequencies (ω{sub 2}±ω{sub 1}, ω{sub 2}±2ω{sub 1}) between the signals are generated due to the nonlinearity of the sheath. From the analysis of the intermodulation frequencies, the plasma parameters, such as the electron temperature and the plasma density, can be obtained. The measured plasma parameters from this method are compared to the results from the measured electron energy distribution function, and they are in good agreement. Because the intermodulation currents originated from the plasma not from the stray component of the measurement system, an accurate measurement of the plasma parameters is achievable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Behavior of Triple Langmuir Probes in Non-Equilibrium Plasmas

The triple Langmuir probe is an electrostatic probe in which three probe tips collect current when inserted into a plasma. The triple probe differs from a simple single Langmuir probe in the nature of the voltage applied to the probe tips. In the single probe, a swept voltage is applied to the probe tip to acquire a waveform showing the collected current as a function of applied voltage (I-V curve). In a triple probe three probe tips are electrically coupled to each other with constant voltages applied between each of the tips. The voltages are selected such that they would represent three points on the single Langmuir probe I-V curve. Elimination of the voltage sweep makes it possible to measure time-varying plasma properties in transient plasmas. Under the assumption of a Maxwellian plasma, one can determine the time-varying plasma temperature T(sub e)(t) and number density n(sub e)(t) from the applied voltage levels and the time-histories of the collected currents. In the present paper we examine the theory of triple probe operation, specifically focusing on the assumption of a Maxwellian plasma. Triple probe measurements have been widely employed for a number of pulsed and timevarying plasmas, including pulsed plasma thrusters (PPTs), dense plasma focus devices, plasma flows, and fusion experiments. While the equilibrium assumption may be justified for some applications, it is unlikely that it is fully justifiable for all pulsed and time-varying plasmas or for all times during the pulse of a plasma device. To examine a simple non-equilibrium plasma case, we return to basic governing equations of probe current collection and compute the current to the probes for a distribution function consisting of two Maxwellian distributions with different temperatures (the two-temperature Maxwellian). A variation of this method is also employed, where one of the Maxwellians is offset from zero (in velocity space) to add a suprathermal beam of electrons to the tail of the main Maxwellian distribution (the bump-on-the-tail distribution function). For a range of parameters in these non-Maxwellian distributions, we compute the current collection to the probes. We compare the distribution function that was assumed a priori with the distribution function one would infer when applying standard triple probe theory to analyze the collected currents. For the assumed class of non-Maxwellian distribution functions this serves to illustrate the effect a non-Maxwellian plasma would have on results interpreted using the equilibrium triple probe current collection theory, allowing us to state the magnitudes of these deviations as a function of the assumed distribution function properties.

Polzin, Kurt A.↗

Thomson scattering in short pulse laser experiments

Thomson scattering is well used as a diagnostic in many areas of high energy density physics. In this paper, we quantitatively demonstrate the practicality of using Thomson scattering as a diagnostic of short-pulse laser-plasma experiments in the regime, where the plasmas probed are at solid density and have temperatures of many hundreds of eV using a backlighter produced with an optical laser. This method allows a diagnosis both spatially and temporally of the density and temperature distributions in high energy density laser-plasma interactions which is independent from, and would act as a useful complement to, the existing spectroscopic methods.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectroscopic diagnostics of high-temperature plasma in stellar coronae using Fe XXIV-XXIV K-shell lines with XRISM

The RS CVn type binary star GT Muscae was observed during its quiescence using the Resolve X-ray microcalorimeter spectrometer onboard XRISM. The main and satellite lines of the Fe XXIV-XXIV K-shell transitions were resolved for the first time from stellar sources. We conducted line ratio analysis to investigate any deviations from collisional ionization equilibrium and Maxwell electron energy distribution with a single temperature. By using five combinations of direct excitation lines and dielectronic recombination satellite lines in three line complexes (Fe He$\alpha$, Ly$\alpha$, and He$\beta$), we found that the plasma is well characterized by two-temperature thermal plasmas with temperatures of 1.7 and 4.3 keV, which is consistent with thermal broadening of Fe xxv, and the broad-band fitting results in the 1.7–10 keV band. Other forms of deviation from a single-temperature plasma, such as different ionization and electron temperatures or the $\kappa$ distribution for the electron energy distributions, are not favored, which is reasonable for stellar coronae at quiescence. This study demonstrates the utility of the Fe K-shell line ratio diagnostics to probe plasma conditions using X-ray microcalorimeters.

X-rays: stars↗

Variations in plasma characteristics near D sheets in the solar wind

A strong interplanetary shock was detected by the Pioneer 8 magnetometer, plasma probe, and wave instrument at 0048 UT, on June 11, 1968. During the rest of this day the interplanetary medium was highly disturbed as seven well-defined current layers or D sheets, as well as a number of other localized interaction regions, swept past the spacecraft. The local plasma characteristics that were best correlated with passage of the D sheets appeared to involve changes in the suprathermal electron population. Changes in the 400-Hz wave levels were also detected near the discontinuities during periods when the local ion plasma frequency was near 400 Hz, but the limited measurement capability of the Pioneer 8 wave instrument does not allow an unambiguous identification of the wave-particle interactions associated with these measurements.

Scarf, F. L.↗

Characterization of an inductively coupled nitrogen-argon plasma by Langmuir probe combined with optical emission spectroscopy

The properties of low-pressure inductively coupled nitrogen-argon plasmas were investigated by using a Langmuir probe combined with optical emission spectroscopy (OES) under the conditions of pressures in the range of 1-30 mTorr and applied rf powers of 200-600 W. In the experiments, the argon was introduced as an actinometer and as an adding gas. The effect of the argon content in the gas mixture was examined in the range of 5%-80%. The electron energy probability function (EEPF), the electron density, and the electron temperature were obtained by using an rf-compensated Langmuir probe. The dissociation fractions were obtained from the OES actinometry. The electron temperature was also obtained by OES corona model and compared with that measured by the probe. The second positive and first negative systems of spectral bands from nitrogen molecules were analyzed to estimate the vibrational and rotational temperatures. The effects of the control parameters on the plasma parameters and dissociation fraction were investigated. While the calculated nitrogen atom density increased with power, it exhibited a maximum value near the Ar content of 30%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel femtosecond-gated, high-resolution, frequency-shifted shearing interferometry technique for probing pre-plasma expansion in ultra-intense laser experiments

Ultra-intense laser-matter interaction experiments (>10{sup 18} W/cm{sup 2}) with dense targets are highly sensitive to the effect of laser “noise” (in the form of pre-pulses) preceding the main ultra-intense pulse. These system-dependent pre-pulses in the nanosecond and/or picosecond regimes are often intense enough to modify the target significantly by ionizing and forming a plasma layer in front of the target before the arrival of the main pulse. Time resolved interferometry offers a robust way to characterize the expanding plasma during this period. We have developed a novel pump-probe interferometry system for an ultra-intense laser experiment that uses two short-pulse amplifiers synchronized by one ultra-fast seed oscillator to achieve 40-fs time resolution over hundreds of nanoseconds, using a variable delay line and other techniques. The first of these amplifiers acts as the pump and delivers maximal energy to the interaction region. The second amplifier is frequency shifted and then frequency doubled to generate the femtosecond probe pulse. After passing through the laser-target interaction region, the probe pulse is split and recombined in a laterally sheared Michelson interferometer. Importantly, the frequency shift in the probe allows strong plasma self-emission at the second harmonic of the pump to be filtered out, allowing plasma expansion near the critical surface and elsewhere to be clearly visible in the interferograms. To aid in the reconstruction of phase dependent imagery from fringe shifts, three separate 120° phase-shifted (temporally sheared) interferograms are acquired for each probe delay. Three-phase reconstructions of the electron densities are then inferred by Abel inversion. This interferometric system delivers precise measurements of pre-plasma expansion that can identify the condition of the target at the moment that the ultra-intense pulse arrives. Such measurements are indispensable for correlating laser pre-pulse measurements with instantaneous plasma profiles and for enabling realistic Particle-in-Cell simulations of the ultra-intense laser-matter interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Average solar wind proton properties from Pioneers 6 and 7.

Distributions and average values for the proton speed, azimuthal and polar flow directions, and the proton temperature and density in the solar wind are presented. The data are obtained from the Ames plasma probes on Pioneers 6 and 7. The time periods covered include Dec. 18, 1965 to mid-February 1966, and mid-August to mid-October 1966. The distributions of the parameters, except for the polar flow direction, are skewed, partially because of stream-stream interactions in the solar wind. The average values of the basic plasma parameters from the two spacecraft are different which could be due partially to different solar activity at the two times, and partially to sector and beam structure dependence.

Mihalov, J. D.↗

Study of Coronal Heating in Solar Active Regions Using Wide-Field Imaging Spectroscopy: Hinode EIS Slot Observations

Understanding the frequency of heating events that keep the coronal plasma at several million Kelvin above the photospheric temperature of~ 6000K, is one of the most important problems in solar astrophysics. Spectroscopic observations of the Sun in the extreme ultraviolet (EUV) indicate that the coronal plasma reaches temperatures from 1 to 5 MK in active regions. It is also established that temperature in active regions can vary strongly with time and, moreover, contain sub-regions that evolve and develop separately. Tracking the spatio-temporal evolution of temperature requires continuous observation of the entire active region via imaging and spectroscopy. Traditional slit imaging spectroscopy probes plasma heating in solar active regions through observations of diagnostic emission lines and the resulting data are spectrally pure. Here, imaging is performed through rastering process, which severely limits co-temporal observations and often can be slow to miss events that evolve at other portions of the active region. In contrast, wide-field imaging spectroscopy offer simultaneous coverage of a large field of view as well as obtain spectral information in the same direction. This data suffers from spatial-spectral confusion, and are called spectroheliograms. Using the state-of-the-art inversion techniques that are developed recently, now spectroheliogram data can be unfolded to yield spectrally pure maps of large fields over long duration of observations. We use wide slit data, usually referred as ‘slot’, from the EUV Imaging Spectrometer (EIS) onboard Hinode satellite, focusing on active region observations. Here, we present our study of coronal heating in an active region using a long duration Hinode EIS slot observation.

Active region heating↗

A synchronized emissive probe for time-resolved plasma potential measurements of pulsed discharges

A pulsed emissive probe technique is presented for measuring the plasma potential of pulsed plasma discharges. The technique provides time-resolved data and features minimal disturbance of the plasma achieved by alternating probe heating with the generation of plasma. Time resolution of about 20 ns is demonstrated for high power impulse magnetron sputtering (HIPIMS) plasma of niobium in argon. Spatial resolution of about 1 mm is achieved by using a miniature tungsten filament mounted on a precision translational stage. Repeated measurements for the same discharge conditions show that the standard deviation of the measurements is about 1-2 V, corresponding to 4%-8% of the maximum plasma potential relative to ground. The principle is demonstrated for measurements at a distance of 30 mm from the target, for different radial positions, at an argon pressure of 0.3 Pa, a cathode voltage of -420 V, and a discharge current of about 60 A in the steady-state phase of the HIPIMS pulse.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pioneer 7 observations of the August 29, 1966, interplanetary shock-wave ensemble.

The detailed plasma (except for electrons) and magnetic field data from Pioneer 7 are presented for a proposed double-shock ensemble. The Ames Research Center plasma probe data are compared with that of the MIT probe. These data are compared with MHD theory to show that the discontinuities themselves satisfy the magnetic Hugoniot equations. The data are also compared with the theoretical predictions for the double-shock structure. The theory requires as input only the forward shock velocity, the original ambient solar wind conditions, and a reasonable assumption regarding the density and azimuthal magnetic field in the 'new' solar wind which is detected after passage of the reverse shock. A unique solution is then obtained for the theoretical piston and reverse shock positions as well as for the temporal plasma behavior for both infinite and finite electrical conductivities.

Dryer, M.↗

Magnetospheric Substorms and Tail Dynamics

This grant funded several studies of magnetospheric substorms and their effect on the dynamics of the earth's geomagnetic tail. We completed an extensive study of plasmoids, plasma/magnetic field structures that travel rapidly down the tail, using data from the ISEE 3 and IMP 8 spacecraft. This study formed the PhD thesis of Mark Moldwin. We found that magnetically plasmoids are better described as flux-ropes (twisted magnetic flux tubes) rather than plasma bubbles, as had been generally regarded up to that point (Moldwin and Hughes, 1990; 1991). We published several examples of plasmoids observed first in the near tail by IMP 8 and later in the distant tail by ISEE 3, confirming their velocities down tail. We showed how the passage of plasmoids distorts the plasma sheet. We completed the first extensive statistical survey of plasmoids that showed how plasmoids evolve as they move down tail from their formation around 30 RE to ISEE 3 apogee at 240 RE. We established a one-to-one correspondence between the observation of plasmoids in the distant tail and substorm onsets at earth or in the near tail. And we showed that there is a class of plasmoid-like structures that move slowly earthward, especially following weak substorms during northward IMF. Collectively this work constituted the most extensive study of plasmoids prior to the work that has now been done with the GEOTAIL spacecraft. Following our work on plasmoids, we turned our attention to signatures of substorm onset observed in the inner magnetosphere near geosynchronous orbit, especially signatures observed by the CRRES satellite. Using data from the magnetometer, electric field probe, plasma wave instrument, and low energy plasma instrument on CRRES we were able to better document substorm onsets in the inner magnetosphere than had been possible previously. Detailed calculation of the Poynting flux showed energy exchange between the magnetosphere and ionosphere, and a short burst of tailward convective flow just prior to onset, suggesting the active role of the ionosphere in the onset process, and adding credibility to the ballooning instability theory of substorm onset. This grant also supported a number of other substorm studies and reviews. These are represented by the list of publications and meeting presentations resulting out of this grant.

Hughes, W. Jeffrey↗

Lunar Vehicle Active Charge Control System (LVACCS)+

The Lunar Vehicle Active Charge Control System (LVACCS) is an instrument in development that will measure the electrical potential of a spacecraft or rover under both positive and negative charge conditions, actively discharge negative charge, and charge the vehicle to a safe positive potential. All surfaces immersed in a plasma charge to non-zero potentials. In very low-density plasma (< 100 cm^-3), space vehicle charging can interfere with plasma probe measurements, degrade avionics performance, or cause a total system failure. LVACCS provides real-time in-situ space situational awareness that overcome these challenges in a small package. LVACCS has been awarded a NASA PICASSO grant to bring the instrument to technology readiness level 5. LVACCS consists of two main components: a collimated photoelectron gun (CPEG) and a Spacecraft Charge Detector (SCD).Monitoring charge build up on the lunar surface isa critical first step to understand hazards for crew, rovers, and instrumentation operating there.The LVACCS instrument will be able to fill in this gap providing robust lunar surface potential measurements and active charge dissipation.

Moon↗

Langmuir probe diagnostics of plasma in high current electron cyclotron resonance proton ion source

A high current Electron Cyclotron Resonance (ECR) proton ion source has been developed for low energy high intensity proton accelerator at Bhabha Atomic Research Centre. Langmuir probe diagnostics of the plasma generated in this proton ion source is performed using Langmuir probe. The diagnostics of plasma in the ion source is important as it determines beam parameters of the ion source, i.e., beam current, emittance, and available species. The plasma parameter measurement in the ion source is performed in continuously working and pulsed mode using hydrogen as plasma generation gas. The measurement is performed in the ECR zone for operating pressure and microwave power range of 10{sup −4}–10{sup −3} mbar and 400–1000 W. An automated Langmuir probe diagnostics unit with data acquisition system is developed to measure these parameters. The diagnostics studies indicate that the plasma density and plasma electron temperature measured are in the range 5.6 × 10{sup 10} cm{sup −3} to 3.8 × 10{sup 11} cm{sup −3} and 4–14 eV, respectively. Using this plasma, ion beam current of tens of mA is extracted. The variations of plasma parameters with microwave power, gas pressure, and radial location of the probe have been studied.

43 PARTICLE ACCELERATORS↗

Design of a millimeter-wave polarimeter for NSTX-Upgrade and initial test on DIII-D

Polarimetry is a powerful diagnostic technique to probe plasma equilibria and magnetic fluctuations in fusion plasmas. In a high beta plasma such as the National Spherical Torus eXperiment (NSTX), these measurements are important to understand plasma stability and anomalous transport. A 288 GHz polarimeter operating along a major radial chord in retroreflection geometry has been developed and is being tested on the DIII-D tokamak to prepare for future implementation on NSTX-Upgrade. The system launches a rotating linearly polarized beam and detects the phase shift directly related to the polarization change caused by the plasma. To accomplish this, a pair of orthogonal linearly polarized beams with a stable difference frequency is generated using a single sideband modulation technique, then combined and transformed to be counter-rotating circularly polarized. To improve phase resolution, quasi-optical isolation, using Faraday rotators and polarizers, is utilized to eliminate a multi-path feedback effect, which is found to be the primary source of phase error. The bench tests in the laboratory and DIII-D power supply test discharges indicate {<=}1 Degree-Sign phase resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the hydrodynamics and emission of a laser heated tamped high-Z target

We examine the hydrodynamic expansion and x-ray emission of a laser-heated buried-layer target. This research is motivated by our interest in developing an experimental platform for probing plasma properties under relatively uniform conditions, such as ionization and equation of state. Targets consist of a few thousand angstrom-thick layer of material, embedded in a few microns of the tamper material (typically beryllium), which are irradiated on both sides by an intense few-nanosecond laser pulse. The expansion and emission of our target, composed of a homogeneous mixture of iron, vanadium, and gold, are simulated using the 2-D LASNEX code. Reasonable agreement is found with the time history of the x-ray emission traces (DANTE). Both experiments and simulations exhibit an interesting reduction in the radial size of the emission region with time, as measured using face-on imaging. This is demonstrated to be due to the ablation of the beryllium tamper, which affects the radial confinement of the embedded target. Simulations using a larger diameter beryllium tamper are found to mitigate this effect, improving the one-dimensionality of the expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗