Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PINCH DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Ion flow measurements and plasma current analysis in the Irvine Field Reversed Configuration

Measurements of the Doppler shift of impurity lines indicate that there is an ion flow of {approx}7 km/s in the Irvine Field Reversed Configuration. A charge-exchange neutral particle analyzer shows the peak energy is below the 20 eV minimum detectable energy threshold, which is in agreement with the spectroscopic data. By evaluating the collision times between the impurities and hydrogen, the dominant plasma ion species, it is concluded that the ions rotate with an angular frequency of {approx}4x10{sup 4} rad/s. Estimates of the ion current in the laboratory frame indicate it is one to two orders of magnitude larger than the measured plasma current of 15 kA. Electron drifts are expected to cancel most of the ion current based on the measured magnetic fields and calculated electric fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulsed current wave shaping with a transmission line by utilizing superposition of a forward and a backward voltage wave for fast capillary Z-pinch discharge

By using a water transmission line, current wave shaping was demonstrated for a fast capillary Z-pinch discharge recombination soft x-ray laser study. The pulsed power system consists of a water capacitor, a gap switch, a transmission line, and a capillary plasma load. A voltage wave initiated at the water capacitor propagates toward the capillary load through the transmission line. Control of the pulse delay that occurred in the transmission line provides the superposition of the forward and the backward voltage waves effectively in order to perform current wave shaping with higher current amplitude and rapid current decay.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum-dot-array diffraction grating with single order diffraction property for soft x-ray region

A gold transmission grating is used routinely to disperse the x-ray spectrum at the Z soft x-ray facility to measure the spectrum and temporal history of the absolute soft x-ray power emitted from z-pinch and hohlraum radiation sources. A quantum-dot-array diffraction grating (QDADG) of 250 lines/mm for soft x-ray is designed and fabricated for the first time according to the principle of binary sinusoidal transmission grating. The diffraction efficiencies of the grating are measured in the 150-300 eV photon energy range on the Beamline 3W1B of Beijing Synchrotron Radiation Facility. This article describes the basic concept and calibration techniques and presents calibration results. It is shown that the 250 lines/mm QDADG can be used to disperse light without higher-order diffractions in soft x-ray range, and the diffraction efficiencies of this grating are nearly constant (about 25%), which is beneficial in the spectrum analysis.

43 PARTICLE ACCELERATORS↗

Optical measurements for turbulence characterization in RFX-mod edge

The edge of the reversed field pinch experiment RFX-mod (R=2 m, a=0.46 m) is characterized by a complex magnetic topology and strong pressure gradients. A set of fast spectroscopic diagnostics has been designed to characterize both main plasma edge parameters and turbulence, including coherent structures (blobs) and radial profiles of the thermodynamic variables. Measurements of the edge radial profiles of electron density (n{sub e}), temperature (T{sub e}), and pressure (P{sub e}) are obtained by a thermal helium beam diagnostic, which locally measures the ratios of the spectral lines emitted by a neutral He cloud puffed into hydrogen plasma discharges. A gas puff imaging system allows the high frequency (1 MHz bandwidth) measurement of the fluctuations of He I emissivity in the same positions. The system measures both the intermittent behavior of the edge turbulence and n{sub e}, T{sub e}, and P{sub e} profiles of the corresponding coherent structures, with a resolution down to 6 {mu}s. The optical diagnostics are complemented by a set of triaxial magnetic coils to simultaneously characterize the edge magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectroscopic measurement of ion temperature and ion velocity distributions in the flux-coil generated FRC

One aim of the flux-coil generated field reversed configuration at Tri Alpha Energy (TAE) is to establish the plasma where the ion rotational energy is greater than the ion thermal energy. To verify this, an optical diagnostic was developed to simultaneously measure the Doppler velocity-shift and line-broadening using a 0.75 m, 1800 groves/mm, spectrometer. The output spectrum is magnified and imaged onto a 16-channel photomultiplier tube (PMT) array. The individual PMT outputs are coupled to high-gain, high-frequency, transimpedance amplifiers, providing fast-time response. The Doppler spectroscopy measurements, along with a survey spectrometer and photodiode-light detector, form a suite of diagnostics that provide insights into the time evolution of the plasma-ion distribution and current when accelerated by an azimuthal-electric field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boost of plasma current with active magnetic field shaping coils in rotamak discharges

A set of magnetic shaping coils is installed on the Prairie View (PV) rotamak for the study of active plasma shape control in the regimes with and without toroidal field (TF). In the spherical tokamak regime (with TF), plasma current I{sub p} can be boosted by 200% when all five shaping coils (connected in series) are energized. The enhancement of current drive efficiency is mainly attributed to the radial compression and the substantially axial extension of the plasma column; this in turn improves the impedance matching and thus increases antenna input power. In the field-reversed configuration (without TF), plasma current can be boosted by 100% when one middle coil is used; the appearance of radial shift mode limits the achievable value of I{sub p}. The experiments clearly demonstrate that the plasma shape control plays a role in effectively driving plasma current in rotamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of toroidal magnetic field on n = 1 mode stability in rotamak plasmas

To study the effect of toroidal magnetic field on n = 1 mode stability, a series of experiments with linearly ramping the axial current I{sub z}, which makes field-reversed configuration (FRC) to spherical tokamak (ST) transition, have been conducted in rotamak. Results clearly demonstrate that the tilt mode can be completely suppressed by small I{sub z} around 0.4 kA (in comparison with 2.0 kA plasma current). An unknown new mode with larger magnetic perturbations is triggered when I{sub z} reaches 0.5 kA. This instability mode keeps saturation while plasma current is boosted when I{sub z} is in the range of 0.6-1.4 kA. When I{sub z} exceeds 1.6 kA, the new mode suddenly disappears and discharge is free from instability modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Grazing incidence extreme ultraviolet spectrometer fielded with time resolution in a hostile Z-pinch environment

This recently developed diagnostic was designed to allow for time-gated spectroscopic study of the EUV radiation (4 nm < {lambda} < 15 nm) present during harsh wire array z-pinch implosions. The spectrometer utilizes a 25 {mu}m slit, an array of 3 spherical blazed gratings at grazing incidence, and a microchannel plate (MCP) detector placed in an off-Rowland position. Each grating is positioned such that its diffracted radiation is cast over two of the six total independently timed frames of the MCP. The off-Rowland configuration allows for a much greater spectral density on the imaging plate but only focuses at one wavelength per grating. The focal wavelengths are chosen for their diagnostic significance. Testing was conducted at the Zebra pulsed-power generator (1 MA, 100 ns risetime) at University of Nevada, Reno on a series of wire array z-pinch loads. Within this harsh z-pinch environment, radiation yields routinely exceed 20 kJ in the EUV and soft x-ray. There are also strong mechanical shocks, high velocity debris, sudden vacuum changes during operation, energic ion beams, and hard x-ray radiation in excess of 50 keV. The spectra obtained from the precursor plasma of an Al double planar wire array contained lines of Al IX and AlX ions indicating a temperature near 60 eV during precursor formation. Detailed results will be presented showing the fielding specifications and the techniques used to extract important plasma parameters using this spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deconvolution of Stark broadened spectra for multi-point density measurements in a flow Z-pinch

Stark broadened emission spectra, once separated from other broadening effects, provide a convenient non-perturbing means of making plasma density measurements. A deconvolution technique has been developed to measure plasma densities in the ZaP flow Z-pinch experiment. The ZaP experiment uses sheared flow to mitigate MHD instabilities. The pinches exhibit Stark broadened emission spectra, which are captured at 20 locations using a multi-chord spectroscopic system. Spectra that are time- and chord-integrated are well approximated by a Voigt function. The proposed method simultaneously resolves plasma electron density and ion temperature by deconvolving the spectral Voigt profile into constituent functions: a Gaussian function associated with instrument effects and Doppler broadening by temperature; and a Lorentzian function associated with Stark broadening by electron density. The method uses analytic Fourier transforms of the constituent functions to fit the Voigt profile in the Fourier domain. The method is discussed and compared to a basic least-squares fit. The Fourier transform fitting routine requires fewer fitting parameters and shows promise in being less susceptible to instrumental noise and to contamination from neighboring spectral lines. The method is evaluated and tested using simulated lines and is applied to experimental data for the 229.69 nm C III line from multiple chords to determine plasma density and temperature across the diameter of the pinch. These measurements are used to gain a better understanding of Z-pinch equilibria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active control of the resistive wall mode with power saturation

An analytic model of non-linear feedback stabilization of the resistive wall mode is presented. The non-linearity comes from either the current or the voltage saturation of the control coil power supply. For the so-called flux-to-current control, the current saturation of active coils always results in the loss of control. On the contrary, the flux-to-voltage control scheme tolerates certain degree of the voltage saturation. The minimal voltage limit is calculated, below which the control will be lost.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A dual-channel, focusing x-ray spectrograph with uniform dispersion for Z pinch plasmas measurement

A dual-channel, focusing x-ray spectrograph with uniform dispersion (i.e., the linear dispersion of this spectrograph is a constant) is described for measuring the x-ray spectra emission from the hot, dense Al Z pinch plasmas. The spectrograph uses double uniform-dispersed crystals (e.g., a Quartz 1010 crystal and a Mica 002 crystal) as dispersion elements and a double-film box as detector to achieve the simultaneous recording of the time integrated spectrum covering a wide spectral range of {approx}5-9 A. Since this spectrograph disperse the x-rays on the detector plane with uniform spacing for every wavelength, it needs not the calibration of the wavelength with spatial coordinate, thereby own the advantages of easiness and veracity for spectra identification. The design of this spectrograph and the example of experiment on the ''Yang'' accelerator are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Minimum energy states of the cylindrical plasma pinch in single-fluid and Hall magnetohydrodynamics

Relaxed states of a plasma column are found analytically in single-fluid and Hall magnetohydrodynamics (MHD). We perform complete minimization of the energy with constraints imposed by invariants inherent in the corresponding models. It is shown that the relaxed state in Hall MHD is a force-free magnetic field with uniform axial flow and/or rigid azimuthal rotation. In contrast, the relaxed states in single-fluid MHD are more complex due to the coupling between velocity and magnetic field. Cylindrically and helically symmetric relaxed states are considered for both models. Helical states may be time dependent and analogous to helical waves, propagating on a cylindrically symmetric background. Application of our results to reversed-field pinches (RFP) is discussed. The radial profile of the parallel momentum predicted by the single-fluid MHD relaxation theory is shown to be in reasonable agreement with experimental observation from the Madison symmetric torus RFP experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical investigation on the implosion dynamics of wire-array Z-pinches in (r, {theta}) geometry

The implosion dynamics of wire-array Z-pinches are investigated numerically in 2D (r, {theta}) geometry by using a resistive MHD code. It is assumed that the wires have expanded to plasmas with diameter d{sub 0}, which is used as the initial condition for the consequent implosion process. In fact, the explosion process of individual wires is not included. By changing d{sub 0}, the effects of the wire expansion degree on the implosion dynamics are analyzed. When d{sub 0} is larger, the current density is more concentrated at the outer side of the wires and the fraction of current flow around the wire plasmas is nearly in proportion to d{sub 0}. As a result, the ablation rate of wires is increased and the implosion phase starts earlier. This conclusion agrees with the simulation works of other authors [Chittenden et al., Phys. Plasmas 11(3), 1118 (2004)]. When the array radius and initial wire plasma diameter are fixed, the increase of wire number leads to the azimuthal merge of wires during implosion. When the wires number exceed a critical value, which is related to d{sub 0}, wire plasmas can merge to a continuous shell with an azimuthal perturbation in density, which depends on the initial wires number.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density fluctuation measurements by far-forward collective scattering in the MST reversed-field pinch

The multichannel polarimeter-interferometer system on the MST reversed-field pinch can be utilized to measure far-forward collective scattering from electron density fluctuations. The collective scattering system has 11 viewing chords with {approx}8 cm spacing. The source is a 432 {mu}m (694 GHz) far infrared laser and the scattered power is measured using a heterodyne detection scheme. Collective scattering provides a line-integrated measurement of fluctuations within the divergence of the probe beam covering wavenumber range: k{sub Up-Tack} < 1.3 cm{sup -1}, corresponding k{sub Up-Tack }{rho}{sub s} < 1.3 ({rho}{sub s} is the ion-sound Larmor radius), the region of primary interest for turbulent fluctuation-induced transport. The perpendicular wavenumber consists of toroidal, poloidal, and radial contributions, which vary with chord position. Coherent modes associated with tearing instabilities and neutral-beam driven fast particles are observed along with broadband turbulence at frequencies up to 500 kHz. Changes in frequency are consistent with a Doppler shift due to parallel plasma flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved ion energy distribution measurements using an advanced neutral particle analyzer on the MST reversed-field pinch

An advanced neutral particle analyzer (ANPA) capable of simultaneously measuring hydrogen and deuterium ions of energies up to 45 keV has recently been developed for use on the Madison Symmetric Torus. The charge-to-mass separation allows for separate analysis of bulk deuterium ions and hydrogen ions injected with a 1 MW, 25 keV neutral beam. Orientation of the ANPA allows sampling of different regions of ion velocity space; a radial viewport favors collection of ions with high v{sub Up-Tack }/ Double-Vertical-Line v Double-Vertical-Line while a recently installed tangential viewport favors ions with high v{sub Double-Vertical-Line Double-Vertical-Line }/ Double-Vertical-Line v Double-Vertical-Line , such as those from the core-localized fast ion population created by the neutral beam. Signals are observed in the ANPA's highest energy channels during periodic magnetic reconnection events, which are drivers of anisotropic, non-Maxwellian ion energization in the reversed-field pinch. ANPA signal strength is dependent on the background neutral density, which also increases during magnetic reconnection events, so careful analysis must be performed to identify the true change in the ion distribution. A Monte Carlo neutral particle tracing code (NENE) is used to reconstruct neutral density profiles based on D{sub {alpha}} line emission, which is measured using a 16-chord filtered photodiode array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of an advanced neutral particle analyzer for the Madison Symmetric Torus reversed-field pinch

A new E Parallel-To B neutral particle analyzer, which has recently been installed on Madison Symmetric Torus (MST) reversed-field pinch (RFP), has now been calibrated, allowing the measurement of the fast ion density and energy distribution. This diagnostic, dubbed the advanced neutral particle analyzer (ANPA), can simultaneously produce time resolved measurements of the efflux of both hydrogen and deuterium ions from the plasma over a 35 keV energy range with an energy resolution of 2-4 keV and a time resolution of 10 {mu}s. These capabilities are needed to measure both majority ion heating that occurs during magnetic reconnection events in MST and the behavior of the fast ions from the 1 MW hydrogen neutral beam injector on MST. Calibration of the ANPA was performed using a custom ion source that resides in the flight tube between the MST and the ANPA. In this work, the ANPA will be described, the calibration procedure and results will be discussed, and initial measurements of the time evolution of 25 keV neutral beam injection-born fast ions will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved spectral analysis for the motional Stark effect diagnostic

The magnetic pitch angle and the magnitude from reversed field pinch plasmas in the Madison symmetric torus (MST) have been routinely obtained from fully resolved motional Stark effect (MSE) spectrum analyses. Recently, the spectrum fit procedure has been improved by initializing and constraining the fit parameters based on the MSE model in the atomic data and analysis structure. A collisional-radiative model with level populations nlm-resolved up to n= 4 and a simple Born approximation for ion-impact cross sections is used for this analysis. Measurement uncertainty is quantified by making MSE measurements with multiple views of a single spatial location, ranging 5%-15% for typical MST operation conditions. A multi-view fit improves the goodness of fit of MSE spectral features and background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma density measurements in tungsten wire-array Z-pinches

Measurements of the plasma density profile near the exploding wires in 1 MA tungsten (W) wire-array Z-pinches have been made using calibrated x-ray absorption. As many as 5 x-ray images per pulse were obtained between 65 and 160 ns after the start of the 100 ns rise time current pulse. Measured W ion densities range from above 10{sup 19}/cm{sup 3} close to the wire to {approx}10{sup 17}/cm{sup 3} about 1 mm away from the wire in the plasma stream. After accurate geometrical registration of the individual wires in each successive image in a pulse using the Genetic Algorithm, the temporal evolution of the axial modulation wavelength distribution of the ablation rate from the wires in each array and the global mass-ablation rate as a function of time are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗