Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Large-Area Material and Junction Damage in c–Si Solar Cells by Potential-Induced Degradation

This paper reports a new potential-induced degradation (PID) mechanism for crystalline silicon (c-Si), where Na diffuses everywhere and causes large-area material and junction degradation with point defects. Multiple characterization techniques are combined - Kelvin probe force microscopy, electron-beam induced current, dark lock-in thermography, transmission electron microscopy, time-of-flight secondary-ion mass spectrometry, and microwave photoconductance decay - as well as density functional theory (DFT) calculations. These characterization techniques and theoretical calculations are complementary in various aspects of a material's chemical, structural, electrical, and optoelectrical nature, as well as in atomic, nanometer, micrometer, millimeter, and cell and module scales. All results point consistently to a new discovery: substantial large-area deterioration of materials and junctions play a major role in c-Si PID (in addition to the previously reported local shunting defect caused by Na diffusion to planar defects). Furthermore, this new finding reveals a key PID component and leads to a new strategy for tailoring c-Si photovoltaics to ultimately resolve the PID issue.

14 SOLAR ENERGY↗

Assessment of the feasibility of using transrectal ultrasound for postimplant dosimetry in low-dose-rate prostate brachytherapy

A study was performed to establish whether transrectal ultrasound (TRUS)-based postimplant dosimetry (PID) is both practically feasible and comparable to computed tomography (CT)-based PID, recommended in current published guidelines. In total, 22 patients treated consecutively at a single cancer center with low-dose-rate (LDR) brachytherapy for early-stage prostate cancer had a transrectal ultrasound performed immediately after implant (d0-TRUS) and computed tomography scan 30 days after implant (d30-CT). Postimplant dosimetry planning was performed on both image sets and the results were compared. The interobserver reproducibility of the transrectal ultrasound postimplant dosimetry planning technique was also assessed. It was noticed that there was no significant difference in mean prostate D{sub 90} (136.5 Gy and 144.4 Gy, p = 0.2197), V{sub 100} (86.4% and 89.1%, p = 0.1480) and V{sub 150} (52.0% and 47.8%, p = 0.1657) for d30-CT and d0-TRUS, respectively. Rectal doses were significantly higher for d0-TRUS than d30-CT. Urethral doses were available with d0-TRUS only. We have shown that d0-TRUS PID is a useful tool for assessing the quality of an implant after low-dose-rate prostate brachytherapy and is comparable to d30-CT PID. There are clear advantages to its use in terms of resource and time efficiency both for the clinical team and the patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Imaging charge carriers in potential-induced degradation defects of c-Si solar cells by scanning capacitance microscopy

We report on nm-resolution imaging of charge-carrier distribution around local potential-induced degradation (PID) shunting defects using scanning capacitance microscopy. We imaged on cross sections of heavily field-degraded module areas, cored out and selected by mm-scale photoluminescence imaging. We found localized areas with abnormal carrier behavior induced by the PID defects: the apparent n-type carrier extends vertically into the absorber to ~1-2 um from the cell surface, and laterally in similar lengths; in defect-free areas, the n-type carrier extends ~0.5 um, which is consistent with the junction depth. For comparison, we also investigated areas of the same module exhibiting the least PID stress, and we found no such heavily damaged junction area. Instead, we found slightly abnormal carrier behavior, where the carrier-type inversion in the absorber did not occur, but the p-type carrier concentration changed slightly in a much smaller lateral length of ~300 nm. These nano-electrical findings may indicate a possible mechanism that the existing extended defects, which may not be significantly harmful to cell performance, can be changed by PID to heavily damaged junction areas.

14 SOLAR ENERGY↗

Sensitivity Analysis of Tunable Equation of State Material Model In Pulsed Mercury Target Simulation

A pulsed neutron spallation target is subjected to very short but intense loads from repeated proton pulses. Approximately 60% of the energy from each proton pulse is deposited into the mercury target material and the stainless-steel target structure, leading to a high-pressure region in both the stationary target structure and the flowing mercury. The high-pressure region propagates and leads to fluid-structure interaction. The resultant loading on the target structure containing liquid mercury is difficult to predict, although various simulation approaches and material models for the mercury have been tried. To date, the best match of simulation to experimental data is obtained by using an equation of state (EOS) material model with a specified tensile cutoff pressure, which simulates the cavitation threshold. The inclusion of a threshold to represent cavitation is key to the successful predictions of stress waves triggered by the high-energy pulse striking the mercury and vessel. However, recent measurements of target structure strain show that significant discrepancies remain between the measured and simulated strain values in the EOS mercury model. These differences grow when noncondensable helium gas is intentionally injected into the flowing mercury to reduce the loading on the structure. An EOS-based proportional–integral–derivative (PID) mercury model has been proposed to reduce the gap between the measured and simulated vessel strain responses for targets with gas injection. The conceptual and numerical description and initial investigation of the PID model are presented in previous work. Further studies of this PID model — including the sensitivity of the structure’s strain response to model parameters (the tensile cutoff, PID parameters Kp, Ki, and Kd) — are reported in this article. Results show the strain response is more sensitive to changes in the tensile cutoff value than to changes in the model parameters Kp, Ki, and Kd. These results will aid in future work where the model parameters will be optimized to match simulation data to strain measurements.

Lin, Lianshan↗

Flight representative positive isolation disconnect

Resolutions were developed for each problem encountered and a tradeoff analysis was performed to select a final configuration for a flight representative PID (Positive Isolation Disconnect) that is reduced in size and comparable in weight and pressure drop to the developmental PID. A 6.35 mm (1/4-inch) line size PID was fabricated and tested. The flight representative PID consists of two coupled disconnect halves, each capable of fluid isolation with essentially zero clearance between them for zero leakage upon disconnect half disengagement. An interlocking foolproofing technique prevents uncoupling of disconnect halves prior to fluid isolation. Future development efforts for the Space Shuttle subsystems that would benefit from the use of the positive isolation disconnect are also recommended. Customary units were utilized for principal measurements and calculations with conversion factors being inserted in equations to convert the results to the international system of units.

Rosener, A. A.↗

Determination of stability and control derivatives from the NASA F/A-18 HARV from flight data using the maximum likelihood method

This report is a compilation of PID (Proportional Integral Derivative) results for both longitudinal and lateral directional analysis that was completed during Fall 1994. It had earlier established that the maneuvers available for PID containing independent control surface inputs from OBES were not well suited for extracting the cross-coupling static (i.e., C(sub N beta)) or dynamic (i.e., C(sub Npf)) derivatives. This was due to the fact that these maneuvers were designed with the goal of minimizing any lateral directional motion during longitudinal maneuvers and vice-versa. This allows for greater simplification in the aerodynamic model as far as coupling between longitudinal and lateral directions is concerned. As a result, efforts were made to reanalyze this data and extract static and dynamic derivatives for the F/A-18 HARV (High Angle of Attack Research Vehicle) without the inclusion of the cross-coupling terms such that more accurate estimates of classical model terms could be acquired. Four longitudinal flights containing static PID maneuvers were examined. The classical state equations already available in pEst for alphadot, qdot and thetadot were used. Three lateral directional flights of PID static maneuvers were also examined. The classical state equations already available in pEst for betadot, p dot, rdot and phi dot were used. Enclosed with this document are the full set of longitudinal and lateral directional parameter estimate plots showing coefficient estimates along with Cramer-Rao bounds. In addition, a representative time history match for each type of meneuver tested at each angle of attack is also enclosed.

Napolitano, Marcello R.↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Potential-Induced Degradation of Cu(In,Ga)Se 2 Solar Cells: Alkali Metal Drift and Diffusion Effects

Potential-induced degradation (PID) of photovoltaic modules is due to transport of alkali metal ions (Na + ) from the soda-lime glass (SLG) into the semiconductors. For the most efficient polycrystalline absorbers, Na and K in the Cu(In,Ga)(Se,S) 2 (CIGS) absorber often benefit performance, so a more detailed mechanism for PID is needed. To that end, CIGS solar cells have been encapsulated, stressed with high voltage, and cored to extract the active regions for characterization. SLG substrates led to 14.9% efficiency on average, which reduced to 0% after 25 h of -1000 V bias. This was accompanied by increased Na in the CIGS layer, particularly at the buffer interface, as well as decreased carrier concentrations. On the other hand, borosilicate glass substrates with low Na and high K content led to 13.6% efficiency on average, which only reduced to 12.1% after 25 h of stress. This was accompanied by slightly increased K content in the CIGS layer. As K has led to recent world record efficiency CIGS devices, understanding Na and K similarities and differences may help to enhance initial efficiency and reduce PID.

14 SOLAR ENERGY↗

In-situ Microscopy Characterization of Cu(In,Ga)Se2 Potential-Induced Degradation

We report on the role of sodium in potentialinduced degradation (PID) of Cu(In, Ga)Se 2 (CIGS) solar cells. In-situ microscopy characterizations on AFM platform were performed on two stressed CIGS device under room temperature (RT) and high temperature (HT) at 85 degrees C. During PID stressing we observed depletion region gets wider as Na migrates, p-n junction becomes leaky at RT for over a month; and similar junction evolution was observed for HT-stressed sample, eventually the junction collapsed after 18 hours. The diode behaviors were confirmed by dark I-V measurement. Time-of Flight secondary-ion mass spectrometry reveals that the Na accumulates on ZnO and CdS side, as well as the upper layer of CIGS layer. The results indicate that Na drifted by the voltage applied on the soda-lime glass, then diffuse through the whole device. And the sodium profiles have different points of evolution due to the temperature differences between the two stressed samples. The consistent results unambiguously show how Na from substrate glass causes PID in CIGS solar cells.

14 SOLAR ENERGY↗

Insights into Na + Diffusion in Silicon Modules under Operating Conditions: Measuring Low Concentrations by D-SIMS

Sodium induced shunting under an electric field is a challenging reliability issue in crystalline Si solar modules. The source of this Potential-Induced Degradation of the Shunting type (PID-s) is well understood and its influence on power loss has been intensively studied based on phenomenological models on cell or module level relating the experimental power-loss to stressing parameters (time, temperature, voltage). However, little is known about the Na ion migration kinetics, responsible for PID on a microscopic level, and its quantitative relation to the efficiency degradation. In this paper we present our investigations of sodium ion migration in Ethylene-Vinyl Acetate (EVA) and silicon through Dynamic Secondary Ion Mass Spectroscopy (D-SIMS). Each sample was annealed at field relevant temperatures from 60-90 °C to address typical migration mechanisms of common PV installations. Analysis of the SIMS migration profiles revealed a diffusivity constant D 0,EVA = 0.09 ± 0.14 cm 2 /s and an activation energy E A,EVA = 0.85 ± .04 eV for Na in EVA and diffusivities higher than extrapolated literature values in silicon (D 0,Si = (3.03 ± 2.42)x10 -5 cm 2 /s, and E A,Si = 0.98 ± 0.02 eV). The new insight will be included in a drift-diffusion based degradation model accounting for the partition coefficient across all relevant interfaces. This model can assist in predicting PID-failure in the field based on the given model stack and the diffusion of Na + through each material. Furthermore, this tool can be used for process optimization as well as material selection significantly reducing the cost and time to validate a technology.

14 SOLAR ENERGY↗

Electrochemical Degradation Modes in Bifacial Silicon Photovoltaic Modules

Motivated by the rapidly rising deployment of bifacial monocrystalline-silicon photovoltaics (PV), we investigate the durability of various PV module packaging configurations with transparent coverings on both the front and rear sides of the module. We use a series of bifacial passivated emitter and rear cell (p-PERC) mini-modules with systematically varying outer cover materials (glass/glass, G/G, or glass/transparent backsheet, G/TB) and encapsulant chemistries (poly [ethylene-co-vinyl acetate], EVA; or polyolefin, POE). We study degradation modes over 1,000 hours of combined damp heat (DH) exposure and high system voltages that can cause potential-induced degradation (PID) under positive, zero, or negative 1,000 V cell-to-frame bias. We analyze the degradation modes using a combination of current-voltage measurements, impedance spectroscopy, external quantum efficiency, and spatially resolved luminescence and thermal imaging. Our results highlight various types of degradation including shunting, enhanced recombination, and series resistance increases, and we use spatially resolved characterization to separately identify the localized effects. We show that multiple PID and moisture-ingress degradation modes severely affect EVA-containing modules, with previously reported PID processes under negative-bias DH and a unique observation of rear-side surface recombination in G/EVA/G modules under positive-bias DH. We observe significantly less degradation in POE-containing modules, where the G/POE/G configuration exhibits minimal degradation under all stress conditions that we employ.

14 SOLAR ENERGY↗

Data-Driven Modeling of a High Capacity Cryogenic System for Control Optimization

The Cryogenic Moderator System (CMS) is responsible for maintaining a steady flow of cold neutrons for numerous physics experiments at the Spallation Neutron Source (SNS) in Oak Ridge National Laboratory (ORNL). Sudden losses in beam power, known as beam trips, cause a major disturbance to the CMS due to large step changes in cooling demands. Ongoing efforts on upgrading the neutron beam power from 1.4 to 2.0MW are expected to generate larger transients that can further strain the CMS subsystems if they are not properly controlled. To manage such disturbances, four flow valves and one electric heater are adjusted by five decentralized proportional-integral-derivative (PID) controllers. However, the original PID gains were calibrated empirically based only on tracking performance and not based on disturbance rejection. To address this issue without compromising current CMS operations, a control-oriented model was developed to recalibrate the PID controllers offline. The zero-dimensional (0-D) model was based on simple physics-based principles and data-driven system identification techniques. The CMS was broken into several subsystems for analysis, each of which corresponds to a parametric model tied to the thermodynamic states of the working fluid. The model parameters were identified using the nonlinear least squares method where the residuals were calculated from available sensor data. Simulation results show that the proposed model can capture the dynamics of the CMS at steady state and during beam trips.

Maldonado Puente, Bryan↗

CLARION2-TRINITY: A Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A proximity-focusing RICH detector for the ePIC Experiment at the EIC

The Electron-Proton/Ion Collider Experiment (ePIC) will be a large, multi-purpose detector to be installed at the Electron-Ion Collider (EIC) being built at Brookhaven National Laboratory. As robust particle identification (PID) capabilities are essential for fully realizing the EIC science program, ePIC contains several PID subsystems spanning different angular ranges. PID capability in the electron-going endcap is provided by a proximity-focusing Ring Imaging Cherenkov detector (pfRICH) designed to deliver at least 3σ separation between pions and kaons for momenta up to 7 GeV/ c . It will also aid with electron-hadron discrimination at low momentum and assist in the determination of the collision time (t 0 ). This contribution will summarize the design of the pfRICH as well as ongoing fabrication and component testing efforts. geant-based performance simulations will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of in-situ high-voltage and high-temperature stressing capability on atomic force microscopy platform

Reliability has become an increasingly important issue as photovoltaic technologies mature. However, researching reliability at the nanometer scale is in its infancy; in particular, in-situ studies have not been reported to date. Here, to investigate potential-induced degradation (PID) of solar cell modules, we have developed an in-situ stressing capability with applied high voltage (HV) and high temperature (HT) on an atomic force microscopy (AFM) platform. We designed a sample holder to simultaneously accommodate 1000-V HV and 200 degrees C HT stressing. Three technical challenges have been overcome along with the development: thermal drift at HT, HV interference with measurement, and arc discharge caused by HV. We demonstrated no observable measurement artifact under the stress conditions. Based on our in-situ stressing AFM, Kelvin probe force microscopy potential imaging revealed the evolution of electrical potential across the junction along with the PID stressing time, which provides vital information to further study the PID mechanism.

14 SOLAR ENERGY↗

Optimization of nutrient utilization efficiency and productivity for algal cultures under light and dark cycles using genome-scale model process control

Abstract Algal cultivations are strongly influenced by light and dark cycles. In this study, genome-scale metabolic models were applied to optimize nutrient supply during alternating light and dark cycles of Chlorella vulgaris . This approach lowered the glucose requirement by 75% and nitrate requirement by 23%, respectively, while maintaining high final biomass densities that were more than 80% of glucose-fed heterotrophic culture. Furthermore, by strictly controlling glucose feeding during the alternating cycles based on model-input, yields of biomass, lutein, and fatty acids per gram of glucose were more than threefold higher with cycling compared to heterotrophic cultivation. Next, the model was incorporated into open-loop and closed-loop control systems and compared with traditional fed-batch systems. Closed-loop systems which incorporated a feed-optimizing algorithm increased biomass yield on glucose more than twofold compared to standard fed-batch cultures for cycling cultures. Finally, the performance was compared to conventional proportional-integral-derivative (PID) controllers. Both simulation and experimental results exhibited superior performance for genome-scale model process control (GMPC) compared to traditional PID systems, reducing the overall measured value and setpoint error by 80% over 8 h. Overall, this approach provides researchers with the capability to enhance nutrient utilization and productivity of cell factories systematically by combining genome-scale models and controllers into an integrated platform with superior performance to conventional fed-batch and PID methodologies.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a Clear Fiber Cherenkov Counter

We have developed a new PID detector consists of clear fibers. PID efficiency was measured with 470 MeV e{sup +} beam. As a result, this detector with thickness of 5 cm has the PID efficiency of 95 %. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗