Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE ERROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A fast multi-fidelity method with uncertainty quantification for complex data correlations: Application to vortex-induced vibrations of marine risers

Here we develop a fast multi-fidelity modeling method for very complex correlations between high- and low-fidelity data by working in modal space to extract the proper correlation function. We apply this method to infer the amplitude of motion of a flexible marine riser in cross-flow, subject to vortex-induced vibrations (VIV). VIV are driven by an absolute instability in the flow, which imposes a frequency (Strouhal) law that requires a matching with the impedance of the structure; this matching is easily achieved because of the rapid parametric variation of the added mass force. As a result, the wavenumber of the riser spatial response is within narrow bands of uncertainty. Hence, an error in wavenumber prediction can cause significant phase-related errors in the shape of the amplitude of response along the riser, rendering correlation between low- and high-fidelity data very complex. Working in modal space as outlined herein, dense data from low-fidelity data, provided by the semi-empirical computer code VIVA, can correlate in modal space with few high-fidelity data, obtained from experiments or fully-resolved CFD simulations, to correct both phase and amplitude and provide predictions that agree very well overall with the correct shape of the amplitude response. We also quantify the uncertainty in the prediction using Bayesian modeling and exploit this uncertainty to formulate an active learning strategy for the best possible location of the sensors providing the high fidelity measurements.

42 ENGINEERING↗

A Deep Learning Approach for In-Network Synchrophasor Missing Data Recovery Using Programmable Network Switches

Phasor measurement unit (PMU) networks deliver accurate and timely measurements, which is essential for managing today’s electric power systems. To ensure data quality and enhance the cyber-resilience of PMU networks against malicious attacks and data errors, this study presents an online PMU missing data recovery scheme by leveraging P4 programmable switches. The data plane incorporates a customized PMU protocol parser that abstracts the necessary payload data for recovery. Recovery processes are executed in the control plane using a pre-trained machine learning model. Both traditional and advanced ML models, such as transformer and TimeGPT, are explicitly employed for data prediction. This approach ensures rapid and precise data recovery. Performance evaluations focus on recovery speed and accuracy, using a real dataset from a campus microgrid. With 20% missing PMU data, the mean absolute percentage error for voltage magnitude is 0.0384%, and the phase angle error discrepancy is approximately 0.4064%.

Phasor Measurement Unit, Machine Learning, Program↗

A Method to Automate the Segmentation of the GTV and ITV for Lung Tumors

Four-dimensional computed tomography (4D-CT) is a useful tool in the treatment of tumors that undergo significant motion. To fully utilize 4D-CT motion information in the treatment of mobile tumors such as lung cancer, autosegmentation methods will need to be developed. Using autosegmentation tools in the Pinnacle{sup 3} v8.1t treatment planning system, 6 anonymized 4D-CT data sets were contoured. Two test indices were developed that can be used to evaluate which autosegmentation tools to apply to a given gross tumor volume (GTV) region of interest (ROI). The 4D-CT data sets had various phase binning error levels ranging from 3% to 29%. The appropriate autosegmentation method (rigid translational image registration and deformable surface mesh) was determined to properly delineate the GTV in all of the 4D-CT phases for the 4D-CT data sets with binning errors of up to 15%. The ITV was defined by 2 methods: a mask of the GTV in all 4D-CT phases and the maximum intensity projection. The differences in centroid position and volume were compared with manual segmentation studies in literature. The indices developed in this study, along with the autosegmentation tools in the treatment planning system, were able to automatically segment the GTV in the four 4D-CTs with phase binning errors of up to 15%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Environment-assisted error correction of single-qubit phase damping

Open quantum system dynamics of random unitary type may in principle be fully undone. Closely following the scheme of environment-assisted error correction proposed by Gregoratti and Werner [J. Mod. Opt. 50, 915 (2003)], we explicitly carry out all steps needed to invert a phase-damping error on a single qubit. Furthermore, we extend the scheme to a mixed-state environment. Surprisingly, we find cases for which the uncorrected state is closer to the desired state than any of the corrected ones.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AMiBA: cluster Sunyaev-Zel'dovich effect observations with the expanded 13-element array

The Yuan-Tseh Lee Array for Microwave Background Anisotropy (AMiBA) is a co-planar interferometer array operating at a wavelength of 3 mm to measure the Sunyaev–Zel’dovich effect (SZE) of galaxy clusters at arcminute scales. The first phase of operation—with a compact 7-element array with 0.6 m antennas (AMiBA-7)—observed six clusters at angular scales from 5{sup ′} to 23{sup ′}. Here, we describe the expansion of AMiBA to a 13-element array with 1.2 m antennas (AMiBA-13), its subsequent commissioning, and cluster SZE observing program. The most noticeable changes compared to AMiBA-7 are (1) array re-configuration with baselines ranging from 1.4 m to 4.8 m, allowing us to sample structures between 2{sup ′} and 10{sup ′}, (2) 13 new lightweight carbon-fiber-reinforced plastic (CFRP) 1.2 m reflectors, and (3) additional correlators and six new receivers. Since the reflectors are co-mounted on and distributed over the entire six-meter CFRP platform, a refined hexapod pointing error model and phase error correction scheme have been developed for AMiBA-13. These effects—entirely negligible for the earlier central close-packed AMiBA-7 configuration—can lead to additional geometrical delays during observations. Our correction scheme recovers at least 80 ± 5% of the point-source fluxes. We, therefore, apply an upward correcting factor of 1.25 to our visibilities to correct for phase decoherence, and a ±5% systematic uncertainty is added in quadrature with our statistical errors. We demonstrate the absence of further systematics with a noise level consistent with zero in stacked uv-visibilities. From the AMiBA-13 SZE observing program, we present here maps of a subset of 12 clusters with signal-to-noise ratios above five. We demonstrate combining AMiBA-7 with AMiBA-13 observations on Abell 1689, by jointly fitting their data to a generalized Navarro–Frenk–White model. Our cylindrically integrated Compton-y values for five radii are consistent with results from the Berkeley-Illinois-Maryland Array, the Owens Valley Radio Observatory, the Sunyaev–Zel’dovich Array, and the Planck Observatory. We also report the first targeted SZE detection toward the optically selected cluster RCS J1447+0828, and we demonstrate the ability of AMiBA SZE data to serve as a proxy for the total cluster mass. Finally, we show that our AMiBA-SZE derived cluster masses are consistent with recent lensing mass measurements in the literature.

79 ASTRONOMY AND ASTROPHYSICS↗

M-ary-state phase-shift-keying discrimination below the homodyne limit

We investigate a strategy for M-ary discrimination of nonorthogonal phase states with error rates below the homodyne limit. This strategy uses feed forward to update a reference field and signal nulling for the state discrimination. We experimentally analyze the receiver performance using postprocessing and a Bayesian strategy to emulate the feed-forward process. This analysis shows that for a moderate system detection efficiency, it is possible to surpass the homodyne error limit for quadrature phase-shift keying signals using feed forward.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dosimetric Implications of Residual Tracking Errors During Robotic SBRT of Liver Metastases

Purpose: Although the metric precision of robotic stereotactic body radiation therapy in the presence of breathing motion is widely known, we investigated the dosimetric implications of breathing phase–related residual tracking errors. Methods and Materials: In 24 patients (28 liver metastases) treated with the CyberKnife, we recorded the residual correlation, prediction, and rotational tracking errors from 90 fractions and binned them into 10 breathing phases. The average breathing phase errors were used to shift and rotate the clinical tumor volume (CTV) and planning target volume (PTV) for each phase to calculate a pseudo 4-dimensional error dose distribution for comparison with the original planned dose distribution. Results: The median systematic directional correlation, prediction, and absolute aggregate rotation errors were 0.3 mm (range, 0.1-1.3 mm), 0.01 mm (range, 0.00-0.05 mm), and 1.5° (range, 0.4°-2.7°), respectively. Dosimetrically, 44%, 81%, and 92% of all voxels differed by less than 1%, 3%, and 5% of the planned local dose, respectively. The median coverage reduction for the PTV was 1.1% (range in coverage difference, −7.8% to +0.8%), significantly depending on correlation (P=.026) and rotational (P=.005) error. With a 3-mm PTV margin, the median coverage change for the CTV was 0.0% (range, −1.0% to +5.4%), not significantly depending on any investigated parameter. In 42% of patients, the 3-mm margin did not fully compensate for the residual tracking errors, resulting in a CTV coverage reduction of 0.1% to 1.0%. Conclusions: For liver tumors treated with robotic stereotactic body radiation therapy, a safety margin of 3 mm is not always sufficient to cover all residual tracking errors. Dosimetrically, this translates into only small CTV coverage reductions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PLATFORM DEFORMATION PHASE CORRECTION FOR THE AMiBA-13 COPLANAR INTERFEROMETER

We present a new way to solve the platform deformation problem of coplanar interferometers. The platform of a coplanar interferometer can be deformed due to driving forces and gravity. A deformed platform will induce extra components into the geometric delay of each baseline and change the phases of observed visibilities. The reconstructed images will also be diluted due to the errors of the phases. The platform deformations of The Yuan-Tseh Lee Array for Microwave Background Anisotropy (AMiBA) were modeled based on photogrammetry data with about 20 mount pointing positions. We then used the differential optical pointing error between two optical telescopes to fit the model parameters in the entire horizontal coordinate space. With the platform deformation model, we can predict the errors of the geometric phase delays due to platform deformation with a given azimuth and elevation of the targets and calibrators. After correcting the phases of the radio point sources in the AMiBA interferometric data, we recover 50%-70% flux loss due to phase errors. This allows us to restore more than 90% of a source flux. The method outlined in this work is not only applicable to the correction of deformation for other coplanar telescopes but also to single-dish telescopes with deformation problems. This work also forms the basis of the upcoming science results of AMiBA-13.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Error field measurements with rotating RMP fields for DIII-D H-mode

3D magnetic sensors are employed to identify the amplitude and toroidal phase of error fields (EF) by analyzing the torque balance for magnetic islands entrained by rotating resonant magnetic perturbations (RMPs) in DIII-D H-mode plasmas. This technique of torque balance allows for efficient error field identification, offering a valuable tool for scenario-specific and optimized error field compensation (EFC) and requires only magnetic diagnostics. The torque balance used in this work includes the contribution from electromagnetic torque due to error fields, wall response, RMP fields, and viscous. Results show that viscous torque plays a crucial role, particularly during locked modes and H-mode plasmas, ensuring accurate data fits with lower residuals. The torque balance technique reveals that the L- and H-mode plasmas have distinct EF configurations, and consistent with a model-based EF analysis including MHD response in IPEC and the SURFMN EF simulation. This technique shows great robustness in measuring the intrinsic EF amplitude regardless of its amplitude or toroidal phase. Repeated discharges with EFC disparities exhibit consistent results of intrinsic error field within a reasonable range near the “standard” error field compensation. Additionally, the use of a rotating n = 1 resonant magnetic perturbation offers the advantage of reducing disruption risks by entraining saturated magnetic islands. These findings are instrumental for optimizing EF correction in fusion devices, thereby enhancing tearing mode suppression and overall plasma stability.

3D magnetic sensors↗

Measurement Accuracy Limitation Analysis on Synchrophasors

This paper analyzes the theoretical accuracy limitation of synchrophasors measurements on phase angle and frequency of the power grid. Factors that cause the measurement error are analyzed, including error sources in the instruments and in the power grid signal. Different scenarios of these factors are evaluated according to the normal operation status of power grid measurement. Based on the evaluation and simulation, the errors of phase angle and frequency caused by each factor are calculated and discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Why is Boris algorithm so good?

Due to its excellent long term accuracy, the Boris algorithm is the de facto standard for advancing a charged particle. Despite its popularity, up to now there has been no convincing explanation why the Boris algorithm has this advantageous feature. In this paper, we provide an answer to this question. We show that the Boris algorithm conserves phase space volume, even though it is not symplectic. The global bound on energy error typically associated with symplectic algorithms still holds for the Boris algorithm, making it an effective algorithm for the multi-scale dynamics of plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interferometric adaptive optics for high power laser pointing, wave-front control and phasing

Implementing the capability to perform fast ignition experiments, as well as, radiography experiments on the National Ignition Facility (NIF) places stringent requirements on the control of each of the beam's pointing and overall wavefront quality. One quad of the NIF beams, 4 beam pairs, will be utilized for these experiments and hydrodynamic and particle-in-cell simulations indicate that for the fast ignition experiments, these beams will be required to deliver 50% (4.0 kJ) of their total energy (7.96 kJ) within a 40 {micro}m diameter spot at the end of a fast ignition cone target. This requirement implies a stringent pointing and overall phase conjugation error budget on the adaptive optics system used to correct these beam lines. The overall encircled energy requirement is more readily met by phasing of the beams in pairs but still requires high Strehl ratios, Sr, and rms tip/tilt errors of approximately one {micro}rad. To accomplish this task we have designed an interferometric adaptive optics system capable of beam pointing, high Strehl ratio and beam phasing with a single pixilated MEMS deformable mirror and interferometric wave-front sensor. We present the design of a testbed used to evaluate the performance of this wave-front sensor below along with simulations of its expected performance level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of Nanosilicates on Poly(vinylidene fluoride) Crystal Polymorphism: Part 1. Melt-crystallization at High Supercooling

Polymorphism of poly(vinylidene fluoride), PVDF, in the presence of Lucentite STN organically modified silicate (OMS) is investigated for PVDF nanocomposites melt-crystallized at high supercooling temperatures where neat PVDF crystallizes exclusively in the alpha crystalline phase. Nanocomposites were prepared from solution with 0-1.0 wt% OMS composition. Here we observed that clay addition promotes gamma phase formation in nanocomposites melt-crystallized at high supercooling (i.e., at low crystallization temperature), whereas previously we showed that even small amount of nanosilicates resulted in beta phase formation in cold-crystallized PVDF nanocomposites. Wide-angle X-ray scattering (WAXS), Fourier transform infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC) studies showed that {alpha}- and {gamma}-phases co-existed in nanocomposites containing up to 0.1 wt% OMS, and the amount of {alpha}-crystals substantially diminished for higher OMS content. Formation of {gamma}-crystal phase was confirmed with morphologic observation of spherulites of low-birefringence using polarizing optical and atomic force microscopies, and their crystalline structures were verified by FTIR and Raman microscopic spectroscopy. We also address in this work the ambiguities in assessing PVDF crystallographic phases, and correct the phase identification errors which have persisted up to this point in the literature based on melting point confusion. The crystal phase identification for PVDF nanocomposites is discussed and clarified, based on X-ray scattering, vibrational spectra, and thermal analysis. For reference, we provide a vibrational band list, indicating the close, or overlapping bands, of the three phases of PVDF: {alpha}, {beta} and {gamma}.

36 MATERIALS SCIENCE↗

Note: An improved calibration system with phase correction for electronic transformers with digital output

The existing electronic transformer calibration systems employing data acquisition cards cannot satisfy some practical applications, because the calibration systems have phase measurement errors when they work in the mode of receiving external synchronization signals. This paper proposes an improved calibration system scheme with phase correction to improve the phase measurement accuracy. We employ NI PCI-4474 to design a calibration system, and the system has the potential to receive external synchronization signals and reach extremely high accuracy classes. Accuracy verification has been carried out in the China Electric Power Research Institute, and results demonstrate that the system surpasses the accuracy class 0.05. Furthermore, this system has been used to test the harmonics measurement accuracy of all-fiber optical current transformers. In the same process, we have used an existing calibration system, and a comparison of the test results is presented. The system after improvement is suitable for the intended applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Practical solutions for reliable triple probe measurements in magnetized plasmas

The triple probe method to obtain local, time-resolved measurements of density, electron temperature and plasma potential is investigated in detail. The difficulties in obtaining reliable measurements with this technique are discussed and overcome. These include phase delay errors, ion sheath expansion and limited bandwidth due to stray capacitance to ground. In particular, a relatively simple electronic circuit is described to strongly reduce stray capacitance. Measurements with the triple probe are presented in a plasma characterized by interchange-driven turbulence in the TORPEX device. The measured time-averaged and time-dependent, conditionally averaged parameters are cross-checked with other Langmuir probe based techniques, and show good agreement. Triple probe measurements show that electron temperature fluctuations are sufficiently large, such that the identification of plasma potential fluctuations with fluctuations of the floating potential is not a good approximation. Over a large radial region, the time-averaged fluctuation-induced particle flux can, however, be deduced from floating potential only. This is because the phase shift between density and electron temperature is close to zero there and temperature fluctuations do not give rise to a net radial particle transport.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Invited Review Article: Measurement uncertainty of linear phase-stepping algorithms

Phase retrieval techniques are widely used in optics, imaging and electronics. Originating in signal theory, they were introduced to interferometry around 1970. Over the years, many robust phase-stepping techniques have been developed that minimize specific experimental influence quantities such as phase step errors or higher harmonic components of the signal. However, optimizing a technique for a specific influence quantity can compromise its performance with regard to others. We present a consistent quantitative analysis of phase measurement uncertainty for the generalized linear phase stepping algorithm with nominally equal phase stepping angles thereby reviewing and generalizing several results that have been reported in literature. All influence quantities are treated on equal footing, and correlations between them are described in a consistent way. For the special case of classical N-bucket algorithms, we present analytical formulae that describe the combined variance as a function of the phase angle values. For the general Arctan algorithms, we derive expressions for the measurement uncertainty averaged over the full 2{pi}-range of phase angles. We also give an upper bound for the measurement uncertainty which can be expressed as being proportional to an algorithm specific factor. Tabular compilations help the reader to quickly assess the uncertainties that are involved with his or her technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interference versus success probability in quantum algorithms with imperfections

We study the importance of interference for the performance of Shor's factoring algorithm and Grover's search algorithm using a recently proposed interference measure. To this aim we introduce systematic unitary errors, random unitary errors, and decoherence processes in these algorithms. We show that unitary errors which destroy the interference destroy the efficiency of the algorithm, too. However, unitary errors may also create useless additional interference. In such a case the total amount of interference can increase, while the efficiency of the quantum computation decreases. For decoherence due to phase flip errors, interference is destroyed for small error probabilities, and converted into destructive interference for error probabilities approaching 1, leading to success probabilities which can even drop below the classical value. Our results show that in general, interference is necessary in order for a quantum algorithm to outperform classical computation, but large amounts of interference are not sufficient and can even lead to destructive interference with worse than classical success rates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A staggered-grid finite-difference scheme optimized in the time–space domain for modeling scalar-wave propagation in geophysical problems

For modeling scalar-wave propagation in geophysical problems using finite-difference schemes, optimizing the coefficients of the finite-difference operators can reduce numerical dispersion. Most optimized finite-difference schemes for modeling seismic-wave propagation suppress only spatial but not temporal dispersion errors. We develop a novel optimized finite-difference scheme for numerical scalar-wave modeling to control dispersion errors not only in space but also in time. Our optimized scheme is based on a new stencil that contains a few more grid points than the standard stencil. We design an objective function for minimizing relative errors of phase velocities of waves propagating in all directions within a given range of wavenumbers. Dispersion analysis and numerical examples demonstrate that our optimized finite-difference scheme is computationally up to 2.5 times faster than the optimized schemes using the standard stencil to achieve the similar modeling accuracy for a given 2D or 3D problem. Compared with the high-order finite-difference scheme using the same new stencil, our optimized scheme reduces 50 percent of the computational cost to achieve the similar modeling accuracy. This new optimized finite-difference scheme is particularly useful for large-scale 3D scalar-wave modeling and inversion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗