SU-F-T-376: The Efficiency of Calculating Photonuclear Reaction On High-Energy Photon Therapy by Monte Carlo Method

Purpose: Secondary-neutrons having harmful influences to a human body are generated by photonuclear reaction on high-energy photon therapy. Their characteristics are not known in detail since the calculation to evaluate them takes very long time. PHITS(Particle and Heavy Ion Transport code System) Monte Carlo code since versions 2.80 has the new parameter “pnimul” raising the probability of occurring photonuclear reaction forcibly to make the efficiency of calculation. We investigated the optimum value of “pnimul” on high-energy photon therapy. Methods: The geometry of accelerator head based on the specification of a Varian Clinac 21EX was used for PHITS ver. 2.80. The phantom (30 cm * 30 cm * 30 cm) filled the composition defined by ICRU(International Commission on Radiation Units) was placed at source-surface distance 100 cm. We calculated the neutron energy spectra in the surface of ICRU phantom with “pnimal” setting 1, 10, 100, 1000, 10000 and compared the total calculation time and the behavior of photon using PDD(Percentage Depth Dose) and OCR(Off-Center Ratio). Next, the cutoff energy of photon, electron and positron were investigated for the calculation efficiency with 4, 5, 6 and 7 MeV. Results: The calculation total time until the errors of neutron fluence become within 1% decreased as increasing “pnimul”. PDD and OCR showed no differences by the parameter. The calculation time setting the cutoff energy like 4, 5, 6 and 7 MeV decreased as increasing the cutoff energy. However, the errors of photon become within 1% did not decrease by the cutoff energy. Conclusion: The optimum values of “pnimul” and the cutoff energy were investigated on high-energy photon therapy. It is suggest that using the optimum “pnimul” makes the calculation efficiency. The study of the cutoff energy need more investigation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-491: Photon Beam Matching Analysis at Multiple Sites Up to Twelve Years Post Installation

Purpose: To determine if the photon beams associated with several models of accelerators are matched with ‘Golden Beam’ data (VGBD) to assess treatment planning modeling and delivery. Methods: Six accelerators’ photon beams were evaluated to determine if they matched the manufacturer’s (Varian Medical Systems, Inc.) VGBD. Additional direct comparisons of the 6X and 18X beams using the manufacturer’s specification of Basic and Fine beam matching were also performed. The Cseries accelerator models were 21 EX (3), IX (2), and a IX Trilogy, ranging from three to twelve years post installation. Computerized beam scanning was performed (IBA Blue Phantom 2) with 2 CC13 ion chambers in water at 100 cm SSD. Dmax (10 cm2 field size), percentage depth dose (6 cm2, 10 cm2, 20 cm2, and 30 cm2 field sizes) and beam uniformity (10 cm2, 30 cm2 and 40 cm2 field sizes) were evaluated. Results: When comparing the beams with VGBD using the ‘Basic’ matching criteria, all beams were within the specifications ( 1.5mm at dmax, 1% PDD, and 2% Profiles). When considering the “Fine” matching criteria ( 1.5mm at dmax, 0.5% PDD, and 2% Profiles), only three of six 6MV beams and two of six high energy (five 18MV & one 15MV) beams passed. Direct comparisons between accelerators using the Clinac IX (installed 2012) as the reference beam datasets resulted in all 6 MV and 18MV beams meeting both the “Basic” and “Fine” criterion with the exception of two accelerators. Conclusion: Linear accelerators installed up to nine years apart are capable of meeting the manufacturers beam matching criteria for “Basic” matching. Without any adjustments most beams, when evaluated, may meet the “Fine” match criteria. The use of a single dataset (VGBD or designated accelerator reference data) for treatment planning commissioning is acceptable and can provide quality treatment delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-574: MLC Based SRS Beam Commissioning - Minimum Target Size Investigation

Purpose: To implement a MLC accelerator based SRS program using small fields down to 1 cm × 1 cm and to determine the smallest target size safe for clinical treatment. Methods: Computerized beam scanning was performed in water using a diode detector and a linac-head attached transmission ion chamber to characterize the small field dosimetric aspects of a 6 MV photon beam (Trilogy-Varian Medical Systems, Inc.). The output factors, PDD and profiles of field sizes 1, 2, 3, 4, and 10 cm{sup 2} were measured and utilized to create a new treatment planning system (TPS) model (AAA ver 11021). Static MLC SRS treatment plans were created and delivered to a homogeneous phantom (Cube 20, CIRS, Inc.) for a 1.0 cm and 1.5 cm “PTV” target. A 12 field DMLC plan was created for a 2.1 cm target. Radiochromic film (EBT3, Ashland Inc.) was used to measure the planar dose in the axial, coronal and sagittal planes. A micro ion chamber (0.007 cc) was used to measure the dose at isocenter for each treatment delivery. Results: The new TPS model was validated by using a tolerance criteria of 2% dose and 2 mm distance to agreement. For fields ≤ 3 cm{sup 2}, the max PDD, Profile and OF difference was 0.9%, 2%/2mm and 1.4% respectively. The measured radiochromic film planar dose distributions had gamma scores of 95.3% or higher using a 3%/2mm criteria. Ion chamber measurements for all 3 test plans effectively met our goal of delivering the dose accurately to within 5% when compared to the expected dose reported by the TPS (1 cm plan Δ= −5.2%, 1.5 cm plan Δ= −2.0%, 2 cm plan Δ= 1.5%). Conclusion: End to end testing confirmed that MLC defined SRS for target sizes ≥ 1.0 cm can be safely planned and delivered.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-582: Small Field Dosimetry in Radiosurgery Collimators with a Stealth Chamber

Purpose: The extraction of a reference signal for measuring small fields in scanning mode can be problematic. In this work we describe the use of a transmission chamber in small field dosimetry for radiosurgery collimators and compare TMR curves obtained with stereotactic diode and microionization chamber. Methods: Four radiosurgery cones of diameters 5, 10, 12.5, and 15mm supplied by Elekta Medical were commissioned in a 6MV FFF beam from an Elekta Versa linac. A transmission chamber manufactured by IBA (Stealth chamber) was attached to the lower part of the collimators and used for PDD and profile measurements in scanning mode with a Scanditronix stereotactic diode. It was also used for centering the stereotactic diode in the water tank to measure TMR and output factors, by integrating the signal. TMR measurements for all collimators and the OF for the largest collimator were also acquired on a polystyrene PTW 29672 phantom with a PTW PinPoint 3D chamber 0.016 cm3 volume. Results: Measured TMR with diode and microionization chamber agreed very well with differences larger than 1% only for depths above 15cm, except the smaller collimator, for which differences were always smaller than 2%. Calculated TMR were significantly different (up to 7%) from measured TMR. The differences are attributed to the change in response of the diode with depth, because the effective field aperture varies with depth. Furthermore, neglecting the ratio of phantom-scatter factors in the conversion formula also contributes to this difference. OF measured with diode and chamber showed a difference of 3.5%. Conclusion: The transmission chamber overcomes the problem of extracting a reference signal and is of great help for small field commissioning. Calculating TMR from PDD is strongly discouraged. Good agreement was found when comparing measurements of TMR with stereotactic diode in water with measurements with microionization chamber in polystyrene.

60 APPLIED LIFE SCIENCES↗

SU-G-201-12: Investigation of Beta-Emitter 90Sr-90Y Dose Distribution Using Gafchromic EBT3 Film for Application On Conformal Skin Brachytherapy Device

Purpose: To investigate {sup 90}Sr-{sup 90}Y as a high dose rate (HDR) source for application in a conformal skin brachytherapy (CSBT) device. The CSBT device has been previously developed to provide patient specific treatment for small inoperable lesions and irregular surfaces. Methods: A popular beta emitter, {sup 90}Sr-{sup 90}Y was tested for feasibility in a CSBT device. A 1 cm diameter plaque was used to deliver dose to a solid water phantom containing EBT3 Gafchromic films arranged at the surface and perpendicular to it. Additionally, a 1 cm diameter 6 MeV electron beam was used to irradiate EBT3 film at 100 cm SSD with a 0.5 cm bolus. Films were digitized with an Epson Expression 10000 XL scanner and calibrated with a 6 MeV electron specific dose curve. Normalized percent depth doses (PDD) and dose profiles for both techniques were analyzed using ImageJ. Results: Dose distributions achieved with the {sup 90}Sr-{sup 90}Y sources were compared with those of external electron beam radiation therapy (EBRT). Penumbra (20%- 80%) for EBRT and 90Sr-90Y were 4.3 mm and 1.6 mm, respectively. PDD values of 50% (normalized to 2 mm) were 10.1 mm and 2.8 mm for electron and {sup 90}Sr-{sup 90}Y, respectively. Flatness (80% of the central beam profile) was 14.1% at a 5 mm depth for EBRT and 4.0% at surface for the {sup 90}Sr-{sup 90}Y. Conclusion: As expected, the PDDs of {sup 90}Sr-{sup 90}Y in water are shallower than that of external electron beams for the same field size. {sup 90}Sr-{sup 90}Y can be used in CSBT to provide patient specific treatment where shallower depth doses than that provided by electron external beams may be required: e.g. eyelids, nose, lips, ears, etc. The customizability of EBRT could be replicated by using multiple adjacent {sup 90}Sr-{sup 90}Y plaque placements.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-AB-BRC-05: Creation of a Monte Carlo TrueBeam Model by Reproducing Varian Phase Space Data

Purpose: To create a Varian TrueBeam 6 MV FFF Monte Carlo model using BEAMnrc/EGSnrc that accurately reproduces the Varian representative dataset, followed by tuning the model’s source parameters to accurately reproduce in-house measurements. Methods: A BEAMnrc TrueBeam model for 6 MV FFF has been created by modifying a validated 6 MV Varian CL21EX model. Geometric dimensions and materials were adjusted in a trial and error approach to match the fluence and spectra of TrueBeam phase spaces output by the Varian VirtuaLinac. Once the model’s phase space matched Varian’s counterpart using the default source parameters, it was validated to match 10 × 10 cm{sup 2} Varian representative data obtained with the IBA CC13. The source parameters were then tuned to match in-house 5 × 5 cm{sup 2} PTW microDiamond measurements. All dose to water simulations included detector models to include the effects of volume averaging and the non-water equivalence of the chamber materials, allowing for more accurate source parameter selection. Results: The Varian phase space spectra and fluence were matched with excellent agreement. The in-house model’s PDD agreement with CC13 TrueBeam representative data was within 0.9% local percent difference beyond the first 3 mm. Profile agreement at 10 cm depth was within 0.9% local percent difference and 1.3 mm distance-to-agreement in the central axis and penumbra regions, respectively. Once the source parameters were tuned, PDD agreement with microDiamond measurements was within 0.9% local percent difference beyond 2 mm. The microDiamond profile agreement at 10 cm depth was within 0.6% local percent difference and 0.4 mm distance-to-agreement in the central axis and penumbra regions, respectively. Conclusion: An accurate in-house Monte Carlo model of the Varian TrueBeam was achieved independently of the Varian phase space solution and was tuned to in-house measurements. KO acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290).

60 APPLIED LIFE SCIENCES↗

TU-H-BRC-08: Use and Validation of Flexible 3D Printed Tissue Compensators for Post-Mastectomy Radiation Therapy

Purpose: Patient-specific tissue equivalent compensators can be used for post-mastectomy radiation therapy (PMRT) to achieve homogenous dose distributions with single-field treatments. However, current fabrication methods are time consuming and expensive. 3D-printing technology could overcome these limitations. The purposes of this study were to [1] evaluate materials for 3D-printed compensators [2] design and print a compensator to achieve a uniform thickness to a clinical target volume (CTV), and [3] demonstrate that a single-field electron compensator plan is a clinically feasible treatment option for PMRT. Methods: Blocks were printed with three materials; print accuracy, density, Hounsfield units (HU), and percent depth doses (PDD) were evaluated. For a CT scan of an anthropomorphic phantom, we used a ray-tracing method to design a compensator that achieved uniform thickness from compensator surface to CTV. The compensator was printed with flexible tissue equivalent material whose physical and radiological properties were most similar to soft tissue. A single-field electron compensator plan was designed and compared with two standard-of-care techniques. The compensator plan was validated with thermoluminescent dosimeter (TLD) measurements. Results: We identified an appropriate material for 3D-printed compensators that had high print accuracy (99.6%) and was similar to soft tissue; density was 1.04, HU was - 45 ± 43, and PDD curves agreed with clinical curves within 3 mm. We designed and printed a compensator that conformed well to the phantom surface and created a uniform thickness to the CTV. In-house fabrication was simple and inexpensive (<$75). Compared with the two standard plans, the compensator plan resulted in overall more homogeneous dose distributions and performed similarly in terms of lung/heart doses and 90% isodose coverage of the CTV. TLD measurements agreed well with planned doses (within 5 %). Conclusions: We have demonstrated that 3D-printed compensators make single-field electron therapy a clinically feasible treatment option for PMRT.

60 APPLIED LIFE SCIENCES↗

The dataset of in-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations (2024R1)

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found on the AGAGE home page: https://agage.mit.edu/instruments.Data from the AGAGE and affiliated stations (total of 10 sites) between August 1993 and June 2023 are provided in “Agage_gcmd_gcms_data_2024_07_11.tar.gz” (compressed tar file). The metadata file has information on each station and currently released species. The standard scales used in archived species are listed in "AGAGE_scale_2024_v1.pdf". Additional information can be found on the AGAGE website (https://agage.mit.edu).Update: Dec. 4, 20241. The Cape Grim H2_PDD data are updated in this release ((H2_PDD values in previous release are wrong due to coding error). All other data in this release are the same as previous version ("Agage_gcmd_gcms.data.2024_07_11.tar.gz")2. The latest data are saved in "Agage_gcmd_gcms.data.2024_12_04.tar.gz"

54 ENVIRONMENTAL SCIENCES↗

Superconductivity in the palladium-hydrogen system

Band theory and phonon measurements are used to calculate the electron-phonon coupling constant wavelength for Pd and PdD. The results indicate that superconductivity is absent in Pd metal because of the large value of the Coulomb pseudopotential, and that superconductivity occurs in PdD primarily because of coupling with the optic phonons. These results are consistent with superconducting transition-temperature measurements for these systems.

Papaconstantopoulos, D. A.↗

Probability density distribution of velocity differences at high Reynolds numbers

Recent understanding of fine-scale turbulence structure in high Reynolds number flows is mostly based on Kolmogorov's original and revised models. The main finding of these models is that intrinsic characteristics of fine-scale fluctuations are universal ones at high Reynolds numbers, i.e., the functional behavior of any small-scale parameter is the same in all flows if the Reynolds number is high enough. The only large-scale quantity that directly affects small-scale fluctuations is the energy flux through a cascade. In dynamical equilibrium between large- and small-scale motions, this flux is equal to the mean rate of energy dissipation epsilon. The pdd of velocity difference is a very important characteristic for both the basic understanding of fully developed turbulence and engineering problems. Hence, it is important to test the findings: (1) the functional behavior of the tails of the probability density distribution (pdd) represented by P(delta(u)) is proportional to exp(-b(r) absolute value of delta(u)/sigma(sub delta(u))) and (2) the logarithmic decrement b(r) scales as b(r) is proportional to r(sup 0.15) when separation r lies in the inertial subrange in high Reynolds number laboratory shear flows.

Praskovsky, Alexander A.↗

LANL C10.2 Projects in FY13

LANL has two projects in C10.2: Defect-Induced Mix Experiment (DIME) (ongoing, several runs at Omega; NIF shots this summer); and Shock/Shear (tested at Omega for two years; NIF shots in second half of FY13). Each project is jointly funded by C10.2, other C10 MTEs, and Science Campaigns. DIME is investigating 4{pi} and feature-induced mix in spherically convergent ICF implosions by using imaging of the mix layer. DIME prepared for NIF by demonstrating its PDD mix platform on Omega including imaging mid-Z doped layers and defects. DIME in FY13 will focus on PDD symmetry-dependent mix and moving burn into the mix region for validation of mix/burn models. Re-Shock and Shear are two laser-driven experiments designed to study the turbulent mixing of materials. In FY-2012 43 shear and re-shock experimental shots were executed on the OMEGA laser and a complete time history obtained for both. The FY-2013 goal is to transition the experiment to NIF where the larger scale will provide a longer time period for mix layer growth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Amorphous fluorinated copolymer gas separation membranes

Membranes having a permselective active layer of a copolymerized perfluorinated monomer and an non-fluorinated alkylvinylester monomer demonstrate superior selective permeability performance for separating gas mixtures compared to membranes of exclusively perfluorinated polymers. Preferred active layer compositions are copolymers of perfluoro-2,2-dimethyl-1,3 dioxole (PDD) copolymerized with an alkylvinyl ester such as vinyl acetate, and vinyl pivalate, and with alkylvinyl esters that are substantially hydrolyzed to provide copolymerized vinyl alcohol functionality. The membranes can have a thin, high diffusion rate, “gutter layer” of a fluorinated polymer highly permeable to nitrogen positioned between the active layer and a porous support layer. A novel copolymer effective in selectively permeable membranes is a copolymer of PDD and an alkylvinyl ester compound having the formula H2C═CHOC(O)R1 in which R1 is a linear or branched alkyl group of from 2 to 5 carbon atoms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parallel beamlet dose calculation via beamlet contexts in a distributed multi‐GPU framework

Purpose Dose calculation is one of the most computationally intensive, yet essential tasks in the treatment planning process. With the recent interest in automatic beam orientation and arc trajectory optimization techniques, there is a great need for more efficient model‐based dose calculation algorithms that can accommodate hundreds to thousands of beam candidates at once. Foundational work has shown the translation of dose calculation algorithms to graphical processing units ( GPU s), lending to remarkable gains in processing efficiency. But these methods provide parallelization of dose for only a single beamlet, serializing the calculation of multiple beamlets and under‐utilizing the potential of modern GPU s. In this paper, the authors propose a framework enabling parallel computation of many beamlet doses using a novel beamlet context transformation and further embed this approach in a scalable network of multi‐ GPU computational nodes. Methods The proposed context‐based transformation separates beamlet‐local density and TERMA into distinct beamlet contexts that independently provide sufficient data for beamlet dose calculation. Beamlet contexts are arranged in a composite context array with dosimetric isolation, and the context array is subjected to a GPU collapsed‐cone convolution superposition procedure, producing the set of beamlet‐specific dose distributions in a single pass. Dose from each context is converted to a sparse representation for efficient storage and retrieval during treatment plan optimization. The context radius is a new parameter permitting flexibility between the speed and fidelity of the dose calculation process. A distributed manager‐worker architecture is constructed around the context‐based GPU dose calculation approach supporting an arbitrary number of worker nodes and resident GPU s. Phantom experiments were executed to verify the accuracy of the context‐based approach compared to Monte Carlo and a reference CPU ‐ CCCS implementation for single beamlets and broad beams composed by addition of beamlets. Dose for representative 4 π beam sets was calculated in lung and prostate cases to compare its efficiency with that of an existing beamlet‐sequential GPU ‐ CCCS implementation. Code profiling was also performed to evaluate the scalability of the framework across many networked GPU s. Results The dosimetric accuracy of the context‐based method displays <1.35% and 2.35% average error from the existing serialized CPU ‐ CCCS algorithm and Monte Carlo simulation for beamlet‐specific PDD s in water and slab phantoms, respectively. The context‐based method demonstrates substantial speedup of up to two orders of magnitude over the beamlet‐sequential GPU ‐ CCCS method in the tested configurations. The context‐based framework demonstrates near linear scaling in the number of distributed compute nodes and GPU s employed, indicating that it is flexible enough to meet the performance requirements of most users by simply increasing the hardware utilization. Conclusions The context‐based approach demonstrates a new expectation of performance for beamlet‐based dose calculation methods. This approach has been successful in accelerating the dose calculation process for very large‐scale treatment planning problems ‐ such as automatic 4 π IMRT beam orientation and VMAT arc trajectory selection, with hundreds of thousands of beamlets ‐ in clinically feasible timeframes. The flexibility of this framework makes it as a strong candidate for use in a variety of other very large‐scale treatment planning tasks and clinical workflows.

Neph, Ryan↗

Investigation of modification of hydrogenation and structural properties of LaNi{sub 5} intermetallic compound induced by substitution of Ni by Pd

The hydrogenation properties of the LaNi{sub 5} (CaCu{sub 5} type, hP6, P6/mmm) and Pd substituted derivatives LaNi{sub 5-x}Pd{sub x} compounds have been studied in the whole homogeneity range of the solid solution (0.25{<=}x{<=}1.5). The pressure versus hydrogen content isotherms show several plateaus and an increase of the plateau pressure as a function of palladium concentration. The volume increase of the Pd substituted alloys should have resulted in a lowering, and not an increase, of the plateau pressure, according to the conventional models based on the size effect. In order to elucidate the origin of this anomalous behavior, both an experimental and a theoretical ab initio electronic structure investigation have been carried out. Experimentally, the nature and the structural properties of the hydrides have been studied by both in situ and ex situ neutron diffraction. The crystal structures of the three hydride phases are reported (LaNi{sub 3.5}Pd{sub 1.5}D{sub 1.96}, filled-up CaCu{sub 5} type, P6/mmm; LaNi{sub 4}PdD{sub 2.72}, LaNi{sub 2}(Ni{sub 0.75}Pt{sub 0.25}){sub 3}H{sub 2.61} type, oI128, Ibam; LaNi{sub 4.75}Pd{sub 0.25}D{sub 5.67}, partly ordered CaCu{sub 5} type, P6mm). In addition, the phase diagram of LaNi{sub 5-x}Pd{sub x}-H system has been investigated. The electronic and thermodynamic properties of both intermetallic compounds and the hydrides have been studied by ab initio electronic structure calculations. The theoretical results are in good agreement with our experimental data, and show that electronic interactions play a major role in the hydrogenation behavior of these Pd substituted intermetallic compounds, and that these effects cannot be accounted for by a simplistic model based on the size effect alone. -- Graphical abstract: Phase diagram of the system LaNi{sub 5-x}Pd{sub x}-D{sub 2} (absorption) at 25 {sup o}C and 25 bar. Display Omitted

36 MATERIALS SCIENCE↗

Dosimetry of Small Circular Fields for 6-MeV Electron Beams

Small field electron beams used in the clinic present complex dosimetry. This investigation reports dosimetric characteristics of small 6-MeV electron field measurements and Monte Carlo calculations, and examines their impact on patient dosimetry. Radiographic film and ionization chamber were used for dosimetric measurements for a 6-MeV electron beam from a Varian 21EX linac. A set of circular cerrobend cutouts with diameters ranging from 2 to 3.0 cm was made. A clinical Monte Carlo algorithm was used to calculate dosimetric parameters. As the cutout diameter decreased, the build-up portion of the percentage depth dose (PDD) curves shifted toward the phantom surface, the depth of maximum dose, d{sub max,} decreased from 1.2 cm to 0.6 cm, but the practical range, R{sub p}, remained constant at about 3.1 cm. The absorbed dose rate, D{sub r}, decreased linearly with decreasing diameter. Profile coverage ratios CR (ie, the ratio of a given isodose line to the cutout diameter) at d{sub max}, for 90% and 80%, CR{sub 90}, CR{sub 80}, are approximately 55% and 73%, respectively. As the cutout diameter decreased, the 90% to 10% penumbra to diameter ratio, PR, increased from 0.49 to 0.56 for 3- to 2-cm cutouts. The total 90% to 10% penumbra was about the same size as the cutout diameter. The measured output factors were in good agreement with Monte Carlo calculation within 2.2%. Accurate small electron field measurements were performed using parallel plate ion chamber and film. The data were well supported by Monte Carlo calculations. These data facilitate routine clinical treatments for small cutouts as d{sub max}, D{sub r}, and other data can be quickly obtained instead of performing labor-intensive individual patient measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Commissioning a Miniature Multileaf Collimator for Small Field Radiotherapy

The aim of this study was to determine dosimetric data for the Siemens ModuLeaf miniature multileaf collimator. Acquiring accurate data for small fields requires careful evaluation of different measurement techniques and dosimeters. Output factors were measured using several different detectors. Comparing these results demonstrated the relative under-response of the devices as the field size approaches the active area of the detector. Measurements obtained with a diamond detector, radiographic film, 0.125 cm{sup 3} cylindrical and advanced Markus ionization chambers agreed (within 0.7%) down to a field size of 2 x 2 cm. For smaller field sizes, only the diamond detector and the film agreed within their relative uncertainties. Head scatter factors were measured in brass and Perspex miniphantoms using the cylindrical chamber positioned at the isocenter, and in the Perspex miniphantom at extended distances. For field sizes of less than 3 x 3 cm, only the measurements with the brass miniphantom at the isocenter and the Perspex miniphantom at extended distances agreed (within 0.8%). The effect on the miniphantom measurements of using a low scatter support stand was also quantified. Beam profiles were measured using radiographic film. An unexpected artifact was found in these images because of increased backscatter from white lines inscribed and painted on the phantom. Percentage depth doses (PDDs) measured with and without the ModuLeaf attached agreed for all field sizes down to 3 x 3 cm. Below this field size, tissue maximum ratios (TMRs) were measured using an advanced Markus chamber. The 3 x 3 cm ModuLeaf TMR data agreed with the non-ModuLeaf PDD data within their relative uncertainties. This study investigated the use of several different measurement methods from which accurate dosimetric parameters can be obtained without the need to acquire specialist detectors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Commissioning of small field size radiosurgery cones in a 6-MV flattening filter-free beam

This study aimed to describe the commissioning of small field size radiosurgery cones in a 6-MV flattening filter free (FFF) beam and report our measured values. Four radiosurgery cones of diameters 5, 10, 12.5, and 15 mm supplied by Elekta Medical were commissioned in a 6-MV FFF beam from an Elekta Versa linear accelerator. The extraction of a reference signal for measuring small fields in scanning mode is challenging. A transmission chamber was attached to the lower part of the collimators and used for percentage depth dose (PDD) and profile measurements in scanning mode with a stereotactic diode. Tissue-maximum ratios (TMR) and output factors (OF) for all collimators were measured with a stereotactic diode (IBA). TMR and the OF for the largest collimator were also acquired on a polystyrene phantom with a microionization chamber of 0.016 cm{sup 3} volume (PTW Freiburg PinPoint 3D). Measured TMR with diode and PinPoint microionization chamber agreed very well with differences smaller than 1% for depths below 20 cm, except for the smaller collimator, for which differences were always smaller than 2%. Calculated TMR were significantly different (up to 7%) from measured TMR. OF measured with diode and chamber showed a difference of 3.5%. The use of a transmission chamber allowed the measurement of the small-field dosimetric properties with a simple setup. The commissioning of radiosurgery cones in FFF beams has been performed with essentially the same procedures and recommended detectors used with flattened beams. Good agreement was found between TMR measurements acquired with the IBA stereotactic diode and the PinPoint 3D microionization chamber. The transmission chamber overcomes the problem of extracting a reference signal and is of great help for small-field commissioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The financial attractiveness assessment of large waste management projects registered as clean development mechanism

Highlights: • Projects are not financially attractive without registration as CDMs. • WM benchmarks and indicators are converging and reducing in variance. • A sensitivity analysis reveal that revenue has more of an effect on the financial results. • Results indicate that an extensive database would reduce WM project risk and capital costs. • Disclosure standards would make information more comparable worldwide. - Abstract: This study illustrates the financial analyses for demonstration and assessment of additionality presented in the project design (PDD) and enclosed documents of the 431 large Clean Development Mechanisms (CDM) classified as the ‘waste handling and disposal sector’ (13) over the past ten years (2004–2014). The expected certified emissions reductions (CER) of these projects total 63.54 million metric tons of CO{sub 2}eq, where eight countries account for 311 projects and 43.36 million metric tons. All of the projects declare themselves ‘not financially attractive’ without CER with an estimated sum of negative results of approximately a half billion US$. The results indicate that WM benchmarks and indicators are converging and reducing in variance, and the sensitivity analysis reveals that revenues have a greater effect on the financial results. This work concludes that an extensive financial database with simple standards for disclosure would greatly diminish statement problems and make information more comparable, reducing the risk and capital costs of WM projects.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗