Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Toward Human-Centric Transportation and Energy Metrics: Influence of Mode, Vehicle Occupancy, Trip Distance, and Fuel Economy

Traditional metrics measuring transportation and energy outcomes can be augmented to better represent impacts on people's lives and systems-level performance. In this context, this study introduces two novel metrics: road capacity (as number of people traveling and accessing services) and energy intensity (as energy use for people traveling and accessing services). Current national-level distributions of available data in the United States for factors contributing to the two new integrated metrics are used as context to evaluate potential outcomes. These factors include vehicle occupancy, mode share, fuel economy, and trip distance. Variations in input values provide insights on how these factors shape efficiencies in road capacity and energy intensity. Parametric sensitivity analysis indicates that the impact of each input depends upon the metric being evaluated. For the human-centered road capacity mobility metric, increasing vehicle occupancy has the largest effect – twice that of increasing mode share for bike, walk, and transit. For the energy intensity mobility metric, the effect of improving fuel economy is the largest. However, when the focus is on accessibility (instead of mobility), for both metrics the effect of lowering average trip distance is the largest. Additionally, a novel interactive tool to visualize the results for various parameter combinations makes the metrics practitioner ready. The findings suggest that the diffusion of new human-centric metrics that benchmark outcomes associated with road capacity and energy may be significant in motivating new sustainable transportation investments and efficient utilization of infrastructure, mobility assets, and services.

ADVANCED PROPULSION SYSTEMS↗

Clean Energy Employment Impacts and Occupational Analyses: Building Envelope & Electrification Upgrades

Under the Communities LEAP (Local Energy Action Program) Pilot, the U.S. Department of Energy (DOE) is working with a group of LEAP communities to bolster workforce development initiatives and support the growth of local employment in the clean energy economy. Through this resource, DOE seeks to provide participating communities with an overview of the types of occupations that could be affected by investments in building envelope and building electrification upgrades in existing building stock - differentiating between the residential and commercial sectors. This occupational analysis is intended to be used by communities to inform workforce initiatives (e.g., local training and education programs) as they implement building energy efficiency and electrification projects at scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing Occupant Light Exposure in Factory and Office Spaces

There is an increasing desire to provide healthy workplace environments that better serve people while minimizing the impact on the planet. Building recommendations help designers to incorporate the latest research and best practices, but translating research studies conducted in different settings to broader recommendations is challenging. This is particularly true for lighting, with researchers continuing to learn more about circadian, neuroendocrine, and neurobehavioral responses to light. The recommendations are regularly adjusting to incorporate the latest research as well as feedback from practitioners implementing these recommendations. There remains a need to better document the actual light exposure that people experience over the course of a day and across seasons, so that researchers can better understand the influence of light on people and recommendations can be refined. Thankfully, advances in sensor technology are making this more possible than ever. PNNL collaborated with ETC Inc. to understand actual occupant light exposure in factory and office spaces at ETC’s Headquarters in Middleton, WI. The primary building at ETC headquarters opened in 2004 and houses approximately 800 employees that contribute to central business functions, customer support, research and development, as well as the company’s primary 60,000 ft2 manufacturing facility. Vertical light exposure measurements including electric light and daylight were recorded in factory, research and development, and office work areas at occupant eye height. This document will focus on lighting measurements collected in six factory and office locations across work location, season, and time of day. Ultimately, detailed lighting measurements can be coupled with employee surveys to support development of satisfactory work environments.

42 ENGINEERING↗

Using Maximum Circular Velocity in Halo Occupation Distribution Models to Predict Galaxy Clustering

Abstract Standard halo occupation distribution (HOD) models predict how galaxies occupy halos based on a single property, the virial mass, M vir . To incorporate galaxy assembly bias, we consider alternative halo mass proxies to use in the HOD. A promising replacement is maximum circular velocity, V max , which measures the halo’s potential well, and successfully predicts galaxy clustering in subhalo abundance matching models. We fit galaxy clustering measurements from SDSS DR7 with two modified HODs besides the standard M vir -based model: one where V max is used as the halo property that determines galaxy occupation, and the other adopting an adjustable combination of M vir and V max . Except for the reduced volume M r < − 20 threshold sample fit with V max alone, neither change improves the model performance in predicting the projected two-point correlation function, w p . We conclude that switching the primary variable to V max does not significantly improve the HOD model’s ability to fit galaxy clustering.

Mezini, Lorena↗

Modeling Occupant Core Temperatures Across the Boston Building Stock to Advance Public Health

In recent history, extreme heat has been the cause of most deaths from a natural disaster. Exposure to extreme heat can aggravate preexisting conditions, increase hospitalization, and even cause death. Thus, modeling the thermal resilience of households across the United States will allow for a quantitative assessment of the health and safety risks posed by extreme heat. For the first time, we simulate occupant comfort in representative households across Boston by combining the granular results of the ResStock(TM) model with a two-node heat strain model. This model calculates occupants' core body temperature in each simulated household over a year. We compare the simulated core temperatures to two public health metrics: hyperthermia and heat stroke. Our results show for households in Boston that do not have or use aid conditioning, thousands potentially experience many dangerous heat events each summer and these events can last for more than a day at a time. These heat events peak during the late afternoon and evening, just as residents are coming home, cooking meals, and trying to go to sleep. We have found that multi-family buildings, renters, and low-income homes in more airtight and insulated homes are the most at risk for these events. These results demonstrate the scale and urgency of exposure to extreme heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System and method for occupancy-driven register airflow control

An HVAC register airflow control system and an air flow control method are provided. A housing of the system is in fluid communication with an air source for supplying an airflow. The housing includes an air outlet to the enclosed space. A detection sensor detects occupancy information of the enclosed space. A controller generates a control signal based on the occupancy information and controls the shape change of a damper made of a shape memory material. The damper is controlled to switch between a first operative configuration for preventing the airflow from entering the enclosed space and a second operative configured for permitting the airflow to enter the enclosed space.

Wang, Ya↗

CFD-trained ANN Model for Approximating Near-occupant Condition in Real-time Simulations

The main drawback of Computational Fluid Dynamics (CFD) simulations has been the time and resource consuming nature which is not suitable for real-time applications. In this work, we first generated numerous CFD models of a given indoor space to obtain airspeed, temperature, and mean radiant temperature near an occupant as training data. Several artificial neural networks (ANN) models were trained using this CFD simulated data to approximate near real-time environmental conditions for a given occupant. This trained ANN model approach is a part of a real-time simulation of building operations using a combination of software and real hardware (HVAC equipment) approaches. The preliminary results suggest that the CFD- generated training data and the trained ANN model can accurately approximate such conditions in a real-time application, a method that has great potential in building simulation and building digital twin areas of research.

Zhang, Yun↗

Plug Load Management Through Occupant Engagement at Washington State University

To decrease costs and improve building occupant safety, Washington State University (WSU) began planning a plug load management campaign in 2020, with implementation beginning in 2021. This case study describes the campaign's goals, approach, and results over the past 5 years, ultimately showing that occupant- and behavior-focused strategies can meaningfully reduce plug load energy use while improving health and safety.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Factors linked to participant attrition in a longitudinal occupational health surveillance program

For occupational medical screening programs focused on long-term health surveillance, participant attrition is a significant barrier to success. Here we investigate demographic, medical history, and clinical data from National Supplemental Screening Program (NSSP) examinees for association with likelihood of return for a second exam (rescreening). A total of 15,733 individuals completed at least one NSSP exam before December 31, 2016; of those, 4832 also completed a second exam on or before December 31, 2019. Stepwise logistic regression models were used to identify variables associated with whether a participant was rescreened in the NSSP. Individuals were less likely to return for rescreening if they had a history of any cancer; cardiovascular problems; diabetes or kidney disease; or if they used insulin. Age at time of first exam and job site category significantly influenced likelihood of return. Workers categorized as “guests” were more likely to return. Participants were less likely to return if they had an abnormal urinalysis, abnormal pulmonary function, pneumoconiosis, aortic atherosclerosis, or hearing loss at their initial exam. Participants who received a chest X-ray at their initial screening were more likely to return. The presence of health problems is strongly linked to screening program attrition. Participants who are older at the time of their initial screening exam are less likely to return. The discovery of several strong demographic, medical, and job associations reveals the importance for medical screening programs to understand and address factors that influence participant retention and, consequently, the effectiveness of long-term health surveillance activities.

60 APPLIED LIFE SCIENCES↗

3d-Orbital Occupancy Regulated Ir-Co Atomic Pair Toward Superior Bifunctional Oxygen Electrocatalysis

Atomically dispersed metal catalysts are hailed as the most promising catalyst category for oxygen electrocatalysis. However, the challenges in regulating electronic configuration and unveiling the mechanism on the atomic scale are hindering their practical implementation. Herein, we modulate the Co d-orbital electron configuration by constructing the Ir–Co atomic pair toward boosted bifunctional activity. The as-developed dual-atom IrCo–N–C catalyst displays unprecedented activity with a half-wave potential of 0.911 V for oxygen reduction reaction and only 330 mV overpotential at 10 mA cm –2 for oxygen evolution reaction, outperforming the single-atom counterparts as well as the commercial Pt/C and Ir/C benchmarks. The impressive bifunctionality is also verified in a Zn–air battery prototype with an ultra-high cyclability over 450 cycles. Furthermore, theoretical calculations are performed to shed light on the synergetic effects of the atomic pair site, where the incorporation of Ir atom alters the d-orbital energy level of Co and thus induces the re-arrangement of d-electron toward intensified spin polarization. As a result, the lower occupancy of d z 2 orbital facilitates the electron acceptation from oxygen to form a stronger Co–O σ bond, thereby propelling faster reaction kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Occupational Contamination with a Highly Enriched Uranium Solution

This medical case report describes the first reported instance of occupational skin contamination with a uranyl nitrate solution containing highly enriched uranium. The report provides an overview of the unique medical treatment and management considerations in such a case. Herein, internal dose assessment is covered in detail. The discussion covers key points regarding uranium characteristics, chemical and radiological damage to body tissues from HEU exposure, and resources available for assistance with a case of radiological contamination. This information adds to the limited medical literature on this topic and provides a valuable reference for medical personnel when dealing with this uncommon problem.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Evaluation of the Reliability of Passive Infrared (PIR) Occupancy Sensors for Residential Indoor Lighting

Solid-state lighting (SSL) technologies have penetrated the general illumination market in recent years, largely replacing conventional technologies such as incandescent and fluorescent lighting. Most of the initial excitement about light-emitting diode (LED) sources for SSL devices focused on their energy savings potential resulting from vast improvements in source efficiency and luminous efficacy compared with conventional illumination products. More recently, the focus has shifted toward other aspects of lighting application efficiency, namely intensity effectiveness and spectral efficiency, because of the ease of controlling both the light intensity of LEDs with drive voltage and the color properties of the LED-based illuminators. To capitalize on the energy savings of increased intensity effectiveness and spectral efficiency, a lighting control system (LCS) is often used. While the current penetration of LCSs is relatively modest, it is anticipated that lighting controls (i.e., connected lighting, controls and LED and conventional lighting) could have an installed penetration as higher as 46% by the year 2035, saving an additional 1.3 quads of energy. Despite the large energy savings that can be gained from using LCSs, standard test methods for evaluating sensors employed in LCSs and reliability data of the LCSs and their components are generally lacking. The National Electrical Manufacturers Association (NEMA) developed the only standard, NEMA WD 7-2011 (R2016), to test occupancy and motion sensor performance (herein referred to as “the NEMA protocol”). In a previous U.S. Department of Energy (DOE) effort, some concerns of the NEMA protocol were identified (e.g., strict height and weight limits on test subjects, large amounts of manual effort, sometimes inconsistent repeatability). During the current work, a consistent detection length test (DLT) and a Robotic Sensor Evaluation System (RoboSES) were developed to alleviate some of these concerns. RoboSES acts as a human surrogate by using thermal pads on a mannequin and a remote-controlled mobile base to test a sensor’s field of view (FOV). This report builds on the earlier DOE efforts to understand sensor technologies used in LCSs for general illumination. Specifically, this report describes the optimization of RoboSES, characterizes and establishes test methods to assess the reliability of multiple passive infrared (PIR) sensors, and reports the findings of robustness and reliability testing on two commercial PIR sensors intended for residential applications. The information presented in this report is gained from up to 4,000 hours (hrs) of accelerated stress tests (ASTs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Unbalanced Battle in Excellence: Revealing Effect of Ni/Co Occupancy on Water Splitting and Oxygen Reduction Reactions in Triple–Conducting Oxides for Protonic Ceramic Electrochemical Cells

Porous electrodes that conduct electrons, protons, and oxygen ions with dramatically expanded catalytic active sites can replace conventional electrodes with sluggish kinetics in protonic ceramic electrochemical cells. In this work, a strategy is utilized to promote triple conduction by facilitating proton conduction in praseodymium cobaltite perovskite through engineering non-equivalent B-site Ni/Co occupancy. Surface infrared spectroscopy is used to study the dehydration behavior, which proves the existence of protons in the perovskite lattice. The proton mobility and proton stability are investigated by hydrogen/deuterium (H/D) isotope exchange and temperature-programmed desorption. It is observed that the increased nickel replacement on the B-site has a positive impact on proton defect stability, catalytic activity, and electrochemical performance. This doping strategy is demonstrated to be a promising pathway to increase catalytic activity toward the oxygen reduction and water splitting reactions. The chosen PrNi 0.7 Co 0.3 O 3–δ oxygen electrode demonstrates excellent full-cell performance with high electrolysis current density of –1.48 A cm –2 at 1.3 V and a peak fuel-cell power density of 0.95 W cm –2 at 600 °C and also enables lower-temperature operations down to 350 °C, and superior long-term durability.

08 HYDROGEN↗

Full Detector Simulation with Unprecedented Background Occupancy at a Muon Collider

In recent years, a Muon collider has attracted a lot of interest in the high-energy physics community, thanks to its ability of achieving clean interaction signatures at multi-TeV collision energies in the most cost-effective way. Estimation of the physics potential of such an experiment must take into account the impact of beam-induced background on the detector performance, which has to be carefully evaluated using full detector simulation. Tracing of all the background particles entering the detector region in a single bunch crossing is out of reach for any realistic computing facility due to the unprecedented number of such particles. To make it feasible a number of optimisations have been applied to the detector simulation workflow. This contribution presents an overview of the main characteristics of the beam-induced background at a Muon collider, the detector technologies considered for the experiment and how they are taken into account to strongly reduce the number of irrelevant computations performed during the detector simulation. Special attention is dedicated to the optimisation of track reconstruction with the conformal tracking algorithm in this high-occupancy environment, which is the most computationally demanding part of event reconstruction.

97 MATHEMATICS AND COMPUTING↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗

Pu 5f Occupation in Plutonium Dioxide

Herein an actinide N 4,5 branching ratio analysis of PuO 2 and UO 2 has been performed, including measurements with a scanning transmission electron microscope at the Advanced Light Source. It is shown that the 5f occupation of the Pu in plutonium dioxide is n = 5. This is contrary to recent results from another technique.

36 MATERIALS SCIENCE↗

Actinide 5f Occupations: The Case of PuO 2

In actinide chemistry, the formal number of open-shell 5f electrons, n open , is a well-defined quantity with an integer value. The effective 5f occupation, n f , additionally takes donation and back-donation into account, generally has a non-integer value, and has varying numerical definitions. The present study explores the important distinction between n f and n open in actinide chemistry with the example of PuO2, by using electronic structure methods with a relativistic Hamiltonian in combination with experimental Pu M 5 -edge high-energy-resolution X-ray absorption and emission spectroscopic data. The total donation to the metal in PuO 2 is between 3.1 and 2.4 electrons, depending on the type of calculation, most of which is to the Pu 6d and 5f shells. The donation into 5f is sensitive to the approximations in the electronic structure model but likely amounts to 1.6/0.8 electrons when the diffuse regions of the 5f shell are included/excluded. Valence band resonant inelastic X-ray scattering experiments demonstrate that Pu 5f electron density is present in the valence band; thus, there is a clear experimental signature of covalent bonding in PuO 2 . Pu M 5 -edge and M 3 -edge high-energy-resolution X-ray absorption near-edge structures for Pu 3+ and Pu 4+ in an aqueous solution are compared to PuO 2 , showing that Pu in PuO 2 has an nf closer to Pu 4+ (aq).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Absence of Y-pocket in 1-Fe Brillouin zone and reversed orbital occupation imbalance in FeSe

The FeSe nematic phase has been the focus of recent research on iron-based superconductors (IBSs) due to its unusual properties, which are distinct from those of the pnictides. A series of theoretical/experimental studies were performed to determine the origin of the nematic phase. However, they yielded conflicting results and caused additional controversies. Here, we report the results of angle-resolved photoemission and X-ray absorption spectroscopy studies on FeSe detwinned by a piezo stack. We fully resolved band dispersions with orbital characters near the Brillouin zone (BZ) corner, and revealed an absence of any Fermi pocket at the Y point in the 1-Fe BZ. In addition, the occupation imbalance between d xz and d yz orbitals was the opposite of that of iron pnictides, consistent with the identified band characters. These results resolve issues associated with the FeSe nematic phase and shed light on the origin of the nematic phase in IBSs.

36 MATERIALS SCIENCE↗