Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OMEGA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

FY10 LLNL OMEGA Experimental Programs

In FY10, LLNL conducted several campaigns on the OMEGA laser system and on the EP laser system, as well as campaigns that used the OMEGA and EP beams jointly. Overall LLNL led 301 target shots involving the OMEGA laser system and 96 target shots involving the EP laser system. Approximately 40% of the total number of shots (137 OMEGA shots, 32 EP shots) shots supported the National Ignition Campaign (NIC). The remainder was dedicated to experiments for High-Energy-Density Physics (HED) (164 OMEGA shots, 64 EP shots).

42 ENGINEERING↗

Measurement of the muon anomalous precession frequency $\omega_a$ in the Fermilab $g-2$ experiment

The Fermilab Muon $g-2$ Experiment was designed to measure the muon's anomalous magnetic moment $a_{\mu} = (g-2)/2$ to 140 parts per billion. The value of $a_{\mu}$ is proportional to the difference frequency $\omega_a=\omega_s-\omega_c$ between the muon's cyclotron frequency and spin precession frequency in the uniform magnetic field of the $g-2$ storage ring. The frequency $\omega_a$ is extracted from the time distribution of the mu-decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. We will discuss the various approaches to the frequency determination including the reconstruction, fitting of time distributions, and procedures for handling the effects of gain changes, positron pileup and beam dynamics. We also discuss the data consistency checks and the strategy for the averaging of $\omega_a$ across the different analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Clock synchronization experiments using OMEGA transmissions

The OMEGA transmissions from North Dakota on 13.10 and 12.85 kHz were monitored at several sites using a recently developed OMEGA timing receiver specifically designed for this purpose. The experiments were conducted at Goddard Space Flight Center, Greenbelt, Maryland; U.S. Naval Observatory, Washington, D.C.; and at the NASA tracking station, Rosman, North Carolina. Results show that cycle identification of the two carrier frequencies was made at each test site, thus, coarse time (76 microseconds) from the OMEGA transmitted signals to within the ambiguity period of each OMEGA frequency was extracted. The fine time determination, which was extracted from the phase difference between the received OMEGA signals and locally generated signals, was about + or - 2 microseconds for daytime reception and about + or - 5 microseconds for nighttime reception.

Chi, A. R.↗

Flight test and evaluation of Omega navigation in a general aviation aircraft. Volume 1: Technical

A low cost flight research program was conducted to evaluate the performance of differential Omega navigation in a general aviation aircraft. The flight program consisted of two distinct parts corresponding to the two major objectives of the study. The Wallops Flight Program was conducted to obtain Omega signal and phase data in the Wallops Flight Center vicinity to provide preliminary technical information and experience in preparation for a comprehensive NASA/FAA flight test program of an experimental differential Omega system. The Northeast Corridor Flight Program was conducted to examine Omega operational suitability and performance on low altitude area navigation (RNAV) routes for city-center to city-center VTOL commercial operations in the Boston-New York-Washington corridor. The development, execution and conclusions of the flight research program are discribed. The results of the study provide both quantitative and qualitative data on the Omega Navigation System under actual operating conditions.

Howell, J. D.↗

Simulation analysis of a microcomputer-based, low-cost Omega navigation system

The current status of research on a proposed micro-computer-based, low-cost Omega Navigation System (ONS) is described. The design approach emphasizes minimum hardware, maximum software, and the use of a low-cost, commercially-available microcomputer. Currently under investigation is the implementation of a low-cost navigation processor and its interface with an omega sensor to complete the hardware-based ONS. Sensor processor functions are simulated to determine how many of the sensor processor functions can be handled by innovative software. An input data base of live Omega ground and flight test data was created. The Omega sensor and microcomputer interface modules used to collect the data are functionally described. Automatic synchronization to the Omega transmission pattern is described as an example of the algorithms developed using this data base.

Lilley, R. W.↗

Does lower Omega allow a resolution of the large-scale structure problem?

The intermediate angular scale anisotropy of the cosmic microwave background, peculiar velocities, density correlations, and mass fluctuations for both neutrino and baryon-dominated universes with Omega less than one are evaluated. The large coherence length associated with a low-Omega, hot dark matter-dominated universe provides substantial density fluctuations on scales up to 100 Mpc: there is a range of acceptable models that are capable of producing large voids and superclusters of galaxies and the clustering of galaxy clusters, with Omega roughly 0.3, without violating any observational constraint. Low-Omega, cold dark matter-dominated cosmologies are also examined. All of these models may be reconciled with the inflationary requirement of a flat universe by introducing a cosmological constant 1-Omega.

Silk, Joseph↗

The faint X-ray sources in and out of omega Centauri: X-ray observations and optical identifications

We present the results of an observation of the globular cluster omega Cen (NGC 5139) with the Einstein high-resolution imager (HRI). Of the five low-luminosity X-ray sources toward omega Cen which were first identified with the Einstein imaging proportional counter (IPC) (Hertz and Grindlay 1983a, b), two are detected in the Einstein HRI observation: IPC sources A and D. These detections provide source positions accurate to 3 sec-4 sec; the positions are confirmed in a ROSAT HRI observation reported here. Using CCD photometry and spectroscopy, we have identified both sources as foreground dwarf M stars with emission lines (dMe). The chance projection of two Mde stars within approximately 13 min of the center of omega Cen is not extraordinary, given the space density of these stellar coronal X-ray sources. We discuss the possible nature of the three as yet unidentified IPC sources toward omega Cen, and consider the constraints that the Einstein observations place on the total population of X-ray sources in this cluster. The integrated luminosity from faint X-ray sources in omega Cen appears to be low relative to both the old open cluster M67 and the post-core-collapse globular, NGC 6397.

Cool, Adrienne M.↗

Observational limits on Omega in stars, brown dwarfs, and stellar remnants from gravitational microlensing

Microlensing by compact objects with masses between approximately 0.001 solar masses and approximately 300 solar masses will amplify the continuum emission of a quasar, without significantly changing its line emission. Thus, compact objects with masses associated with stars, subdwarfs, and stellar remnants will reduce the apparent equivalent widths of quasar emission lines. It is possible to detect this population of lenses by searching for an increase in the number of small equivalent width quasars with redshift. This increase was looked for, but not found, in quasar samples taken from the Einstein Medium Sensitivity Survey and the Steidel & Sargent absorption-line studies. Thus, Omega(sub c), the cosmological density of compact objects relative to the critical density, is less than or approximately equal to 0.1 in the mass range 0.01 solar masses-20 solar masses (for Omega less than 0.6). For any value of Omega, Omega(sub c) less than or approximately equal to 0.2 in the larger mass range 0.001 solar masses-60 solar masses, and Omega(sub c) less than 1 for 0.001 solar masses-300 solar masses. Subdwarfs, stellar objects, or their remnants (e.g., MACHOS) cannot close the universe.

Dalcanton, Julianne J.↗

Offshore Membrane Enclosures for Growing Algae (OMEGA: A System for Biofuel Production, Wastewater Treatment, and CO2 Sequestration

We are developing Offshore Membrane Enclosures for Growing Algae (OMEGA). OMEGAs are closed photo-bioreactors constructed of flexible, inexpensive, and durable plastic with small sections of semi-permeable membranes for gas exchange and forward osmosis (FO). Each OMEGA modules is filled with municipal wastewater and provided with CO2 from coastal CO2 sources. The OMEGA modules float just below the surface, and the surrounding seawater provides structural support, temperature control, and mixing for the freshwater algae cultures inside. The salinit7 gradient from inside to outside drives forward osmosis through the patches of FO membranes. This concentrates nutrients in the wastewater, which enhances algal growth, and slowly dewaters the algae, which facilitates harvesting. Thy concentrated algal biomass is harvested for producing biofuels and fertilizer. OMEGA system cleans the wastewater released into the surrounding coastal waters and functions as a carbon sequestration system.

Trent, Jonathan↗

Offshore Membrane Enclosure for Growing Algai (Omega) System for Biofuel Production, Wastewater Treatment, and CO2 Sequestration

We are developing Offshore Membrane Enclosures for Growing Algae (OMEGA). OMEGAs are closed photo-bioreactors constructed of flexible, inexpensive, and durable plastic with small sections of semi-permeable membranes for gas exchange and forward osmosis (FO). Each OMEGA modules is filled with municipal wastewater and provided with CO2 from coastal CO2 sources. The OMEGA modules float just below the surface, and the surrounding seawater provides structural support, temperature control, and mixing for the freshwater algae cultures inside. The salinity gradient from inside to outside drives forward osmosis through the patches of FO membranes. This concentrates nutrients in the wastewater, which enhances algal growth, and slowly dewaters the algae, which facilitates harvesting. The concentrated algal biomass is harvested for producing biofuels and fertilizer. OMEGA system cleans the wastewater released into the surrounding coastal waters and functions as a carbon sequestration system.

Trent, Jonathan↗

Pressure-induced alpha to omega transition in titanium metal: a systematic study of the effects of uniaxial stress

The effects of uniaxial stress on the pressure-induced {alpha} {yields} {omega} transition in pure titanium (Ti) are investigated by means of angle dispersive X-ray diffraction in a diamond-anvil cell. Experiments under four different pressure environments reveal that: (1) the onset of the transition depends on the pressure medium used, going from 4.9 GPa (no pressure medium) to 10.5 GPa (argon pressure medium); (2) the {alpha} and {omega} phases coexist over a rather large pressure range, which depends on the pressure medium employed; (3) the hysteresis and quenchability of the {omega} phase is affected by differences in the sample pressure environment; and (4) a short-term laser heating of Ti lowers the {alpha} {yields} {omega} transition pressure. Possible transition mechanisms are discussed in the light of the present results, which clearly demonstrate the influence of uniaxial stress in the {alpha} {yields} {omega} transition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MULTI-KEV X-RAY YIELDS FROM HIGH-Z GAS TARGETS FIELDED AT OMEGA

The authors report on modeling of x-ray yield from gas-filled targets shot at the OMEGA laser facility. The OMEGA targets were 1.8 mm long, 1.95 mm in diameter Be cans filled with either a 50:50 Ar:Xe mixture, pure Ar, pure Kr or pure Xe at {approx} 1 atm. The OMEGA experiments heated the gas with 20 kJ of 3{omega} ({approx} 350 nm) laser energy delivered in a 1 ns square pulse. the emitted x-ray flux was monitored with the x-ray diode based DANTE instruments in the sub-keV range. Two-dimensional x-ray images (for energies 3-5 keV) of the targets were recorded with gated x-ray detectors. The x-ray spectra were recorded with the HENWAY crystal spectrometer at OMEGA. Predictions are 2D r-z cylindrical with DCA NLTE atomic physics. Models generally: (1) underpredict the Xe L-shell yields; (2) overpredict the Ar K-shell yields; (3) correctly predict the Xe thermal yields; and (4) greatly underpredict the Ar thermal yields. However, there are spreads within the data, e.g. the DMX Ar K-shell yields are correctly predicted. The predicted thermal yields show strong angular dependence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Density-Dependent Properties of Hadronic Matter in the self-consistent Chiral ({sigma},{pi},{omega}) Mean-Field Model

Density-dependent relations among saturation properties of symmetric nuclear matter and properties of hadronic stars are discussed by applying the conserving chiral nonlinear ({sigma},{pi},{omega}) hadronic mean-field theory. The chiral nonlinear ({sigma},{pi},{omega}) mean-field theory is an extension of the conserving nonlinear (nonchiral) {sigma}-{omega} hadronic mean-field theory which is thermodynamically consistent, relativistic and is a Lorentz-covariant mean-field theory of hadrons. In the extended chiral ({sigma},{pi},{omega}) mean-field model, all the masses of hadrons are produced by the breaking of chiral symmetry, which is different from other conventional chiral partner models. By comparing both nonchiral and chiral mean-field approximations, the effects of the chiral symmetry breaking mechanism on the mass of {sigma}-meson, coefficients of nonlinear interactions and Fermi-liquid properties are investigated in nuclear matter and neutron stars.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence for a scalar meson resonance in the {pi}{sup -}p{yields}n{omega}{phi} reaction

The charge-exchange reaction {pi}{sup -}p{yields}n{omega}(780){phi}(1020) is studied with the VES setup. The ({omega}{phi}) system is observed at relatively low background. Its invariant mass distribution peaks near threshold. The two-particles partial wave analyses shows that the J{sup pc} = 0{sup ++} state dominates. This wave is compared with 0{sup ++} component in the ({omega}{omega}) system at the comparable mass, which was measured earlier.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extended Chiral ({sigma},{pi},{omega}) Mean-Field Model with Vacuum Fluctuation Corrections

Density-dependent relations among saturation properties of symmetric nuclear matter and properties of hadronic stars are discussed by applying the conserving chiral nonlinear ({sigma},{pi},{omega}) mean-field theory. The chiral nonlinear ({sigma},{pi},{omega}) mean-field theory is an extension of the conserving nonlinear (nonchiral){sigma}-{omega} mean-field theory, which is thermodynamically consistent, relativistic and Lorentz-covariant. In the extended chiral ({sigma},{pi},{omega}) mean-field model, all the masses of hadrons are produced by the spontaneous chiral symmetry breaking, which is different from conventional chiral partner models. By comparing both nonchiral and chiral mean-field approximations, the effects of the chiral symmetry breaking mechanism on the mass of {sigma}-meson, coefficients of nonlinear interactions and Fermi-liquid properties are investigated in nuclear matter and neutron stars.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Three-omega thermal-conductivity measurements with curved heater geometries

The three-omega method, a powerful technique to measure the thermal conductivity of nanometer-thick films and the interfaces between them, has historically employed straight conductive wires to act as both heaters and thermometers. When investigating stochastically prepared samples such as two-dimensional materials and nanomembranes, residue and excess material can make it difficult to fit the required millimeter-long straight wire on the sample surface. There are currently no available criteria for how diverting three-omega heater wires around obstacles affects the validity of the thermal measurement. In this Letter, we quantify the effect of the wire curvature by performing three-omega experiments with a wide range of frequencies using both curved and straight heater geometries on SiO 2 /Si samples. When the heating wire is curved, we find that the measured Si substrate thermal conductivity changes by only 0.2%. Similarly, we find that wire curvature has no significant effect on the determination of the thermal resistance of an ~65 nm SiO 2 layer, even for the sharpest corners considered here, for which the largest measured ratio of the thermal penetration depth of the applied thermal wave to radius of curvature of the heating wire is 4.3. This result provides useful design criteria for three-omega experiments by setting a lower bound for the maximum ratio of the thermal penetration depth to wire radius of curvature.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The {rho} {sup {yields} {gamma}{pi}} and {omega} {sup {yields} {gamma}{pi}} decays in quark-model approach and estimation of coupling for pion emission by quark

In the framework of the relativistic and gauge-invariant spectral integral technique, we calculate radiative decays {rho}(770) {sup {yields} {gamma}{pi}}(140) and {omega}(780) {sup {yields} {gamma}{pi}}(140) supposing all mesons ({pi}, {rho}, and {omega}) to be quark-antiquark states. The qq-bar wave functions found for mesons and photon lead to a reasonably good description of data ( {Gamma} (exp){rho} {+-} to {gamma} {pi} 68 {+-} 30 keV, {Gamma} (exp) {rho} 0 to {gamma} {pi} 0 = 77 {+-} 28 keV, {Gamma} (exp) {omega} to {gamma} {pi} 0 = 776 {+-} 45 keV) which makes it possible to estimate the coupling for the bremsstrahlung emission of pion by quarks g{sub {pi} {identical_to}} g{sub {pi}}(u {sup {yields}}d{pi}). We have found two values for the pion bremsstrahlung coupling: vertical bar g{sub {pi}}vertical bar = 16.7 {+-} 0.3{sub -2.3}{sup +0.1} (Solution I) and vertical bar g{sub {pi}}vertical bar = 3.0 {+-} 0.3{sub -2.1}{sup +0.1} (Solution II). Within SU(6) symmetry for nucleons, Solution I gives us for {pi}NN coupling the value 16.4 {<=} g{sub {pi}NN}{sup 2}(4{pi}) {<=} 23.2, which is in qualitative agreement with the {pi}N scattering data, g{sub {pi}NN}{sup 2}/(4{pi}) {r_brace}{approx} 14. For excited states, we have estimated the partial widths in Solution I as follows: {Gamma}({rho}{sub 2S}{sup {+-} {yields} {gamma}{pi}}) {r_brace}{approx} 10-130 keV, {Gamma}({rho}{sub 2S}{sup 0} {sup {yields} {gamma}{pi}}) {r_brace}{approx} 10-130 keV, {Gamma}({omega}{sub 2S} {sup {yields} {gamma}{pi}}) {r_brace}{approx} 60-1080 keV. The large uncertainties emphasize the necessity to carry out measurements of the meson radiative processes in the region of large masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Matrix Extension Validation of AOCS Ce 2c‐11 for Omega‐3 Polyunsaturated Fatty Acids in Conventional Foods and Dietary Supplements Containing Added Marine Oil

Abstract Marine oils are commonly added to conventional foods and dietary supplements to enhance their contents of omega‐3 polyunsaturated fatty acids (PUFA), including eicosapentaenoic acid (EPA; 20:5n‐3) and docosahexaenoic acid (DHA; 22:6n‐3), which have been associated with numerous potential health benefits. This study compared American Oil Chemists’ Society (AOCS) Official Methods Ce 2b‐11 and Ce 2c‐11 for determining EPA and DHA in foods and dietary supplements and found that AOCS Ce 2c‐11 produces significantly higher analyzed values, which could be attributed to a more comprehensive breakdown of the sample matrix and derivatization of fatty acids. Our subsequent food matrix extension validation of AOCS Ce 2c‐11 demonstrated that the method produces true, accurate, sensitive, and precise determinations of EPA, DHA, and total omega‐3 PUFA in foods and dietary supplements containing added marine oil, including those formulated with emulsified and microencapsulated oils. The method detection limits for EPA and DHA were 0.012 ± 0.002 and 0.011 ± 0.003 mg g −1 , respectively (means ± SD). The analyzed contents of EPA (1.26–386 mg serving −1 ), DHA (1.37–563 mg serving −1 ), and total omega‐3 PUFA (2.69–1270 mg serving −1 ) were reported for 27 conventional food and dietary supplement products. Eighteen products declared contents of DHA, EPA + DHA, or total omega‐3 PUFA on product labels, and the analyzed contents of those fatty acids varied from 95 to 162% of label declarations for all but two of the products.

Li, Ziyi↗