Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OCCUPATION NUMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Energy Impacts of Energy and Indoor Environmental Quality Retrofits of Apartments in California

Monthly gas and electricity use data from a set of 13 study apartments and 20 control apartments from three apartment buildings (B1 B3) in California were analyzed. The study apartments were retrofit with simultaneous energy savings and indoor environmental quality (IEQ) improvements as the goal. The control apartments were not retrofit. Pre-retrofit modeling indicated annual energy savings of 21percent, 17percent, and 27percent for the study apartments in B1-B3, respectively. Based on a comparison of changes in energy use of study apartments to energy use changes of control apartments, total measured savings of gas energy plus site electrical energy were 28percent in B1, 5percent in B2, and 3percent in B3. Given the small number of study apartments and the substantial changes in energy use within control apartments, the project yielded no conclusive evidence of energy savings. Apartment energy use increased with number of occupants and with floor area; however, the association with occupancy was most evident. Climate differences did not appear to be the major driver for the variability in energy use among apartments. Changes in occupant behaviors affecting energy use may have overwhelmed and obscured the energy savings in this small number of buildings. Much larger prior studies employing similar retrofits indicate that the retrofits usually do save energy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Counting Occupants Using Network Technology (COUNT) v0.1

With this COUNT software, we can run a simple query on a campus's Wireless Local Area Network controller (WLAN controller) to obtain the number of connected devices per access point across the whole campus and this can be used as a proxy for the actual number of occupants in the campus. The software supports user defined functions to parse access point names to retrieve more information (e.g.: building names, room numbers etc.) and also allows post-processing of the data.

Prakash, AnandKrishnan↗

Counting Occupants Using Network Technology (COUNT) v0.1

With this COUNT software, we can run a simple query on a campus's Wireless Local Area Network controller (WLAN controller) to obtain the number of connected devices per access point across the whole campus and this can be used as a proxy for the actual number of occupants in the campus. The software supports user defined functions to parse access point names to retrieve more information (e.g.: building names, room numbers etc.) and also allows post-processing of the data.

Pritoni, Marco↗

Fuzzy Linguistic Knowledge Based Behavior Extraction for Building Energy Management Systems

Significant portion of world energy production is consumed by building Heating, Ventilation and Air Conditioning (HVAC) units. Thus along with occupant comfort, energy efficiency is also an important factor in HVAC control. Modern buildings use advanced Multiple Input Multiple Output (MIMO) control schemes to realize these goals. However, since the performance of HVAC units is dependent on many criteria including uncertainties in weather, number of occupants, and thermal state, the performance of current state of the art systems are sub-optimal. Furthermore, because of the large number of sensors in buildings, and the high frequency of data collection, large amount of information is available. Therefore, important behavior of buildings that compromise energy efficiency or occupant comfort is difficult to identify. This paper presents an easy to use and understandable framework for identifying such behavior. The presented framework uses human understandable knowledge-base to extract important behavior of buildings and present it to users via a graphical user interface. The presented framework was tested on a building in the Pacific Northwest and was shown to be able to identify important behavior that relates to energy efficiency and occupant comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Typical occupancy profiles and behaviors in residential buildings in the United States

The energy performance of a residential building is highly dependent on occupant's presence or non-presence in a building and their interactions with energy-consuming appliances. Typical occupancy schedules for residential buildings must be defined for applications such as building energy modeling as well as for assessing energy savings associated with the use of occupancy sensing technologies and occupancy-dependent controls. Currently, commonly used simulation programs assume a typical occupancy schedule, however, there is significant opportunity for improvement to these schedules as this is generally based on engineering judgement. This research uses 12 years of the American Time Use Survey (ATUS) data to develop typical occupancy schedules for a range of household types and occupant age ranges. This is compared to currently utilized residential occupancy schedules. In many cases the developed schedules exhibit similar patterns, however, differences are also found to be as high as 41% for certain periods of time. For occupancy sensing applications, the spatial-temporal distribution of occupants in residential buildings is also evaluated. These locations vary based on temporal factors as well as demographic factors such as age and number of occupants. Finally, the results of this research work towards improved occupancy schedule development can benefit both industry professionals and researchers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. residential consumer product information: Validation of methods for post-stratification weighting of Amazon Mechanical Turk surveys

We present two post-stratification weighting methods to validate survey data collected using Amazon Mechanical Turk (AMT). Two surveys focused on appliance and consumer electronics devices were administered in the spring and summer of 2012 to each of approximately 3,000 U.S. households. Specifically, the surveys asked questions about residential refrigeration products, televisions (TVs) and set-top boxes (STBs). Filtered data were assigned weights using each of two weighting methods, termed “sequential” and “simultaneous,” by examining up to eight demographic variables (income, education, gender, race, Hispanic origin, number of occupants, ages of occupants, and geographic region) in comparison to reference U.S. demographic data from the 2009 Residential Energy Consumption Survey (RECS). Five key questions from the surveys (number of refrigerators, number of freezers, number of TVs, number of STBs and primary service provider) were evaluated with a set of statistical tests to determine whether either method improved the agreement of AMT with reference data, and if so, which method was better. The statistical tests used were: differences in proportions, distributions of proportions (using Pearson’s chi-squared test), and differences in average numbers of devices as functions of all demographic variables. The results indicated that both methods generally improved the agreement between AMT and reference data, sometimes greatly, but that the simultaneous method was usually superior to the sequential method. Some differences in sample populations were found between the AMT and reference data. Differences in the proportion of STBs reflected large changes in the STB market since the time our reference data was acquired in 2009. Differences in the proportions of some primary service providers suggested real sample bias, with the possible explanation that AMT user are more likely to subscribe to providers who also provide home internet service. Differences in other variables, while statistically significant in some cases, were nonetheless considered to be minor. Depending on the intended purpose of the data collected using AMT, these biases may or may not be important; to correct them, additional questions and/or further post-survey adjustments could be employed. In general, based on the analysis methods and the sample datasets used in this study, AMT surveys appeared to provide useful data on appliance and consumer electronics devices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2005 Tahoe Regional Household Travel Survey

The 2005 Tahoe Regional Household Travel Survey is a comprehensive survey of the travel patterns of households in the Tahoe Basin region of California and Nevada. The survey was conducted for the Tahoe Regional Planning Agency over a four-month period, from June through September 2005. This collection contains two sets of travel data: 1) a survey of 1,220 permanent households within the Tahoe Basin region and 2) a subset survey of 125 seasonal households within the same area. The permanent resident dataset contains information about 2,732 household members, 2,471 vehicles, and 11,048 trips made during a 24-hour period. The seasonal resident subset features 726 trip observations and information about 229 household members and 185 vehicles. The survey relied on the willingness of study area residents to 1) provide demographic information about their household, its members, and its vehicles and 2) document all travel for each household member, regardless of age, over an assigned 24-hour period. During the recruitment phase, respondents were asked to provide detailed household information, including permanent or seasonal resident status, number of household occupants, type of dwelling unit, number of vehicles available to household members, as well as the year, body type, and fuel type of each vehicle. Survey participants received mailed travel logs to aid in documenting travel information for the 24-hour assessment period. Respondents were instructed to record their mode of transportation, trip purpose, number of passengers, departure and arrival times, activities at each trip destination, ride fare, and parking costs. Demographic information for this study includes age, gender, income, education, and employment status.

1Hz data↗

A Review of the Use of Wearables in Indoor Environmental Quality Studies and an Evaluation of Data Accessibility from a Wearable Device

An understanding of indoor environmental quality (IEQ) and its effects on occupant well-being can inform building system design and operation. The use of wearables in field studies to collect subjective and objective health performance indicators (HPIs) from a large number of occupants could deliver important improvements in IEQ. To facilitate the use of wearables in IEQ studies, there is a need to identify which HPIs should be collected and to evaluate data accessibility from these devices. To address this issue, a literature review of previous IEQ studies was conducted to identify relationships between different IEQ factors and HPIs, with a focus on HPIs that were collected using wearables. A preliminary assessment of data accessibility from a selected wearable device (Fitbit Versa 2) was performed and documented. The review suggested the need to further investigate and collect sleep quality parameters, heart rate, stress response, as well as subjective ratings of comfort using wearables. The data accessibility assessment revealed issues related to missing data points and data resolution from the examined device. A set of recommendations is outlined to inform future studies.

60 APPLIED LIFE SCIENCES↗

Genetic variation and genetic complexity of nodule occupancy in soybean inoculated with USDA110 and USDA123 rhizobium strains

Abstract Background Symbiotic nitrogen fixation differs among Bradyrhizobium japonicum strains. Soybean inoculated with USDA123 has a lower yield than strains known to have high nitrogen fixation efficiency, such as USDA110. In the main soybean-producing area in the Midwest of the United States, USDA123 has a high nodule incidence in field-grown soybean and is competitive but inefficient in nitrogen fixation. In this study, a high-throughput system was developed to characterize nodule number among 1,321 Glycine max and 69 Glycine soja accessions single inoculated with USDA110 and USDA123. Results Seventy-three G. max accessions with significantly different nodule number of USDA110 and USDA123 were identified. After double inoculating 35 of the 73 accessions, it was observed that PI189939, PI317335, PI324187B, PI548461, PI562373, and PI628961 were occupied by USDA110 and double-strain nodules but not by USDA123 nodules alone. PI567624 was only occupied by USDA110 nodules, and PI507429 restricted all strains. Analysis showed that 35 loci were associated with nodule number in G. max when inoculated with strain USDA110 and 35 loci with USDA123. Twenty-three loci were identified in G. soja when inoculated with strain USDA110 and 34 with USDA123. Only four loci were common across two treatments, and each locus could only explain 0.8 to 1.5% of phenotypic variation. Conclusions High-throughput phenotyping systems to characterize nodule number and occupancy were developed, and soybean germplasm restricting rhizobium strain USDA123 but preferring USDA110 was identified. The larger number of minor effects and a small few common loci controlling the nodule number indicated trait genetic complexity and strain-dependent nodulation restriction. The information from the present study will add to the development of cultivars that limit USDA123, thereby increasing nitrogen fixation efficiency and productivity.

59 BASIC BIOLOGICAL SCIENCES↗

Determinants of residential electricity consumption: Using smart meter data to examine the effect of climate, building characteristics, appliance stock, and occupants' behavior

We propose a method to examine structural and behavioral determinants of residential electricity consumption, by developing separate models for daily maximum (peak) and minimum (idle) consumption. We apply our method on a data set of 1628 households' electricity consumption. The results show that weather, location and floor area are among the most important determinants of residential electricity consumption. In addition to these variables, number of refrigerators and entertainment devices (e.g., VCRs) are among the most important determinants of daily minimum consumption, while number of occupants and high-consumption appliances such as electric water heaters are the most significant determinants of daily maximum consumption. Installing double-pane windows and energy-efficient lights helped to reduce consumption, as did the energy-conscious use of electric heater. Acknowledging climate change as a motivation to save energy showed correlation with lower electricity consumption. Households with individuals over 55 or between 19 and 35 years old recorded lower electricity consumption, while pet owners showed higher consumption. Contrary to some previous studies, we observed no significant correlation between electricity consumption and income level, home ownership, or building age. Some otherwise energy-efficient features such as energy-efficient appliances, programmable thermostats, and insulation were correlated with slight increase in electricity consumption. (C) 2013 Elsevier Ltd. All rights reserved.

Kavousian, A↗

Downward quantum learning from element 118: Automated generation of Fermi–Löwdin orbitals for all atoms

A new algorithm based on a rigorous theorem and quantum data computationally mined from element 118 guarantees automated construction of initial Fermi–Löwdin-Orbital (FLO) starting points for all elements in the Periodic Table. It defines a means for constructing a small library of scalable FLOs for universal use in molecular and solid-state calculations. The method can be systematically improved for greater efficiency and for applications to excited states such as x-ray excitations and optically silent excitations. FLOs were introduced to recast the Perdew–Zunger self-interaction correction (PZSIC) into an explicit unitarily invariant form. The FLOs are generated from a set of N quasi-classical electron positions, referred to as Fermi-Orbital descriptors (FODs), and a set of N-orthonormal single-electron orbitals. FOD positions, when optimized, minimize the PZSIC total energy. However, creating sets of starting FODs that lead to a positive definite Fermi orbital overlap matrix has proven to be challenging for systems composed of open-shell atoms and ions. The proof herein guarantees the existence of a FLOSIC solution and further guarantees that if a solution for N electrons is found, it can be used to generate a minimum of N – 1 and a maximum of 2 N – 2 initial starting points for systems composed of a smaller number of electrons. As a result, applications to heavy and super-heavy atoms are presented. All starting solutions reported here were obtained from a solution for element 118, Oganesson.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A method to generate heating and cooling schedules based on data from connected thermostats

Internet-connected thermostats are a promising new source of temperature and operational data in homes because they record inside temperatures, setpoints, and HVAC runtimes every five minutes. Over 20 million Internet-connected thermostats have already been installed in American homes. Data from about 20,000 connected thermostats were collected and organized by climate zone, number of occupants, floor area, and day type. A method was developed to create up to 40 representative temperature schedules which, together, can more accurately capture the diversity of heating and cooling behaviors. These results are suitable for input into schedules for building energy simulation models. This information enables more realistic simulations of American heating and cooling behavior, leading to more accurate estimates of energy consumption and savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dialing in Catalytic Sites on Metal Organic Framework Nodes: MIL-53(Al) and MIL-68(Al) Probed with Methanol Dehydration Catalysis

Many metal organic frameworks (MOFs) incorporate metal oxide clusters as nodes. Node sites where linkers are missing can be catalytic sites. We now show how to dial in the number and occupancy of such sites in MIL-53 and MIL-68, which incorporate aluminum-oxide-like nodes. Here, the methods involve modulators used in synthesis and postsynthesis reactions to control the modulator-derived groups on these sites. We illustrate the methods using formic acid as a modulator, giving formate ligands on the sites, and these can be removed to leave μ 2 -OH groups and open Lewis acid sites. Methanol dehydration was used as a catalytic reaction to probe these sites, with infrared spectra giving evidence of methoxide ligands as reaction intermediates. Control of node surface chemistry opens the door for placement of a variety of ligands on a wide range of metal oxide cluster nodes for dialing in reactivity and catalytic properties of a potentially immense class of structurally well-defined materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The many-body expansion for metals. I. The alkaline earth metals Be, Mg, and Ca

We examine the many-body expansion (MBE) for alkaline earth metal clusters, Be n , Mg n , Ca n ( n = 4, 5, 6), at the Møller–Plesset second order perturbation theory, coupled-cluster singles and doubles with perturbative triples, multi-reference perturbation theory, and multi-reference configuration interaction levels of theory. The magnitude of each term in the MBE is evaluated for several geometrical configurations. We find that the behavior of the MBE for these clusters depends strongly on the geometrical arrangement and, to a lesser extent, on the level of theory used. Another factor that affects the MBE is the in situ (ground or excited) electronic state of the individual atoms in the cluster. For most geometries, the three-body term is the largest, followed by a steady decrease in absolute energy for subsequent terms. Though these systems exhibit non-negligible multi-reference effects, there was little qualitative difference in the MBE when employing single vs multi-reference methods. Useful insights into the connectivity and stability of these clusters have been drawn from the respective potential energy surfaces and quasi-atomic orbitals for the various dimers, trimers, and tetramers. Through these analyses, we investigate the similarities and differences in the binding energies of different-sized clusters for these metals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

N -representability violations in truncated equation-of-motion coupled-cluster methods

One-electron reduced density matrices (1RDMs) from equation-of-motion (EOM) coupled-cluster with single and double excitations (CCSD) calculations are analyzed to assess their N-representability (i.e., whether they are derivable from a physical N-electron state). We identify EOM-CCSD stationary states whose 1RDMs violate either ensemble-state N-representability conditions or pure-state conditions known as generalized Pauli constraints. As such, these 1RDMs do not correspond to any physical N-electron state. Unphysical states are also encountered in the course of time-dependent EOM-CC simulations; when an external field drives transitions between a pair of stationary states with pure-state N-representable 1RDMs, the 1RDM of the time-dependent state can violate ensemble-state conditions. Furthermore, these observations point to potential challenges in interpreting the results of time-dependent EOM-CCSD simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linear-scaling quadruple excitations in local pair natural orbital coupled-cluster theory

Here, we present a fast, asymptotically linear-scaling implementation of the perturbative quadruples energy correction in coupled-cluster theory using local natural orbitals. Our work follows the domain-based local pair natural orbital (DLPNO) approach previously applied to lower levels of excitations in coupled-cluster theory. Our DLPNO-CCSDT(Q) algorithm uses converged doubles and triples amplitudes from a preceding DLPNO-CCSDT computation to compute the quadruples amplitude and energy in the quadruples natural orbital (QNO) basis. We demonstrate the compactness of the QNO space, showing that more than 95% of the (Q) correction can be recovered using relatively loose natural orbital cutoffs, compared to the tighter cutoffs used in pair and triples natural orbitals at lower levels of coupled-cluster theory. We also highlight the accuracy of our algorithm in the computation of relative energies, which yields deviations of sub-kJ mol −1 in relative energy compared to the canonical CCSDT(Q). Timings are conducted on a series of growing linear alkanes (up to 10 carbons and 608 basis functions) and water clusters (up to 49 water molecules and 2842 basis functions) to establish the asymptotic linear-scaling of our DLPNO-(Q) algorithm.

Auxiliary functions↗

Raman Sideband Cooling of Molecules in an Optical Tweezer Array to the 3D Motional Ground State

Ultracold polar molecules are promising for quantum information processing and searches for physics beyond the standard model. Laser cooling to ultracold temperatures is an established technique for trapped diatomic and triatomic molecules. Further cooling of the molecules to near the motional ground state is crucial for reducing various dephasings in quantum and precision applications. In this work, we demonstrate Raman sideband cooling (RSC) of CaF molecules in optical tweezers to near their motional ground state, with average motional occupation quantum numbers of n ¯ x = 0.16 ( 12 ) , n ¯ y = 0.17 ( 17 ) (radial directions), and n ¯ z = 0.22 ( 16 ) (axial direction), and a 3-D motional-ground-state probability of 54 ± 18 % of the molecules that survive the RSC. This process paves the way to increase molecular coherence times in optical tweezers for robust quantum computation and simulation applications. Published by the American Physical Society 2024

Physics↗