Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Commissioning of the neutron irradiation station at the University of Notre Dame

Cross section data for neutron-induced reactions are needed for applications in nuclear astrophysics, stockpile stewardship, and nuclear reactor design but often contain discrepancies and gaps. A neutron source with a high neutron flux, a well-characterized neutron energy distribution, and a wide range of available neutron energies is ideal for studying such reactions in order to improve on existing data and provide new experimental results. For this purpose, the Neutron Irradiation Station (NIS) was developed using the 7 Li(p,n) 7 Be reaction. Neutron energy profiles were obtained using 3 He spectrometers and neutron standards were used to determine the neutron flux using the activation method. The neutron energy profile was found to be quasi-monoenergetic and neutrons were produced at energies from 1 keV to 1 MeV. Finally, the flux at the production target was found to be (1.42 ± 0.20) x 10 8 s −1 cm −2 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. In this work, the new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magnetogravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron calorimeter development at fission and fusion pulsed neutron sources

A neutron calorimeter fielded in pulsed neutron irradiation experiments at the National Ignition Facility (NIF) and White Sands Missile Range Fast Burst Reactor (WSMR FBR) is described, and results are provided and discussed. The calorimeter is modular in design to allow fielding of various neutron absorber materials and thicknesses, as well as use at both fission and fusion sources, all of which has been done. Neutron calorimeters designed for fission sources have been fielded at fusion sources as well, but these instances are not documented in available literature—making this work novel. The functional calorimeter consists of a neutron absorber and two sheathed, grounded thermocouples secured within a subassembly made of thermally insulating materials. This subassembly is placed into a sealed vessel for material and facility safety considerations. The device was fielded at NIF in four polar-direct-drive exploding pusher shots and eleven WSMR FBR pulses. Calorimeter data from NIF experiments show a discernable thermal response accredited to neutron heating within the first 10 s, but the data are dominated by noise from ambient X-ray heating after time = 10 s post-pulse. This response is highly consistent between shots and linearly related to incident neutron fluence and neutron absorber thickness. A temperature rise of 1.1E-2 K/(10 13 neutrons/cm 2 ) per millimeter of absorber thickness was determined for both 0.4 mm and 1 mm thick depleted uranium absorbers with linear best fit R 2 of 0.97 and 0.98 for each thickness and y-axis offsets of 8.8E-3 and 1.3E-2, respectively. WSMR FBR experiment data show a temperature rise of 6.2E-2 K/(10 13 neutrons/cm 2 ) with linear best fit R 2 of 0.14 and y-axis offset of 7.6E-3 for a calorimeter with a 1 mm thick enriched boron carbide ( 10 B 4 C) absorber, though it must be noted that device-to-device variability is significant at both facilities. So these data are also affected by noise on a similar timescale as at NIF, though the noise is significantly lesser in magnitude but oscillatory.

42 ENGINEERING↗

Scintillation characteristics of the EJ-299-02H scintillator

Here a study of the dead layer thickness and quenching factor of a plastic scintillator for use in ultracold neutron (UCN) experiments is described. Alpha spectroscopy was used to determine the thickness of a thin surface dead layer to be 630 ± 110 nm. The relative light outputs from the decay of 241 Am and Compton scattering of electrons were used to extract Birks’ law coefficient, yielding a kB value of 0.087 ± 0.003 mm/MeV, consistent with some previous reports for other polystyrene-based scintillators. The results from these measurements are incorporated into the simulation to show that an energy threshold of (∼9 keV) can be achieved for the UCNProBe experiment. This low threshold enables high beta particle detection efficiency and the indirect measurement of UCN. The ability to make the scintillator deuterated, accompanied by its relatively thin dead layer, gives rise to unique applications in a wide range of UCN experiments, where it can be used to trap UCN and detect charged particles in situ.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Including 238 U(n,f)/ 235 U(n,f) and 239 Pu(n,f)/ 235 U(n,f) NIFFTE fission TPC Cross-sections into the Neutron Data Standards Database

The primary purpose of this report is to document how the 238 U/ 235 U and 239 Pu/ 235 U neutron induced fission cross-section ratios, 238 U(n,f)/ 235 U(n,f) and 239 Pu(n,f)/ 235 U(n,f), respectively, measured by the NIFFTE fission Time Projection Chamber (fissionTPC) were included in the most recent database (termed GMA) underlying Neutron Data Standards (NDS) evaluations. This report shows and discusses NDS input files, and underlying assumptions regarding the uncertainty estimate and necessary for including these data. This uncertainty estimate and the resulting files were based on information provided by fissionTPC experimentalists, R.J.Casperson, N.S. Bowden, L. Snyder and K.T. Schmitt for the 238 U ratio, and by L. Snyder for the 239 Pu ratio. The fissionTPC data were included twice, by D. Neudecker and V. Pronyaev, to counter-check results and exclude possible mistakes in their inclusion. It is shown in both evaluations that including fissionTPC 239 Pu(n,f)/ 235 U(n,f) data points to a lower evaluated 239 Pu(n,f) cross section above 10 MeV than the currently released NDS data. This raises the question whether a part of a previous dataset by Tovesson et al., that was previously rejected above 13 MeV for having low values, should be included in the NDS evaluation after all. The evaluated 238 U(n,f) cross section only changes significantly close to the threshold. The impact on the 235 U(n,f) cross section is minimal. fissionTPC data reduce evaluated uncertainties on both observables by 0–12% of the GMA evaluated uncertainties. However, the currently released NDS data contain in addition to these GMA evaluated uncertainties “Unrecognized Sources of Uncertainties” (USU) of 1.2%. It needs to be further discussed within the NDS project, whether the new fissionTPC data should also reduce USU.

238U(n,f)/235U(n,f)↗

Software Quality Assurance for the MOOSE-Based Open-Source Multiphysics Code Cardinal - An Expanded CI Testing Suite

Cardinal is a wrapping of the GPU-oriented spectral element Computational Fluid Dynamics (CFD) code NekRS and the Monte Carlo particle transport code OpenMC within the Multiphysics Object-Oriented Simulation Environment (MOOSE). Cardinal provides high-resolution thermal-hydraulics and/or radiation transport feedback to MOOSE multiphysics simulations. Multiphysics feedback is implemented in a geometry-agnostic manner which eliminates the need for rigid one-to-one mappings. A generic data transfer implementation also allows NekRS and OpenMC to couple to any MOOSE application, enabling a broad set of multiphysics capabilities. Cardinal simulations can also leverage combinations of MPI, OpenMP, and GPU resources. Cardinal continuous development and improvement efforts have led to the software being considered as a high-fidelity design and licensing tool for key areas of nuclear reactor relevant physics, including neutron transport, fluid flow, heat transfer, and mechanical processes. The fast development and expansion of the software from a pure R&D framework towards its application in the nuclear industry and regulation require a focus on developing, enhancing and, maintaining Cardinal’s software quality through strict adherence to a Software Quality Assurance (SQA) framework and SQA program. To facilitate compliance with SQA standards, the Cardinal SQA Program has been initiated during Fiscal Year 2023 (FY23). During the development of the Cardinal SQA Program, multiple gaps have been identified. These gaps are primarily related to model verification and code pedigree as they relate to the use of Cardinal as a safety analysis tool. These gaps have been captured in a report published in 2023. A second report highlighted the progress made during Fiscal Year 2024 (FY24) and described Argonne’s effort to document and integrate software verification within Cardinal’s software development process. This report documents a snapshot of the verification test cases currently available for Cardinal and NekRS in their assimilation into a Continuous Integration (CI) platform. Following the CI practice permits the integrating of source code changes frequently and ensuring that the integrated codebase clears the verification testing for the software. It should be noted that the SQA program itself, including the program plans, procedures, configuration management, and testing strategies, need to be developed in a future step of this task.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Progress Towards NQA-1 for Cardinal in FY25

Cardinal is a wrapping of the GPU-oriented spectral element Computational Fluid Dynamics (CFD) code NekRS and the Monte Carlo particle transport code OpenMC within the Multiphysics Object-Oriented Simulation Environment (MOOSE). Cardinal provides high-resolution thermal-hydraulics and/or radiation transport feedback to MOOSE multiphysics simulations. Multiphysics feedback is implemented in a geometry-agnostic manner which eliminates the need for rigid one-to-one mappings. A generic data transfer implementation also allows NekRS and OpenMC to couple to any MOOSE application, enabling a broad set of multiphysics capabilities. Cardinal simulations can also leverage combinations of MPI, OpenMP, and GPU resources. Cardinal continuous development and improvement efforts have led to the software being considered as a high-fidelity design and licensing tool for key areas of nuclear reactor relevant physics, including neutron transport, fluid flow, heat transfer, and mechanical processes. The fast development and expansion of the software from a pure R&D framework towards its application in the nuclear industry and regulation require a focus on developing, enhancing,and maintaining Cardinal’s software quality through strict adherence to a Software Quality Assurance (SQA) framework and SQA program. To facilitate compliance with SQA standards, the Cardinal SQA Program was initiated during Fiscal Year 2023 (FY23). During the development of the Cardinal SQA Program, multiple gaps have been identified. These gaps are primarily related to model verification and code pedigree as they relate to the use of Cardinal as an analysis tool. These gaps were captured in a report published in 2023. A second report highlighted the progress made during Fiscal Year 2024 (FY24) and described Argonne’s effort to document and integrate software verification within Cardinal’s software development process. This report documents the progress made towards NQA-1 for Cardinal in the Fiscal Year 2025 (FY25). All cases in the expanded Continuous Integration (CI) suite of NekRS are included in this report which test the solvers and modules available in NekRS exhaustively. The NekRS tests are integrated with the Cardinal CI suite and made available in publicly accessible Github documentation. Following the CI practice permits integrating of source code changes frequently and ensuring that the integrated codebase clears the verification testing for the software. Also in this report is a brief overview of the development of the Cardinal Software Quality Assurance Plan (SQAP) that was done in FY25, though it should be noted that the rest of the documentation for the SQA program needs to be developed in a future step of this task.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of 𝜋 0 production in $\bar{v}_μ$ charged-current interactions in the NOvA near detector

We present a high-statistics measurement of muon antineutrino-induced charged-current neutral pion production on a hydrocarbon target using the NOvA near detector. The differential cross sections as functions of the momenta and angles of the outgoing pion and muon, the squared four-momentum transfer, and the invariant mass of the hadronic system at an average neutrino energy of 2 GeV are measured and compared with predictions from various neutrino interaction models. The results agree with the GENIE prediction but suggest that other models underestimate the cross section in the Δ⁡(1232) resonance region. These results represent the most precise measurement of antineutrino-induced neutral pion production to date.

neutrino detection↗

Universal Nuclear Accident Dosimeter

The Lawrence Livermore National Laboratory (LLNL) Universal Nuclear Accident Dosimetry (UNAD) project is a four-year initiative aimed at advancing nuclear accident dosimetry methods. This article presents an overview of the research, key findings, and the progress made throughout the project. The primary goals included a background into the history of nuclear accident dosimetry, consolidating current dosimetry techniques within the NNSA/DOE complex, fostering collaboration among subject matter experts, and exploring novel technologies for potential implementation. The technical focus centered on investigating new and novel technologies, instrumentation methods, and analysis methods to develop recommendations for a potential nuclear accident dosimeter (NAD) to be universally deployed through the DOE complex. A multilaboratory and multinational Usergroup was established, conducting periodic meetings to facilitate knowledge exchange. The UNAD team has participated in two international nuclear accident dosimetry intercomparison exercises and one characterization exercise, where the existing LLNL NAD and a prototype alanine electron paramagnetic dosimeter NAD were deployed. Ongoing improvements are being made to the prototype NAD based on results from the exercises, laboratory studies, and collaboration with other laboratories. A machine learning algorithm to optimize the geometry and conversion factors of the current LLNL NAD is being implemented, and the resulting design will be tested in the next exercise. In conclusion, key lessons learned and future directions for the project are discussed.

Electron paramagnetic resonance spectroscopy↗

Inverse Method for Noninvasive Material Discrimination with Multienergy X-Ray Radiography

Active x-ray inspections have great potential for noninvasive detection of illicit materials. Dual-energy x-ray radiography, in particular, has been used to determine material composition by utilizing the energy-dependence of the x-ray attenuation coefficients. However, current implementations of this method are limited in their ability to determine the material composition of composite objects. Here, in this paper, we present an inverse algorithm that uses multienergy x-ray radiography data to noninvasively reconstruct the contents of a container. A critical feature of the current contribution is that material identification can be performed using conventional detectors and x-ray spectra with different endpoint energies produced by varying nothing more than the tube voltage. Adaptive regularization is used to increase the accuracy of material estimations from multienergy data sets. The utility of these methods is demonstrated with experimentally acquired radiographs obtained using a tunable x-ray source that produces spectra with endpoint energies of 100–450 keV. The object inspected is a scale model of a nuclear materials storage container composed of three-dimensional printed plastic and stainless-steel spheres inside a thin-walled steel container. Reconstructions of the steel sphere thicknesses are within a root-mean-square error of 0.37 cm.

47 OTHER INSTRUMENTATION↗

Detection of uranium-photofission neutrons with a 4 He scintillation detector

The use of photon active interrogation to detect special nuclear material has held significant theoretical promise, as the interrogating source particles, photons, are fundamentally different from one of the main signatures of special nuclear material: neutrons produced in nuclear fission. However, neutrons produced by photonuclear reactions in the accelerator target, collimator, and environment can obscure the fission neutron signal. These (γ, n) neutrons could be discriminated from fission neutrons by their energy spectrum, but common detectors sensitive to the neutron spectrum, like organic scintillators, are typically hampered by the intense photon background characteristic of photon-based active interrogation. In contrast, high-pressure 4 ⁢He-based scintillation detectors are well-suited to photon active interrogation, as they are similarly sensitive to fast neutrons and can measure their spectrum, but show little response to gamma rays. Here, in this work, a photon active interrogation system utilizing a 4 ⁢He scintillation detector and a 9 MeV linac-bremsstrahlung x-ray source was experimentally evaluated. The detector was shown to be capable of operating in intense gamma-ray environments and detecting photofission neutrons from 238 ⁢U when interrogated by this x-ray source. The photofission neutrons show clear spectral separation from (γ, n) neutrons produced in lead, a common shielding material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First observation of isolated nuclear recoils following neutron capture for dark matter calibration

Low-energy nuclear recoils (NRs) are hard to measure, because they produce few e - /h + pairs in solids—i.e., they have low “ionization yield.” A silicon detector was exposed to thermal neutrons over 2.5 live days, probing NRs down to 450 eV. The observation of a neutron capture-induced component of NRs at low energies is supported by the much-improved fit upon inclusion of a capture NR model. This result shows that thermal neutron calibration of very low recoil energy NRs is promising for dark matter searches, coherent neutrino experiments, and improving understanding of ionization dynamics in solids.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessing equation of state-independent relations for neutron stars with nonparametric models

Relations between neutron star properties that do not depend on the nuclear equation of state offer insights on neutron star physics and have practical applications in data analysis. Such relations are obtained by fitting to a range of phenomenological or nuclear physics equation of state models, each of which may have varying degrees of accuracy. In this study we revisit commonly used relations and reassess them with a very flexible set of phenomenological nonparametric equation of state models that are based on Gaussian processes. Our models correspond to two sets: equations of state which mimic hadronic models, and equations of state with rapidly changing behavior that resemble phase transitions. Here we quantify the accuracy of relations under both sets and discuss their applicability with respect to expected upcoming statistical uncertainties of astrophysical observations. We further propose a goodness-of-fit metric which provides an estimate for the systematic error introduced by using the relation to model a certain equation-of-state set. Overall, the nonparametric distribution is more poorly fit with existing relations, with the I–Love–Q relations retaining the highest degree of universality. Fits degrade for relations involving the tidal deformability, such as the binary-Love and compactness-Love relations, and when introducing phase transition phenomenology. For most relations, systematic errors are comparable to current statistical uncertainties under the nonparametric equation of state distributions.

79 ASTRONOMY AND ASTROPHYSICS↗

Modern nuclear and astrophysical constraints of dense matter in a redefined chiral approach

Here, we explore the quantum chromodynamics (QCD) phase diagram’s complexities, including quark deconfinement transitions, liquid-gas phase changes, and critical points by using the chiral mean-field (CMF) model that is able to capture all these features. We introduce a vector meson field redefinition within the CMF framework, enabling precise adjustments of meson masses and coupling strengths related to vector meson interactions. Performing a new fit to the deconfinement potential, we are able to replicate recent lattice QCD results, low-energy nuclear physics properties, neutron star observational data, and key phase diagram features as per modern constraints. This approach enhances our understanding of vector mesons’ roles in mediating nuclear interactions and their impact on the equation of state, contributing to a more comprehensive understanding of the QCD phase diagram and its implications for nuclear and astrophysical phenomena.

QCD phase transitions↗

Inversion of Many-Beam Bragg Intensities for Phasing by Iterated Projections: Removal of Multiple Scattering Artifacts from Diffraction Data

An iterated projection algorithm (N-Phaser) is developed that reconstructs a scattering potential from N-beam multiple Bragg scattered intensities. The method may be used to eliminate multiple scattering artifacts from electron diffraction data, solving the phase problem and increasing the thicknesses of samples used in materials science, solid-state chemistry, and small molecule crystallography. For high-energy transmission electron diffraction, we show that the algorithm recovers accurate complex structure factors from a wide range of thicknesses, orientations, and relativistic beam energies, and does not require known thickness or atomic-resolution data if sufficient multiple scattering occurs. Furthermore, extensions to Cryo-electron microscopy and Micro-electron diffraction are suggested.

36 MATERIALS SCIENCE↗

Cation Dynamics in Hybrid Halide Perovskites

Hybrid halide perovskite semiconductors exhibit complex, dynamical disorder while also harboring properties ideal for optoelectronic applications that include photovoltaics. However, these materials are structurally and compositionally distinct from traditional compound semiconductors composed of tetrahedrally coordinated elements with an average valence electron count of silicon. The additional dynamic degrees of freedom of hybrid halide perovskites underlie many of their potentially transformative physical properties. Neutron scattering and spectroscopy studies of the atomic dynamics of these materials have yielded significant insights into their functional properties. Specifically, inelastic neutron scattering has been used to elucidate the phonon band structure, and quasi-elastic neutron scattering has revealed the nature of the uncorrelated dynamics pertaining to molecular reorientations. Understanding the dynamics of these complex semiconductors has elucidated the temperature-dependent phase stability and origins of defect-tolerant electronic transport from the highly polarizable dielectric response. Furthermore, the dynamic degrees of freedom of the hybrid perovskites provide additional opportunities for application engineering and innovation.

Materials Science↗