Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

In-situ observation of calcium chloride hexahydrate phase separation via neutron imaging

Inorganic salt hydrate offers a low-cost thermal energy storage solution with high energy density, but phase separation during thermal cycling poses a significant challenge, leading to irreversible performance degradation. In this research, neutron radiography was used to investigate phase separation in calcium chloride hexahydrate (CaCl₂·6H₂O, CCH) during thermal cycling to track its gradual accumulation into calcium chloride tetrahydrate (CaCl₂·4H₂O, CC4). Through in-situ visualization, phase separation and CC4 sedimentation were observed to occur during the cooling phase between 301.40 K and 304.80 K. CC4 accumulated linearly to 7.99 wt% after 10 thermal cycles. Crystallization and multi-cycle conversion models were developed to validate neutron imaging results of CC4 formation. The predicted CC4 content after 10 thermal cycles closely aligned with experimental observations. Neutron imaging offers a novel approach to investigate salt hydrate phase change materials (PCMs). It enables in-situ visualization of sub-hydrate (CC4) formation from original hydrate (CCH) in metastable phase change range (between 301.40 ± 0.66 K and 304.80 ± 0.60 K). Thereby, it provides a new insight of understanding the basis of phase separation mechanism and paves the way for future research of improving PCM thermal cycling performance.

Li, Yucen [The University of Tennessee, Knoxville]↗

Lithium indium diselenide: A new scintillator for neutron imaging

Lithium indium diselenide, 6 LiInSe 2 or LISe, is a newly developed neutron detection material that shows both semiconducting and scintillating properties. The 24% atomic density of 6 Li yields a thermal neutron mean free path of only 920 μm. This paper reports on the performance of LISe crystals in scintillation mode for its potential use as a converter screen for thermal/cold neutron imaging. The spatial resolution of LISe, determined using a 10% value of the Modulation Transfer Function (MTF), was found to not scale linearly with thickness. Crystals having a thickness of 450 μm or larger resulted in an average spatial resolution of 67 μm, and the thinner crystals exhibited an increase in spatial resolution down to the Nyquist frequency of the CCD. The highest measured spatial resolution of 198 μm thick LISe (27 μm) outperforms a commercial 50 μm thick ZnS(Cu): 6 LiF scintillation screen (100 μm) by more than a factor of three. For the thicknesses considered in this study, it has been found that the light yield of LISe did not scale with its thickness, suggesting the need for optimizing the synthesis to enhance the scintillation mechanism. Absorption measurements indicate that the 6 Li concentration is uniform throughout the samples and its absorption efficiency as a function of thickness follows general nuclear theory, indicating that the variation in apparent brightness is likely due to a combination of particle escape, light transport, and activation of the scintillation mechanisms. As a result, the presence of 115 In and its long-lived 116 In activation product did not result in ghosting (memory of past neutron exposure), demonstrating potential for using LISe for imaging transient systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

One-Dimensional Neutron Imager for the Sandia Z Facility

A multi-institution collaboration is developing a neutron imaging system for the Sandia Z Facility. The initial system design is for slit-aperture imaging system capable of obtaining a 1-D image of a 2.45-MeV source producing 5 x 10{sup 12} neutrons with a resolution of 320 {micro}m along the axial dimension of the plasma, but the design being developed can be modified for 2-D imaging and imaging of DT neutrons with other resolutions. This system will allow us to understand the spatial production of neutrons in the plasmas produced at the Z Facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operando Neutron Imaging of Lithium Flux and Gradient Cathode Design for Enhanced Kinetics in High‐Loading All‐Solid‐State Li─S Batteries

All-solid-state Li–sulfur batteries (ASSLSBs) are considered promising candidates for next-generation energy storage owing to their inherent safety, high energy density, and abundant sulfur resources. However, slow redox kinetics greatly limit sulfur utilization during solid-solid sulfur reactions, leading to significant challenges to achieve efficient performance in high-mass-loading ASSLSBs. Here, operando neutron image is employed to directly visualize, for the first time, that sluggish Li + transport kinetics and the uneven distribution of Li + during cathodic reactions are critical factors limiting sulfur conversion. To address this issue, gradient cathode architectures comprising three and five layers are designed, in which catholyte concentrations are strategically varied to optimize Li-ion flux and enhance ionic conductivity of the whole composite cathode electrode. Operando neutron imaging distinctly visualizes and confirms that three-layer gradient approach significantly enhances Li-ion mobility, resulting in more uniform redox reactions and greatly improved sulfur utilization compared to traditional non-gradient structures. Consequently, the three-layer gradient cathode achieves superior rate performance and reduced electrode polarization at high sulfur mass loadings of 4.5 and 6.0 mg cm −2 . Furthermore, the applicability and scalability of this design are demonstrated in a five-layer gradient cathode architecture, achieving an impressive discharge specific capacity increase from 656 mAh g −1 (three-layer gradient) to 1232 mAh g −1 at 1/20 C for ultra-high sulfur loading of 7.5 mg cm −2 . In conclusion, this innovative gradient cathode design offers substantial advancements in understanding and overcoming Li-ion transport limitations, paving the way toward practical, high-energy-density ASSLSBs.

25 ENERGY STORAGE↗

Neutron Imaging of Diesel Particulate Filters

This article presents nondestructive neutron computed tomography (nCT) measurements of Diesel Particulate Filters (DPFs) as a method to measure ash and soot loading in the filters. Uncatalyzed and unwashcoated 200cpsi cordierite DPFs exposed to 100% biodiesel (B100) exhaust and conventional ultra low sulfur 2007 certification diesel (ULSD) exhaust at one speed-load point (1500rpm, 2.6bar BMEP) are compared to a brand new (never exposed) filter. Precise structural information about the substrate as well as an attempt to quantify soot and ash loading in the channel of the DPF illustrates the potential strength of the neutron imaging technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Imaging Reveals Internal Plant Hydraulic Dynamics

Many terrestrial ecosystem processes are constrained by water availability and transport within the soil. Knowledge of plant water fluxes is thus critical for assessing mechanistic processes linked to biogeochemical cycles, yet resolution of root structure and xylem water transport dynamics has been a particularly daunting task for the ecologist. Through neutron imaging, we demonstrate the ability to non-invasively monitor individual root functionality and water fluxes within Zea mays L. (maize) and Panicum virgatum L. (switchgrass) seedlings growing in a sandy medium. Root structure and growth were readily imaged by neutron radiography and neutron computed tomography. Seedlings were irrigated with water or deuterium oxide and imaged through time as a growth lamp was cycled on to alter leaf demand for water. Sub-millimeter scale resolution reveals timing and magnitudes of root water uptake, redistribution within the roots, and root-shoot hydraulic linkages, relationships not well characterized by other techniques.

Warren, Jeffrey↗

Wavelength-Shifting-Fiber Scintillation Detectors for Thermal Neutron Imaging at SNS

We have developed wavelength-Shifting-fiber Scintillator Detector (SSD) with 0.3 m2 area per module. Each module has 154 x 7 pixels and a 5 mm x 50 mm pixel size. Our goal is to design a large area neutron detector offering higher detection efficiency and higher count-rate capability for Time-Of-Flight (TOF) neutron diffraction in Spallation Neutron Source (SNS). A ZnS/6LiF scintillator combined with a novel fiber encoding scheme was used to record the neutron events. A channel read-out-card (CROC) based digital-signal processing electronics and position-determination algorithm was applied for neutron imaging. Neutron-gamma discrimination was carried out using pulse-shape discrimination (PSD). A sandwich flat-scintillator detector can have detection efficiency close to He-3 tubes (about 10 atm). A single layer flat-scintillator detector has count rate capability of 6,500 cps/cm2, which is acceptable for powder diffractometers at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ monitoring of hydrogen loss during pyrolysis of wood by neutron imaging

Hydrogen is an element of fundamental importance for energy but hard to quantify in bulk materials. Neutron radiography was used to map in situ loss of elemental hydrogen from beech tree wood samples during pyrolysis. The samples consisted of three wood cylinders (finished dowel or cut branch) of approximately 1 cm in length. The samples were pyrolyzed under vacuum in a furnace vessel that was placed inside a cold neutron imaging beamline using a temperature ramp of 5 °C/min from ambient up to 400 °C. Neutron radiographs with exposures of 30 s were sequentially recorded with a charge-coupled device over the course of the experiment. Relative absorbance/scattering of the neutron beam by each sample was based on intensity (or brightness) values as a function of pixel position. The much larger neutron cross section for hydrogen compared to carbon and oxygen enables almost direct conversion of neutron attenuation into sample hydrogen content for each time step during the pyrolysis experiment. Target and vessel temperatures were recorded concurrently with collection of the radiographs so that changes could be directly correlated to different states of pyrolysis. The most visible change appeared at the initial phase of the 400 °C plateau as evidenced by strong hydrogen loss and primarily diametric shrinking of the samples. In conclusion, the loss of elemental hydrogen between initial and final states of pyrolysis was estimated to be about 70%.

08 HYDROGEN↗

Investigation of dissimilar metal welds by energy-resolved neutron imaging

A nondestructive study of the internal structure and compositional gradient of dissimilar metal-alloy welds through energy-resolved neutron imaging is described in this paper. The ability of neutrons to penetrate thick metal objects (up to several cm) provides a unique possibility to examine samples which are opaque to other conventional techniques. The presence of Bragg edges in the measured neutron transmission spectra can be used to characterize the internal residual strain within the samples and some microstructural features, e.g. texture within the grains, while neutron resonance absorption provides the possibility to map the degree of uniformity in mixing of the participating alloys and intermetallic formation within the welds. In addition, voids and other defects can be revealed by the variation of neutron attenuation across the samples. This paper demonstrates the potential of neutron energy-resolved imaging to measure all these characteristics simultaneously in a single experiment with sub-mm spatial resolution. Two dissimilar alloy welds are used in this study: Al autogenously laser welded to steel, and Ti gas metal arc welded (GMAW) to stainless steel using Cu as a filler alloy. The cold metal transfer variant of the GMAW process was used in joining the Ti to the stainless steel in order to minimize the heat input. The distributions of the lattice parameter and texture variation in these welds as well as the presence of voids and defects in the melt region are mapped across the welds. The depth of the thermal front in the Al–steel weld is clearly resolved and could be used to optimize the welding process. As a result, a highly textured structure is revealed in the Ti to stainless steel joint where copper was used as a filler wire. The limited diffusion of Ti into the weld region is also verified by the resonance absorption.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transportable, Low-Dose Active Fast-Neutron Imaging

This document contains a description of the method of transportable, low-dose active fast-neutron imaging as developed by ORNL. The discussion begins with the technique and instrumentation and continues with the image reconstruction and analysis. The analysis discussion includes an example of how a gap smaller than the neutron production spot size and detector size can be detected and characterized depending upon the measurement time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of lithium hydride and its hydrolysis products with neutron imaging

In this study, lithium hydride (LiH) and its hydrolysis products were investigated non-destructively with neutron radiography and neutron computed tomography. Relative neutron transmission intensities (I/I 0 ) were measured for LiOH, Li 2 O and LiH, and their linear attenuation coefficients calculated from this data. We show that 7 Li is necessary for creating large differences in I/I 0 for facile identification of these compounds. The thermal decomposition of LiOH to Li 2 O was also observed with neutron radiography. Computed tomography shows that the samples were fairly homogeneous, with very few macroscopic defects. Lastly, the results shown here demonstrate the feasibility of observing LiH hydrolysis with neutron imaging techniques in real time.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Neutron imaging of diabatic two-phase flows relevant to air conditioning

The design of the evaporator of an air conditioning system relies heavily on heat transfer coefficients and pressure drop correlations that predominantly involve an estimate of the changing void fraction and the underlying two-phase flow regime. These correlations dictate whether the resulting heat exchanger is oversized or not and the amount of refrigerant charge necessary to operate. The latter is particularly important when dealing with flammable or high GWP refrigerants. Traditional techniques to measure the void fraction and visualize the flow are either invasive to the flow or occur downstream of the evaporator, where some of the flow distribution will have changed. Neutron imaging has the potential to visualize two-phase flow in-situ where an aluminium heat exchanger structure becomes essentially transparent to the penetrating neutrons. The subatomic particles are attenuated by the passing refrigerant flow. The resulting image may be directly related to the void fraction and the overall picture provides a clear insight into the flow regime present. This work presents neutron images of the refrigerant Isopentane as it passes through the flow channels of an aluminium evaporator at flowrates relevant to air conditioning. The flow in a 4mm square macro channel is compared to that in a 250 m by 750 m rectangular microchannel in terms of void fraction and regime. All neutron imaging experiments were conducted at the High Flux Isotope Reactor, an Oak Ridge National Laboratory facility

Geoghegan, Patrick J↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron Imaging With Li-Glass Based Multicore SCIntillating FIber (SCIFI)

The improvement of neutron imaging towards and beyond the microscale is a well-documented need for the iterative characterization and modeling of numerous microstructured X-ray opaque materials. This work presents the recent progress in evaluating a SCIntillating FIber (SCIFI) proof-of-concept towards micron-level thermal neutron radiography. These SCIFIs are composed of 6 Li-enriched silicate glass cores doped with a Ce activator. The cores possess ~8.5 μm diameters and ~10 μm pitch following fiber drawing with a cladding glass into an all-solid multicore fiber. A polished 5 mm × 5 mm array of 100 microstructured multicore SCIFI pixels was fabricated into a 1 mm thick faceplate. The neutron efficiency and light yield of the faceplate are characterized as functions of the 7.38 weight percent of Li 2 O, thickness, and the 70% active volume. It was determined that approximately 39% of a thermal neutron (2 Å) beam can be absorbed by the faceplate. The 6 L i ( n , &#x03B1;<!-- α --> ) t reaction is estimated to produce 7,700 ± 1,000 scintillation photons per event, referencing light collection from 241 Am irradiation of the faceplate. Simulations suggest that on average 17.5 ± 1.4% of these photons will be transported to an end of the fiber array for a thermal beam, with at least 7.2% of that total scintillation light being confined into the fiber cores in which it originated. The SCIFI faceplate was integrated into the Neutron Microscope (NM) at the Pulse OverLap DIffractometer (POLDI) beamline located at the Paul Scherrer Institut to image a Siemens star test object. Processed neutron radiographs acquired with the proof-of-concept faceplate resolved features at a state-of-the-art resolution of 16.1 ± 0.5 μm. The potential for even high resolution designs having smaller pitch or different cladding material is discussed.

47 OTHER INSTRUMENTATION↗

Photon-to-Digital Converters for Neutron Imaging Instruments (Final Report)

Oak Ridge National Laboratory (ORNL) collaborated with the Université de Sherbrooke (UdeS) to design a modular and scalable tile of innovative digital photodetectors called Photon-to-Digital Converters (PDC) and the required subsystems to demonstrate the feasibility of large area single-photon detectors to support high-resolution, depth-of-interaction, fast neutron radiography based on scintillation detectors. The goal is to demonstrate the advantages of using PDC over conventional Silicon Photomultiplier (SiPM) for neutron imaging systems. The basic building blocks of analog SiPM and PDC are Single-Photon Avalanche Photodiodes (SPAD). The main difference between conventional SiPMs and PDCs, is in the fact that analog SiPMs sum the charge produced by individual SPAD passively, while in PDCs each SPAD is read out individually by an active electronic circuit. Hence, PDCs provide a direct photon-to-bit conversion where a logic “1” means that there was a detection in a given SPAD. Conversely, an analog SiPM requires a sophisticated preamplifier (current amplifiers or transimpedance amplifier) followed by a shaping amplifier and an analog-to-digital converter. Moreover, since the charge from each SPAD varies slightly, the passive sum of the analog SiPM will have signal fluctuations for the same amount of photon detected. This is one of many issues that is completely eliminated by individual one-to-one SPAD read out in PDCs. The large area required for scintillator readouts for neutron imaging is such that the output capacitance of a large area of SiPM arrays is very high. This creates a burden on the signal-to-noise optimization with respect to the power budget. For PDC, the power consumption is dictated by rate of the incident photon flux, or in photon-starved environments, the dark noise rate of the SPAD array. In other words, the power consumption in the absence of events is extremely low. Hence, the power consumption of a PDC read out system is much lower than its analog counterpart. Further, the large SiPM capacitance may introduce signal distortions on the scintillator fast rise or decay time with undesired effects on timing and pulse shape discrimination. The problem is absent in PDCs, as their readout is independent on device capacitance. UdeS is the world leader in 3D vertical integration of frontside illuminated SPAD arrays over CMOS readouts. These capabilities allow future production of “3D PDC” with maximum photosensitive fill factor and electronic functionalities tailored to the application. UdeS' vast knowledge of SPADs and CMOS design made the team an ideal collaborator in the development of large area high-resolution fast neutron radiography.

42 ENGINEERING↗

A new nonlinear reconstruction method based on total variation regularization of neutron penumbral imaging

Neutron penumbral imaging is a significant diagnostic technique in laser-driven inertial confinement fusion experiment. It is very important to develop a new reconstruction method to improve the resolution of neutron penumbral imaging. A new nonlinear reconstruction method based on total variation (TV) regularization is proposed in this paper. A TV-norm is used as regularized term to construct a smoothing functional for penumbral image reconstruction in the new method, in this way, the problem of penumbral image reconstruction is transformed to the problem of a functional minimization. In addition, a fixed point iteration scheme is introduced to solve the problem of functional minimization. The numerical experimental results show that, compared to linear reconstruction method based on Wiener filter, the TV regularized nonlinear reconstruction method is beneficial to improve the quality of reconstructed image with better performance of noise smoothing and edge preserving. Meanwhile, it can also obtain the spatial resolution with 5 {mu}m which is higher than the Wiener method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring characteristic differences between high- and low-performing discharges on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF

A dense plasma focus (DPF) is a compact coaxial plasma gun, which completes its discharge as a Z-pinch, producing short (<100 ns) pulses of ions, x rays, and/or neutrons. Lawrence Livermore National Laboratory recently constructed and began operating a new device, the MJOLNIR (MegaJOuLe Neutron Imaging Radiography) DPF, which is designed for single-pulse flash neutron radiography. This device has achieved neutron yields of up to 4.1×10 11 neutrons/pulse at 3.3 MA peak current, and higher-current commissioning is under way. Like most DPFs, MJOLNIR exhibits variable yields in some configurations. Here, we present evidence of the role of parasitic current paths within the gun in stochastically influencing the yield. First through “conditioning shots,” where new hardware has been introduced, we show that increased run-down and run-in speeds correlate with higher yields. These observations are consistent with current being delivered to the electrodes but not to the main plasma sheath, degrading the implosion-driving force. Once nominal conditions are established, we correlate low-performing discharges with smaller current dip and associated voltage spike for a fixed machine configuration. A snow-plow model is able to recreate small-magnitude current dips through the introduction of a parasitic current path, and particle-in-cell simulations establish how parasitic current paths lower the ion beam energy available to produce neutrons. Finally, we observe an increased likelihood of shots with low yield and smaller current dip with increasing fill pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deuteron injector for Peking University Neutron Imaging Facility project

The deuteron injector developed for the PKUNIFTY (Peking University Neutron Imaging Facility) has been installed and commissioned at Peking University (PKU). The injector system must transfer 50 keV 50 mA of D{sup +} ion beam to the entrance of the 2 MeV radio frequency quadrupole (RFQ) with 10% duty factor (1 ms, 100 Hz). A compact 2.45 GHz permanent magnet electron cyclotron resonance (PMECR) ion source and a 1.36 m long low energy beam transport (LEBT) line using two solenoids was developed as the deuteron injector. A {phi}5 mm four-quadrant diaphragm was used to simulate the entrance of RFQ electrodes. The beam parameters are measured after this core with an emittance measurement unit (EMU) and a bending magnet for ion fraction analysis at the end of injector. During the commissioning, 77 mA of total deuteron beam was extracted from PMECR and 56 mA of pure D{sup +} beam that passed through the {phi}5 mm four-quadrant diaphragm was obtained at the position of RFQ entrance with the measured normalized rms emittance 0.12-0.16{pi} mm mrad. Ion species analysis results show that the deuteron fraction is as high as 99.5%. All of the parameters satisfy PKUNIFTY's requirements. In this paper, we will describe the deuteron injector design and report the commissioning results as well as the initial operation.

43 PARTICLE ACCELERATORS↗