Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Segmented Ge detectors and mechanical coolers for future gamma-ray astronomy instruments

The effectiveness of a segmented Ge detector in rejecting background events due to the beta decay of internal radioactivity is demonstrated by a laboratory experiment in which radioactivity was produced in the detector by neutron irradiation. A Cf-252 source of neutrons was used to produce, by neutron capture on Ge-74 in the detector itself, Ge-75, which decays by beta emission with a maximum energy of 1188 keV. Simultaneous spectra are taken of the activity in the detector under two conditions: a free spectrum in which all events in the detector are accumulated, and a gated spectrum in which events are accumulated only if they deposit energy in two or more segments. A comparison of the spectra shows that over 85 percent of the beta events are rejected, which is in good agreement with predictions.

Varnell, Larry S.↗

Segmented Ge detector rejection of internal beta activity produced by neutron irradiation

Future Ge spectrometers flown in space to observe cosmic gamma-ray sources will incorporate segmented detectors to reduce the background from radioactivity produced by energetic particle reactions. To demonstrate the effectiveness of a segmented Ge detector in rejecting background events due to the beta decay of internal radioactivity, a laboratory experiment has been carried out in which radioactivity was produced in the detector by neutron irradiation. A Cf-252 source of neutrons was used to produce, by neutron capture on Ge-74 (36.5 percent of natural Ge) in the detector itself, Ge-75 (t sub 1/2 = 82.78 min), which decays by beta emission with a maximum electron kinetic energy of 1188 keV. By requiring that an ionizing event deposit energy in two or more of the five segments of the detector, each about 1-cm thick, the beta particles, which have a range of about 1-mm, are rejected, while most external gamma rays incident on the detector are counted. Analysis of this experiment indicates that over 85 percent of the beta events from the decay of Ge-75 are rejected, which is in good agreement with Monte Carlo calculations.

Varnell, L. S.↗

Ionizing radiation measurements on LDEF: A0015 Free flyer biostack experiment

This report covers the analysis of passive radiation detectors flown as part of the A0015 Free Flyer Biostack on LDEF (Long Duration Exposure Facility). LET (linear energy transfer) spectra and track density measurements were made with CR-39 and Polycarbonate plastic nuclear track detectors. Measurements of total absorbed dose were carried out using Thermoluminescent Detectors. Thermal and resonance neutron dose equivalents were measured with LiF/CR-39 detectors. High energy neutron and proton dose equivalents were measured with fission foil/CR-39 detectors.

Benton, E. V.↗

NASA Tech Briefs, August 2008

Customizable Digital Receivers for Radar Two-Camera Acquisition and Tracking of a Flying Target Visual Data Analysis for Satellites A Data Type for Efficient Representation of Other Data Types Hand-Held Ultrasonic Instrument for Reading Matrix Symbols Broadband Microstrip-to-Coplanar Strip Double-Y Balun A Topographical Lidar System for Terrain-Relative Navigation Programmable Low-Voltage Circuit Breaker and Tester Electronic Switch Arrays for Managing Microbattery Arrays Topics covered include: Lower-Dark-Current, Higher-Blue-Response CMOS Imagers; Fabricating Large-Area Sheets of Single-Layer Graphene by CVD; Support for Diagnosis of Custom Computer Hardware; Providing Goal-Based Autonomy for Commanding a Spacecraft; Dynamic Method for Identifying Collected Sample Mass; Optimal Planning and Problem-Solving; Attitude-Control Algorithm for Minimizing Maneuver Execution Errors; Grants Document-Generation System; Heat-Storage Modules Containing LiNO3 3H2O and Graphite Foam; Precipitation-Strengthened, High-Temperature, High-Force Shape Memory Alloys; Improved Relief Valve Would Be Less Susceptible to Failure; Safety Modification of Cam-and-Groove Hose Coupling; Using Composite Materials in a Cryogenic Pump; Using Electronic Noses to Detect Tumors During Neurosurgery; Producing Newborn Synchronous Mammalian Cells; Smaller, Lower-Power Fast-Neutron Scintillation Detectors; Rotationally Vibrating Electric-Field Mill; Estimating Hardness from the USDC Tool-Bit Temperature Rise; Particle-Charge Spectrometer; Automated Production of Movies on a Cluster of Computers; FIDO-Class Development Rover; and Tone-Based Command of Deep Space Probes Using Ground Antennas.

Source record↗

Spacecraft Status Report: 2001 Mars Odyssey

Fourth extension of Odyssey mission continues, with orbital science investigations and relay services for landed assets. Mitigation of aging IMU and UHF transceiver. ODY has responded to Program Office/board recommendations. All Stellar mode has been certified for flight operations and is now standard for nadir point operations on the A-side. Investigating options to mitigate aging Battery. Gradual transfer to a later LMST orbit node to shorten eclipse durations. Reduce spacecraft loads during the longer eclipses. Optimize battery performance. ODY is preparing for E5 Proposal and Planetary Science Division FY12 Senior Review activities. ODY is on track to support MSL EDL and surface operations. ODY is managing consumables in order to remain in operations until 2020.

inter-annual variations↗

Cosmic and solar gamma ray and neutron experiments

This report summarizes the results of the research supported by NASA grant NAGW-2734 and lists the papers and publications produced through the grant. The basic goal of the work was to complete analysis of data from exposure of a large NaI scintillation detector to fast neutrons and to disseminate the results of the analysis. A secondary goal was to compare the measured detector response to neutrons with Monte Carlo calculations of the response. In Section 2.0, we discuss the goals of the research. In Section 3.0, we summarize the results of the research. In Section 4.0, we list the papers and publications produced under the grant. Preprints or reprints of the publications are attached as appendices.

Dunphy, Philip P.↗

Neutron fluences and energy spectra in the Cosmos-2044 biosatellite orbit

Joint Soviet-American measurements of the neutron component of space radiation (SR) were carried out during the flight of the Soviet biosatellite Cosmos-2044. Neutron flux densities and differential energy spectra were measured inside and on the external surface of the spacecraft. Three energy intervals were employed: thermal (En < or = 0.2 eV), resonance (0.2 eV < En < 1.0 MeV) and fast (En > or = 1.0 MeV) neutrons. The first two groups were measured with U.S. 6LiF detectors, while fast neutrons were recorded both by U.S. fission foils and Soviet nuclear emulsions. Estimations were made of the contributions to absorbed and equivalent doses from each neutron energy interval and a correlation was presented between fast neutron fluxes, measured outside the satellite, and the phase of solar activity (SA). Average dose equivalent rates of 0.018 and 0.14 mrem d-1 were measured for thermal and resonance neutrons, respectively, outside the spacecraft. The corresponding values for fast neutrons were 3.3 (U.S.) and 1.8 (U.S.S.R.) mrem d-1. Inside the spacecraft, a value of 3.5 mrem d-1 was found.

NASA Discipline Number 00-00↗