Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Digital Electronics For The Versatile Array Of Neutron Detectors At Low Energies

A {chi}{sup 2} minimization algorithm has been developed to extract sub-sampling-time information from digitized waveforms, to be used to instrument the future Versatile Array of Neutron Detectors at Low energies. The algorithm performance has been characterized with a fast Arbitrary Function Generator, obtaining time resolution better than 1 ns for signals of amplitudes between 50 mV and 1V, with negligible walk in the whole range. The proof-of-principle measurement of the beta-delayed neutron emission from {sup 89}Br indicates a resolution of 1 ns can be achieved in realistic experimental conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The 3 He BF 3 Giant Barrel (HeBGB) neutron detector

(α,n) reactions play an important role in nuclear astrophysics and applications and are an important background source in neutrino and dark matter detectors. Measurements of total (α,n) cross sections employing direct neutron detection often have a considerable systematic uncertainty associated with the energy-dependent neutron detection efficiency and the unknown initial neutron energy distribution. Furthermore, the 3 He BF 3 Giant Barrel (HeBGB) neutron detector was built at the Edwards Accelerator Laboratory at Ohio University to overcome this challenge. HeBGB offers a near-constant neutron detection efficiency of (7.5 ± 1.2)% over the neutron energy range 0.01 MeV–9.00 MeV, removing a significant source of systematic uncertainty present in earlier (α,n) cross section measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High detection efficiency micro-structured solid-state neutron detector with extremely low leakage current fabricated with continuous p-n junction

We report the continuous p-n junction formation in honeycomb structured Si diode by in situ boron deposition and diffusion process using low pressure chemical vapor deposition for solid-state thermal neutron detection applications. Optimized diffusion temperature of 800 Degree-Sign C was obtained by current density-voltage characteristics for fabricated p{sup +}-n diodes. A very low leakage current density of {approx}2 Multiplication-Sign 10{sup -8} A/cm{sup 2} at -1 V was measured for enriched boron filled honeycomb structured neutron detector with a continuous p{sup +}-n junction. The neutron detection efficiency for a Maxwellian spectrum incident on the face of the detector was measured under zero bias voltage to be {approx}26%. These results are very encouraging for fabrication of large area solid-state neutron detector that could be a viable alternative to {sup 3}He tube based technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of a neutron detector design using adjoint transport simulation

A synthetic aperture approach has been developed and investigated for Special Nuclear Materials (SNM) detection in vehicles passing a checkpoint at highway speeds. SNM is postulated to be stored in a moving vehicle and detector assemblies are placed on the road-side or in chambers embedded below the road surface. Neutron and gamma spectral awareness is important for the detector assembly design besides high efficiencies, so that different SNMs can be detected and identified with various possible shielding settings. The detector assembly design is composed of a CsI gamma-ray detector block and five neutron detector blocks, with peak efficiencies targeting different energy ranges determined by adjoint simulations. In this study, formulations are derived using adjoint transport simulations to estimate detector efficiencies. The formulations is applied to investigate several neutron detector designs for Block IV, which has its peak efficiency in the thermal range, and Block V, designed to maximize the total neutron counts over the entire energy spectrum. Other Blocks detect different neutron energies. All five neutron detector blocks and the gamma-ray block are assembled in both MCNP and deterministic simulation models, with detector responses calculated to validate the fully assembled design using a 30-group library. The simulation results show that the 30-group library, collapsed from an 80-group library using an adjoint-weighting approach with the YGROUP code, significantly reduced the computational cost while maintaining accuracy. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

6:1 aspect ratio silicon pillar based thermal neutron detector filled with {sup 10}B

Current helium-3 tube based thermal neutron detectors have shortcomings in achieving simultaneously high efficiency and low voltage while maintaining adequate fieldability performance. By using a three-dimensional silicon p-i-n diode pillar array filled with boron-10 these constraints can be overcome. The fabricated pillar structured detector reported here is composed of 2 {mu}m diameter silicon pillars with a 4 {mu}m pitch and height of 12 {mu}m. A thermal neutron detection efficiency of 7.3+/-0.6% and a neutron-to-gamma discrimination of 10{sup 5} at 2 V reverse bias were measured for this detector. When scaled to larger aspect ratio, a high efficiency device is possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary analysis of effect of Vanadium Self-Powered Neutron Detectors on AP1000 reactor core physical parameters - 360

For the AP1000 reactor, the Vanadium Self-Powered Neutron Detectors are installed in the instrumentation thimbles of the fuel assembly. The (n,? ) reaction of Vanadium SPNDs will impact on the neutron spectrum of the location, and finally impact on the reactor core physical parameters. But, this effect is not considered for the AP1000 reactor Nuclear Design. So, it is necessary to analyze the effect of the presence of Vanadium SPNDs on the AP1000 reactor core physical parameters. CASMO5 is used to calculate physical parameters of four typical assemblies of AP1000 reactor, and SIMULATE5 is used to calculate physical parameters of the initial cycle. The results show that the maximum absolute deviations of K-infinite, pin power, thermal flux for the assemblies are 181 pcm, 6.3% and 20.1%, separately. The maximum absolute deviations of critical boron concentration, heat flux hot channel factor, nuclear enthalpy rise hot channel factor, axial offset, quadrant power tilt ratio and axial power distribution of the initial cycle are 5 ppm, 0.7%, 0.5%, 0.1%,0.09% and 0.19%,separately. So, the presence of Vanadium SPNDs has a significant impact on the power distribution of pin cells around the instrumentation thimble and the thermal flux in the location of instrumentation thimble, but doesn't affect core physical parameters of the initial cycle very much. As is shown, it is very important to accurately consider the effect of presence of Vanadium SPNDs when calculating the Vanadium SPNDs current response. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Non-streaming high-efficiency perforated semiconductor neutron detectors, methods of making same and measuring wand and detector modules utilizing same

Non-streaming high-efficiency perforated semiconductor neutron detectors, method of making same and measuring wands and detector modules utilizing same are disclosed. The detectors have improved mechanical structure, flattened angular detector responses, and reduced leakage current. A plurality of such detectors can be assembled into imaging arrays, and can be used for neutron radiography, remote neutron sensing, cold neutron imaging, SNM monitoring, and various other applications.

McGregor, Douglas S↗

The All Boron Carbide Diode Neutron Detector: Experiment and Modeling Approach

Boron carbide diode detectors, fabricated from two different polytypes of semiconducting boron carbide, will detect neutrons in reasonable agreement with theoretical expectations. The performance of the all boron carbide neutron detector differs, as expected, from devices where a boron rich neutron capture layer is distinct from the diode charge collection region (i.e. a conversion layer solid state detector). Diodes were fabricated from natural abundance boron (20% {sup 10}B and 80% {sup 11}B.) directly on the metal substrates and metal contacts applied to the films as grown. The total boron depth was on the order of 2 microns. This is clearly not a conversion-layer configuration. The diodes were exposed to thermal neutrons generated from a paraffin moderated plutonium-beryllium source in moderated and un-moderated, as well as shielded and unshielded experimental configurations, where the expected energy peaks at at 2.31 MeV and 2.8 MeV were clearly observed, albeit with some incomplete charge collection typical of thinner diode structures. The results are compared with other boron based thin film detectors and literature models. (authors)

36 MATERIALS SCIENCE↗

Absolute Efficiency Characterization of Neutron Detectors within Radioisotope Identification Devices [Slides]

Some Radioisotope Identification Devices (RIIDs) have a low efficiency neutron detector that can provide a neutron singles counting rate along with the primary gamma spectra that can be used to identify a radioisotope. When we know absolute efficiency, other characteristics of a radioisotope can be estimated such as mass or source strength when accompanied by the identity of the isotope and other observable variables. This study focuses on characterizing and comparing the absolute neutron efficiencies of some commonly used RIIDs: the ORTEC Detective X, ORTEC RADEAGLET-R, and FLIR IDentifinder 2.

Nuclear Criticality Safety Program (NCSP)↗

Status of h-BN quasi-bulk crystals and high efficiency neutron detectors

III-nitrides have fomented a revolution in the lighting industry and are poised to make a huge impact in the field of power electronics. In the III-nitride family, the crystal growth and use of hexagonal BN (h-BN) as an ultrawide bandgap (UWBG) semiconductor are much less developed. Bulk crystals of h-BN produced by the high-temperature/high-pressure and the metal flux solution methods possess very high crystalline and optical qualities but are impractical to serve as substrates or for device implementation as their sizes are typically in millimeters. The development of crystal growth technologies for producing thick epitaxial films (or quasi-bulk or semi-bulk crystals) in large wafer sizes with high crystalline quality is a prerequisite for utilizing h-BN as an UWBG electronic material. Compared to traditional III-nitrides, BN has another unique application as solid-state neutron detectors, which however, also require the development of quasi-bulk crystals to provide high detection efficiencies because the theoretical efficiency (ηi) relates to the detector thickness (d) by ηi=1−e−dλ, where λ denotes the thermal neutron absorption length which is 47 μm (237 μm) for 10B-enriched (natural) h-BN. We provide an overview and recent progress toward the development of h-BN quasi-bulk crystals via hydride vapor phase epitaxy (HVPE) growth and the attainment of thermal neutron detectors based on 100 μm thick 10B-enriched h-BN with a record efficiency of 60%. The thermal neutron detection efficiency was shown to enhance at elevated temperatures. Benchmarking the crystalline and optical qualities of h-BN quasi-bulk crystals with the state-of-the-art mm-sized bulk crystal flakes and 0.5 μm thick epitaxial films identified that reducing the density of native defects such as vacancies remains the most critical task for h-BN quasi-bulk crystal growth by HVPE.

Physics↗

Development of a lithium-glass based composite neutron detector for 3 He replacement

We are fabricating two Li-glass based composite neutron detectors, cylindrical in shape (one 2” in diameter, 3” in height and another 5” by 5”), made of dye-loaded polyvinyltoluene embedded with 1.5-mm lithium-glass cubes composing 7% of the total mass. Initial simulation results of a 252 Cf source suggest that the 2” x 3” and 5” x 5” detectors will be roughly 1% and 10% efficient, respectively, for detection of unmoderated fission neutrons. Experimental evaluation of the detectors will be carried out in late summer 2012.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Self-powered micro-structured solid state neutron detector with very low leakage current and high efficiency

We report on the design, fabrication, and performance of solid-state neutron detector based on three-dimensional honeycomb-like silicon micro-structures. The fabricated detectors use boron filled deep holes with aspect ratio of over 12 and showed a very low leakage current density of {approx}7 Multiplication-Sign 10{sup -7} A/cm{sup 2} at -1 V for device sizes varying from 2 Multiplication-Sign 2 to 5 Multiplication-Sign 5 mm{sup 2}. A thermal neutron detection efficiency of 4.5% {+-} 0.5% with discrimination setting of 500 keV and gamma to neutron sensitivity of (1.1 {+-} 0.1) Multiplication-Sign 10{sup -5} for single layer was measured without external bias for these devices. Monte-Carlo simulation predicts a maximum efficiency of 45% for such devices filled with 95% enriched {sup 10}boron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Neutron Detectors with Discrete Anode Pad Readout

A new two-dimensional thermal neutron detector concept that is capable of very high rates is being developed. It is based on neutron conversion in {sup 3}He in an ionization chamber (unity gas gain) that uses only a cathode and anode plane; there is no additional electrode such as a Frisch grid. The cathode is simply the entrance window, and the anode plane is composed of discrete pads, each with their own readout electronics implemented via application specific integrated circuits. The aim is to provide a new generation of detectors with key characteristics that are superior to existing techniques, such as higher count rate capability, better stability, lower sensitivity to background radiation, and more flexible geometries. Such capabilities will improve the performance of neutron scattering instruments at major neutron user facilities. In this paper, we report on progress with the development of a prototype device that has 48 x 48 anode pads and a sensitive area of 24cm x 24cm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absolute calibration of neutron detectors on the C-2U advanced beam-driven FRC

In the C-2U fusion energy experiment, high power neutral beam injection creates a large fast ion population that sustains a field-reversed configuration (FRC) plasma. The diagnosis of the fast ion pressure in these high-performance plasmas is therefore critical, and the measurement of the flux of neutrons from the deuterium-deuterium (D-D) fusion reaction is well suited to the task. Here we describe the absolute, in situ calibration of scintillation neutron detectors via two independent methods: firing deuterium beams into a high density gas target and calibration with a 2 × 10{sup 7} n/s AmBe source. The practical issues of each method are discussed and the resulting calibration factors are shown to be in good agreement. Finally, the calibration factor is applied to C-2U experimental data where the measured neutron rate is found to exceed the classical expectation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

6Li foil thermal neutron detector

In this paper we report on the design of a multilayer thermal neutron detector based on {sup 6}Li reactive foil and thin film plastic scintillators. The {sup 6}Li foils have about twice the intrinsic efficiency of {sup 10}B films and about four times higher light output due to a unique combination of high energy of reaction particles, low self absorption, and low ionization density of tritons. The design configuration provides for double sided readout of the lithium foil resulting in a doubling of the efficiency relative to a classical reactive film detector and generating a pulse height distribution with a valley between neutron and gamma signals similar to {sup 3}He tubes. The tens of microns thickness of plastic scintillator limits the energy deposited by gamma rays, which provides the necessary neutron/gamma discrimination. We used MCNPX to model a multilayer Li foil detector design and compared it with the standard HLNCC-II (18 {sup 3}He tubes operated at 4 atm). The preliminary results of the {sup 6}Li configuration show higher efficiency and one third of the die-away time. These properties, combined with the very short dead time of the plastic scintillator, offer the potential of a very high performance detector.

36 MATERIALS SCIENCE↗

On a neutron detector based on TlInSe{sub 2} crystals intercalated with a lithium isotope

The possibility of increasing the sensitivity of a neutron detector based on a TlInSe{sub 2} crystal by introducing the {sup 6}Li isotope into this crystal is investigated. Introduction of the isotope is conducted by the method of electrochemical intercalation from aqueous and nonaqueous solutions of LiCl and also from the melt of the LiCl–KCl eutectic. It is shown that intercalation by the electrochemical method from a LiCl solution in propylene carbonate, performed along the “c” axis of the crystal (along strong bond chains) is efficient. The attained concentration of introduced lithium amounts to (1–1.2) × 10{sup 21} cm{sup –3}, which increased the sensitivity of the detector by approximately four times. Good agreement between the calculated and experimental values of the detector sensitivity is demonstrated.

36 MATERIALS SCIENCE↗