Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NUCLEAR FRAGMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Recent measurements for hadrontherapy and space radiation: nuclear physics

The particles and energies commonly used for hadron therapy overlap the low end of the charge and energy range of greatest interest for space radiation applications, Z=1-26 and approximately 100-1000 MeV/nucleon. It has been known for some time that the nuclear interactions of the incident ions must be taken into account both in treatment planning and in understanding and addressing the effects of galactic cosmic ray ions on humans in space. Until relatively recently, most of the studies of nuclear fragmentation and transport in matter were driven by the interests of the nuclear physics and later, the hadron therapy communities. However, the experimental and theoretical methods and the accelerator facilities developed for use in heavy ion nuclear physics are directly applicable to radiotherapy and space radiation studies. I will briefly review relevant data taken recently at various accelerators, and discuss the implications of the measurements for radiotherapy, radiobiology and space radiation research.

NASA Discipline Radiation Health↗

Helium ions for radiotherapy? Physical and biological verifications of a novel treatment modality

Purpose: Modern facilities for actively scanned ion beam radiotherapy allow in principle the use of helium beams, which could present specific advantages, especially for pediatric tumors. In order to assess the potential use of these beams for radiotherapy, i.e., to create realistic treatment plans, the authors set up a dedicated {sup 4}He beam model, providing base data for their treatment planning system TRiP98, and they have reported that in this work together with its physical and biological validations. Methods: A semiempirical beam model for the physical depth dose deposition and the production of nuclear fragments was developed and introduced in TRiP98. For the biological effect calculations the last version of the local effect model was used. The model predictions were experimentally verified at the HIT facility. The primary beam attenuation and the characteristics of secondary charged particles at various depth in water were investigated using {sup 4}He ion beams of 200 MeV/u. The nuclear charge of secondary fragments was identified using a ΔE/E telescope. 3D absorbed dose distributions were measured with pin point ionization chambers and the biological dosimetry experiments were realized irradiating a Chinese hamster ovary cells stack arranged in an extended target. Results: The few experimental data available on basic physical processes are reproduced by their beam model. The experimental verification of absorbed dose distributions in extended target volumes yields an overall agreement, with a slight underestimation of the lateral spread. Cell survival along a 4 cm extended target is reproduced with remarkable accuracy. Conclusions: The authors presented a simple simulation model for therapeutical {sup 4}He beams which they introduced in TRiP98, and which is validated experimentally by means of physical and biological dosimetries. Thus, it is now possible to perform detailed treatment planning studies with {sup 4}He beams, either exclusively or in combination with other ion modalities.

60 APPLIED LIFE SCIENCES↗

Silicon Detector System for Cross Section Measurements

In order to estimate the radiation shielding effectiveness of materials it is necessary to know cosmic ray particles are broken up as they pass though these materials. The breakup of cosmic ray particles is characterized by the nuclear fragmentation cross sections, i.e. an effective geometrical cross section assigned to each target nucleus that represents its apparent size for fragmenting the incident particle. The values of these cross sections depend on the details of nuclear physics and cannot be calculated from first principles owing to the many-body nature of the interactions. The only way to determine them is to measure them. Once a sufficient number of cross sections have been measured, the systematic nature of the interactions allows other cross-sections to be estimated. The number of cross sections that contribute to the estimation of shielding effectiveness is very large 10,000. Fortunately most make minor contributions. These can be estimated from nuclear systematics. Only those who's uncertainties make significant contributions to the error in the shielding effectiveness estimations need to be measured. In the past it has proven difficult to measure light fragment production cross sections from the interactions of heavy cosmic rays owing to the size of the detectors used. We have developed a highly pixilated silicon (Si) detector system that can individually identify these light fragments while making efficient use of costly accelerator time. This system is an outgrowth of detector technology developed under a CDDF and a Code S sponsored cosmic ray experiment.

Source record↗

HZETRN: neutron and proton production in quasi-elastic scattering of GCR heavy-ions

The development of transport models for radiation shielding design and evaluation has provided a series of deterministic computer codes that describe galactic cosmic radiation (GCR), solar particle events, and experimental beams at particle accelerators. These codes continue to be modified to accommodate new theory and improvements to the particle interaction database (Cucinotta et al., 1994, NASA Technical Paper 3472, US Government Printing Office, Washington DC). The solution employed by the heavy-ion transport code HZETRN was derived with the assumption that nuclear fragments are emitted with the same velocity as the incident ion through velocity conserving nuclear interactions. This paper presents a version of the HZETRN transport code that provides a more realistic distribution of the energy of protons and neutrons emitted from GCR interactions in shields. This study shows that the expected GCR dose equivalent is lower than previously calculated for water shields that are less than 110 g cm-2 thick. Calculations of neutron energy spectra in low Earth orbit indicate substantial contributions from relativistic neutrons. c2001 Elsevier Science Ltd. All rights reseved.

NASA Center LaRC↗

Description of Light Ion Production Cross Sections and Fluxes on the Mars Surface using the QMSFRG Model

The atmosphere of Mars significantly attenuates the heavy ion component of the primary galactic cosmic rays (GCR), however increases the fluence of secondary light ions (neutrons, and hydrogen and helium isotopes) because of particle production processes. We describe results of the quantum multiple scattering fragmentation (QMSFRG) model for the production of light nuclei through the distinct mechanisms of nuclear abrasion and ablation, coalescence, and cluster knockout. The QMSFRG model is shown to be in excellent agreement with available experimental data for nuclear fragmentation cross sections. We use the QMSFRG model and the space radiation transport code, HZETRN to make predictions of the light particle environment on the Martian surface at solar minimum and maximum. The radiation assessment detector (RAD) experiment will be launched in 2009 as part of the Mars Science Laboratory (MSL). We make predictions of the expected results for time dependent count-rates to be observed by RAD experiment. Finally, we consider sensitivity assessments of the impact of the Martian atmospheric composition on particle fluxes at the surface.

Cucinotta, Francis A.↗

Comparisons of Integrated Radiation Transport Models with Microdosimetry Data in Spaceflight

Astronauts are exposed to galactic cosmic rays (GCR), trapped protons, and possible solar particle events (SPE) during spaceflight. For such complicated mixtures of radiation types and kinetic energies, tissue equivalent proportional counters (TEPC's) represent a simple time-dependent approach for radiation monitoring. Of interest in radiation protection is the average quality factor of a radiation field defined as a function of linear energy transfer, LET, Q(sub ave)(LET). However TEPC's measure the average quality factors as a function of lineal energy (y), Q(sub ave)(y) defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector. Using integrated space radiation models that includes the transport code HZETRN/BRYNTRN, the quantum nuclear interaction model, QMSFRG, and results from Monte-Carlo track simulations of TEPC's response to ions, we consider comparisons of model calculations to TEPC results from NASA missions in low Earth orbit and make predictions for lunar and Mars missions. Good agreement between the model and measured spectra from past NASA missions is found. A finding of this work is that TEPC's values for trapped or solar protons of Q(sub ave)(y) range from 1.9-2.5, overestimating Q(sub ave)(LET), which ranges from 1.4-1.6 with both quantities increasing with shielding depth due to nuclear secondaries Comparisons for the complete GCR spectra show that Q(sub ave)(LET) for GCR is approximately 3.5-4.5, while TEPC's measure 2.9-3.4 for Q(sub ave)(y) with the GCR values decreasing with depth as heavy ions are absorbed in shielding material. Our results support the use of TEPC's for space radiation environmental monitoring when computational analysis is used for proper data interpretation.

Cucinotta, Francis A.↗

Spent Fuel Ratio Estimates from Numerical Models in ALE3D

Potential threat of intentional sabotage of spent nuclear fuel storage facilities is of significant importance to national security. Paramount is the study of focused energy attacks on these materials and the potential release of aerosolized hazardous particulates into the environment. Depleted uranium oxide (DUO 2 ) is often chosen as a surrogate material for testing due to the unreasonable cost and safety demands for conducting full-scale tests with real spent nuclear fuel. To account for differences in mechanical response resulting in changes to particle distribution it is necessary to scale the DUO 2 results to get a proper measure for spent fuel. This is accomplished with the spent fuel ratio (SFR), the ratio of respirable aerosol mass released due to identical damage conditions between a spent fuel and a surrogate material like depleted uranium oxide (DUO 2 ). A very limited number of full-scale experiments have been carried out to capture this data, and the oft-questioned validity of the results typically leads to overly-conservative risk estimates. In the present work, the ALE3D hydrocode is used to simulate DUO 2 and spent nuclear fuel pellets impacted by metal jets. The results demonstrate an alternative approach to estimate the respirable release fraction of fragmented nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Spallation reactions induced by 4.4 GeV deuterons on lead isotopes

Independent and cumulative production cross sections for radioactive nuclear fragments from the deuteron-irradiation of isotopically enriched lead (204Pb, 206Pb, 207Pb, and 208Pb) targets were obtained for the first time. The experiment has been performed with a 4.4 GeV deuteron beam from the Nuclotron of the Laboratory of High Energy Physics (LHE), Joint Institute for Nuclear Research (JINR) at Dubna. The production cross sections of target fragments were determined by off-line γ-ray spectroscopy. Charge dispersion and mass-yield distributions were deduced from these data. The results are discussed in terms of the relative importance of different reaction mechanisms (evaporation–spallation, fission and multifragmentation). Comparison of our results with the data from the reaction induced by protons of about the same kinetic energy per nucleon, has been performed. The coexistence of the different decay modes in the formation of the reaction residues, such as spallation, fission and multifragmentation is suggested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Physics and Hadron Therapy

Hadron therapy uses light charged particles beams (mainly proton and {sup 12}C ions) to irradiate tumors. These beams present a ballistic advantage with a maximum energy deposition at the end of the path. A large dose can be delivered inside a deep tumor while the surrounding healthy tissues are preserved. There is an obvious advantage in using these beams but the beam control has to be achieved and all the physical processes leading to the energy deposition have to be fully under control. This treatment protocol requires accurate control devices and a good knowledge of the physical processes occurring all along the path of the projectile in human tissues. In this report, we will present one example of a beam monitor for the proton therapy. We will also present the experimental program which has been initiated to obtain fundamental data on the nuclear fragmentation process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gravisensing, apoptosis, and drug recovery in Taxus cell suspensions

Haploid and diploid cell suspensions of Taxus spp. were examined for their adaptive plasticity in response to simulated microgravity, unit gravity, and hypergravity. Cell suspensions produced the taxane, paclitaxel, (TAXOL (R)), which is useful for the treatment of various cancers. Amyloplasts contributed to taxane ring biosynthesis and to drug release at the cell wall. Drug-producing cells reacted as gravisensing osmotic tensiometers. In stressed cells, amyloplasts docked and fused in clusters to sites on the plasmalemma before taxane discharge into the culture medium. In simulated microgravity and compared to all other treatments, taxane production was reduced nearly 100-fold. The percent paclitaxel of total taxanes remained 3-to 6-fold greater, and biomass doubled. When p53-independent programmed cell death was induced, taxanes were released into the culture medium as free molecules (soluble and insoluble) or bound to membranes, nuclear fragments, xylan residues, and other particulate materials. Unit gravity and especially hypergravity promoted xylogenesis and significant drug overproduction. A model relating families of >touch = (TCH), taxane early response (TER), nuclear cycling, and apoptosis-regulating genes to gravisensing, cell wall modifications, and to taxane recovery accounted for most but not all of the observations.

Paclitaxel/biosynthesis↗

Measurement of directed flow in Au + Au collisions at $\sqrt{s{NN}}$ = 19.6 and 27 GeV with the STAR event plane detector

In heavy-ion collision experiments, the global collectivity of final-state particles can be quantified by anisotropic flow coefficients (𝑣 𝑛 ) . The first-order flow coefficient, also referred to as the directed flow (𝑣 1 ), describes the collective sideward motion of produced particles and nuclear fragments in heavy-ion collisions. It carries information on the very early stage of the collision, especially at large pseudorapidity (𝜂), where it is believed to be generated during the nuclear passage time. Directed flow therefore probes the onset of bulk collective dynamics during thermalization, providing valuable experimental guidance to models of the pre-equilibrium stage. In 2018, the Event Plane Detector (EPD) was installed in STAR and used for the Beam Energy Scan phase-II (BES-II) data taking. The combination of EPD (2.1 < |𝜂| < 5.1) and high-statistics BES-II data enables us to extend the 𝑣 1 measurement to the forward and backward 𝜂 regions. In this paper, we present the measurement of 𝑣 1 over a wide 𝜂 range in Au + Au collisions at $\sqrt{s_{NN}}$ = 19.6 and 27 GeV using the STAR EPD. The results of the analysis at $\sqrt{s_{NN}}$ = 19.6 GeV exhibit excellent consistency with the previous PHOBOS measurement, while elevating the precision of the overall measurement. The increased precision of the measurement also revealed finer structures in heavy-ion collisions, including a potential observation of the first-order event-plane decorrelation. Multiple physics models were compared to the experimental results. Only a transport model and a three-fluid hybrid model can reproduce a sizable 𝑣 1 at large 𝜂 as was observed experimentally. The model comparison also indicates 𝑣 1 at large 𝜂 might be sensitive to the QGP phase transition.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiment Design of Secondary Neutron and Charged Particles Measurement with Stopping Targets Bombarded by 100- and 230-MeV/amu Helium Ions - Paper 124

Radiotherapy using ion beams has gained momentum in radiation oncology. While the number of proton therapy facilities that have been established or are under construction is rapidly growing, interest in heavy ion (whose atomic number Z is greater than one) radiotherapy has also been revitalized in the U.S. Helium ions, with mass and charge between protons and carbon ions, have advantages of deep penetration distances with significant peak-to-entrance dose ratios and limited dose contributions from secondary neutrons and other secondary charged fragments. In consideration of these advantages, the U.S. ion beam therapy community has expressed interests in helium ions as a potential candidate for ion beam therapy, especially pediatric cases. As such, characterizing the secondary nuclear fragment field created by primary helium ion interactions along the beam delivery devices and in human tissue is important for dose assessment and patient protection. Up to now the experimental data with respect to helium ions over the therapeutic energy range, 100 - 230 MeV/amu, is scarce compared to protons and carbon ions. Kurosawa et al. measured stopping target yields and angular spectra of neutrons, protons, deuterons and tritons produced by various target materials bombarded by 100- and 180- MeV/amu helium ions; Heilbronn et al. and Cecil et al. also measured the stopping target neutron yields by 155-, 160- and 177.5-MeV/amu helium ion bombardments. We have proposed to measure angular distributions of secondary neutrons and light charged ions produced by 100- and 230-MeV/amu helium ions bombarding stopping water and iron targets. The experiment was conducted at the Heavy Ion Medical Accelerator in Chiba (HIMAC) of the National Institute of Radiological Sciences (NIRS) in Japan this June. During the literature survey for experimental setup, we found that the ratio of the ion beam range (R) to the target depth (d) varies from 0.5 - 0.98 in the stopping target measurements either for helium ions incident on various targets or carbon ions bombarding targets as tissue surrogates. The difference in the values of ratio R/d makes comparison of experimental results complicated and require accurate corrections. Hence, how the R/d ratio and cross sectional area of the targets influence the angular distributions of secondary particles is investigated by using a Monte Carlo method in this study. The influence of the depth and the cross sectional area of stopping water and iron targets on the yield and the spectra of secondary particles induced by 100- and 230-MeV/amu He ions was studied by a Monte Carlo simulation code, PHITS. The secondary charged particles and secondary neutrons who come from breakup of projectiles are highly forward-focused, while the secondary particles produced by target breakup are nearly isotropic. As the energy of {sup 4}He ions increases from 100 MeV/amu to 230 MeV/amu, the normalized intensities of charged particles decrease more gently with increasing angles, whereas the neutron angular distribution falls quickly at angles smaller than 30 deg. and starts to exceed the normalized profile of 100 MeV/amu He from 60 deg. When the target depth increases, the impact on attenuation of secondary particles is more significant for lighter target mass and higher-energy projectiles at forward angles. Also, with deeper targets, more interactions occur between the secondary particles and the target elements, which results in more target-like fragments at large and backward angles. In respect of the cross sectional area of the stopping targets, the forward angular distributions are similar to the system with smaller cross sectional area of the targets; however, no general rule was found for how the large-angle distributions are affected by the target cross sectional area. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Validation of Geant4 fragmentation for Heavy Ion Therapy

12 C ion therapy has had growing interest in recent years for its excellent dose conformity. However at therapeutic energies, which can be as high as 400 MeV/u, carbon ions produce secondary fragments. For an incident 400 MeV/u 12 C ion beam, ~70% of the beam will undergo fragmentation before the Bragg Peak. The dosimetric and radiobiological impact of these fragments must be accurately characterised, as it can result in increasing the risk of secondary cancer for the patient as well as altering the relative biological effectiveness. Here, this work investigates the accuracy of three different nuclear fragmentation models available in the Monte Carlo Toolkit Geant4, the Binary Intranuclear Cascade (BIC), the Quantum Molecular Dynamics (QMD) and the Liege Intranuclear Cascade (INCL++). The models were benchmarked against experimental data for a pristine 400 MeV/u 12 C beam incident upon a water phantom, including fragment yield, angular and energy distribution. For fragment yields the three alternative models agreed between ~5 and ~35% with experimental measurements, the QMD using the “Frag” option gave the best agreement for lighter fragments but had reduced agreement for larger fragments. For angular distributions INCL++ was seen to provide the best agreement among the models for all elements with the exception of Hydrogen, while BIC and QMD was seen to produce broader distributions compared to experiment. BIC and QMD performed similar to one another for kinetic energy distributions while INCL++ suffered from producing lower energy distributions compared to the other models and experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How Space Radiation Risk from Galactic Cosmic Rays at the International Space Station Relates to Nuclear Cross Sections

Space radiation risk to astronauts is a major obstacle for long term human space explorations. Space radiation transport codes have thus been developed to evaluate radiation effects at the International Space Station (ISS) and in missions to the Moon or Mars. We study how nuclear fragmentation processes in such radiation transport affect predictions on the radiation risk from galactic cosmic rays. Taking into account effects of the geomagnetic field on the cosmic ray spectra, we investigate the effects of fragmentation cross sections at different energies on the radiation risk (represented by dose-equivalent) from galactic cosmic rays behind typical spacecraft materials. These results tell us how the radiation risk at the ISS is related to nuclear cross sections at different energies, and consequently how to most efficiently reduce the physical uncertainty in our predictions on the radiation risk at the ISS.

Lin, Zi-Wei↗

Slicing Pomerons in ultraperipheral collisions using forward neutrons from nuclear breakup

We argue that measurements of forward neutrons from nuclear breakup in inclusive high energy photon-nucleus ( γ A ) scattering provide a novel way to study small- x dynamics of QCD in heavy-ion ultraperipheral collisions (UPCs). Using models for hadronic fluctuations of the real photon and neutron emission in nuclear fragmentation, we calculate the distribution over the number of evaporation neutrons produced in γ Pb collisions at the Large Hadron Collider. We show that it is correlated with the number of wounded nucleons (inelastic collisions) and, hence, can constrain the mechanism of nuclear shadowing and its x dependence. Published by the American Physical Society 2024

Physics↗

The fragmentation of 510 MeV/nucleon iron-56 in polyethylene. II. Comparisons between data and a model

The results of a Monte Carlo model for calculating fragment fluences and LET spectra are compared to data taken with 600 MeV/nucleon iron ions incident on an accelerator beamline configured for irradiation of biological samples, with no target and with 2, 5 and 8 cm of polyethylene. The model uses a multi-generation nuclear fragmentation code, coupled with a formulation of ionization energy loss based on the Bethe-Bloch equation. In the region where the data are reliable and the experimental acceptance is well understood, many of the features of the experimental spectra are well replicated by the model. To obtain good agreement with the experimental data, the model must allow for at least two generations of fragment production in the target.

NASA Discipline Number 99-99↗

Isotopic temperature in spallation reactions

The possibility of applying the double-isotope-ratio method for calculating temperature to spallation products formed by high-energy protons is discussed. It is concluded that, at a specific incident-particle energy, spallation is characterized by a single temperature of the formation of products for targets in the mass range 56 {<=} A {<=} 208. No energy dependence of the temperature that was calculated by the double-isotope-ratio method was observed in the energy range 0.3 {<=} E {<=} 300 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗