Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NONMETALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

History of NASA’s Odor Assessment (Test 6)

NASA's Odor Assessment (Test 6) for nonmetallic materials and assembled articles for spacecraft has evolved since the Apollo program in 1966 to meet various habitable spacecraft nonmetallic programmatic requirements. The purpose of Test 6 is to determine if the odor from a material or assembled article is objectionable or revolting on an odor-characteristic scale of 0 to 4. Samples of the toxicity-screened test atmosphere from a conditioned specimen container are administered to an Odor Panel of qualified human research subject volunteers using a syringe and mask, and are assigned a scored odor characteristic of undetectable (0), barely detectable (1), easily detectable (2), objectionable (3), or revolting (4). The odor from a material or assembled article is objectionable or revolting if an average rating of 2.5 or higher is assigned by an Odor Panel. This manuscript presents the history of Test 6, beginning with the Apollo spacecraft nonmetallic materials selection guidelines and test requirements from 1966, in which tests were performed in oxygen atmospheres, and follows the odor test through Skylab, Space Shuttle, International Space Station, and Orion nonmetals testing, and acceptance requirements.

Benjamin Greene↗

Optical Pathlength Control Experiment on JPL Phase B Testbed

An experimental implementation of a nanometer level optical pathlength control for large baseline space interferometry is presented. The pathlength compensation system is installed on a large flexible experimental truss, thus structural motions play a dominant role in the control system design. The associated control structure interaction problem is addressed to maintain the optical pathlength within the prescribed variation of 10-15 nanometer rms. By a successful blend of a structural control for damping augmentation and a direct pathlength control for the pathlength compensation, the optical pathlength variation has been maintained within 6 nonometer rms under the laboratory ambient disturbance and within 9 nonmeter rms under a severe forced resonant disturbance.

interferometry↗

Preliminary Investigation of Fretting

An experimental investigation, using microscopic observation and color motion photomicrographs of the action, was conducted to determine the cause of fretting. Glass and other noncorrosive materials, as well as metals, were used as specimens. A very simple apparatus vibrated convex surfaces in contact with stationary flat surfaces at frequencies of 120 cycles or less than one cycle per second, an amplitude of 0.001 inch, and a load of 0.2 pound. The observations and analysis led to the conclusions that fretting was initiated by the loosening, due to the inherent adhesive forces, of finely divided and apparently virgin material, and that its initiation is independent of vibratory motion or high sliding speeds. The fretting of platinum, glass, quartz, ruby, and mica relegated the role of oxidation as a cause to that of a secondary factor. Fretting occurred to clean nonmetals and metals readily, and glass microscope slides and steel balls provide excellent method for visual studies. Video run time 9:54, color and sound (mp4). Available for download for best viewing. Document indicated in video is related in the repository and can also be downloaded for use at https://ntrs.nasa.gov/citations/19930083206.

fretting↗

Co-doped titanium oxide foam and water disinfection device

A quaternary oxide foam, comprises an open-cell foam containing (a) a dopant metal, (b) a dopant nonmetal, (c) titanium, and (d) oxygen. The foam has the advantages of a high surface area and a low back pressure during dynamic flow applications. The inactivation of Escherichia coli (E. coli) was demonstrated in a simple photoreactor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and Expansion of Research Facilities to Address the Challenges of the Nuclear Industry - 16055

With the wide variety of challenges that surround nuclear decommissioning, bespoke facilities are required to undertake experiments which can inform decision making. Here we describe research carried out at The University of Manchester's Dalton Cumbrian Facility, a custom built research environment which incorporates a 5 MV ion accelerator as well as a self-shielded {sup 60}Co irradiator. The ion accelerator allows the investigation in to the radiolytic consequences of various charged particles, including protons, alpha particles and a variety of heavier (metal and nonmetal) ions, while the {sup 60}Co irradiator allows the effects of gamma radiation to be studied. We provide specific research examples that demonstrate how this equipment can improve our mechanistic understanding of various aspects of the deleterious effects of radiation in the nuclear industry. These examples include applications in waste encapsulation as well as geological disposal and novel surveying techniques. The outlook for future research and expansion of the facility is also presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stent Implantation for Malignant Pulmonary Artery Stenosis in a Metastasizing Non-Small Cell Bronchial Carcinoma

A 58-year-old patient with recently diagnosed non-small cell bronchial carcinoma was referred to us with increasing shortness of breath and orthopnea by her family practitioner. To exclude the possibility of a pulmonary embolism, contrast medium-enhanced angio-CT of the thorax was performed. This showed a large mediastinal tumor, which, on the one hand, infiltrated and occluded the left upper lobe bronchus and, on the other, constricted the left pulmonary artery over a considerable part of its length. In view of the palliative situation and massively increasing dyspnea, balloon dilatation of the obstructed left pulmonary artery followed by stent placement was performed. This resulted in an immediate improvement of the symptoms. The originally strongly oxygen-dependent and heavily dyspneic patient could be relieved of the external supply of oxygen and was able to sleep normally without additional medication within 24 h. The patient was able ambulate freely within 2 days, with a markedly improved quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Different Vein Catheter Sizes for Mechanical Power Injection in CT: In Vitro Evaluation with Use of a Circulation Phantom

The purpose of this study was to evaluate the influence of different peripheral vein catheter sizes on the injection pressure, flow rate, injection duration, and intravascular contrast enhancement. A flow phantom with a low-pressure venous compartment and a high-pressure arterial compartment simulating physiological circulation parameters was used. High-iodine-concentration contrast medium (370 mg iodine/ml; Ultravist 370) was administered in the venous compartment through peripheral vein catheters of different sizes (14, 16, 18, 20, 22, and 24 G) using a double-head power injector with a pressure limit of 325 psi. The flow rate was set to 5 ml/s, with a total iodine load of 36 g for all protocols. Serial CT scans at the level of the pulmonary artery and the ascending and the descending aorta replica were obtained. The true injection flow rate, injection pressure, injection duration, true contrast material volume, and pressure in the phantom during and after injection were continuously monitored. Time enhancement curves were computed and both pulmonary and aortic peak time and peak enhancement were determined. Using peripheral vein catheters with sizes of 14-20 G, flow rates of approximately 5 ml/s were obtained. During injection through a 22-G catheter the pressure limit was reached and the flow rate was decreased, with a consecutive decreased pulmonary and aortic contrast enhancement compared to the 14- to 20-G catheters. Injection through a 24-G peripheral vein catheter was not possible because of disconnection of the canula due to the high flow rate and pressure. In summary, intravenous catheters with sizes of 14-20 G are suitable for CT angiography using an injection protocol with a high flow rate and a high-iodine-concentration contrast medium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Intravascular Iodinated Contrast Media on Natural Course of End-Stage Renal Disease Progression in Hemodialysis Patients: A Prospective Study

We evaluated the impact of intravascular iodinated contrast medium on residual diuresis in hemodialyzed patients. Two groups of clinically stable hemodialyzed patients with residual diuresis minimally 500 ml of urine per day were studied. The patients from the first group were given iso-osmolal contrast agent iodixanol (Visipaque, GE Healthcare, United Kingdom) in concentration of iodine 320 mg/ml with osmolality 290 mOsm/kg of water during the endovascular procedure. The second control group was followed without contrast medium administered. Residual diuresis and residual renal excretory capacity expressed as 24-h calculated creatinine clearance were evaluated in the both groups after 6 months. The evaluated group included 42 patients who were given 99.3 ml of iodixanol in average (range, 60-180 ml). The control group included 45 patients. There was no statistically significant difference found between both groups in daily volume of urine (P = 0.855) and calculated clearance of creatinine (P = 0.573). We can conclude that residual diuresis is not significantly influenced by intravascular administration of iso-osmolal iodinated contrast agent (iodixanol) in range of volume from 60 to 180 ml in comparison to natural course of urinary output and residual renal function during end-stage renal disease. This result can help the nephrologist to decide which imaging method/contrast medium to use in dialyzed patients in current practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superiority of Transcutaneous Oxygen Tension Measurements in Predicting Limb Salvage After Below-the-Knee Angioplasty: A Prospective Trial in Diabetic Patients With Critical Limb Ischemia

Purpose: To assess postprocedural angiograms, the ankle-brachial index (ABI), and transcutaneous oxygen tension (TcPO{sub 2}) to predict outcome after infrageniculate angioplasty (PTA) in diabetic patients with critical limb ischemia (CLI) scheduled for amputation. Materials and Methods: PTA was performed in 28 diabetic patients with CLI confined to infrapopliteal vessels. We recorded patency of crural vessels, including the vascular supply of the foot as well as the ABI and TcPO{sub 2} of the foot. Results: Technical success rate was 92.9% (n = 26), and limb-salvage rate at 12 months was 60.7% (n = 17). The number of patent straight vessels above and below the level of the malleoli increased significantly in patients avoiding amputation. Amputation was unnecessary in 88.2% (n = 15) patients when patency of at least one tibial artery was achieved. In 72.7% (n = 8) of patients, patency of the peroneal artery alone was not sufficient for limb salvage. ABI was of no predictive value for limb salvage. TcPO{sub 2} values increased significantly only in patients not requiring amputation (P = 0.015). In patients with only one tibial artery supplying the foot or only a patent peroneal artery in postprocedural angiograms, TcPO{sub 2} was capable of reliably predicting the outcome. Conclusion: Below-the-knee PTA as an isolated part of therapy was effective to prevent major amputation in more than a half of diabetic patients with CLI. TcPO{sub 2} was a valid predictor for limb salvage, even when angiographic outcome criteria failed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nature and strength of weak intermolecular interactions with metal atoms in crystals of square-planar nickel(II) complexes

The results of geometric analysis of 588 crystal structures of square-planar nickel complexes containing short intermolecular Ni…X contacts (X is a non-metal atom) are reported. The frequency of occurrence of Ni…X interactions of a particular type was evaluated depending on the nature of the X atom and geometric characteristics. The promolecular functions RDG and sign(λ{sub 2})•ρ(r) were used to analyze the character of Ni…X interactions in attractive/repulsive terms. The relative strength of these interactions was determined as the function of the nature of the X atom and the direction of charge transfer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Similarity Criteria for the Study of Removal of Spherical Non-metallic Inclusions in Physical Models of Continuous Casting Tundishes: A More Fundamental Approach

Physical modeling is widely used for studying steelmaking processes. The accuracy of this technique depends on the use of appropriate similarity criteria during experimental design. The present work deduced rigorously the similarity criteria for the study of spherical non-metallic inclusions in isothermal physical models of tundishes. Initially, macroscopic quantities were used to simplify the multiphase problem. Then, the similarity criteria were obtained from the dimensionless form of the exact equation of motion for an inclusion in Stokes regime. The validity range of these criteria was discussed and they were compared with common literature practice. Some practical considerations were also presented. This work clarifies various implicit assumptions usually adopted in literature. Additionally, a restrictive criterion to choose the density of the inclusion simulating particles was obtained, which can be satisfied, for example, by hollow glass particles in water models. This criterion is necessary to adequately describe the inclusion motion in regions where fluid elements suffer strong acceleration (e.g., inside nozzles, near flow controllers or in the entering fluid jet). Moreover, it was established an upper limit for the concentration of particles injected in the inlet nozzle of physical models, which do not simulate the phenomenon of inclusion aggregation.

36 MATERIALS SCIENCE↗

Characterization of Nonmetallic Inclusions in 18CrNiMo7-6

The detrimental effect of nonmetallic inclusions (NMIs) in steels on, e.g., fatigue lifetime is well known. In order to increase the durability and safety of materials and components, inclusion control and a deep understanding of inclusion formation are essential. The present study examines the formation of inclusions as well as their content, type, morphology, and size distribution for different batches of the steel alloy 18CrNiMo7-6 (AISI 4317), which was processed with various refractory crucible materials. To this end, extensive metallographic investigations were carried out including fracture surface analyses, metallographic sections, and the chemical extraction of inclusions. Scanning electron microscopy supported by energy-dispersive X-ray spectroscopy was used alongside electron backscatter diffraction for the qualitative and quantitative analysis of the NMIs. Oxide contents were found to have a significant effect on sulfide precipitation behavior, and had a strong impact on the resulting sizes and numbers of inclusions. The formation and growth of sulfides and oxide-sulfides featuring different morphologies is discussed on the basis of these experimental results.

36 MATERIALS SCIENCE↗

A Review of Experimental Animal Radon Health Effects [Book Chapter]

Abundant epidemiological data from underground miners confirm that radon decay products (progeny) are carcinogenic, although the evidence is less conclusive on the quantitative risks of these exposures, especially for indoor air. The imprecision results principally from differences between exposures in mining and domestic environments and from uncertainties about the interaction between smoking and exposure to radon progeny. Experimental animal studies of radon-induced lung cancer are particularly valuable for understanding the carcinogenicity of human radon exposures in the home and in the workplace. Animals can be exposed to a variety of agents under carefully controlled conditions and then sacrificed for the study of developing lesions or held for their life span for tumor development. The doses to critical cells in the respiratory tract can be determined, and these in turn can be related to doses to critical cells in the respiratory tract of humans exposed to similar aerosols. The study of radon-induced mutations and changes in expression of oncogenes and tumor-suppressor genes as well as growth factors and growth factor receptors during tumor progression in animals also provides valuable evidence on the underlying mechanisms of radon carcinogenesis. This evidence, particularly that of the efficiency for oncogenic transformation at low dose rates, is crucial to the determination of the risk of lung cancer from exposure to indoor levels of radon. This review of animal health effects data emphasizes the carcinogenicity of radon exposures in rats; mechanistic data on radon-induced lung tumors in rats are currently sparse and are not reviewed here.

560162* -- Radionuclide Effects, Kinetics, & Toxic↗

Mechanical Properties of Diamond and Diamond-Like Films

A discussion of the factors influencing hardness and elastic modulus measurements of thin films and hard materials is given with emphasis on DLC and diamond. Hardness values ranging from 5 to 15 GPa and elastic (Young's) modulus of 40 to 130 GPa were found for DLC films deposited by a variety of techniques. Both hardness and modulus values for CVD diamond films were similar to those measured on the (100) plane of a natural Type 2a diamond.

36 MATERIALS SCIENCE↗

Growth Mechanisms of CVD Diamond Films Determined by a Novel TEM Technique

A novel transmission electron microscopy (TEM) technique is introduced for studying thick as-grown CVD diamond films. For a <001> texture consisting of 2-3 μm-diam grains with (001) and {111} facets, we have found that the core volume bounded by the (001) top facet and orthogonal {110} (i.e., the volume shadowed by the (001) top) is free from microtwins and stacking faults, but may contain a few dislocations. The remaining volume around the core, bounded by {111} facets, is filled with microtwins. The formation of microtwins in CVD diamond is associated with growth on {111}. For a <001> texture with only (001) and near {110} facets, the film is free from microtwins but contains more dislocations. A (001) twin-free column model is described to summarize all these observations.

36 MATERIALS SCIENCE↗

Direct Monte Carlo Simulations of Chemical Equilibrium Composition of Molecular Fluid Mixtures Under Shock Conditions

A new Monte Carlo simulation method is implemented which holds the number and kind of atoms constant rather than the number and kind of molecules for a molecular fluid mixture. Chemical reactions are allowed as a correlated move of atoms such as an interchange of atoms between molecules. Equilibrium chemical composition is determined as an average over the simulation along with equation of state quantities. Results are presented for N 2 + O 2 → 2NO at 30GPa and 3000K. The equilibrium composition is shown to be sensitive to the potentials between unlike species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A critical compilation of experimental data on spectral lines and energy levels of hydrogen, deuterium, and tritium

For more than 50 years, Charlotte Moore's compilation of atomic energy levels and its subsequent revisions have been the standard source of reference data for the spectra of hydrogen and its isotopes. In those publications, theoretical data based on quantum-electrodynamic calculations have been given. This reflects the fact that the theory of the hydrogen spectrum has been perfected to an extent far exceeding the capabilities of the best measurements. However, rapid advances in the techniques of laser spectroscopy and optical frequency metrology have recently put experiments on a par with theory in terms of precision. This calls for construction of new comprehensive data sets for H, D, and T that summarize the latest experimental work and can be directly compared with the modern theoretical reference data. The present work compiles several tens of recent measurements of the hydrogen, deuterium, and tritium fine and hyperfine structure intervals and presents sets of energy levels and Ritz wavelengths derived from those measurements. Data exist for the fine structure of energy levels of hydrogen and deuterium up to principal quantum number n = 12. For higher lying levels, there are many observed lines with unresolved fine structure. From those observations, level centers (centers of the fine structure) are derived by a least-squares optimization, and Ritz wavelengths of series with upper levels up to n = 40 are obtained. For tritium, the n = 2 and 3 energy level intervals are derived from experimental observations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗