Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEAR INFRARED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters

Near-infrared spectroscopy (NIRS) can be used to noninvasively measure changes in the concentrations of oxy- and deoxyhemoglobin in tissue. We have previously shown that while global changes can be reliably measured, focal changes can produce erroneous estimates of concentration changes (NeuroImage 13 (2001), 76). Here, we describe four separate sources for systematic error in the calculation of focal hemoglobin changes from NIRS data and use experimental methods and Monte Carlo simulations to examine the importance and mitigation methods of each. The sources of error are: (1). the absolute magnitudes and relative differences in pathlength factors as a function of wavelength, (2). the location and spatial extent of the absorption change with respect to the optical probe, (3). possible differences in the spatial distribution of hemoglobin species, and (4). the potential for simultaneous monitoring of multiple regions of activation. We found wavelength selection and optode placement to be important variables in minimizing such errors, and our findings indicate that appropriate experimental procedures could reduce each of these errors to a small fraction (<10%) of the observed concentration changes.

Non-NASA Center↗

Visible and near-infrared channel calibration of the GOES-6 VISSR using high-altitude aircraft measurements

Present and future visible and near-infrared wavelength sensors mounted on operational satellites do not have on-board absolute calibration devices. One means of establishing an in-orbit calibration for a satellite sensor is to make simultaneous measurements of a bright, relatively uniform scene along the satellite view vector from a calibrated instrument on board a high altitude aircraft. Aircraft data were recorded over White Sands, New Mexico, and the coincident aircraft and orbiting satellite data is compared for the visible and near-infrared wavelength channel of the GOES-6 Visible Infrared Spin-Scan Radiometer.

Smith, Gilbert R.↗

The Spectral Characteristics of Lunar Agglutinates: Visible-Near-Infrared Spectroscopy of Apollo Soil Separates

The lunar surface evolves over time due to space weathering, and the visible–near-infrared spectra of more mature (i.e., heavily weathered) soils are lower in reflectance and steeper in spectral slope (i.e., darker and redder) than their immature counterparts. These spectral changes have traditionally been attributed to the space-weathered rims of soil grains (and particularly nanophase iron therein). However, understudied thus far is the spectral role of agglutinates—the agglomerates of mineral and lithic fragments, nanophase iron, and glass that are formed by micrometeoroid impacts and are ubiquitous in mature lunar soils. We separated agglutinates and non-agglutinates from six lunar soils of varying maturity and composition, primarily from the 125–250 μm size fraction, and measured their visible–near-infrared reflectance spectra. For each soil, the agglutinate spectra are darker, redder, and have weaker absorption bands than the corresponding non-agglutinate and unsorted soil spectra. Moreover, greater soil maturity corresponds to darker agglutinate spectra with weaker absorption bands. These findings suggest that agglutinates (rather than solely the space-weathered rims) play an important role in both the darkening and reddening of mature soils—at least for the size fractions examined here. Comparisons with analog soils suggest that high nanophase iron abundance in agglutinates is likely responsible for their low reflectance and spectrally red slope. Additional studies of agglutinates are needed both to more comprehensively characterize their spectral properties (across size fractions and in mixing with non-agglutinates) and to assess the relative roles of agglutinates and rims in weathering-associated spectral changes. Plain Language Summary - In scientific study of the Moon, one key focus is surface processes: how do physical and chemical properties of the Moon’s surface change over time due to weathering (e.g., bombardment by micrometeoroids and by particles from the Sun)? Such investigations provide valuable insights into the Moon’s history (such as the ages of impact craters) that are often deduced from measurements of reflected light; as a soil is weathered it reflects light differently, which manifests visually as a progressive darkening of the soil. This phenomenon had primarily been attributed to weathering-associated development of rims on individual soil grains, but in this work we explored an alternative cause: soil particles known as agglutinates (misshapen, vesicular agglomerates of mineral fragments, iron, and glass that form due to weathering processes). We isolated agglutinates of six soil samples from the Moon and measured how they reflect light. We find that they reflect light in patterns reminiscent of how the Moon’s surface does when weathered. These findings suggest that agglutinates play a more important role than previously thought in determining the light-reflecting properties of the Moon’s surface, thus warranting greater and more nuanced consideration in future studies of how the Moon’s surface changes over time.

spectroscopy↗

Near-infrared spectroscopy for monitoring of tissue oxygenation of exercising skeletal muscle in a chronic compartment syndrome model

Variations in the levels of muscle hemoglobin and of myoglobin oxygen saturation can be detected non-invasively with near-infrared spectroscopy. This technique could be applied to the diagnosis of chronic compartment syndrome, in which invasive testing has shown increased intramuscular pressure associated with ischemia and pain during exercise. We simulated chronic compartment syndrome in ten healthy subjects (seven men and three women) by applying external compression, through a wide inflatable cuff, to increase the intramuscular pressure in the anterior compartment of the leg. The tissue oxygenation of the tibialis anterior muscle was measured with near-infrared spectroscopy during gradual inflation of the cuff to a pressure of forty millimeters of mercury (5.33 kilopascals) during fourteen minutes of cyclic isokinetic dorsiflexion and plantar flexion of the ankle. The subjects exercised with and without external compression. The data on tissue oxygenation for each subject then were normalized to a scale of 100 per cent (the baseline value, or the value at rest) to 0 per cent (the physiological minimum, or the level of oxygenation achieved by exercise to exhaustion during arterial occlusion of the lower extremity). With external compression, tissue oxygenation declined at a rate of 1.4 +/- 0.3 per cent per minute (mean and standard error) during exercise. After an initial decrease at the onset, tissue oxygenation did not decline during exercise without compression. The recovery of tissue oxygenation after exercise was twice as slow with compression (2.5 +/- 0.6 minutes) than it was without the use of compression (1.3 +/- 0.2 minutes).

NASA Discipline Musculoskeletal↗

Near-infrared continuum and 3.3 micrometer(s) polycyclic aromatic hydrocarbon imaging of the starburst ring in the type 1 Seyfert galaxy NGC 7469

High resolution near-infrared images of the type 1 Seyfert galaxy NGC 7469 have been obtained to probe its dusty nuclear environment. Direct J, H, and K images are relatively featureless, but residual images created by subtracting a smooth model based on best-fitting elliptical isophotes reveal a tight inner spiral whose high surface-brightness portions correspond to a previously detected 3 sec (1 kpc) diameter ring of radio continuum emission. The inner infrared spiral arms extended approximately equal to 4 sec NW and SE from the nucleus, and the NW arm joins up with large-scale spiral structure visible in the R band. The residual images also show a bar-like structure aligned with the brightest infrared/radio hotspots at PA approximately equal to 50 deg. Three infrared hotspots are detected which align remarkably well with 6 cm radio continuum sources. The near-infrared ring and the hotspots are visible in the residual images, and in a high-resolution direct K-band image restored to an effective resolution of 0.65 sec (FWHM) using the Richardson-Lucy algorithm. The infrared hotspots have luminosities of nuL(sub nu) (2.2 micrometer(s)) approximately equal to 10(exp 8) solar luminosity (M(sub k) approximately equal to -16 mag), suggesting they are either giant H II regions or individual supernovae. The two brightest regions may be associated with enhanced star formation triggered by orbit crowding of gas where spiral arms emerge from an inner bar. Narrowband (delta lambda/lambda approximately 1.5%) imaging in the 3.28 micrometer(s) dust emission feature and surrounding continuum confirms the 3 sec diameter 3.28 micrometer(s) emission region detected previously using multiaperture photometry. The extended polycyclic aromatic hydrocarbon (PAH) emission is slightly elongated and aligned with published 1O III1 line emission and 12.5 micrometer(s) continuum emission, apparently tracing the starburst. The presence of approximately equal to 25% of the total 3.28 micrometer(s) PAH emission within R less than 1 sec demonstrates that a starburst within the central few hundred parsecs must supply a significant fraction of the infrared continuum from the nucleus, and there is apparently sufficient shielding material between the starburst and the active galactic nucleus (AGN) to preserve the PAHs along our line of sight to the nucleus.

Mazzarella, J. M.↗

Imaging systems for the delineation of spectral properties of geologic materials in the visible and near-infrared

The current status of imaging systems for the identification of the spectral properties of geologic minerals in the visible and near infrared ranges is reviewed. The technical characteristics of the most important instruments are given, including the MSS and TM, the Airborne Imaging Spectrometer, (AIS) the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), and the Shuttle Imaging Spectrometer Experiment (SISEX). It is pointed out that none of the current systems have sufficient spectral resolution to identify mineralogy on the basis of absorption characteristics in the visible, near-infrared or shortwave-infrared bands. The development of new systems with higher spectral resolution is discussed.

Marsh, S. E.↗

Gemini Near Infrared Field Spectrograph Observations of the Seyfert 2 Galaxy MRK 573: In Situ Acceleration of Ionized and Molecular Gas Off Fueling Flows

We present near-infrared and optical emission-line and stellar kinematics of the Seyfert 2 galaxy Mrk 573 using the Near-Infrared Field Spectrograph (NIFS) at Gemini North and Dual Imaging Spectrograph at Apache Point Observatory, respectively. By obtaining full kinematic maps of the infrared ionized and molecular gas and stellar kinematics in approximately 700 x 2100 pc(exp 2) circumnuclear region of Mrk 573, we find that kinematics within the Narrow-Line Region are largely due to a combination of both rotation and in situ acceleration of material originating in the host disk. Combining these observations with large-scale, optical long-slit spectroscopy that traces ionized gas emission out to several kpcs, we find that rotation kinematics dominate the majority of the gas. We find that outflowing gas extends to distances less than 1 kpc, suggesting that outflows in Seyfert galaxies may not be powerful enough to evacuate their entire bulges.

galaxies: active – galaxies: individual (Mrk 573↗

Characterization of the Ryugu Surface By Means Of the Variability of the Near-Infrared Spectral Slope in NIRS3 Data

The Near-Earth Asteroid 162173 Ryugu (1999 JU3) was investigated by the JAXA Hayabusa2 mission from June 2018 to November 2019. The data acquired by NIRS3 spectrometer revealed a dark surface with a positive near-infrared spectral slope. In this work we investigated the spectral slope variations across the Ryugu surface, providing information about physical/chemical properties of the surface. We analysed the calibrated, thermally and photometrically corrected NIRS3 data and we estimated the mean value of spectral slope between 1.9 μm and 2.5 μm, corresponding to 0.163. Starting from the mean value of slope and moving in step of 1 standard deviation (0.022), we defined 9 “families of slope”, the Low-Red-Slope families (LR1, LR2 and LR3) and the High-Red-Sloped families (HR1, HR2, HR3, HR4, HR5, HR6). The mean values of some spectral parameters were estimated for each family, such as the reflectance factor at 1.9 μm, the spectral slope, the depth of bands at 2.7 μm and at 2.8 μm. A progressive spectral reddening, darkening and weakening/narrowing of OH bands is observed moving from the LR families to the HR families. We concluded that the spectral variability observed among families is the resulting contribution of the thermal metamorphism experienced by Ryugu after the catastrophic disruption of its parent body and space weathering processes that occurred on airless bodies as Ryugu, such as impact cratering and solar wind irradiation. As a consequence, the HR1, LR1, LR2 and LR3 families, corresponding to equatorial ridge and crater rims, are the less altered regions on Ryugu surface, which experienced the minor alteration and OH devolatilization; the HR2, HR3, HR4, HR5 families, coincident with floors and walls of impact craters, are the most altered areas, result of the three processes occurred on Ryugu. The strong reddening of the HR6 family (coincident with Ejima Saxum) is likely due to the fine-sized material covering the large boulder.

Ryugu↗

Detection of a near-infrared complex associated with S140 IRS

A near-infrared (0.9-micron) counterpart to the bright compact infrared source in Sharpless 140 has been detected. Observations with a CCD array show structure within a few arcseconds of the 2-20-micron source. The possible nature of the source is discussed, and an upper limit is set on the ionizing flux.

Dinerstein, H. L.↗

Mars: Near-infrared comparative spectroscopy during the 1986 opposition

Near-infrared spectral observations of Mars during the 1986 opposition were performed at the Mauna Kea Observatory utilizing the University of Hawaii's 88 inch telescope. Spectra were obtained of several Martian locations using a continuously variable filter (CVF) spectrometer with a resolution of 1.25 percent. Spot-to-spot ratios were produced between spectra taken in different geological regions.

Bell, James F., III↗

Functional Near Infrared Spectroscopy: Watching the Brain in Flight

Functional Near Infrared Spectroscopy (fNIRS) is an emerging neurological sensing technique applicable to optimizing human performance in transportation operations, such as commercial aviation. Cognitive state can be determined via pattern classification of functional activations measured with fNIRS. Operational application calls for further development of algorithms and filters for dynamic artifact removal. The concept of using the frequency domain phase shift signal to tune a Kalman filter is introduced to improve the quality of fNIRS signals in realtime. Hemoglobin concentration and phase shift traces were simulated for four different types of motion artifact to demonstrate the filter. Unwanted signal was reduced by at least 43%, and the contrast of the filtered oxygenated hemoglobin signal was increased by more than 100% overall. This filtering method is a good candidate for qualifying fNIRS signals in real time without auxiliary sensors

Harrivel, Angela↗

Functional Near Infrared Spectroscopy: Watching the Brain in Flight

Functional Near Infrared Spectroscopy (fNIRS) is an emerging neurological sensing technique applicable to optimizing human performance in transportation operations, such as commercial aviation. Cognitive state can be determined via pattern classification of functional activations measured with fNIRS. Operational application calls for further development of algorithms and filters for dynamic artifact removal. The concept of using the frequency domain phase shift signal to tune a Kalman filter is introduced to improve the quality of fNIRS signals in real-time. Hemoglobin concentration and phase shift traces were simulated for four different types of motion artifact to demonstrate the filter. Unwanted signal was reduced by at least 43%, and the contrast of the filtered oxygenated hemoglobin signal was increased by more than 100% overall. This filtering method is a good candidate for qualifying fNIRS signals in real time without auxiliary sensors.

Harrivel, Angela↗

Bench-Top Antigen Detection Technique that Utilizes Nanofiltration and Fluorescent Dyes which Emit and Absorb Light in the Near Infrared

This article discusses the development of a bench-top technique to detect antigens in fluids. The technique involves the use of near infrared NIR fluorescent dyes conjugated to antibodies, centrifugation, nanofilters, and spectrometry. The system used to detect the antigens utilizes a spectrometer, fiber optic cables, NIR laser, and laptop computer thus making it portable and ideally suited for desk top analysis. Using IgM as an antigen and the secondary antibody, anti-IgM conjugated to the near infrared dye, IRDye (trademark) 800, for detection, we show that nanofiltration can efficiently and specifically separate antibody-antigen complexes in solution and that the complexes can be detected by a spectrometer and software using NIR laser excitation at 778 nm and NIR dye offset emission at 804 nm. The peak power detected at 778 nm for the excitation emission and at 804 nm for the offset emission is 879 pW (-60.06 dBm) and 35.7 pW (-74.5 dBm), respectively.

Varaljay-Spence, Vanessa A.↗

Hi-5: A Potential High-Contrast Thermal Near-Infrared Imager for the VLTI

Hi-5 is a high-contrast (or high dynamic range) infrared imager project for the VLTI. Its main goal is to characterize young extra-solar planetary systems and exozodiacal dust around southern main-sequence stars. In this paper, we present an update of the project and key technology pathways to improve the contrast achieved by the VLTI. In particular, we discuss the possibility to use integrated optics, proven in the near-infrared, in the thermal near-infrared (L and M bands, 3-5 μm) and advanced fringe tracking strategies. We also address the strong exoplanet science case (young exoplanets, planet formation, and exozodiacal disks) offered by this wavelength regime as well as other possible science cases such as stellar physics (fundamental parameters and multiplicity) and extragalactic astrophysics (active galactic nuclei and fundamental constants). Synergies and scientific preparation for other potential future instruments such as the Planet Formation Imager are also briefly discussed.

exozodiacal dust↗

High resolution near-infrared imaging of the trapezium: A stellar census

We present high spatial resolution (0.35 and 0.65 arcsec full width at half maximum (FWHM)) near-infrared images of the central 0.2x0.2 pc of the Trapezium Cluster in the Orion Nebula, centered on the Trapezium OB stars. These images provide the most complete census of stars in this region, and we give accurate positions and near-infrared (2.1 microns) magnitudes for 123 stars. After accounting for line-of-sight projection, we estimate a stellar density for the cluster of approximately 4.7 X 10(exp 4) stars per cubic parsec in the approximately 0.1 pc diameter core. We identify stellar counterparts to virtually all the known dense knots of ionized gas seen at optical and radio wavelengths, strongly supporting the hypothesis that many are either intrinsic stellar radio emitters or circumstellar disks around stars, and not simply dense clumps of gas and dust. We derive approximate masses for the stars associated with the compact knots, finding that the majority are relatively low mass.

Mccaughrean, Mark J.↗

Scanless laser waveform measurement in the near-infrared

Field-resolved measurements of few-cycle laser waveforms allow access to ultrafast electron dynamics in light–matter interactions and are key to future lightwave electronics. Recently, sub-cycle gating based on nonlinear excitation in active pixel sensors has allowed the first single-shot measurements of mid-infrared optical fields. Extending the techniques to shorter wavelengths, however, is not feasible using silicon-based detectors with bandgaps in the near-infrared. Here, we demonstrate an all-optical sampling technique for near-infrared laser fields, wherein an intense fundamental field generates a sub-cycle gate through nonlinear excitation of a wide-bandgap crystal, in this case, ZnO, which can sample the electric field of a weak perturbing pulse. By using a crossed-beam geometry, the temporal evolution of the perturbing field is mapped onto a transverse spatial axis of the nonlinear medium, and the waveform is captured in a single measurement of the spatially resolved fluorescence emission from the crystal. The technique is demonstrated through field-resolved measurements of the field reshaping during nonlinear propagation in the ZnO detection crystal.

Truong, Tran-Chau (ORCID:0000000348940635)↗

Moon - Near-infrared spectral reflectance, a first good look

Spectral reflectance contains direct information on the mineralogy of the surface soils and rocks. A problem concerning the employment of remote spectral-reflectance sensing techniques for mineralogical studies is related to the lack of photometrically precise spectra of planetary surfaces in the region from 1.0 to 2.5 micrometers, where additional important mineral absorptions occur. Recently, a new instrument was developed, and an observational program is underway to provide the required near-infrared spectra. The first, comprehensive near-infrared spectroscopic results for the moon are presented. It is shown that it is equally possible to derive quantitative mineralogical information about the lunar surface by using remotely sensed reflectance spectra as it is by using laboratory reflectance measurements of lunar samples.

Mccord, T. B.↗