Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Impact of geostationary satellite water vapor channel data on weather analysis and forecasting

Preliminary results from NWP impact studies are indicating that upper-tropospheric wind information provided by tracking motions in sequences of geostationary satellite water vapor imagery can positively influence forecasts on regional scales, and possibly on global scales as well. The data are complimentary to cloud-tracked winds by providing data in cloud-free regions, as well as comparable in quality. First results from GOES-8 winds are encouraging, and further efforts and model impacts will be directed towards optimizing these data in numerical weather prediction (NWP). Assuming successful launches of GOES-J and GMS-5 satellites in 1995, high quality and resolution water vapor imagers will be available to provide nearly complete global upper-tropospheric wind coverage.

Velden, Christopher S.↗

Motion Dynamics of Motile Microbes in Pore-Networks and its Implications for Reactive Transport Processes

This report outlines new methods to improve simulations of microbial transport and microbially mediated reactions in porous media. A range of experimental, modeling, and machine learning tools are introduced to make these simulations faster, more reliable, and useful for real-world applications. At the microscopic level, the study investigates how different types of bacteria move through confined spaces. A new artificial intelligence tool called DeepTrackStat, is introduced to track motions dynamics as observed in videos of particles migrating through pore networks. This tool is especially helpful for studying fast-moving microbes and requires less computing power than traditional tracking methods. At larger scales, the research looks at how microbes and chemicals interact in zones where surface water and groundwater meet. To connect the small- and large-scale findings, the study presents a neural network model called STAMNet. This tool helps scale up detailed small-scale microbial motion behaviors to predict large-scale environmental changes more efficiently. By combining lab experiments, computer models, and artificial intelligence, the research presented supports smarter environmental decision-making, especially in bioremediation of contaminated groundwater and protection of water quality.

54 ENVIRONMENTAL SCIENCES↗

Nonlinear automatic landing control of unmanned aerial vehicles on moving platforms via a 3D laser radar

This paper presents a motion tracking and control system for automatically landing Unmanned Aerial Vehicles (UAVs) on an oscillating platform using Laser Radar (LADAR) observations. The system itself is assumed to be mounted on a ship deck. A full nonlinear mathematical model is first introduced for the UAV. The ship motion is characterized by a Fourier transform based method which includes a realistic characterization of the sea waves. LADAR observation models are introduced and an algorithm to process those observations for yielding the relative state between the vessel and the UAV is presented, from which the UAV's state relative to an inertial frame can be obtained and used for feedback purposes. A sliding mode control algorithm is derived for tracking a landing trajectory defined by a set of desired waypoints. An extended Kalman filter (EKF) is proposed to account for process and observation noises in the design of a state estimator. The effectiveness of the control algorithm is illustrated through a simulation example.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Clinical development of a failure detection-based online repositioning strategy for prostate IMRT--Experiments, simulation, and dosimetry study

Purpose: To implement and evaluate clinic-ready adaptive imaging protocols for online patient repositioning (motion tracking) during prostate IMRT using treatment beam imaging supplemented by minimal, as-needed use of on-board kV. Methods: The authors examine the two-step decision-making strategy: (1) Use cine-MV imaging and online-updated characterization of prostate motion to detect target motion that is potentially beyond a predefined threshold and (2) use paired MV-kV 3D localization to determine overthreshold displacement and, if needed, reposition the patient. Two levels of clinical implementation were evaluated: (1) Field-by-field based motion correction for present-day linacs and (2) instantaneous repositioning for new-generation linacs with capabilities of simultaneous MV-kV imaging and remote automatic couch control during treatment delivery. Experiments were performed on a Varian Trilogy linac in clinical mode using a 4D motion phantom programed with prostate motion trajectories taken from patient data. Dosimetric impact was examined using a 2D ion chamber array. Simulations were done for 536 trajectories from 17 patients. Results: Despite the loss of marker detection efficiency caused by the MLC leaves sometimes obscuring the field at the marker's projected position on the MV imager, the field-by-field correction halved (from 23% to 10%) the mean percentage of time that target displacement exceeded a 3 mm threshold, as compared to no intervention. This was achieved at minimal cost in additional imaging (average of one MV-kV pair per two to three treatment fractions) and with a very small number of repositionings (once every four to five fractions). Also with low kV usage ({approx}2/fraction), the instantaneous repositioning approach reduced overthreshold time by more than 75% (23% to 5%) even with severe MLC blockage as often encountered in current IMRT and could reduce the overthreshold time tenfold (to <2%) if the MLC blockage problem were relieved. The information acquired for repositioning using combined MV-kV images was found to have submillimeter accuracy. Conclusions: This work demonstrated with a current clinical setup that substantial reduction of adverse targeting effects of intrafraction prostate motion can be realized. The proposed adaptive imaging strategy incurs minimal imaging dose to the patient as compared to other stereoscopic imaging techniques.

60 APPLIED LIFE SCIENCES↗

SU-E-T-648: Quality Assurance Using the RADPOS System for 4D Radiotherapy with CyberKnife

Purpose: The CyberKnife robotic radiosurgery system uses Synchrony respiratory motion compensation, which requires independent performance verification. In this work, the RADPOS 4D dosimetry system’s motion measurements are compared with internal fiducial position measurements. In addition, RADPOS measurements are compared with Synchrony’s predictive correlation model, which is based on internal fiducial and external LED marker position measurements. Methods: A treatment plan was created for a lung insert containing fiducials, RADPOS detector, and Solid Water tumor phantom. Two Quasar Respiratory Motion Phantoms (Q1 and Q2) and two RADPOS detectors (R1 and R2) were used: Q1 simulated lung motion with a lung insert moving in the superior/inferior direction, while Q2 simulated chest motion with a chest platform moving in the anterior/posterior direction. Before treatment, R1 was secured inside of the tumor phantom within Q1, while LED markers and R2 were positioned on the chest platform of Q2. Two treatment delivery cases were studied: isocentric plan (I) and non-isocentric patient plan (P). Four motion cases were studied: no motion (0), sinusoidal and in-phase (1), sinusoidal and out-of-phase (2), patient waveform and out-of-phase (3). A coordinate alignment algorithm was implemented, allowing RADPOS and model position data to be compared within the fiducial coordinate system. Results: The standard deviation of the differences between RADPOS and fiducial position measurements was below 0.6 mm for all experimental cases. The standard deviation of the differences between RADPOS and model position data was 1.0, 1.5, and 1.6 mm along the primary direction of motion for case I1, I2, and P3, respectively. Conclusion: Our work demonstrates that RADPOS is a useful tool for independent quality assurance of CyberKnife treatment with Synchrony respiratory compensation. RADPOS and fiducial position measurement closely match, and RADPOS confirms the effectiveness of CyberKnife’s Synchrony motion tracking. This work was supported by OCAIRO (Ontario Consortium for Adaptive Interventions in Radiation Oncology) grant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In-situ L-TEM observations of dynamics of nanometric skyrmions and antiskyrmions

Nanometer-scale magnetic skyrmions and antiskyrmions exhibit unique dynamical behaviors in response to external stimuli, which are critical for their applications in low-power-consumption spintronic devices. This review discusses recent advancements in in-situ Lorentz transmission electron microscopy (L-TEM) observations of skyrmion and antiskyrmion dynamics, and demonstrates the manipulation and evolution of these textures in various magnetic materials under electric, magnetic, and thermal stimuli. Specifically, the motion tracking of single skyrmions and their clusters, and the deformation and transformation of skyrmions has been demonstrated in chiral helimagnets FeGe, Co 9 Zn 9 Mn 2 , and Co 10 Zn 10 with precise application of electric currents. Skyrmions can undergo dynamic transitions in current-driven skyrmion motions, from pinned states to linear flows, and even exhibit deformation into elliptical shapes, underscoring their topological robustness and dynamic flexibility. In addition, the manipulation of single antiskyrmions and antiskyrmion-lattice phases in (Fe 0.63 Ni 0.3 Pd 0.07 ) 3 P with S 4 symmetry is discussed, highlighting their high mobility and unique sliding capabilities along stripe domains at room temperature, facilitated by nanosecond pulsed electric currents. Finally, the temperature gradient-driven motion and topological transformation of elliptical skyrmions and antiskyrmions in this same material are investigated. In conclusion, the comprehensive insights gained from the L-TEM imaging technique are pivotal in advancing the design and functionality of next-generation skyrmion/antiskyrmion-based spintronic devices.

(Anti)skyrmion↗

Intrafraction Prostate Translations and Rotations During Hypofractionated Robotic Radiation Surgery: Dosimetric Impact of Correction Strategies and Margins

Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. Methods and Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images). The simulated extent of robot corrections was also varied: no corrections, translational corrections only, and translational corrections combined with rotational corrections up to 5°, 10°, and perfect rotational correction. The correction strategies were evaluated for treatment plans with a 0-mm or 3-mm margin around the clinical target volume (CTV). We recorded CTV coverage (V{sub 100%}) and dose-volume parameters of the peripheral zone (boost), rectum, bladder, and urethra. Results: Planned dose parameters were increasingly preserved with larger extents of robot corrections. A time interval between corrections of 60 to 180 seconds provided optimal preservation of CTV coverage. To achieve 98% CTV coverage in 98% of the treatments, translational and rotational corrections up to 10° were required for the 0-mm margin plans, whereas translational and rotational corrections up to 5° were required for the 3-mm margin plans. Rectum and bladder were spared considerably better in the 0-mm margin plans. Adaptive timing did not improve delivered dose. Conclusions: Intrafraction prostate motion substantially affected the delivered dose but was compensated for effectively by robot corrections using a time interval of 60 to 180 seconds. A 0-mm margin required larger extents of additional rotational corrections than a 3-mm margin but resulted in lower doses to rectum and bladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The total mass of the Large Magellanic Cloud from its perturbation on the Orphan stream

In a companion paper by Koposov et al., RR Lyrae from Gaia Data Release 2 are used to demonstrate that stars in the Orphan stream have velocity vectors significantly misaligned with the stream track, suggesting that it has received a large gravitational perturbation from a satellite of the Milky Way. We argue that such a mismatch cannot arise due to any realistic static Milky Way potential and then explore the perturbative effects of the Large Magellanic Cloud (LMC). We find that the LMC can produce precisely, the observed motion-track mismatch and we therefore use the Orphan stream to measure the mass of the Cloud. We simultaneously fit the Milky Way and LMC potentials and infer that a total LMC mass of |$1.38^{+0.27}_{-0.24} \times 10^{11}\, \rm {M_\odot}$| is required to bend the Orphan stream, showing for the first time that the LMC has a large and measurable effect on structures orbiting the Milky Way. This has far-reaching consequences for any technique which assumes that tracers are orbiting a static Milky Way. Furthermore, we measure the Milky Way mass within 50 kpc to be |$3.80^{+0.14}_{-0.11}\times 10^{11} \, \mathrm{M}_\odot$|. Finally, we use these results to predict that, due to the reflex motion of the Milky Way in response to the LMC, the outskirts of the Milky Way’s stellar halo should exhibit a bulk, upwards motion.

79 ASTRONOMY AND ASTROPHYSICS↗

Integration of Real-Time Internal Electromagnetic Position Monitoring Coupled With Dynamic Multileaf Collimator Tracking: An Intensity-Modulated Radiation Therapy Feasibility Study

Purpose: Continuous tumor position measurement coupled with a tumor tracking system would result in a highly accurate radiation therapy system. Previous internal position monitoring systems have been limited by fluoroscopic radiation dose and low delivery efficiency. We aimed to incorporate a continuous, electromagnetic, three-dimensional position tracking system (Calypso 4D Localization System) with a dynamic multileaf collimator (DMLC)-based dose delivery system. Methods and Materials: A research version of the Calypso System provided real-time position of three Beacon transponders. These real-time three-dimensional positions were sent to research MLC controller with a motion-tracking algorithm that changed the planned leaf sequence. Electromagnetic transponders were embedded in a solid water film phantom that moved with patient lung trajectories while being irradiated with two different plans: a step-and-shoot intensity-modulated radiation therapy (S-IMRT) field and a dynamic IMRT (D-IMRT) field. Dosimetric results were recorded under three conditions: no intervention, DMLC tracking, and a spatial gating system. Results: Dosimetric accuracy was comparable for gating and DMLC tracking. Failure rates for gating/DMLC tracking are as follows: {+-}3 cGy 10.9/ 7.5% for S-IMRT, 3.3/7.2% for D-IMRT; gamma (3mm/3%) 0.2/1.2% for S-IMRT, 0.2/0.2% for D-IMRT. DMLC tracking proved to be as efficient as standard delivery, with a two- to fivefold efficiency increase over gating. Conclusions: Real-time target position information was successfully integrated into a DMLC effector system to modify dose delivery. Experimental results show both comparable dosimetric accuracy as well as improved efficiency compared with spatial gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tracking blobs in the turbulent edge plasma of a tokamak fusion device

Abstract The analysis of turbulence in plasmas is fundamental in fusion research. Despite extensive progress in theoretical modeling in the past 15 years, we still lack a complete and consistent understanding of turbulence in magnetic confinement devices, such as tokamaks. Experimental studies are challenging due to the diverse processes that drive the high-speed dynamics of turbulent phenomena. This work presents a novel application of motion tracking to identify and track turbulent filaments in fusion plasmas, called blobs, in a high-frequency video obtained from Gas Puff Imaging diagnostics. We compare four baseline methods (RAFT, Mask R-CNN, GMA, and Flow Walk) trained on synthetic data and then test on synthetic and real-world data obtained from plasmas in the Tokamak à Configuration Variable (TCV). The blob regime identified from an analysis of blob trajectories agrees with state-of-the-art conditional averaging methods for each of the baseline methods employed, giving confidence in the accuracy of these techniques. By making a dataset and benchmark publicly available, we aim to lower the entry barrier to tokamak plasma research, thereby greatly broadening the community of scientists and engineers who might apply their talents to this endeavor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A functional video-based anthropometric measuring system

A high-speed anthropometric three dimensional measurement system using the Selcom Selspot motion tracking instrument for visual data acquisition is discussed. A three-dimensional scanning system was created which collects video, audio, and performance data on a single standard video cassette recorder. Recording rates of 1 megabit per second for periods of up to two hours are possible with the system design. A high-speed off-the-shelf motion analysis system for collecting optical information as used. The video recording adapter (VRA) is interfaced to the Selspot data acquisition system.

Nixon, J. H.↗

Use of dMLC for implementation of dynamic respiratory-gated radiation therapy

Purpose: To simulate and evaluate the use of dynamic multileaf collimators (dMLC) in respiratory gating to compensate for baseline drift.Methods: Tumor motion tracking data from 30 lung tumors over 322 treatment fractions was analyzed with the finite state model. A dynamic respiratory gating window was established in real-time by determining the average positions during the previous two end-of-expiration breathing phases and centering the dMLC aperture on a weighted average of these positions. A simulated dMLC with physical motion constraints was used in dynamic gating treatment simulations. Fluence maps were created to provide a statistical description of radiation delivery for each fraction. Duty cycle was also calculated for each fraction.Results: The average duty cycle was 2.3% greater under dynamic gating conditions. Dynamic gating also showed higher fluences and less tumor obstruction. Additionally, dynamic gating required fewer beam toggles and each delivery period was longer on average than with static gating.Conclusions: The use of dynamic gating showed better performance than static gating and the physical constraints of a dMLC were shown to not be an impediment to dynamic gating.

61 RADIATION PROTECTION AND DOSIMETRY↗

A geopotential model from satellite tracking, altimeter, and surface gravity data: GEM-T3

An improved model of Earth's gravitational field, Goddard Earth Model T-3 (GEM-T3), has been developed from a combination of satellite tracking, satellite altimeter, and surface gravimetric data. GEM-T3 provides a significant improvement in the modeling of the gravity field at half wavelengths of 400 km and longer. This model, complete to degree and order 50, yields more accurate satellite orbits and an improved geoid representation than previous Goddard Earth Models. GEM-T3 uses altimeter data from GEOS 3 (1975-1976), Seasat (1978) and Geosat (1986-1987). Tracking information used in the solution includes more than 1300 arcs of data encompassing 31 different satellites. The recovery of the long-wavelength components of the solution relies mostly on highly precise satellite laser ranging (SLR) data, but also includes Tracking Network (TRANET) Doppler, optical, and satellite-to-satellite tracking acquired between the ATS 6 and GEOS 3 satellites. The main advances over GEM-T2 (beyond the inclusion of altimeter and surface gravity information which is essential for the resolution of the shorter wavelength geoid) are some improved tracking data analysis approaches and additional SLR data. Although the use of altimeter data has greatly enhanced the modeling of the ocean geoid between 65 deg N and 60 deg S latitudes in GEM-T3, the lack of accurate detailed surface gravimetry leaves poor geoid resolution over many continental regions of great tectonic interest (e.g., Himalayas, Andes). Estimates of polar motion, tracking station coordinates, and long-wavelength ocean tidal terms were also made (accounting for 6330 parameters). GEM-T3 has undergone error calibration using a technique based on subset solutions to produce reliable error estimates. The calibration is based on the condition that the expected mean square deviation of a subset gravity solution from the full set values is predicted by the solutions' error covariances. Data weights are iteratively adjusted until this condition for the error calibration is satisfied. In addition, gravity field tests were performed on strong satellite data sets withheld from the solution (thereby ensuring their independence). In these tests, the performance of the subset models on the withheld observations is compared to error projections based on their calibrated error covariances. These results demonstrate that orbit accuracy projections are reliable for new satellites which were not included in GEM-T3.

Lerch, F. J.↗

A Failure Detection Strategy for Intrafraction Prostate Motion Monitoring With On-Board Imagers for Fixed-Gantry IMRT

Purpose: To develop methods to monitor prostate intrafraction motion during fixed-gantry intensity-modulated radiotherapy using MV treatment beam imaging together with minimal kV imaging for a failure detection strategy that ensures prompt detection when target displacement exceeds a preset threshold. Methods and Materials: Real-time two-dimensional (2D) marker position in the MV image plane was obtained by analyzing cine-MV images. The marker's in-line movement, and thus its time-varying three-dimensional (3D) position, was estimated by combining the 2D projection data with a previously established correlative relationship between the directional components of prostate motion. A confirmation request for more accurate localization using MV-kV triangulation was triggered when the estimated prostate displacement based on the cine-MV data was greater than 3 mm. An interventional action alert followed on positive MV-kV confirmation. To demonstrate the feasibility and accuracy of the proposed method, simulation studies of conventional-fraction intensity-modulated radiotherapy sessions were done using 536 Calypso-measured prostate trajectories from 17 radiotherapy patients. Results: A technique for intrafraction prostate motion management has been developed. The technique, using 'freely available' cine-MV images and minimum on-board kV imaging (on average 2.5 images/fraction), successfully limited 3D prostate movement to within a range of 3 mm relative to the MV beam for 99.4% of the total treatment time. On average, only approximately one intervention/fraction was needed to achieve this level of accuracy. Conclusion: Instead of seeking to accurately and continuously localize the prostate target as existing motion tracking systems do, the present technique effectively uses cine-MV data to provide a clinically valuable way to minimize kV usage, while maintaining high targeting accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imagery Integration Team

The Human Exploration Science Office (KX) provides leadership for NASA's Imagery Integration (Integration 2) Team, an affiliation of experts in the use of engineering-class imagery intended to monitor the performance of launch vehicles and crewed spacecraft in flight. Typical engineering imagery assessments include studying and characterizing the liftoff and ascent debris environments; launch vehicle and propulsion element performance; in-flight activities; and entry, landing, and recovery operations. Integration 2 support has been provided not only for U.S. Government spaceflight (e.g., Space Shuttle, Ares I-X) but also for commercial launch providers, such as Space Exploration Technologies Corporation (SpaceX) and Orbital Sciences Corporation, servicing the International Space Station. The NASA Integration 2 Team is composed of imagery integration specialists from JSC, the Marshall Space Flight Center (MSFC), and the Kennedy Space Center (KSC), who have access to a vast pool of experience and capabilities related to program integration, deployment and management of imagery assets, imagery data management, and photogrammetric analysis. The Integration 2 team is currently providing integration services to commercial demonstration flights, Exploration Flight Test-1 (EFT-1), and the Space Launch System (SLS)-based Exploration Missions (EM)-1 and EM-2. EM-2 will be the first attempt to fly a piloted mission with the Orion spacecraft. The Integration 2 Team provides the customer (both commercial and Government) with access to a wide array of imagery options - ground-based, airborne, seaborne, or vehicle-based - that are available through the Government and commercial vendors. The team guides the customer in assembling the appropriate complement of imagery acquisition assets at the customer's facilities, minimizing costs associated with market research and the risk of purchasing inadequate assets. The NASA Integration 2 capability simplifies the process of securing one-of-a-kind imagery assets and skill sets, such as ground-based fixed and tracking cameras, crew-in the-loop imaging applications, and the integration of custom or commercial-off-the-shelf sensors onboard spacecraft. For spaceflight applications, the Integration 2 Team leverages modeling, analytical, and scientific resources along with decades of experience and lessons learned to assist the customer in optimizing engineering imagery acquisition and management schemes for any phase of flight - launch, ascent, on-orbit, descent, and landing. The Integration 2 Team guides the customer in using NASA's world-class imagery analysis teams, which specialize in overcoming inherent challenges associated with spaceflight imagery sets. Precision motion tracking, two-dimensional (2D) and three-dimensional (3D) photogrammetry, image stabilization, 3D modeling of imagery data, lighting assessment, and vehicle fiducial marking assessments are available. During a mission or test, the Integration 2 Team provides oversight of imagery operations to verify fulfillment of imagery requirements. The team oversees the collection, screening, and analysis of imagery to build a set of imagery findings. It integrates and corroborates the imagery findings with other mission data sets, generating executive summaries to support time-critical mission decisions.

Calhoun, Tracy↗

A framework for the correction of slow physiological drifts during MR-guided HIFU therapies: Proof of concept

Purpose: While respiratory motion compensation for magnetic resonance (MR)-guided high intensity focused ultrasound (HIFU) interventions has been extensively studied, the influence of slow physiological motion due to, for example, peristaltic activity, has so far been largely neglected. During lengthy interventions, the magnitude of the latter can exceed acceptable therapeutic margins. The goal of the present study is to exploit the episodic workflow of these therapies to implement a motion correction strategy for slow varying drifts of the target area and organs at risk over the entire duration of the intervention. Methods: The therapeutic workflow of a MR-guided HIFU intervention is in practice often episodic: Bursts of energy delivery are interleaved with periods of inactivity, allowing the effects of the beam on healthy tissues to recede and/or during which the plan of the intervention is reoptimized. These periods usually last for at least several minutes. It is at this time scale that organ drifts due to slow physiological motion become significant. In order to capture these drifts, the authors propose the integration of 3D MR scans in the therapy workflow during the inactivity intervals. Displacements were estimated using an optical flow algorithm applied on the 3D acquired images. A preliminary study was conducted on ten healthy volunteers. For each volunteer, 3D MR images of the abdomen were acquired at regular intervals of 10 min over a total duration of 80 min. Motion analysis was restricted to the liver and kidneys. For validating the compatibility of the proposed motion correction strategy with the workflow of a MR-guided HIFU therapy, an in vivo experiment on a porcine liver was conducted. A volumetric HIFU ablation was completed over a time span of 2 h. A 3D image was acquired before the first sonication, as well as after each sonication. Results: Following the volunteer study, drifts larger than 8 mm for the liver and 5 mm for the kidneys prove that slow physiological motion can exceed acceptable therapeutic margins. In the animal experiment, motion tracking revealed an initial shift of up to 4 mm during the first 10 min and a subsequent continuous shift of ∼2 mm/h until the end of the intervention. This leads to a continuously increasing mismatch of the initial shot planning, the thermal dose measurements, and the true underlying anatomy. The estimated displacements allowed correcting the planned sonication cell cluster positions to the true target position, as well as the thermal dose estimates during the entire intervention and to correct the nonperfused volume measurement. A spatial coherence of all three is particularly important to assure a confluent ablation volume and to prevent remaining islets of viable malignant tissue. Conclusions: This study proposes a motion correction strategy for displacements resulting from slowly varying physiological motion that might occur during a MR-guided HIFU intervention. The authors have shown that such drifts can lead to a misalignment between interventional planning, energy delivery, and therapeutic validation. The presented volunteer study and in vivo experiment demonstrate both the relevance of the problem for HIFU therapies and the compatibility of the proposed motion compensation framework with the workflow of a HIFU intervention under clinical conditions.

60 APPLIED LIFE SCIENCES↗

Respiratory Amplitude Guided 4-Dimensional Magnetic Resonance Imaging

Purpose: To evaluate the feasibility of prospectively guiding 4-dimensional (4D) magnetic resonance imaging (MRI) image acquisition using triggers at preselected respiratory amplitudes to achieve T{sub 2} weighting for abdominal motion tracking. Methods and Materials: A respiratory amplitude-based triggering system was developed and integrated into a commercial turbo spin echo MRI sequence. Initial feasibility tests were performed on healthy human study participants. Four respiratory states, the middle and the end of inhalation and exhalation, were used to trigger 4D MRI image acquisition of the liver. To achieve T{sub 2} weighting, the echo time and repetition time were set to 75 milliseconds and 4108 milliseconds, respectively. Single-shot acquisition, together with parallel imaging and partial k-space imaging techniques, was used to improve image acquisition efficiency. 4D MRI image sets composed of axial or sagittal slices were acquired. Results: Respiratory data measured and logged by the MRI scanner showed that the triggers occurred at the appropriate respiratory levels. Liver motion could be easily observed on both 4D MRI image datasets by sensing either the change of liver in size and shape (axial) or diaphragm motion (sagittal). Both 4D MRI image datasets were T{sub 2}-weighted as expected. Conclusions: This study demonstrated the feasibility of achieving T{sub 2}-weighted 4D MRI images using amplitude-based respiratory triggers. With the aid of the respiratory amplitude-based triggering system, the proposed method is compatible with most MRI sequences and therefore has the potential to improve tumor-tissue contrast in abdominal tumor motion imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Determination of the Precession and Rotation-Rate of Mars from Tracking and Altimetry Data

The doppler tracking of the MGS spacecraft and the laser altimetry acquired by the MOLA instrument on MGS have been used to measure the rotation of Mars. By observing the repeating pattern of gravity anomalies and the topography the direction of the rotation axis in both inertial space and body fixed coordinates, and the rate of rotation of the planet on its axis have been derived. The tracking of MGS in orbit about Mars by stations on Earth permit the orbit of MGS to be obtained in an inertial coordinate system enabling the periodic perturbation of the MGS orbit by Mars' gravity field to be used as a sensor to detect the vector rotation of Mars under the orbit of MGS. The altimetry data acquired by MOLA on MGS permit the topography to help define the orbit of MGS about Mars in a body fixed coordinate system thus enabling the pole of rotation of the planet to be determined in a coordinate system defined by the altimetry. Together they enable the precession of the rotation axis to be observed from which the moment of inertia can be derived, changes in length of day to be measured, and a method to check for possible Mars polar motion. Tracking data on the Mariner 9, Viking 1 and 2, from the 1970's have been analyzed with MGS data obtained in the mapping orbit in 1999 to provide a new estimate of the moment of inertia.

Smith, David E.↗