Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Comparison Between Low-Dose-Rate Brachytherapy With or Without Androgen Deprivation, External Beam Radiation Therapy With or Without Androgen Deprivation, and Radical Prostatectomy With or Without Adjuvant or Salvage Radiation Therapy for High-Risk Prostate Cancer

Purpose: We compare the efficacy and toxicity among the 3 major modalities available used to treat high-risk prostate cancer (HRCaP). Methods and Materials: From 1996 to 2012, 2557 HRCaP patients were treated: 734 received external beam radiation therapy (EBRT) with or without androgen deprivation therapy (ADT), 515 received low-dose-rate prostate brachytherapy (LDR) with or without ADT, and 1308 received radical prostatectomy (RP) with or without EBRT. Biochemical relapse-free survival (bRFS), clinical relapse-free survival (cRFS), and prostate cancer–specific mortality (PCSM) were assessed. Toxicity was assessed using the Common Terminology Criteria for Adverse Events, version 4.03. The log-rank test compared bRFS and cRFS among the modalities, and Cox regression identified factors associated with bRFS and cRFS. Gray's test compared differences in late toxicity and PSCM among the modalities. Competing risk regression identified factors associated with PCSM. Results: The median follow-up time and age were 63.5 months and 65 years, respectively. The bRFS at 5 and 10 years, respectively, was 74% and 53% for EBRT, 74% and 52% for LDR, and 65% and 47% for RP (P=.0001). The cRFS at 5 and 10 years, respectively, was 85% and 73% for EBRT, 90% and 76% for LDR, and 89% and 75% for RP (P=.121). The PCSM at 5 and 10 years, respectively, was 5.3% and 11.2% for EBRT, 3.2% and 3.6% for LDR, and 2.8% and 6.8% for RP (P=.0004). The 10-year cumulative incidence of ≥grade 3 genitourinary toxicity was 8.1% for EBRT, 7.2% for LDR, and 16.4% for RP (P<.0001). The 10-year cumulative incidence of ≥grade 3 gastrointestinal toxicity was 4.6% for EBRT, 1.1% for LDR, and 1.0% for RP (P<.0001). Conclusion: HRCaP treated with EBRT, LDR, or RP yields efficacy showing better bRFS for LDR and EBRT relative to RP, equivalence for cRFS, and a PCSM advantage of LDR and RP over EBRT. The toxicity is lowest for LDR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How to achieve patient-centered testing: role of the protocol nurse

Introduction: Patient-centered cardiac testing is predicated on choosing the right test for the right patient. We studied the effects of changing from script-driven scheduling to nurse-driven protocoling of stress tests. Methods and Results: A protocol nurse reviewed records before scheduling and communicated with patients and ordering providers if needed. We found that instituting nurse protocolling of all non-imaging (ETT) and nuclear (MPI) stress tests (N = 3071) resulted in protocol changes in 37% of our patients, and reduced the proportion of tests that could not be performed as scheduled by 56% and cancelations by 71% (P < 0.001 for each). These changes were sustained over two successive 6-month periods following a baseline observation period of 6 months. For MPI, the most frequent nurse interventions were re-protocoling as stress-first MPI (12% of tests), changing test location for clinical reasons (13%), changing stress modality (7%), and care coordination (5%). Conclusions: Changing from script-driven scheduling to protocol nursing contributed measurably to patient-centered testing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Frequency Domain Methodology for Quantitative Evaluation of Diffuse Wavefield With Applications to Seismic Imaging

Abstract Ambient Noise Imaging (ANI) of subsurface structures relies on seismic interferometry of diffuse seismic wavefields. However, the lack of effective methods to quantify and identify highly diffuse waves hampers applications of ANI, particularly in evaluating seismic attenuation and monitoring structural changes with high temporal resolution. Conventional ANI approaches require data normalization, which effectively suppresses the non‐diffuse component with large amplitude but also results in significant loss of amplitude and phase information in the continuous seismic records. In this study, we propose a frequency domain method to quantitatively evaluate the degree of diffuseness of seismic wavefields by analyzing their statistical characteristics of modal amplitudes for stationarity and randomness. Tests on synthetic waveform and field nodal records show that the proposed method can effectively distinguish between diffuse and non‐diffuse waveforms for either single‐ or three‐component data. As an application, we identify a 60‐s‐long diffuse coda of a local M 2.2 earthquake recorded by a dense nodal array on the San Jacinto Fault Zone, and successfully extract high‐quality dispersion curve andQ‐value without performing data normalization. These results are consistent with those obtained by conventional methods that assess the correlation between coherency and the Green's function, and by modeling ballistic waves generated by road traffic. Our proposed method can advance the imaging of subsurface velocity and attenuation structures as well as monitoring temporal changes for scientific studies and engineering applications.

Geochemistry & Geophysics↗

Quantitative phase imaging by gradient retardance optical microscopy

Abstract Quantitative phase imaging (QPI) has become a vital tool in bioimaging, offering precise measurements of wavefront distortion and, thus, of key cellular metabolism metrics, such as dry mass and density. However, only a few QPI applications have been demonstrated in optically thick specimens, where scattering increases background and reduces contrast. Building upon the concept of structured illumination interferometry, we introduce Gradient Retardance Optical Microscopy (GROM) for QPI of both thin and thick samples. GROM transforms any standard Differential Interference Contrast (DIC) microscope into a QPI platform by incorporating a liquid crystal retarder into the illumination path, enabling independent phase-shifting of the DIC microscope's sheared beams. GROM greatly simplifies related configurations, reduces costs, and eradicates energy losses in parallel imaging modalities, such as fluorescence. We successfully tested GROM on a diverse range of specimens, from microbes and red blood cells to optically thick (~ 300 μm) plant roots without fixation or clearing.

47 OTHER INSTRUMENTATION↗

4D Multimodal Co-attention Fusion Network with Latent Contrastive Alignment for Alzheimer’s Diagnosis

Multimodal neuroimaging provides complementary structural and functional insights into both human brain organization and disease-related dynamics. Recent studies demonstrate enhanced diagnostic sensitivity for Alzheimer’s disease (AD) through synergistic integration of neuroimaging data (e.g., sMRI, fMRI) with tabular data (e.g., behavioral and cognitive tests). However, the intrinsic heterogeneity across modalities (e.g., 4D spatiotemporal fMRI dynamics vs. 3D anatomical sMRI structure) presents critical challenges for discriminative feature fusion, often leading to information loss or biased fusion. To bridge this gap, we propose M2M-AlignNet: a multimodal co-attention network with latent alignment for early AD diagnosis using sMRI and fMRI. At the core of our approach is a multi-patch-to-multi-patch (M2M) contrastive loss function that quantifies and reduces representational discrepancies via weighted patch correspondence, explicitly aligning fMRI components across brain regions with their sMRI structural substrates without one-to-one constraints. Additionally, we propose a latent-as-query co-attention module to autonomously discover fusion patterns, circumventing modality prioritization biases while minimizing feature redundancy. We conduct extensive experiments to confirm the effectiveness of our method and highlight the correspondence between fMRI and sMRI as AD biomarkers.

Wei, Yuxiang [Georgia Institute of Technology]↗

Development of a PET/Cerenkov-light hybrid imaging system

Purpose: Cerenkov-light imaging is a new molecular imaging technology that detects visible photons from high-speed electrons using a high sensitivity optical camera. However, the merit of Cerenkov-light imaging remains unclear. If a PET/Cerenkov-light hybrid imaging system were developed, the merit of Cerenkov-light imaging would be clarified by directly comparing these two imaging modalities. Methods: The authors developed and tested a PET/Cerenkov-light hybrid imaging system that consists of a dual-head PET system, a reflection mirror located above the subject, and a high sensitivity charge coupled device (CCD) camera. The authors installed these systems inside a black box for imaging the Cerenkov-light. The dual-head PET system employed a 1.2 × 1.2 × 10 mm{sup 3} GSO arranged in a 33 × 33 matrix that was optically coupled to a position sensitive photomultiplier tube to form a GSO block detector. The authors arranged two GSO block detectors 10 cm apart and positioned the subject between them. The Cerenkov-light above the subject is reflected by the mirror and changes its direction to the side of the PET system and is imaged by the high sensitivity CCD camera. Results: The dual-head PET system had a spatial resolution of ∼1.2 mm FWHM and sensitivity of ∼0.31% at the center of the FOV. The Cerenkov-light imaging system's spatial resolution was ∼275μm for a {sup 22}Na point source. Using the combined PET/Cerenkov-light hybrid imaging system, the authors successfully obtained fused images from simultaneously acquired images. The image distributions are sometimes different due to the light transmission and absorption in the body of the subject in the Cerenkov-light images. In simultaneous imaging of rat, the authors found that {sup 18}F-FDG accumulation was observed mainly in the Harderian gland on the PET image, while the distribution of Cerenkov-light was observed in the eyes. Conclusions: The authors conclude that their developed PET/Cerenkov-light hybrid imaging system is useful to evaluate the merits and the limitations of Cerenkov-light imaging in molecular imaging research.

60 APPLIED LIFE SCIENCES↗

Multiparameter fiber optic sensing system for monitoring enhanced geothermal systems

The goal of this project was to design, fabricate and test an optical fiber cable which supports multiple sensing modalities for measurements in the harsh environment of enhanced geothermal systems. To accomplish this task, optical fiber was tested at both high temperatures and strains for mechanical integrity, and in the presence of hydrogen for resistance to darkening. Both single mode (SM) and multimode (MM) commercially available optical fiber were identified and selected for the cable based on the results of these tests. The cable was designed and fabricated using a tube-within-tube construction containing two MM fibers and one SM fiber, and without supporting gel that is not suitable for high temperature environments. Commercial fiber optic sensing instruments using Raman DTS (distributed temperature sensing), Brillouin DTSS (distributed temperature and strain sensing), and Raleigh COTDR (coherent optical time domain reflectometry) were selected for field testing.

15 GEOTHERMAL ENERGY↗

Data fusion in X-ray computed tomography using a superiorization approach

X-ray computed tomography (CT) is an important and widespread inspection technique in industrial non-destructive testing. However, large-sized and heavily absorbing objects cause artifacts due to either the lack of penetration of the specimen in specific directions or by having data from only a limited angular range of views. In such cases, valuable information about the specimen is not revealed by the CT measurements alone. Further imaging modalities, such as optical scanning and ultrasonic testing, are able to provide data (such as an edge map) that are complementary to the CT acquisition. In this paper, a superiorization approach (a newly developed method for constrained optimization) is used to incorporate the complementary data into the CT reconstruction; this allows precise localization of edges that are not resolvable from the CT data by itself. Superiorization, as presented in this paper, exploits the fact that the simultaneous algebraic reconstruction technique (SART), often used for CT reconstruction, is resilient to perturbations; i.e., it can be modified to produce an output that is as consistent with the CT measurements as the output of unmodified SART, but is more consistent with the complementary data. The application of this superiorized SART method to measured data of a turbine blade demonstrates a clear improvement in the quality of the reconstructed image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of dynamic patterns of an elastic membrane at bi-modal vibration using high speed electronic speckle pattern interferometry

Implementing a hybrid arrangement of Laser Doppler Vibrometry (LDV) and high speed Electronic Speckle Pattern Interferometry (ESPI) we were able to measure the dynamic patterns of a flat rectangular elastic membrane clamped at its edges stimulated with the sum of two resonance frequencies. ESPI is a versatile technique to analyze in real-time the deformation of a membrane since its low computational cost and easy implementation of the optical setup. Elastic membranes present nonlinear behaviors when stimulated with low amplitude signals. The elastic membrane under test, with several non rational related vibrating modals below the 200 Hz, was stimulated with two consecutives resonant frequencies. The ESPI patterns, acquired at high speed rates, shown a similar behavior for the dual frequency stimulation as in the case of patterns formed with the entrainment frequency. We think this may be related to the effects observed in the application of dual frequency stimulation in ultrasound.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Is the testing effect ready to be put to work? Evidence from the laboratory to the classroom.

The testing effect refers to the benefits to retention that result from structuring learning activities in the form of a test. As educators consider implementing test-enhanced learning paradigms in real classroom environments, we think it is critical to consider how an array of factors affecting test-enhanced learning in laboratory studies bear on test-enhanced learning in real-world classroom environments. As such, this review discusses the degree to which test feedback, test format (of formative tests), number of tests, level of the test questions, timing of tests (relative to initial learning), and retention duration have import for testing effects in ecologically valid contexts (e.g., classroom studies). Attention is also devoted to characteristics of much laboratory testing-effect research that may limit translation to classroom environments, such as the complexity of the material being learned, the value of the testing effect relative to other generative learning activities in classrooms, an educational orientation that favors criterial tests focused on transfer of learning, and online instructional modalities. We consider how student-centric variables present in the classroom (e.g., cognitive abilities, motivation) may have bearing on the effects of testing-effect techniques implemented in the classroom. We conclude that the testing effect is a robust phenomenon that benefits a wide variety of learners in a broad array of learning domains. Still, studies are needed to compare the benefit of testing to other learning strategies, to further characterize how individual differences relate to testing benefits, and to examine whether testing benefits learners at advanced levels.

60 APPLIED LIFE SCIENCES↗

An ECT/ERT dual-modality sensor for oil-water two-phase flow measurement

This paper presents a new sensor for ECT/ERT dual-modality system which can simultaneously obtain the permittivity and conductivity of the materials in the pipeline. Quasi-static electromagnetic fields are produced by the inner electrodes array sensor of electrical capacitance tomography (ECT) system. The results of simulation show that the data of permittivity and conductivity can be simultaneously obtained from the same measurement electrode and the fusion of two kinds of data may improve the quality of the reconstructed images. For uniform oil-water mixtures, the performance of designed dual-modality sensor for measuring the various oil fractions has been tested on representative data and the results of experiments show that the designed sensor broadens the measurement range compared to single modality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensor Fusion Techniques for Phased-Array Eddy Current and Phased-Array Ultrasound Data

Sensor (or Data) fusion is the process of integrating multiple data sources to produce more consistent, accurate and comprehensive information than is provided by a single data source. Sensor fusion may also be used to combine multiple signals from a single modality to improve the performance of a particular inspection technique. Industrial nondestructive testing may utilize multiple sensors to acquire inspection data depending upon the object under inspection and the anticipated types of defects that can be identified. Sensor fusion can be performed at various levels of signal abstraction with each having its strengths and weaknesses. A multimodal data fusion strategy first proposed by Heideklang and Shokouhi that combines spatially scattered detection locations to improve detection performance of surface-breaking and near-surface cracks in ferromagnetic metals is shown using a surface inspection example and is then extended for volumetric inspections. Utilizing data acquired from an Olympus Omniscan MX2 from both phased array eddy current and ultrasound probes on test phantoms, single and multilevel fusion techniques are employed to integrate signals from the two modalities. Preliminary results demonstrate how confidence in defect identification and interpretation benefit from sensor fusion techniques. Lastly, techniques for integrating data into radiographic and volumetric imagery from computed tomography are described and results are presented.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Development Of Chemical Reduction And Air Stripping Processes To Remove Mercury From Wastewater

This study evaluates the removal of mercury from wastewater using chemical reduction and air stripping using a full-scale treatment system at the Savannah River Site. The existing water treatment system utilizes air stripping as the unit operation to remove organic compounds from groundwater that also contains mercury (C ~ 250 ng/L). The baseline air stripping process was ineffective in removing mercury and the water exceeded a proposed limit of 51 ng/L. To test an enhancement to the existing treatment modality a continuous dose of reducing agent was injected for 6-hours at the inlet of the air stripper. This action resulted in the chemical reduction of mercury to Hg(0), a species that is removable with the existing unit operation. During the injection period a 94% decrease in concentration was observed and the effluent satisfied proposed limits. The process was optimized over a 2-day period by sequentially evaluating dose rates ranging from 0.64X to 297X stoichiometry. A minimum dose of 16X stoichiometry was necessary to initiate the reduction reaction that facilitated the mercury removal. Competing electron acceptors likely inhibited the reaction at the lower 1 doses, which prevented removal by air stripping. These results indicate that chemical reduction coupled with air stripping can effectively treat large-volumes of water to emerging part per trillion regulatory standards for mercury.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fluorescence excitation and propagation through brain phantom gelatins: measurements and potential applications

We have investigated the utility of 0.6% agarose gels as surrogate materials for brain tissues in optical propagation studies for possible diagnostic and therapeutic applications. Centimeter-scale layers of the gel exhibited a Beer's law attenuation factor, , of 0.2 mm 1 for incident illumination via a pulsed LED (100 Hz) at 405 nm. This result was different by only about a factor of 3 from the effective penetration depth at similar wavelengths through in vitro samples of the gray (cortical) matter of human brain, as measured by others. Then, films of the thermographic phosphors La2O2S:Eu, Mg4FGeO6:Mn, YAG:Cr and variants of the latter were formed on aluminum substrates and the fluorescence of these samples was stimulated and observed through layers of the gel up to 4 cm thick. In all cases, the fluorescence was easily excited and distinguishable above the background. The results demonstrate that this gel might serve as an inexpensive and robust test bed for exploratory studies of neurological modalities involving propagation of optical signals within brain tissues.

60 APPLIED LIFE SCIENCES↗