Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Phonon gas model for thermal conductivity of dense, strongly interacting liquids

Developing predictive thermal property models for liquids based on microscopic principles has been elusive. The difficulty is that liquids have gas-like and solid-like attributes that are at odds when considering the frameworks of microscopic models: Models for gases are simple due to randomness and low density, whereas models for crystalline solids rely on symmetry and long-range order for easier calculation. The short-range order in liquids does, however, provide structure to neighboring molecules similar to amorphous solids, and there have been recent advances indicating that collective vibrational modes store heat in liquids. Models combining Debye approximations from solid-state physics and Frenkel’s theory of liquids can accurately predict the heat capacity of liquids. Phonon-like dispersions in liquids have also been widely observed in neutron scattering experiments. These developments motivate us to propose a model where high-frequency vibrational modes, which travel at the speed of sound and have a mean free path on the order of the average intermolecular distance, conduct heat in liquids. We use this liquid phonon gas model to calculate the thermal conductivity of liquids with varying intermolecular interaction energies from strongest to weakest—Coulomb, hydrogen-bonding, Keesom, and London dispersion energy. Generally, the model is more accurate as the intermolecular interaction energy and density of liquids increase. The calculated thermal conductivity of Coulombic-bound molten sodium nitrate and hydrogen-bonded water is within 1.46% and 2.98% of the experimentally measured values, respectively, across their entire temperature ranges. Further modal analysis of the velocity and the mean free path of collective vibrations could establish the liquid phonon gas model as an accurate model for weakly interacting liquids as well.

36 MATERIALS SCIENCE↗

Thermally activated nucleation and growth of cobalt and nickel oxide nanoparticles on porous silica

Integrating mesoscale to the molecular level understanding of nanoparticle nucleation phenomena can drive the bottom-up synthesis approach for target applications. In this work, we studied the thermal evolution of cobalt and nickel oxide nanoparticle structural phases on porous silica host from over wide spatial scale using multi-modal analysis involving scanning transmission electron microscope (STEM), X-ray absorption (XANES) and nuclear magnetic resonance (NMR) spectroscopies along with density functional theory (DFT) based calculations. The TEM analysis reveals thermally activated nanoparticle clustering and subsequent interaction with the porous host material. The Co and Ni K-edge XANES spectra revealed the evolution from metal hydroxide to metal oxide and subsequently metal silicate composites with calcinination temperature. 29 Si NMR analysis revealed the role of surface functional groups of silica host for silicate composite formation which is corroborated by DFT studies.

36 MATERIALS SCIENCE↗

Velo and REXAN - Integrated Data Management and High Speed Analysis for Experimental Facilities

The Chemical Imaging Initiative at the Pacific Northwest National Laboratory (PNNL) is creating a ‘Rapid Experimental Analysis’ (REXAN) Framework, based on the concept of reusable component libraries. REXAN allows developers to quickly compose and customize high throughput analysis pipelines for a range of experiments, as well as supporting the creation of multi-modal analysis pipelines. In addition, PNNL has coupled REXAN with its collaborative data management and analysis environment Velo to create an easy to use data management and analysis environments for experimental facilities. This paper will discuss the benefits of Velo and REXAN in the context of three examples: PNNL High Resolution Mass Spectrometry - reducing analysis times from hours to seconds, and enabling the analysis of much larger data samples (100KB to 40GB) at the same time · ALS X-Ray tomography - reducing analysis times of combined STXM and EM data collected at the ALS from weeks to minutes, decreasing manual work and increasing data volumes that can be analysed in a single step ·Multi-modal nano-scale analysis of STXM and TEM data - providing a semi automated process for particle detection The creation of REXAN has significantly shortened the development time for these analysis pipelines. The integration of Velo and REXAN has significantly increased the scientific productivity of the instruments and their users by creating easy to use data management and analysis environments with greatly reduced analysis times and improved analysis capabilities.

Kleese van Dam, Kerstin↗

Characterizing the Oscillatory Properties of Bulk Electric Systems

This paper presents a process for characterizing the oscillatory dynamics of a large bulk power system. As a demonstration, the process is applied to the Western Interconnection of North America. Several complementary analysis approaches, both new and existing, are employed to provide a comprehensive understanding of the oscillatory properties of the system. Established modal analysis techniques based on ringdown and mode-meter algorithms are utilized. In addition, we derive and apply methods based on spectral correlation analysis to identify modal frequencies, distinguish between modes that are closely spaced in frequency, and determine locations at which the modes are observable. Critical interarea modes are identified and characterized using actual-system synchrophasor measurements taken over several years of operation in concert with industry-standard simulation models. This includes 145 hours of PMU data and two planning base cases.

42 ENGINEERING↗

Multi-mode quasi-static excitation for systems with nonlinear joints

Finite element models can be used to model and predict the hysteresis and energy dissipation exhibited by nonlinear joints in structures. As a result of the nonlinearity, the frequency and damping of a mode is dependent on excitation amplitude, and when the modes remain uncoupled, quasi-static modal analysis has been shown to efficiently predict this behavior. However, in some cases the modes have been observed to couple such that the frequency and damping of one mode is dependent on the amplitude of other modes. To model the interactions between modes, one must integrate the dynamic equations in time, which is several orders of magnitude more expensive than quasi-static analysis. This work explores an alternative where quasi-static forces are applied in the shapes of two or more modes of vibration simultaneously, and the resulting load–displacement curves are used to deduce the effect of other modes on the effective frequency and damping of the mode in question. This methodology is demonstrated on a simple 2D cantilever beam structure with a single bolted joint which exhibits micro-slip nonlinearity over a range of vibration amplitudes. The predicted frequency and damping are compared with those extracted from a few expensive dynamic simulations of the structure, showing that the quasi-static approach produces reasonable albeit highly conservative bounds on the observed dynamics. This framework is also demonstrated on a 3D structure where dynamic simulations are infeasible.

42 ENGINEERING↗

Quantify Resonance Inspection with Finite Element-Based Modal Analyses

Resonance inspection uses the natural acoustic resonances of a part to identify anomalous parts. Modern instrumentation can measure the many resonant frequencies rapidly and accurately. Sophisticated sorting algorithms trained on sets of good and anomalous parts can rapidly and reliably inspect and sort parts. This paper aims at using finite-element-based modal analysis to put resonance inspection on a more quantitative basis. A production-level automotive steering knuckle is used as the example part for our study. First, the resonance frequency spectra for the knuckle are measured with two different experimental techniques. Next, scanning laser vibrometry is used to determine the mode shape corresponding to each resonance. The material properties including anisotropy are next measured to high accuracy using resonance spectroscopy on cuboids cut from the part. Then, finite element model (FEM) of the knuckle is generated by meshing the actual part geometry obtained with computed tomography (CT). The resonance frequencies and mode shapes are next predicted with a natural frequency extraction analysis after extensive mesh size sensitivity study. The good comparison between the predicted and the experimentally measured resonance spectra indicate that finite-element-based modal analyses have the potential to be a powerful tool in shortening the training process and improving the accuracy of the resonance inspection process for a complex, production level part. The finite element based analysis can also provide a means to computationally test the sensitivity of the frequencies to various possible defects such as porosity or oxide inclusions especially in the high stress regions that the part will experience in service.

42 ENGINEERING↗

Quantify Resonance Inspection with Finite Element-Based Modal Analyses

Resonance inspection uses the natural acoustic resonances of a part to identify anomalous parts. Modern instrumentation can measure the many resonant frequencies rapidly and accurately. Sophisticated sorting algorithms trained on sets of good and anomalous parts can rapidly and reliably inspect and sort parts. This paper aims at using finite-element-based modal analysis to put resonance inspection on a more quantitative basis. A production-level automotive steering knuckle is used as the example part for our study. First, the resonance frequency spectra for the knuckle are measured with two different experimental techniques. Next, scanning laser vibrometry is used to determine the mode shape corresponding to each resonance. The material properties including anisotropy are next measured to high accuracy using resonance spectroscopy on cuboids cut from the part. Then, finite element model (FEM) of the knuckle is generated by meshing the actual part geometry obtained with computed tomography (CT). The resonance frequencies and mode shapes are next predicted with a natural frequency extraction analysis after extensive mesh size sensitivity study. The good comparison between the predicted and the experimentally measured resonance spectra indicate that finite-element-based modal analyses have the potential to be a powerful tool in shortening the training process and improving the accuracy of the resonance inspection process for a complex, production level part. The finite element based analysis can also provide a means to computationally test the sensitivity of the frequencies to various possible defects such as porosity or oxide inclusions especially in the high stress regions that the part will experience in service.

99 GENERAL AND MISCELLANEOUS↗

Seismic Assessment of Buildings: Proposal of a New Modified Uncoupled Modal Response History Analysis

This paper develops a new modified uncoupled modal response history analysis (M-UMRHA) in order to study the seismic behavior of structures. It aims to provide an acceptable accuracy with reduced calculation duration in comparison to complete analysis, i.e. the THA. The proposed method improves the existing UMRHA, developed by Chopra and Goel [1], by considering an energy based approach to build the capacity curve [2] and a pseudo-adaptive feature to account for changes in modal shapes after yielding, motivated by an adaptive method [3]. Validation is made by comparison with NLTHA as well as other simplified methods. Low and medium-rise RC buildings were analyzed under real ground motion records. Results show good estimates of structural parameters and give good correlation between damage and story displacements as well as drifts. Like other simplified methods, accuracy decreases in the inelastic domain. However, this procedure gives acceptable estimates of structural response with a few additional calculations and it has the potential to be used in large scale studies, and probabilistic approaches.

42 ENGINEERING↗

Impeller deflection and modal finite element analysis.

Deflections of an impeller due to centripetal forces are calculated using finite element analysis. The lateral, or out of plane, deflections are an important design consideration for this particular impeller because it incorporates an air bearing with critical gap tolerances. The target gap distance is approximately 10 microns at a rotational velocity of 2500 rpm. The centripetal forces acting on the impeller cause it deflect in a concave fashion, decreasing the initial gap distance as a function of radial position. This deflection is characterized for a previous and updated impeller design for comparative purposes. The impact of design options such as material selection, geometry dimensions, and operating rotational velocity are also explored, followed by a sensitivity study with these parameters bounded by specific design values. A modal analysis is also performed to calculate the impeller's natural frequencies which are desired to be avoided during operation. The finite element modeling techniques continue to be exercised by the impeller design team to address specific questions and evaluate conceptual designs, some of which are included in the Appendix.

Spencer, Nathan A.↗

SDynPy: A Structural Dynamics Python Library

SAND2023-11957O SDynPy software can be used in digital signal processing, modal analysis, and geometry algorithms that are available in open literature, specifically the Synthesize Modes and Correlate and polynomial-based multiple reference modal fitters. This software can be used to perform structural dynamic testing and analysis. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Rohe, Daniel↗

Transport of DESY 1.3 GHZ Cryomodule at Fermilab

In an exchange of technology agreement, Deutsches Elektron-Synchrotron (DESY) Laboratory in Hamburg Germany has provided a 1.3 GHz cryomodule 'kit' to Fermilab. The cryomodule components (qualified dressed cavities, cold mass parts, vacuum vessel, etc.) sent from Germany in pieces were assembled at Fermilab's Cryomodule Assembly Facility (CAF). The cavity string was assembled at CAF-MP9 Class 10 cleanroom and then transported to CAF-ICB cold mass assembly area via a flatbed air ride truck. Finite Element Analysis (FEA) studies were implemented to define location of instrumentation for initial cold mass transport, providing modal frequencies and shapes. Subsequently, the fully assembled cryomodule was transported to the SRF Accelerator Test Facility at New Muon Lab (NML). Internal geophones (velocity sensors) were attached during the coldmass assembly for transport (warm) and operational (cold) measurements. A description of the isolation system that maintained alignment during transport and protected fragile components is provided. Shock and vibration measurement results of each transport and modal analysis are discussed.

43 PARTICLE ACCELERATORS↗

Development of a new methodology for stability analysis in BWR NPP

In this work, a new methodology to reproduce power oscillations in BWR NPP is presented. This methodology comprises the modal analysis techniques, the signal analysis techniques and the simulation with the coupled code RELAP5/PARCSv2.7. Macroscopic cross sections are obtained by using the SIMTAB methodology, which is fed up with CASMO-4/SIMULATE-3 data. The input files for the neutronic and thermohydraulic codes are obtained automatically and the thermalhydraulic-to-neutronic representation (mapping) used is based on the fundamental, first and second harmonics shapes of the reactor power, calculated with the VALKIN code (developed in UPV). This mapping was chosen in order not to condition the oscillation pattern. To introduce power oscillations in the simulation a new capability in the coupled code, for generate density perturbations (both for the whole core and for chosen axial levels) according with the power modes shapes, has been implemented. The purpose of the methodology is to reproduce the driving mechanism of the out of phase oscillations appeared in BWR type reactors. In this work, the methodology is applied to the Record 9 point, collected in the NEA benchmark of Ringhals 1 NPP. A set of different perturbations are induced in the first active axial level and the LPRM signals resulting are analyzed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nonlocal Analysis of Natural Vibrations of Carbon Nanotubes

When the atomic level is considered, the dynamic properties have a major influence on nanostructures behavior because of their ultrahigh or very high natural frequencies. Vibrations are essential in the analysis of resonators, oscillators, and sensors for carbon nanotube-based devices. The present paper is dedicated to the eigenfrequencies analysis of single-walled carbon nanotubes. In the analysis, the small-scale coefficient is introduced, and the nonlocal elasticity theory is applied in the modal analysis of the carbon nanotubes. The correlation between nonlocal small-scale parameter and the vibrational behavior of the carbon nanotubes is studied. The determination of nonlocal parameter is based on the structural finite element model of the nanotube. A detailed parametric study is realized to investigate the effects of the length-to-diameter ratio L/D, nonlocal coefficient, the influence of boundary conditions on eigenfrequencies of carbon nanotubes. The main contribution of this work is the evaluation of the nonlocal parameter for single-walled carbon nanotubes based on the finite element approximation in modeling the dynamic behavior instead of commonly used MD simulations. It was clearly displayed that the application of the nonlocal beam models involves analysis of the small-scale parameter, whose value determines the final eigenfrequencies. The highest values of eigenfrequencies were observed for the local beam model. It was presented that the eigenfrequencies for carbon nanotubes decrease when the nanotube length increases for all analyzed modes. On the other hand, when the diameter of carbon nanotubes increases, the eigenfrequency values rise. The numerical validation of the nonlocal parameter revealed the high dependence on the boundary conditions and the mode number. However, the influence of the mode number and the boundary conditions is vanishing for long single-walled carbon nanotubes.

36 MATERIALS SCIENCE↗

Algorithm for Screening Phasor Measurement Unit Data for Power System Events and Categories and Common Characteristics for Events Seen in Phasor Measurement Unit Relative Phase-Angle Differences and Frequency Signals

A network of multiple phasor measurement units (PMU) was created, set up, and maintained at the University of Texas at Austin to obtain actual power system measurements for power system analysis. Power system analysis in this report covers a variety of time ranges, such as short- term analysis for power system disturbances and their effects on power system behavior and long- term power system behavior using modal analysis. The first objective of this report is to screen the PMU data for events. The second objective of the report is to identify and describe common characteristics extracted from power system events as measured by PMUs. The numerical characteristics for each category and how these characteristics are used to create selection rules for the algorithm are also described. Trends in PMU data related to different levels and fluctuations in wind power output are also examined.

17 WIND ENERGY↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative Small-Signal Stability Analysis of Grid-Forming Inverters in Large-Scale Power Systems

In this paper, the challenges induced by the integration of inverter-based resources (IBRs) into existing power systems are discussed. Although the grid-forming (GFM) control has been used to enhance system performance in multiple sections of electric power systems (e.g., transmission and distribution systems, microgrids, among others), the coupling mechanism between GFM inverter and various types of other components in modern power systems should be clearly explored. Existing analyses mainly focus on qualitative investigations that verify the effectiveness of deploying GFM inverters for stability enhancement. A holistic system-level quantitative analysis is still missing to verify the detailed benefits of GFM inverters and their interactions with other generation units (e.g., synchronous generators [SGs], conventional grid-following [GFL] inverters, synchronous condensers, among others). To fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established along with the customized power flow analysis for varying steady-state operating points. Further, a quantitative method is proposed to identify the impacts of GFM inverters on system performance with an emphasis on a quantifiable stability margin and a complete modal analysis at the system level. Finally, a realistic test system is used to verify the proposed approach.

grid-following↗