Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microfluidic devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Oxygenates production in a microfluidic dielectric barrier discharge device sustained in Ar/CH 4 /O 2

Reforming of methane (CH 4 ) is a process to produce syngas (CO/H 2 ) and other value-added chemicals including oxygenates such as methanol (CH 3 OH). Atmospheric pressure plasmas have the potential to be more energy efficient than traditional reforming methods as value-added chemicals can be synthesized directly in the plasma without requiring an additional step. In this paper, we discuss the results from a computational investigation of the formation of oxygenates by CH 4 oxidation in the presence of Ar, including CH 3 OH and CH 2 O, in a nanosecond pulsed dielectric barrier discharge. The plasma is formed in a microfluidic channel whose small dimensions are ideal for plasma formation at atmospheric pressure. The production and consumption mechanisms of dominant radicals and long-lived species are discussed in detail for the base case conditions of Ar/CH 4 /O 2 = 50/25/25. CH 3 OH is produced primarily by CH 3 O reacting with CH 3 O and CH 3 O 2 reacting with OH, while CH 2 O formation relies on reactions involving CH 3 O and CH 3 . The most abundant oxygenate formed is CO (produced by H abstraction from CHO). However, the greenhouse gas CO 2 is also formed as a by-product. The effects of gas mixture are examined to maximize the CH 3 OH and CH 2 O densities while decreasing the CO 2 density. Increasing the Ar percentage from 0% to 95% decreased the CH 3 OH and CH 2 O densities. At low Ar percentages, this is due to an increase in consumption of CH 3 OH and CH 2 O, while at high Ar percentages (>40% Ar), the production of CH 3 OH and CH 2 O is decreased. However, both CO and CO 2 reached peak densities at 70%–90% Ar. Changing the CH 4 /O 2 ratio while keeping 50% Ar in the discharge led to increased CH 3 OH and CH 2 O production, reaching peak densities at 35%–40% CH 4 . The CO and CO 2 densities decreased beyond 20% CH 4 , indicating that a CH 4 rich discharge is ideal for forming the desired oxygenates.

03 NATURAL GAS↗

Design and Modelling of a Microfluidic Electro-Lysis Device with Controlling Plates

Many Lab-on-Chip applications require sample pre-treatment systems. Using electric fields to perform cell-lysis in bio-MEMS systems has provided a powerful tool which can be integrated into Lab-on-a-Chip platforms. The major design considerations for electro-lysis devices include optimal geometry and placement of micro-electrodes, cell concentration, flow rates, optimal electric field (e.g. pulsed DC vs. AC), etc. To avoid electrolysis of the flowing solution at the exposed electrode surfaces, magnitudes and the applied voltages and duration of the DC pulse, or the AC frequency of the AC, have to be optimized for a given configuration. Using simulation tools for calculation of electric fields has proved very useful, for exploring alternative configurations and operating conditions for achieving electro cell-lysis. To alleviate the problem associated with low electric fields within the microfluidics channel and the high voltage demand on the contact electrode strips, two "control plates" are added to the microfluidics configuration. The principle of placing the two controlling plate-electrodes is based on the electric fields generated by a combined insulator/dielectric (gladwater) media. Surface charges are established at the insulator/dielectric interface. This paper discusses the effects of this interface charge on the modification of the electric field of the flowing liquid/cell solution.

Jenkins, A.↗

Spectroscopy imaging and analysis of live cells

Disclosed herein are systems, methods, systems and devices for measurement and visualization of chemical dynamics in living cells or tissues for diagnostic pathology. Devices can be open- or closed-channel microfluidic membrane devices for long-term IR spectroscopy of live adherent cells and ultimately for rapidly identifying time-dependent spectral features indicative of chemical abnormality in individual cells.

Holman, Hoi-Ying N.↗

Inventions Utilizing Microfluidics and Colloidal Particles

Several related inventions pertain to families of devices that utilize microfluidics and/or colloidal particles to obtain useful physical effects. The families of devices can be summarized as follows: (1) Microfluidic pumps and/or valves wherein colloidal-size particles driven by electrical, magnetic, or optical fields serve as the principal moving parts that propel and/or direct the affected flows. (2) Devices that are similar to the aforementioned pumps and/or valves except that they are used to manipulate light instead of fluids. The colloidal particles in these devices are substantially constrained to move in a plane and are driven to spatially order them into arrays that function, variously, as waveguides, filters, or switches for optical signals. (3) Devices wherein the ultra-laminar nature of microfluidic flows is exploited to effect separation, sorting, or filtering of colloidal particles or biological cells in suspension. (4) Devices wherein a combination of confinement and applied electrical and/or optical fields forces the colloidal particles to become arranged into three-dimensional crystal lattices. Control of the colloidal crystalline structures could be exploited to control diffraction of light. (5) Microfluidic devices, incorporating fluid waveguides, wherein switching of flows among different paths would be accompanied by switching of optical signals.

Marr, David W.↗

Replaceable Microfluidic Cartridges for a PCR Biosensor

The figure depicts a replaceable microfluidic cartridge that is a component of a miniature biosensor that detects target deoxyribonucleic acid (DNA) sequences. The biosensor utilizes (1) polymerase chain reactions (PCRs) to multiply the amount of DNA to be detected, (2) fluorogenic polynucleotide probe chemicals for labeling the target DNA sequences, and (3) a high-sensitivity epifluorescence-detection optoelectronic subsystem. Microfluidics is a relatively new field of device development in which one applies techniques for fabricating microelectromechanical systems (MEMS) to miniature systems for containing and/or moving fluids. Typically, microfluidic devices are microfabricated, variously, from silicon or polymers. The development of microfluidic devices for applications that involve PCR and fluorescence-based detection of PCR products poses special challenges

Francis, Kevin↗

Sub-micron surface plasmon resonance sensor systems

Wearable or implantable devices combining microfluidic control of sample and reagent flow and micro-cavity surface plasmon resonance sensors functionalized with surface treatments or coatings capable of specifically binding to target analytes, ligands, or molecules in a bodily fluid are provided. The devices can be used to determine the presence and concentration of target analytes in the bodily fluids and thereby help diagnose, monitor or detect changes in disease conditions.

Glazier, James A.↗

Nanoscale Surface Plasmonics Sensor With Nanofluidic Control

Conventional quantitative protein assays of bodily fluids typically involve multiple steps to obtain desired measurements. Such methods are not well suited for fast and accurate assay measurements in austere environments such as spaceflight and in the aftermath of disasters. Consequently, there is a need for a protein assay technology capable of routinely monitoring proteins in austere environments. For example, there is an immediate need for a urine protein assay to assess astronaut renal health during spaceflight. The disclosed nanoscale surface plasmonics sensor provides a core detection method that can be integrated to a lab-on-chip device that satisfies the unmet need for such a protein assay technology. Assays based upon combinations of nanoholes, nanorings, and nanoslits with transmission surface plasmon resonance (SPR) are used for assays requiring extreme sensitivity, and are capable of detecting specific analytes at concentrations as low as picomole to femtomole level in well-controlled environments. The device operates in a transmission mode configuration in which light is directed at one planar surface of the array, which functions as an optical aperture. The incident light induces surface plasmon light transmission from the opposite surface of the array. The presence of a target analyte is detected by changes in the spectrum of light transmitted by the array when a target analyte induces a change in the refractive index of the fluid within the nanochannels. This occurs, for example, when a target analyte binds to a receptor fixed to the walls of the nanochannels in the array. Independent fluid handling capability for individual nanoarrays on a nanofluidic chip containing a plurality of nanochannel arrays allows each array to be used to sense a different target analyte and/or for paired arrays to analyze control and test samples simultaneously in parallel. The present invention incorporates transmission mode nanoplasmonics and nanofluidics into a single, microfluidically controlled device. The device comprises one or more arrays of aligned nanochannels that are in fluid communication with inflowing and outflowing fluid handling manifolds that control the flow of fluid through the arrays. The array acts as an aperture in a plasmonic sensor. Fluid, in the form of a liquid or a gas and comprising a sample for analysis, is moved from an inlet manifold through the nanochannel array, and out through an exit manifold. The fluid may also contain a reagent used to modify the interior surfaces of the nanochannels, and/or a reagent required for the detection of an analyte.

Wei, Jianjun↗

3D Printing of Transparent Silicone Elastomers

Here in this paper, inks for transparent elastomers that are formulated by matching the refractive index of silica and polysiloxanes are described. The transparent inks transmit up to ≈90% of 700 nm light through 1 cm and remain transparent when solidified. The inks and solidified materials exhibit a thermochromic effect. This thermochromic effect can be controlled by the refractive index mismatch. Transparency may increase or decrease as temperature increases, depending on the refractive index mismatch of the base polysiloxane and silica. It is found that the rheological properties of the ink depend on the distribution of silica particles, which is dictated by silica functionality, weight content, and processing. Siloxane precursors that vary in chemical functionality are introduced to tailor the mechanical properties of the printed elastomers, which obtain stretchability >65% along with a tensile modulus of 1.9 MPa. After optimizing siloxane chemistry and ink processing, the authors are able to print transparent elastomers. Potential applications are demonstrated for printed structures by printing encapsulation structures for light-emitting diodes, semitransparent dye-filled structures, a microfluidic mixing device, and a multimaterial structure that exhibits temperature-dependent camouflage.

36 MATERIALS SCIENCE↗

Self-generated electrokinetic flows from active-charged boundary patterns

We develop a hydrodynamic description of self-generated electrolyte flow in capillaries whose bounding walls feature nonuniform distributions of charge nonuniform active ionic fluxes. The hydrodynamic velocity arising in such a system has components that are forbidden by symmetry in the absence of charge and fluxes. However, when these two boundary mechanisms are simultaneously present, they can lead to a symmetry broken state where steady flows with both unidirectional and circulatory components emerge. We show that these flow states arise when modulated boundary patterns of charge and fluxes are offset by a flux-charge phase difference, which is associated with the separation between sites of their peak densities on the wall. Mismatch in diffusivity of cationic and anionic species can modify the flow states and becomes an enhancing factor when fluxes of both ion species are being produced together at the same site. We demonstrate that this mechanism can be realized with a microfluidic generator that is powered by enzyme-coated patches that catalyze reactants in the solution to produce fluxes of ions. The local ionic elevation or depletion, which disrupts a nonuniform double layer, promotes self-induced gradients yielding persistent body forces to generate bulk fluid motion. Our work quantifies a boundary-driven mechanism behind self-sustained electrolyte flow in confined environments that exists without any external bulk-imposed fields or gradients. It provides a theoretical framework for understanding the combined effect of active and charged boundaries that are relevant in biological or soft matter systems, and can be utilized in electrofluidic and iontronic applications.

active matter↗

Helfrich-Hurault elastic instabilities driven by geometrical frustration

Here, the Helfrich-Hurault (HH) elastic instability is a well-known mechanism behind patterns that form as a result of strain upon liquid crystal systems with periodic ground states. In the HH model, layered structures undulate and buckle in response to local, geometric incompatibilities in order to maintain the preferred layer spacing. Classic HH systems include cholesteric liquid crystals under electromagnetic field distortions and smectic liquid crystals under mechanical strains, where both materials are confined between rigid substrates. However, richer phenomena are observed when undulation instabilities occur in the presence of deformable interfaces and variable boundary conditions. Understanding how the HH instability is affected by deformable surfaces is imperative for applying the instability to a broader range of materials. In this review, the HH mechanism is reexamined and special focus is given to how the boundary conditions influence the response of lamellar systems to geometrical frustration. Lamellar liquid crystals confined within a spherical shell geometry are used as the model system. Made possible by the relatively recent advances in microfluidics within the past 15 years, liquid crystal shells are composed entirely of fluid interfaces and have boundary conditions that can be dynamically controlled at will. Past and recent work that exemplifies how topological constraints, molecular anchoring conditions, and boundary curvature can trigger the HH mechanism in liquid crystals with periodic ground states is examined. The review ends by identifying similar phenomena across a wide variety of materials, both biological and synthetic. The fact that the HH mechanism is a generic and often overlooked response of periodic materials to geometrical frustration is highlighted.

42 ENGINEERING↗

Contactless conductivity detector for microchip capillary electrophoresis

A microfabricated electrophoresis chip with an integrated contactless conductivity detection system is described. The new contactless conductivity microchip detector is based on placing two planar sensing aluminum film electrodes on the outer side of a poly(methyl methacrylate) (PMMA) microchip (without contacting the solution) and measuring the impedance of the solution in the separation channel. The contactless route obviates problems (e.g., fouling, unwanted reactions) associated with the electrode-solution contact, offers isolation of the detection system from high separation fields, does not compromise the separation efficiency, and greatly simplifies the detector fabrication. Relevant experimental variables, such as the frequency and amplitude of the applied ac voltage or the separation voltage, were examined and optimized. The detector performance was illustrated by the separation of potassium, sodium, barium, and lithium cations and the chloride, sulfate, fluoride, acetate, and phosphate anions. The response was linear (over the 20 microM-7 mM range) and reproducible (RSD = 3.4-4.9%; n = 10), with detection limits of 2.8 and 6.4 microM (for potassium and chloride, respectively). The advantages associated with the contactless conductivity detection, along with the low cost of the integrated PMMA chip/detection system, should enhance the power and scope of microfluidic analytical devices.

NASA Center JPL↗

Microfluidic Extraction of Biomarkers using Water as Solvent

A proposed device, denoted a miniature microfluidic biomarker extractor (mu-EX), would extract trace amounts of chemicals of interest from samples, such as soils and rocks. Traditionally, such extractions are performed on a large scale with hazardous organic solvents; each solvent capable of dissolving only those molecules lying within narrow ranges of specific chemical and physical characteristics that notably include volatility, electric charge, and polarity. In contrast, in the mu-EX, extractions could be performed by use of small amounts (typically between 0.1 and 100 L) of water as a universal solvent. As a rule of thumb, in order to enable solvation and extraction of molecules, it is necessary to use solvents that have polarity sufficiently close to the polarity of the target molecules. The mu-EX would make selection of specific organic solvents unnecessary, because mu-EX would exploit a unique property of liquid water: the possibility of tuning its polarity to match the polarity of organic solvents appropriate for extraction of molecules of interest. The change of the permittivity of water would be achieved by exploiting interactions between the translational states of water molecules and an imposed electromagnetic field in the frequency range of 300 to 600 GHz. On a molecular level, these interactions would result in disruption of the three-dimensional hydrogen-bonding network among liquid-water molecules and subsequent solvation and hydrolysis of target molecules. The mu-EX is expected to be an efficient means of hydrolyzing chemical bonds in complex macromolecules as well and, thus, enabling analysis of the building blocks of these complex chemical systems. The mu-EX device would include a microfluidic channel, part of which would lie within a waveguide coupled to an electronically tuned source of broad-band electromagnetic radiation in the frequency range from 300 to 600 GHz (see figure). The part of the microfluidic channel lying in the waveguide would constitute an interaction volume. The dimensions of the interaction volume would be chosen in accordance with the anticipated amount of solid sample material needed to ensure extraction of sufficient amount of target molecules for detection and analysis. By means that were not specified at the time of reporting the information for this article, the solid sample material would be placed in the interaction volume. Then the electromagnetic field would be imposed within the waveguide and water would be pumped through the interaction volume to effect the extraction.

Amashukeli, Xenia↗

Slopes To Prevent Trapping of Bubbles in Microfluidic Channels

The idea of designing a microfluidic channel to slope upward along the direction of flow of the liquid in the channel has been conceived to help prevent trapping of gas bubbles in the channel. In the original application that gave rise to this idea, the microfluidic channels are parts of micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. It is necessary to prevent trapping of gas bubbles in these devices because uninterrupted liquid pathways are essential for sustaining the electrical conduction and flows that are essential for CE. The idea is also applicable to microfluidic devices that may be developed for similar terrestrial microCE biotechnological applications or other terrestrial applications in which trapping of bubbles in microfluidic channels cannot be tolerated. A typical microCE device in the original application includes, among other things, multiple layers of borosilicate float glass wafers. Microfluidic channels are formed in the wafers, typically by use of wet chemical etching. The figure presents a simplified cross section of part of such a device in which the CE channel is formed in the lowermost wafer (denoted the channel wafer) and, according to the present innovation, slopes upward into a via hole in another wafer (denoted the manifold wafer) lying immediately above the channel wafer. Another feature of the present innovation is that the via hole in the manifold wafer is made to taper to a wider opening at the top to further reduce the tendency to trap bubbles. At the time of reporting the information for this article, an effort to identify an optimum technique for forming the slope and the taper was in progress. Of the techniques considered thus far, the one considered to be most promising is precision milling by use of femtosecond laser pulses. Other similar techniques that may work equally well are precision milling using a focused ion beam, or a small diamond-tipped drill bit.

Greer, Harold E.↗

Fabricated devices for performing bacterial-fungal interaction experiments across scales

Diverse and complex microbiomes are found in virtually every environment on Earth. Bacteria and fungi often co-dominate environmental microbiomes, and there is growing recognition that bacterial-fungal interactions (BFI) have significant impacts on the functioning of their associated microbiomes, environments, and hosts. Investigating BFI in vitro remains a challenge, particularly when attempting to examine interactions at multiple scales of system complexity. Fabricated devices can provide control over both biotic composition and abiotic factors within an experiment to enable the characterization of diverse BFI phenotypes such as modulation of growth rate, production of biomolecules, and alterations to physical movements. Engineered devices ranging from microfluidic chips to simulated rhizosphere systems have been and will continue to be invaluable to BFI research, and it is anticipated that such devices will continue to be developed for diverse applications in the field. This will allow researchers to address specific questions regarding the nature of BFI and how they impact larger microbiome and environmental processes such as biogeochemical cycles, plant productivity, and overall ecosystem resilience. Devices that are currently used for experimental investigations of bacteria, fungi, and BFI are discussed herein along with some of the associated challenges and several recommendations for future device design and applications.

59 BASIC BIOLOGICAL SCIENCES↗

Overcoming the sensitivity vs. throughput tradeoff in Coulter counters: A novel side counter design

We report microfabricated Coulter counters are attractive for point of care (POC) applications since they are label free and compact. However, these approaches inherently suffer from a trade off between sample throughput and sensitivity. The counter measures a change in impedance due to displaced fluid volume by passing cells, and thus the counter's signal increases with the fraction of the sensing volume displaced. Reducing the size of the sensing region requires reductions in volumetric throughput in the absence of increased hydraulic pressure and sensor bandwidth. The risk of mechanical clog formation, rendering the counter inoperable, increases markedly with reductions in the size of the constriction aperture. We present here a microfluidic coplanar Coulter counter device design that overcomes the problem of constriction clogging while capable of operating in microfluidic channels filled entirely with highly conductive sample. The device utilizes microfabricated planar electrodes projecting into one side of the microfluidic channel and is easily integrated with upstream electronic, hydrodynamic, or other focusing units to produce efficient counting which could allow for dramatically increased volumetric and sample throughput. The design lends itself to simple, cost effective POC applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Macromolecular Crystallization in Microfluidics for the International Space Station

At NASA's Marshall Space Flight Center, the Iterative Biological Crystallization (IBC) project has begun development on scientific hardware for macromolecular crystallization on the International Space Station (ISS). Currently ISS crystallization research is limited to solution recipes that were prepared on the ground prior to launch. The proposed hardware will conduct solution mixing and dispensing on board the ISS, be fully automated, and have imaging functions via remote commanding from the ground. Utilizing microfluidic technology, IBC will allow for on orbit iterations. The microfluidics LabChip(R) devices that have been developed, along with Caliper Technologies, will greatly benefit researchers by allowing for precise fluid handling of nano/pico liter sized volumes. IBC will maximize the amount of science return by utilizing the microfluidic approach and be a valuable tool to structural biologists investigating medically relevant projects.

Monaco, Lisa A.↗

Microfluidic Fabrication Techniques for High-Pressure Testing of Microscale Supercritical CO 2 Foam Transport in Fractured Unconventional Reservoirs

Pressure limitations of many microfluidic platforms have been a significant challenge in microfluidic experimental studies of fractured media. As a result, these platforms have not been fully exploited for direct observation of high-pressure transport in fractures. This work introduces microfluidic platforms that enable direct observation of multiphase flow in devices featuring surrogate permeable media and fractured systems. Such platforms provide a pathway to address important and timely questions such as those related to CO 2 capture, utilization and storage. This work provides a detailed description of the fabrication techniques and an experimental setup that may serve to analyze the behavior of supercritical CO 2 (scCO 2 ) foam, its structure and stability. Such studies provide important insights regarding enhanced oil recovery processes and the role of hydraulic fractures in resource recovery from unconventional reservoirs. This work presents a comparative study of microfluidic devices developed using two different techniques: photolithography/wet-etching/ thermal-bonding versus Selective Laser-induced Etching. Both techniques result in devices that are chemically and physically resistant and tolerant of high pressure and temperature conditions that correspond to subsurface systems of interest. Both techniques provide pathways to high-precision etched microchannels and capable lab-on-chip devices. Photolithography/wet-etching, however, enables fabrication of complex channel networks with complex geometries, which would be a challenging task for laser etching techniques. This work summarizes a step-by-step photolithography, wet-etching and glass thermal-bonding protocol and, presents representative observations of foam transport with relevance to oil recovery from unconventional tight and shale formations. In conclusion, this work describes the use of a high resolution monochromatic sensor to observe scCO 2 foam behavior where the entirety of the permeable medium is observed simultaneously while preserving the resolution needed to resolve features as small as 10 μm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microfluidic Pumps Containing Teflon [Trademark] AF Diaphragms

Microfluidic pumps and valves based on pneumatically actuated diaphragms made of Teflon AF polymers are being developed for incorporation into laboratory-on-a-chip devices that must perform well over temperature ranges wider than those of prior diaphragm-based microfluidic pumps and valves. Other potential applications include implanted biomedical microfluidic devices, wherein the biocompatability of Teflon AF polymers would be highly advantageous. These pumps and valves have been demonstrated to function stably after cycling through temperatures from -125 to 120 C. These pumps and valves are intended to be successors to similar prior pumps and valves containing diaphragms made of polydimethylsiloxane (PDMS) [commonly known as silicone rubber]. The PDMS-containing valves ae designed to function stably only within the temperature range from 5 to 80 C. Undesirably, PDMS membranes are somwehat porous and retain water. PDMS is especially unsuitable for use at temperatures below 0 C because the formation of ice crystals increases porosity and introduces microshear.

Willis, Peter↗